{"title":"Insert impact of large-scale wind power generation on the dynamic behaviour of interconnected systems","authors":"I. Erlich, F. Shewarega","doi":"10.1109/IREP.2007.4410525","DOIUrl":null,"url":null,"abstract":"This paper deals with the impact of increased wind power generation on the behavior of the interconnected system during and after a contingency situation. The issues considered are the post-fault damping behavior of electromechanical oscillations, performance during a severe short-circuit and frequency stability after a sudden loss of generation. First, the doubly-fed induction (DFIM) based wind turbine and a conventional synchronous generator were simulated in a standalone mode to demonstrate the fundamental differences in terms of their damping behavior. The model was then extended to investigate the characteristic behavior of the DFIM during a severe fault to assess the limits of its fault ride-through capability. Finally, using a large interconnected system the effect of increased wind power generation on the frequency stability of the system after a loss of generation has been discussed.","PeriodicalId":214545,"journal":{"name":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IREP.2007.4410525","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21
Abstract
This paper deals with the impact of increased wind power generation on the behavior of the interconnected system during and after a contingency situation. The issues considered are the post-fault damping behavior of electromechanical oscillations, performance during a severe short-circuit and frequency stability after a sudden loss of generation. First, the doubly-fed induction (DFIM) based wind turbine and a conventional synchronous generator were simulated in a standalone mode to demonstrate the fundamental differences in terms of their damping behavior. The model was then extended to investigate the characteristic behavior of the DFIM during a severe fault to assess the limits of its fault ride-through capability. Finally, using a large interconnected system the effect of increased wind power generation on the frequency stability of the system after a loss of generation has been discussed.