Scandinavian Journal of Clinical & Laboratory Investigation最新文献

筛选
英文 中文
Comparison of two automated immunoassays for quantifying ProGRP, SCC and HE4 in serum: impact on diagnostic accuracy. 两种自动免疫测定血清ProGRP、SCC和HE4的比较:对诊断准确性的影响
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-04-01 Epub Date: 2025-02-15 DOI: 10.1080/00365513.2025.2466008
Jaime I Sainz de Medrano, Javier Laguna, Judit Julian, Xavier Filella, Aleix Fabregat, María Luquin, Harol H Hurtado, Alba García Humanes, Manuel Morales-Ruiz, Esther Fernández-Galán
{"title":"Comparison of two automated immunoassays for quantifying ProGRP, SCC and HE4 in serum: impact on diagnostic accuracy.","authors":"Jaime I Sainz de Medrano, Javier Laguna, Judit Julian, Xavier Filella, Aleix Fabregat, María Luquin, Harol H Hurtado, Alba García Humanes, Manuel Morales-Ruiz, Esther Fernández-Galán","doi":"10.1080/00365513.2025.2466008","DOIUrl":"10.1080/00365513.2025.2466008","url":null,"abstract":"<p><p>ProGRP (Progastrin-releasing peptide), SCC (Squamous Cell Carcinoma Antigen), and HE4 (Human epididymis protein 4) are serum tumor markers (STMs) frequently used in clinical practice, particularly for detection and monitoring of ovarian and lung neoplasms. In clinical laboratories, their quantification is commonly performed using automated immunoassays. Nevertheless, variations in results obtained by different immunoassays can impact diagnostic accuracy and effectiveness of patient monitoring. Our aim is to assess differences in STMs concentrations between two automated immunoassays: the Elecsys (Roche) and the Architect (Abbott), which are integrated into the Cobas e402 and Architect i2000SR systems respectively. We included 401 serum samples from patients with different clinical conditions: patients with cancer (<i>n</i> = 170), benign diseases (<i>n</i> = 100) and a control group (<i>n</i> = 131). ProGRP, SCC, and HE4 concentrations were quantified in parallel by both analyzers. To evaluate the clinical impact of changing these methodologies, overall concordance, the kappa index and ROC (Receiver Operating Characteristic) curves were calculated. While some discrepancies were noted in specific cases, overall, we obtained a good correlation for three STMs, with a Pearson coefficient for proGRP (<i>r</i> = 0.99), SCC (<i>r</i> = 0.95) and HE4 (<i>r</i> = 0.973). We also obtained a similar performance in the differential diagnosis of cancer, according to the results of the ROC analyses for Cobas and Archictect assays respectively: proGRP (AUC = 0.92; 0.91), SCC (AUC = 0.90; 0.92) and HE4 (AUC = 0.92; 0.93).</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"116-124"},"PeriodicalIF":1.3,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143425657","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Monitoring CD3+, CD4+ and CD8+ T lymphocytes count after prolonged blood storage. 监测长时间血液储存后CD3+、CD4+和CD8+ T淋巴细胞计数。
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-04-01 Epub Date: 2025-03-08 DOI: 10.1080/00365513.2025.2477630
Claudio Ilardo, Marion Baumelou, Nathalia Arias Rojas, Rachida El Youssfi, Margaux Dirat
{"title":"Monitoring CD3+, CD4+ and CD8+ T lymphocytes count after prolonged blood storage.","authors":"Claudio Ilardo, Marion Baumelou, Nathalia Arias Rojas, Rachida El Youssfi, Margaux Dirat","doi":"10.1080/00365513.2025.2477630","DOIUrl":"10.1080/00365513.2025.2477630","url":null,"abstract":"<p><strong>Introduction: </strong>Monitoring CD3+, CD4+ and CD8+ T lymphocytes count is used in patients with known HIV infection, to determine efficacy of antiretroviral medication. Sometimes, due to the long distance, more time is needed for the sample to reach a more equipped laboratory. The aim of our study was to evaluate the impact of prolonged pre-analytical storage of blood at temperature, 96 h at room temperature, on the quality of results for the three parameters.</p><p><strong>Methods: </strong>The analysis of 60 EDTA-anticoagulated blood samples, stored at room temperature (15-25 °C) after sampling, was conducted after 24 h and 96 h, respectively. The BD FACSLyric<sup>™</sup> system was used to identify and enumerate CD3+, CD4+, and CD8+ T lymphocytes.</p><p><strong>Results: </strong>Following a 96-hour period, no notable discrepancies were observed in the data for CD3+, CD4+, and CD8+ T lymphocytes. Passing-Bablok regression analysis showed no significant difference in y-intercept and slope. The Pearson correlation coefficient (r) demonstrated a significant and strong correlation with rho values of 0.994, 0.992, and 0.996, respectively. The analytical agreements demonstrated that all results fell within the total allowable margin of total error.</p><p><strong>Conclusion: </strong>The results of this study demonstrated that diagnostic samples, monitored for CD3+, CD4+ and CD8+ T lymphocytes, could be stored for up to 96 h without compromising the quality of the results.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"172-174"},"PeriodicalIF":1.3,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143586549","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
CgA100 - eGFR-adjusted serum chromogranin A. CgA100 - egfr调节血清嗜铬蛋白A。
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-04-01 Epub Date: 2025-02-24 DOI: 10.1080/00365513.2025.2466058
Arne Åsberg, Gustav Mikkelsen, Lena Løfblad
{"title":"CgA<sub>100</sub> - eGFR-adjusted serum chromogranin A.","authors":"Arne Åsberg, Gustav Mikkelsen, Lena Løfblad","doi":"10.1080/00365513.2025.2466058","DOIUrl":"10.1080/00365513.2025.2466058","url":null,"abstract":"<p><p>The concentration of chromogranin A in serum (s-CgA) is a general marker of neuroendocrine neoplasms. Unfortunately, s-CgA is increased in several other clinical conditions, including renal failure. The physician who assesses s-CgA values must consider the patients' renal function. How this should be done is not clear. We developed an adjustment formula from the association between median s-CgA and the estimated glomerular filtration rate (eGFR) in 2708 patients where s-CgA was measured by the CgA II KRYPTOR method. We used multivariable fractional polynomial quantile regression with the model ln(s-CgA) = c<sub>0</sub> + c<sub>1</sub> × sex + c<sub>2</sub> × age + c<sub>3</sub> × eGFR, thus accounting for sex and age. The final adjustment formula could be simplified to s-CgA<sub>100</sub> = (eGFR / 100) × s-CgA, where s-CgA<sub>100</sub> is an indication of what s-CgA would be if eGFR in the same patient was 100 mL/minute/1.73 m<sup>2</sup>. In patients with eGFR > 100 mL/minute/1.73 m<sup>2</sup> no adjustment was done. We tested the formula on another patient population (<i>n</i> = 1563), where s-CgA was measured by a RIA method. S-CgA<sub>100</sub> proved to be independent of eGFR in that population. The clinical validity of s-CgA<sub>100</sub> must await further investigations.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"133-137"},"PeriodicalIF":1.3,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143483639","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Three new tools to diagnose B12 deficiency: eGFR-adjusted methylmalonic acid (MMA100), a bivariate reference area for MMA100 and cobalamin, and a cobalamin deficiency index. 诊断B12缺乏症的三个新工具:egfr调节的甲基丙二酸(MMA100), MMA100和钴胺素的双变量参考区域,以及钴胺素缺乏症指数。
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-04-01 Epub Date: 2025-03-01 DOI: 10.1080/00365513.2025.2463084
Arne Åsberg, Gustav Mikkelsen, Ingrid Alsos Lian
{"title":"Three new tools to diagnose B12 deficiency: eGFR-adjusted methylmalonic acid (MMA<sub>100</sub>), a bivariate reference area for MMA<sub>100</sub> and cobalamin, and a cobalamin deficiency index.","authors":"Arne Åsberg, Gustav Mikkelsen, Ingrid Alsos Lian","doi":"10.1080/00365513.2025.2463084","DOIUrl":"10.1080/00365513.2025.2463084","url":null,"abstract":"<p><p>Vitamin B12 (s-cobalamin) and methylmalonic acid (s-MMA) are often interpreted together to diagnose cobalamin deficiency, in context with patient symptomatology, which is many cases is unspecific. Today, clinicians assess test results in relation to the univariate reference limits or decision limits. As s-MMA depends on renal function (glomerular filtration rate, GFR), interpretation can be complicated. To ease the interpretation of the two measurements, we propose three new tools: First, we developed a new formula for adjusting s-MMA to an eGFR of 100 mL/min/1.73 m<sup>2</sup> (s-MMA<sub>100</sub>). The formula was s-MMA<sub>100</sub> = [(eGFR/100)<sup>0.549</sup>] × s-MMA. It was derived from the median relationship between s-MMA and estimated GFR (eGFR) in an ambulant patient population of 4342 individuals, where eGFR was calculated according to the EKFC equations. S-MMA<sub>100</sub> was not associated with eGFR in a US test population of 6852 individuals. Second, we constructed a combined reference range for s-MMA<sub>100</sub> and s-cobalamin from data in a healthy reference population (<i>n</i> = 495 individuals). Third, we proposed a new cobalamin deficiency index, CDI = s-cobalamin/s-MMA<sub>100</sub>, and studied the effect of different decision limits on the prevalence of positive test results in a patient population. Using the 2.5 percentile of CDI in the reference population as a decision limit gave a prevalence of 5.2% positive test results in the patient population. However, as a gold standard for cobalamin deficiency does not exist, we were unable to study the diagnostic accuracy of the CDI. Therefore, the true diagnostic accuracy of these tools is yet unknown and should be investigated.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":"85 2","pages":"101-107"},"PeriodicalIF":1.3,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143754395","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A deep dive into four thyroglobulin immunoassays from analytical perspective. 从分析角度深入探讨四种甲状腺球蛋白免疫测定法。
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-04-01 Epub Date: 2025-03-17 DOI: 10.1080/00365513.2025.2479037
Tuba Saadet Deveci Bulut, Muhittin Abdulkadir Serdar, Mehmet Muhittin Yalçın, Meriç Coşkun, Aylar Poyraz, Seda Gökgöz Acar, Gizem Yaz Aydın, Özlem Gülbahar
{"title":"A deep dive into four thyroglobulin immunoassays from analytical perspective.","authors":"Tuba Saadet Deveci Bulut, Muhittin Abdulkadir Serdar, Mehmet Muhittin Yalçın, Meriç Coşkun, Aylar Poyraz, Seda Gökgöz Acar, Gizem Yaz Aydın, Özlem Gülbahar","doi":"10.1080/00365513.2025.2479037","DOIUrl":"10.1080/00365513.2025.2479037","url":null,"abstract":"<p><strong>Backgrounds: </strong>Serum thyroglobulin immunometric assays (sTg) are crucial for monitoring differentiated thyroid cancer (DTC) treatment. However, challenges such as anti-thyroglobulin autoantibodies (TgAb) and assay variability hinder evaluations. This study assessed four sTg methods-three second-generation (Architect, Access, Elecsys) and one first-generation (Immulite)-following Clinical and Laboratory Standards Institute (CLSI) and American Thyroid Association (ATA) guidelines.</p><p><strong>Methods: </strong>The study compared sTg<sub>(Architect)</sub>, sTg<sub>(Access)</sub>, sTg<sub>(Elecsys)</sub>, and sTg<sub>(Immulite)</sub>. Precision was evaluated per CLSI EP05-A3, while the lower limits of detection (LLD) were assessed using EP17-A2. Passing-Bablok and Bland-Altman analyses were conducted as per EP09c, and semi-quantitative comparisons used Kappa statistics.</p><p><strong>Results: </strong>The second-generation sTgs (Architect, Access, Elecsys) exhibited satisfactory precision (<7% coefficient of variation, CV%), unlike sTg<sub>(Immulite)</sub>, which showed significant deviations and inadequate sensitivity for DTC recurrence (Limit of quantitation, LoQ = 4.59 μg/L). Second-generation sTgs had strong correlations (<i>r</i> > 0.884) across all concentration ranges (≤1, 1-10, >10 μg/L), with biases (slope: 1.131-2.027). sTg<sub>(Immulite)</sub> correlated well with second-generation methods for concentrations >10 μg/L (<i>r</i> > 0.945) but less so for <10 μg/L (<i>r</i> < 0.642). TgAb significantly impacted sTg<sub>(Immulite)</sub>. Kappa statistics revealed strong agreement among second-generation methods (κ > 0.800) but lower concordance with sTg<sub>(Immulite),</sub> especially in TgAb(+) samples (κ: 0.562-0.653). Agreement ratios were high for second-generation methods (0.667-1.000) but variable for sTg<sub>(Immulite)</sub>, particularly at lower concentrations and in TgAb(+) cases (0.097-0.727).</p><p><strong>Conclusions: </strong>sTg<sub>(Immulite)</sub> did not meet LLD and precision criteria for DTC monitoring, facing issues with TgAb interference. Second-generation sTgs demonstrated consistent performance across all concentrations.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"148-159"},"PeriodicalIF":1.3,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143650276","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Performance of enzymatic creatinine methods in the pediatric concentration range. 酶促肌酐方法在儿科浓度范围内的性能。
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-04-01 Epub Date: 2025-02-17 DOI: 10.1080/00365513.2025.2460196
Hilda Hallander, Magnus Lindén, Catarina Lindqvist, Anders Olsson, Sara Marie Larsson
{"title":"Performance of enzymatic creatinine methods in the pediatric concentration range.","authors":"Hilda Hallander, Magnus Lindén, Catarina Lindqvist, Anders Olsson, Sara Marie Larsson","doi":"10.1080/00365513.2025.2460196","DOIUrl":"10.1080/00365513.2025.2460196","url":null,"abstract":"<p><p>Creatinine is a widely used clinical biomarker in adult and pediatric patients to estimate kidney function and glomerular filtration rate. There are however few recent studies that have addressed method performance in the creatinine range relevant for children. This study aimed to describe measurement performance in the pediatric concentration range by comparing commonly used enzymatic methods on four platforms: Abbott Alinity, Radiometer ABL800, Roche Cobas and Siemens Atellica, to the reference method isotope dilution mass spectrometry (IDMS). A secondary aim was to compare the Roche enzymatic methods by using dilutions of control sera issued by the Nordic Association of Clinical Chemistry. We found varying accuracy of the creatinine methods in the low concentration range. The relative difference between platforms, in an investigated range below 75 µmol/L, decreased as creatinine concentration increased. Using an absolute factor to correct for method bias as recommended by one of the manufacturers could hamper measurement trueness in the low concentration range. The <i>in vitro</i> diagnostic industry and stakeholders should strive towards creatinine measurement agreeability. Attention to the pediatric concentration range is needed when correcting for method bias.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"93-100"},"PeriodicalIF":1.3,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143441754","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Short-term stability of routine coagulation tests under different storage temperatures in centrifuged whole blood samples: a practical approach. 不同贮存温度下离心全血常规凝血试验的短期稳定性:一种实用方法。
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-04-01 Epub Date: 2025-02-28 DOI: 10.1080/00365513.2025.2472423
Jacob Rudjord Therkildsen, Anders Abildgaard
{"title":"Short-term stability of routine coagulation tests under different storage temperatures in centrifuged whole blood samples: a practical approach.","authors":"Jacob Rudjord Therkildsen, Anders Abildgaard","doi":"10.1080/00365513.2025.2472423","DOIUrl":"10.1080/00365513.2025.2472423","url":null,"abstract":"","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"168-171"},"PeriodicalIF":1.3,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143531662","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Methadone metabolite (EDDP) crystals in urine: a case report. 尿中美沙酮代谢物(EDDP)结晶一例报告。
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-02-01 Epub Date: 2025-01-30 DOI: 10.1080/00365513.2025.2460200
Laura Pighi, Davide Negrini, Eros Radicchi, Rossella Gottardo, Adolfo Speghini, Elisa Danese, Giuseppe Lippi
{"title":"Methadone metabolite (EDDP) crystals in urine: a case report.","authors":"Laura Pighi, Davide Negrini, Eros Radicchi, Rossella Gottardo, Adolfo Speghini, Elisa Danese, Giuseppe Lippi","doi":"10.1080/00365513.2025.2460200","DOIUrl":"10.1080/00365513.2025.2460200","url":null,"abstract":"<p><p>Crystals in urinary sediment are commonly recognized structures, typically identified by a combination of crystal morphology and urine pH. In this paper, we present the first reported case of EDDP (2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidene) crystals, the primary metabolite of methadone, in a 67-year-old male with hepatorenal syndrome. Routine urinalysis revealed numerous needle-shaped crystals, which prompted further investigation. Advanced techniques, including Raman spectroscopy and mass spectrometry, confirmed the crystals to be EDDP. This case highlights the diagnostic challenge posed by drug-induced crystalluria, particularly in the context of complex comorbidities and chronic opioid therapy. Early recognition and identification of such crystals are crucial to preventing further kidney injury, emphasizing the importance of meticulous urine sediment analysis in clinical practice. This report broadens the spectrum of drugs known to induce crystal formation.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"87-92"},"PeriodicalIF":1.3,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143067657","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluating agreement between separate capillary sampling sites and venous concentrations of β-hydroxybutyrate measured by a point-of-care device and liquid chromatography tandem mass spectrometry. 评价单独的毛细血管采样点和通过即时护理装置和液相色谱串联质谱测定的静脉β-羟基丁酸盐浓度之间的一致性。
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-02-01 Epub Date: 2025-02-03 DOI: 10.1080/00365513.2025.2460198
Lise Nørkjær Bjerg, Henrik Holm Thomsen, Birgitte Sandfeld-Paulsen
{"title":"Evaluating agreement between separate capillary sampling sites and venous concentrations of β-hydroxybutyrate measured by a point-of-care device and liquid chromatography tandem mass spectrometry.","authors":"Lise Nørkjær Bjerg, Henrik Holm Thomsen, Birgitte Sandfeld-Paulsen","doi":"10.1080/00365513.2025.2460198","DOIUrl":"10.1080/00365513.2025.2460198","url":null,"abstract":"<p><p>β-hydroxybutyrate (BHB) is recommended as a measure of ketosis and is often assessed by capillary samples on point-of-care (POC) meters. However, liquid chromatography tandem mass spectrometry (LC-MS/MS) is considered the gold standard for assessing venous samples. The POC device KetoSure<sup>TM</sup> is recommended only for capillary samples from finger pricks. So far, KetoSure<sup>TM</sup> has not been compared to LC-MS/MS just as it has not been evaluated if the sampling site influences the BHB concentration. Blood samples were collected from 16 healthy, fasting individuals before and after ingestion of ketone monoester. BHB concentrations were measured in capillary samples from the earlobe and fingertip, and in venous blood using KetoSure<sup>TM</sup>. Venous plasma samples were collected for BHB quantification using LC-MS/MS. No sign of significant difference between values of BHB measured from the two capillary sampling sites were found. Interestingly, significantly higher values of BHB were measured in capillary samples compared to venous samples reflecting a systematic proportional relationship. No systematic difference was observed in the measured BHB concentrations when comparing KetoSure<sup>TM</sup> and LC-MS/MS results: However, a significant mean bias of 32% reflects a skewness at very low BHB concentrations. In conclusion, capillary BHB concentration did not exhibit variation between the earlobe and fingertip. Conversely, a significant bias was observed between venous and capillary blood and between the POC and LC-MS/MS methods. It is recommended that caution be exercised if individual monitoring of BHB changes encompasses both capillary and venous sampling.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"58-63"},"PeriodicalIF":1.3,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143080969","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Glucometer versus analyzer: comparable results with negligible clinical risk. 血糖仪与分析仪:可比较的结果与可忽略的临床风险。
IF 1.3 4区 医学
Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2025-02-01 Epub Date: 2025-01-25 DOI: 10.1080/00365513.2025.2456917
Alper Gümüş, Cihan Coşkun, Kamil Taha Uçar, İbrahim Erdin, Semih Tek, Betül Evran, Abdulkadir Çat, Oğuzhan Zengi
{"title":"Glucometer versus analyzer: comparable results with negligible clinical risk.","authors":"Alper Gümüş, Cihan Coşkun, Kamil Taha Uçar, İbrahim Erdin, Semih Tek, Betül Evran, Abdulkadir Çat, Oğuzhan Zengi","doi":"10.1080/00365513.2025.2456917","DOIUrl":"10.1080/00365513.2025.2456917","url":null,"abstract":"<p><p>This study assessed the reliability of Roche Accu-Chek Inform II glucometers in a real-world setting. A retrospective analysis was conducted on 6,695 paired results. Capillary samples were tested using Roche Accu-Chek Inform II glucometers, while venous samples were analyzed using Roche Cobas c503/702 analyzers. Compliance was assessed using modified criteria based on the ISO 15197 guideline and the CLSI EP09-A3 guideline using Passing-Bablok regression analysis, Bland-Altman plots, and Surveillance Error Grid (SEG) analysis. The overall compliance of glucometer results within ±15% or 0.83 mmol/L (15 mg/dL) of the reference method was 81.5%, below the acceptance criterion of 94.6%. SEG analysis showed that 90.3% of the paired results fell within the No-risk zone, with less than 0.001% in the moderate/lower-risk zone. The Emergency Department results indicated 87.8% overall compliance and 92.2% of pairs falling in the No-risk zone. Based on the regression analysis, the glucometer results showed a positive constant bias of nearly 0.33 mmol/L (6 mg/dL). The Bland-Altman plots showed a positive mean difference of 0.43 mmol/L for results ≤5.55 mmol/L (≤100 mg/dL) and a positive mean percentage difference of 3.77% for results >5.55 mmol/L (>100 mg/dL), within the permissible deviation. The compliance values ranged from 76.0% to 90.3% for clinical concentration groups, with the highest compliance found between >16.65-22.20 mmol/L (>300-400 mg/dL). The Accu-Chek Inform II glucometers demonstrated in real-world reliability, with most results falling within acceptable risk categories. However, compliance still needs improvement, so manufacturers should assess opportunities for advancement.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"11-19"},"PeriodicalIF":1.3,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"143041319","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信