2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability最新文献

筛选
英文 中文
Tracking maximum loadability conditions in power systems 电力系统最大负荷状态跟踪
C. Vournas, N. Sakellaridis
{"title":"Tracking maximum loadability conditions in power systems","authors":"C. Vournas, N. Sakellaridis","doi":"10.1109/IREP.2007.4410533","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410533","url":null,"abstract":"This paper deals with the problem of identifying emergency conditions during system operation in the case of voltage instability. A novel detection scheme is proposed based on measurement of the controlled voltage of bulk power delivery transformers equipped with load tap changers. The detection is based on the comparison of successive post-tap-change voltages. The detection scheme is purely local, even though it senses a system-wide emergency condition. It is shown that the condition detected is a precursor to maximum loadability and voltage instability.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126008531","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 28
Modal analysis of power systems with doubly fed induction generators 双馈感应发电机电力系统的模态分析
K. Elkington, V. Knazkins, M. Ghandhari
{"title":"Modal analysis of power systems with doubly fed induction generators","authors":"K. Elkington, V. Knazkins, M. Ghandhari","doi":"10.1109/IREP.2007.4410524","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410524","url":null,"abstract":"This article is concerned with the impact of large scale wind farms utilising doubly fed induction generators on the stability of a conventional power system. Inspection of the eigenstructure of the system provides a foundation for assessment of the impact, which is then quantified by means of detailed numerical simulations. Simplified state-space models are used to describe the dynamics of generators in a very simple system, whose network is described by algebraic relations. A third order model is derived for a doubly fed induction generator. Mathematical models are used to identify the behavioural patterns of the system when it is subject to disturbances. Eigenvalue analysis reveals certain interesting properties of the system when it is subject to small disturbances. Numerical simulations show that the addition to a power system of doubly fed induction generators, such as those found in wind farms, improves the response of the system to small disturbances, but can have an adverse impact after larger disturbances.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126153042","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Satellite based communication network for large scale power system applications 卫星通信网络在大型电力系统中的应用
V. Madani, A. Vaccaro, D. Villacci, R. King
{"title":"Satellite based communication network for large scale power system applications","authors":"V. Madani, A. Vaccaro, D. Villacci, R. King","doi":"10.1109/IREP.2007.4410572","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410572","url":null,"abstract":"With the advent of modern day satellite technology, the electric utility industry is exploring opportunities to expand applications that can be served from space-based platforms. Traditionally, in the electric power industry the use of satellite-based technology is seen in many aspects of wide-area management -- weather satellites are used to provide information on demand and to thus, lower the probability of blackouts or brownouts; GPS satellites are used for system control by providing synchronized measurements; and Low Earth Orbiting (LEO) satellites are being investigated for communication of the power system measurements with the desire to improve reliability and provide global coverage with low data latency. These LEO satellites are typically 500 -1500 km above the Earth's surface. The integration of satellite technology into power system operations is emerging now due not only to the large coverage area available from space, improvements in satellite reliability, and lower data-latency, but also the advent of lower cost small satellite buses. Today, satellite applications for power systems are an active area of research in such areas as wide area measurement, control, and communication.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114763361","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Optimal Energy Flow of integrated energy systems with hydrogen economy considerations 考虑氢经济的综合能源系统的最优能量流
A. Hajimiragha, Claudio A. Canizares, Michael Fowler, M. Geidl, Goran Andersson
{"title":"Optimal Energy Flow of integrated energy systems with hydrogen economy considerations","authors":"A. Hajimiragha, Claudio A. Canizares, Michael Fowler, M. Geidl, Goran Andersson","doi":"10.1109/IREP.2007.4410517","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410517","url":null,"abstract":"This paper investigates the formulation of a general optimal energy flow (OEF) problem for integrated energy systems, paying particular attention to \"hydrogen economy\" issues, i.e. production, distribution and utilization of hydrogen, as well as considering the impact of energy storage devices. Based on the concept of energy hubs, the optimal conversion and transmission of multiple energy sources and energy carriers, in particular natural gas, electricity, district heat and hydrogen, considering energy storage devices are discussed. A 3 energy-hub system with electricity, gas, heat and hydrogen production, distribution, demand and storage capabilities is used to illustrate some of the proposed concepts and analysis techniques. The results illustrate some of the advantages of combining different energy sources and carriers, particularly if hydrogen is considered as an integral part of the energy system, given its storage characteristics.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114416997","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 94
Steady-state behavior of a system under market environment near the maximum loading limit 系统在接近最大负荷极限的市场环境下的稳态行为
K. C. Almeida
{"title":"Steady-state behavior of a system under market environment near the maximum loading limit","authors":"K. C. Almeida","doi":"10.1109/IREP.2007.4410520","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410520","url":null,"abstract":"This paper presents a study of the behavior of systems under power markets using a parametric optimal power flow model. A procedure based on a modified set of optimality conditions is used to track the system optimal operating points in the neighborhood of the maximum loading limit, defined by steady-state operating constraints. The characteristics of the operating points in this neighborhood and the consequences of reaching the system unstable operating region are analyzed. Results are presented for a 5-bus example.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128093300","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
E-SIME - A method for transient stability closed-loop emergency control: achievements and prospects 一种暂态稳定闭环应急控制方法:成就与展望
M. Glavic, D. Ernst, D. Ruiz-Vega, L. Wehenkel, M. Pavella
{"title":"E-SIME - A method for transient stability closed-loop emergency control: achievements and prospects","authors":"M. Glavic, D. Ernst, D. Ruiz-Vega, L. Wehenkel, M. Pavella","doi":"10.1109/IREP.2007.4410519","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410519","url":null,"abstract":"A general response-based technique is presented for closed-loop transient stability emergency control. It relies on E-SIME, derived from the hybrid transient stability method, SIME. E-SIME uses real-time information supposed to be furnished by phasor measurement units to predict the stability status of the power system, and, in view of an imminent instability, to design and trigger appropriate countermeasures, while continuing monitoring in order to check their effectiveness or to apply additional ones. Performance of the method in terms of accuracy and rapidity is scrutinized and illustrated on several real-world power system examples. New technical solutions and algorithms for the accurate estimation and prediction of power system quantities most relevant to the method are discussed. The observations from a recent investigation and conclusions that could prove useful for improving further the method are summarized together with some realistic timing considerations. A natural coupling of the two SIME based emergency control techniques: open-loop emergency control and E-SIME, so as to combine their complementary features is also discussed.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126953541","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 40
Insert impact of large-scale wind power generation on the dynamic behaviour of interconnected systems 插入大型风力发电对互联系统动态行为的影响
I. Erlich, F. Shewarega
{"title":"Insert impact of large-scale wind power generation on the dynamic behaviour of interconnected systems","authors":"I. Erlich, F. Shewarega","doi":"10.1109/IREP.2007.4410525","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410525","url":null,"abstract":"This paper deals with the impact of increased wind power generation on the behavior of the interconnected system during and after a contingency situation. The issues considered are the post-fault damping behavior of electromechanical oscillations, performance during a severe short-circuit and frequency stability after a sudden loss of generation. First, the doubly-fed induction (DFIM) based wind turbine and a conventional synchronous generator were simulated in a standalone mode to demonstrate the fundamental differences in terms of their damping behavior. The model was then extended to investigate the characteristic behavior of the DFIM during a severe fault to assess the limits of its fault ride-through capability. Finally, using a large interconnected system the effect of increased wind power generation on the frequency stability of the system after a loss of generation has been discussed.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123118689","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Experiment and simulation of dynamic voltage regulation with multiple distributed energy resources 多分布式能源动态电压调节实验与仿真
Yan Xu, F. Li, J. Kueck, D. Rizy
{"title":"Experiment and simulation of dynamic voltage regulation with multiple distributed energy resources","authors":"Yan Xu, F. Li, J. Kueck, D. Rizy","doi":"10.1109/IREP.2007.4410576","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410576","url":null,"abstract":"Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction between the DEs is studied. The simulation results show the relationship between the voltages in the system and the reactive power required for the voltage regulation. Also, integrated voltage regulation (multiple DEs performing voltage regulation) can increase the voltage regulation capability of DEs and reduce the capital and operating costs.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132550413","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Voltage security constrained reactive power planning considering the costs and performance of VAR devices 考虑成本和性能的电压安全约束无功规划
N. Yorino, M. Eghbal, E. E. El-Araby, Y. Zoka
{"title":"Voltage security constrained reactive power planning considering the costs and performance of VAR devices","authors":"N. Yorino, M. Eghbal, E. E. El-Araby, Y. Zoka","doi":"10.1109/IREP.2007.4410518","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410518","url":null,"abstract":"This paper deals with optimal allocation of fast and slow VAR devices under different load levels. These devices are utilized to maintain system security in normal and contingency states, where corrective and preventive controls are implemented for the contingency cases. Load shedding and fast VAR devices are used in the corrective state in order to quickly restore system stability even though they are expensive, while cheap slow VAR devices can be used in the preventive state to obtain the desired security level. The main objective of this paper is to make a trade-off between economy and security by determining the optimal combination of fast and slow controls (load shedding, new slow and fast VAR devices). To meet the desired security limits, a variety of constraints have to be considered during the investigated transitions states. The proposed RPP problem is a combinatorial optimization problem, which cannot be solved easily by conventional optimization methods. Swarm optimization methods are reported to be efficient to solve combinatorial optimization problems. This paper discovers the efficiency of Particle Swarm Optimization (PSO) and Evolutionary PSO (EPSO) in solving the proposed RPP problem. The proposed approaches have been successfully tested on IEEE 14 bus system and a comparative study is illustrated.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117329100","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Transmission line distance protection using ANFIS and positive sequence components 传输线距离保护采用ANFIS和正序元件
H. Khorashadi-Zadeh, Zuyi Li
{"title":"Transmission line distance protection using ANFIS and positive sequence components","authors":"H. Khorashadi-Zadeh, Zuyi Li","doi":"10.1109/IREP.2007.4410509","DOIUrl":"https://doi.org/10.1109/IREP.2007.4410509","url":null,"abstract":"Conventional distance relays are affected by variables such as source impedance, power angle, fault resistance, etc. This paper presents a new scheme for distance relay using adaptive neuro fuzzy inference system (ANFIS) and positive sequence components of voltage/current waveforms that can reduce the impact of those variables. The change of currents is used for the detection of faults on transmission lines. Four ANFIS modules are used as distance measuring unit. The real and imaginary parts of positive-sequence voltages and currents are selected as the inputs to ANFIS based on numerous experiments. System simulation studies show that the proposed scheme is able to discriminate faults inside and outside the protection zone quickly and accurately.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"120 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122785648","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信