L. Dusonchet, M. Ippolito, E. Telaretti, G. Zizzo, G. Graditi
{"title":"基于可再生能源的发电机和蓄电系统在负荷转移应用中的优化运行策略","authors":"L. Dusonchet, M. Ippolito, E. Telaretti, G. Zizzo, G. Graditi","doi":"10.1109/POWERENG.2013.6635668","DOIUrl":null,"url":null,"abstract":"This paper focuses on an optimal operating strategy of combined RES-based generators and electric storage systems for small/medium-scale public facilities. The operating strategy can be used in load shifting applications in response to a time-of-use (TOU) rate design with differential pricing for on- and off-peak usage. Load shifting applications can be exploited by customers using battery energy storage systems (BESS) in order to reduce their electricity bill, charging the storage when off-peak time periods are applied and discharging it during on-peak periods, when electricity energy prices are high. The operating strategy is implemented within a bidirectional converter that provides an interface between the low voltage (LV) grid and a PV generator combined with a BESS, so as to contemporary addressing the requirements of the national reference technical standards for active users connections and providing different ancillary services.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"60","resultStr":"{\"title\":\"An optimal operating strategy for combined RES-based generators and electric storage systems for load shifting applications\",\"authors\":\"L. Dusonchet, M. Ippolito, E. Telaretti, G. Zizzo, G. Graditi\",\"doi\":\"10.1109/POWERENG.2013.6635668\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper focuses on an optimal operating strategy of combined RES-based generators and electric storage systems for small/medium-scale public facilities. The operating strategy can be used in load shifting applications in response to a time-of-use (TOU) rate design with differential pricing for on- and off-peak usage. Load shifting applications can be exploited by customers using battery energy storage systems (BESS) in order to reduce their electricity bill, charging the storage when off-peak time periods are applied and discharging it during on-peak periods, when electricity energy prices are high. The operating strategy is implemented within a bidirectional converter that provides an interface between the low voltage (LV) grid and a PV generator combined with a BESS, so as to contemporary addressing the requirements of the national reference technical standards for active users connections and providing different ancillary services.\",\"PeriodicalId\":199911,\"journal\":{\"name\":\"4th International Conference on Power Engineering, Energy and Electrical Drives\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"60\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"4th International Conference on Power Engineering, Energy and Electrical Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2013.6635668\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"4th International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2013.6635668","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An optimal operating strategy for combined RES-based generators and electric storage systems for load shifting applications
This paper focuses on an optimal operating strategy of combined RES-based generators and electric storage systems for small/medium-scale public facilities. The operating strategy can be used in load shifting applications in response to a time-of-use (TOU) rate design with differential pricing for on- and off-peak usage. Load shifting applications can be exploited by customers using battery energy storage systems (BESS) in order to reduce their electricity bill, charging the storage when off-peak time periods are applied and discharging it during on-peak periods, when electricity energy prices are high. The operating strategy is implemented within a bidirectional converter that provides an interface between the low voltage (LV) grid and a PV generator combined with a BESS, so as to contemporary addressing the requirements of the national reference technical standards for active users connections and providing different ancillary services.