4th International Conference on Power Engineering, Energy and Electrical Drives最新文献

筛选
英文 中文
An adaptive PID speed controller for an 8/6 switched reluctance machine 用于8/6开关磁阻电机的自适应PID速度控制器
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635772
S. Rafael, P. Santos, J. Pires
{"title":"An adaptive PID speed controller for an 8/6 switched reluctance machine","authors":"S. Rafael, P. Santos, J. Pires","doi":"10.1109/POWERENG.2013.6635772","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635772","url":null,"abstract":"This paper presents a classical controller with parameters adaptation capability, in an automatic way. This controller is based on a PID where a parameters adaptation algorithm is used and applied to the switched reluctance motor (SRM) speed control. This PID design do not require any kind of adjustment or calibration from the operator. The parameters adaptation algorithm implemented is based on one fuzzy system with a Takagi-Sugeno inference mechanism with some simplifications. These simplifications had the goal to select the parameters adaptation algorithm contributing for a fast controller response. The developed adaptive PID algorithm was modelled and simulated.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115378134","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Permanent magnet flux switching machines — Topologies, analysis and optimization 永磁感应开关机。拓扑,分析和优化
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635633
Jian-Xin Shen, W. Fei
{"title":"Permanent magnet flux switching machines — Topologies, analysis and optimization","authors":"Jian-Xin Shen, W. Fei","doi":"10.1109/POWERENG.2013.6635633","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635633","url":null,"abstract":"Permanent magnet flux switching machines have been attracting revived research interests for various applications over the last decades. Those machines not only inherit most merits from the conventional permanent magnet synchronous machines but also possess a simple passive and hence robust rotor. In this paper, a comprehensive overview on the evolution of new topologies for the permanent magnet flux switching (PMFS) rotary and linear machines is presented, and performance analysis and optimization of such machines are reviewed. Particular emphasis has been placed on practical techniques of torque/force pulsation analysis and reduction. The pros and cons of those PMFS machines are appraised so as to highlight the prospective applications.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124419884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 41
Reference signals generation for active power filter compensation using mathematical morphology 基于数学形态学的有源电力滤波器补偿参考信号的生成
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635842
A. Shintemirov
{"title":"Reference signals generation for active power filter compensation using mathematical morphology","authors":"A. Shintemirov","doi":"10.1109/POWERENG.2013.6635842","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635842","url":null,"abstract":"In this paper the mathematical morphology theory is applied to implement the instantaneous power p-q control strategy of a shunt active power filter. A computer-aided modeling of the active power filter operation using the MATLAB/Simulink environment is presented in details. The simulation results indicate that the implemented control strategy is able to completely compensate the harmonic components of the supply current well below 5% limits, required in the IEEE-519 standard, and reactive power required by the non-linear loads in the power system.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"80 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116645847","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Numerical simulation study on the heat transfer of a spiral tube receiver designed to a thermal power tower 热电塔螺旋管式换热器传热数值模拟研究
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635770
T. Arrif, Abdelfettah Belaid, A. Gama, Rida Zarrit, A. Chehhat
{"title":"Numerical simulation study on the heat transfer of a spiral tube receiver designed to a thermal power tower","authors":"T. Arrif, Abdelfettah Belaid, A. Gama, Rida Zarrit, A. Chehhat","doi":"10.1109/POWERENG.2013.6635770","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635770","url":null,"abstract":"In this work the heat transfer of a spiral tube receiver exposed to concentrated solar radiation is studied theoretically. The simulations were performed using Fluent6.3.26 for two different sections at several Reynolds numbers: 100, 300, 500, 700, and 1000 to see the effect of the inlet velocity on the outlet temperature. The effect of the inlet temperature is also discussed by varying the inlet temperature of the water of 293K to 313K. The results show that the average temperature of the heating and adiabatic surface (inner wall) is decreasing when the velocity inlet is increasing. The outlet temperature of a semicircular section is higher than that of the circular section, but the Nusselt number of this one is twice higher as that of semicircular section and it's due to the geometrical shape of the section.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"101 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117257898","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Firefly algorithm for optimal tuning of PID controller parameters 萤火虫算法对PID控制器参数进行最优整定
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635799
O. Bendjeghaba, S. I. Boushaki, N. Zemmour
{"title":"Firefly algorithm for optimal tuning of PID controller parameters","authors":"O. Bendjeghaba, S. I. Boushaki, N. Zemmour","doi":"10.1109/POWERENG.2013.6635799","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635799","url":null,"abstract":"This paper presents a firefly algorithm (FA) for tuning the proportional-integral-derivative (PID) controller parameters in order to achieve a desired transient response. The proposed approach has superior features including easy implementation, stable convergence characteristic and good computational efficiency. Comparing with Ziegler-Nichols method, the proposed method is more efficient in improuving the step response characteristics.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"62 7","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120844176","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
Fuzzy logic control for rotor field oriented control of a dual star induction machines 双星感应电机转子磁场定向控制的模糊逻辑控制
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635877
S. Lekhchine, Y. Soufi, T. Bahi
{"title":"Fuzzy logic control for rotor field oriented control of a dual star induction machines","authors":"S. Lekhchine, Y. Soufi, T. Bahi","doi":"10.1109/POWERENG.2013.6635877","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635877","url":null,"abstract":"This paper describes a rotor field oriented control of dual star induction motor (DSIM). The difficulty of control of the induction machine is the coupling between the torque and flux because; the changing of the load torque causes unquestionably the flux variation. However, to ensure a control separate of these two variables, the field oriented control is widely used in practice. The performance of this technique depends of changing parameters because adjusting parameters of conventional regulators is based on the system parameters. The variation of system parameters being inevitable, therefore the control loses its reliability. So, it is desirable to use independent regulators of parameters changes, order to, ensure the decoupling independently the variations of the parameters. For this purpose, we use controllers based on fuzzy logic controllers and we test system performance under the influence of parametric variations. The simulations results obtained from MatLab/Simulink are presented followed by a discussion.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"271 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127547387","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
An optimal operating strategy for combined RES-based generators and electric storage systems for load shifting applications 基于可再生能源的发电机和蓄电系统在负荷转移应用中的优化运行策略
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635668
L. Dusonchet, M. Ippolito, E. Telaretti, G. Zizzo, G. Graditi
{"title":"An optimal operating strategy for combined RES-based generators and electric storage systems for load shifting applications","authors":"L. Dusonchet, M. Ippolito, E. Telaretti, G. Zizzo, G. Graditi","doi":"10.1109/POWERENG.2013.6635668","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635668","url":null,"abstract":"This paper focuses on an optimal operating strategy of combined RES-based generators and electric storage systems for small/medium-scale public facilities. The operating strategy can be used in load shifting applications in response to a time-of-use (TOU) rate design with differential pricing for on- and off-peak usage. Load shifting applications can be exploited by customers using battery energy storage systems (BESS) in order to reduce their electricity bill, charging the storage when off-peak time periods are applied and discharging it during on-peak periods, when electricity energy prices are high. The operating strategy is implemented within a bidirectional converter that provides an interface between the low voltage (LV) grid and a PV generator combined with a BESS, so as to contemporary addressing the requirements of the national reference technical standards for active users connections and providing different ancillary services.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125859763","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 60
Study and characterization of the transient electromagnetic field radiated by lightning 雷电辐射瞬态电磁场的研究与表征
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635661
D. Djalel, Labar Hocine
{"title":"Study and characterization of the transient electromagnetic field radiated by lightning","authors":"D. Djalel, Labar Hocine","doi":"10.1109/POWERENG.2013.6635661","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635661","url":null,"abstract":"Lightning fascinates and frightens us. The considerable damage it causes to property and its unfortunate victims plainly demonstrate that the imaginary is based on a phenomenon that is very real and can be fairly well explained, but cannot be combated. Lightning is one of those natural events which catches people's imagination with its obvious violence and the destructive power attributed to it. Only modest attempts can be made to control its effects and the consequences. The aim of the present paper is to dissect, to better understand the phenomenon of lightning and thus make more tools to help for designing a more effective means of protection against lightning, when we discuss the properties of transient electromagnetic fields of lightning (TEMFL) through the characterization of components (Static Induction and Radiant) that form the three vectors of electromagnetic fields (electric vertical, electric horizontal and magnetic Azimuthal). The development of simulation code under Matlab \"Sim-Lightning\" helped us to reconstitute the allure of the spatio-temporal variation (TEMFL). By comparison of the results obtained by our code Sim-Lightning with others in the literature, experimental or simulated were given a very satisfactory approximation.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126094056","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
PDU test lab — Reliability evaluation of power distribution units PDU试验室。配电装置可靠性评估
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635803
Daniel Fros, Marko Rosler, Christian Patz, U. Heinkel
{"title":"PDU test lab — Reliability evaluation of power distribution units","authors":"Daniel Fros, Marko Rosler, Christian Patz, U. Heinkel","doi":"10.1109/POWERENG.2013.6635803","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635803","url":null,"abstract":"In this paper we present a test lab for the reliability evaluation of power distribution units. The presence of a dependable power distribution network is a fundamental prerequisite in the context of datacenter reliability. In addition to uninterruptable power supplies or transfer switches intelligent power distribution units are one of the critical components in the backend power path. Our mission is to investigate and test different PDU implementations with respect to their reliability as a trade-off between effectiveness and self energy consumption.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"319 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123294408","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Control of a small variable speed pumped-storage power plant 小型变速抽水蓄能电站的控制
4th International Conference on Power Engineering, Energy and Electrical Drives Pub Date : 2013-05-13 DOI: 10.1109/POWERENG.2013.6635710
L. Belhadji, S. Bacha, I. Munteanu, D. Roye
{"title":"Control of a small variable speed pumped-storage power plant","authors":"L. Belhadji, S. Bacha, I. Munteanu, D. Roye","doi":"10.1109/POWERENG.2013.6635710","DOIUrl":"https://doi.org/10.1109/POWERENG.2013.6635710","url":null,"abstract":"Variable speed pumped-storage energy systems have recently received significant attention in the renewable energy field, due to its overall efficiency and great potential available worldwide. This emergent technology allows improving the potential of these systems in terms of global efficiency, smoothing the power fluctuations and simplifying the burden classical governing mechanical systems. In this paper, a small variable speed pumped-storage plant with full scale power electronics interface and permanent magnet motor generator is proposed. This approach has been experimentally validated by using a dedicated test rig.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122476111","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信