{"title":"基于可再生能源的发电机和蓄电系统在负荷转移应用中的优化运行策略","authors":"L. Dusonchet, M. Ippolito, E. Telaretti, G. Zizzo, G. Graditi","doi":"10.1109/POWERENG.2013.6635668","DOIUrl":null,"url":null,"abstract":"This paper focuses on an optimal operating strategy of combined RES-based generators and electric storage systems for small/medium-scale public facilities. The operating strategy can be used in load shifting applications in response to a time-of-use (TOU) rate design with differential pricing for on- and off-peak usage. Load shifting applications can be exploited by customers using battery energy storage systems (BESS) in order to reduce their electricity bill, charging the storage when off-peak time periods are applied and discharging it during on-peak periods, when electricity energy prices are high. The operating strategy is implemented within a bidirectional converter that provides an interface between the low voltage (LV) grid and a PV generator combined with a BESS, so as to contemporary addressing the requirements of the national reference technical standards for active users connections and providing different ancillary services.","PeriodicalId":199911,"journal":{"name":"4th International Conference on Power Engineering, Energy and Electrical Drives","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"60","resultStr":"{\"title\":\"An optimal operating strategy for combined RES-based generators and electric storage systems for load shifting applications\",\"authors\":\"L. Dusonchet, M. Ippolito, E. Telaretti, G. Zizzo, G. Graditi\",\"doi\":\"10.1109/POWERENG.2013.6635668\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper focuses on an optimal operating strategy of combined RES-based generators and electric storage systems for small/medium-scale public facilities. The operating strategy can be used in load shifting applications in response to a time-of-use (TOU) rate design with differential pricing for on- and off-peak usage. Load shifting applications can be exploited by customers using battery energy storage systems (BESS) in order to reduce their electricity bill, charging the storage when off-peak time periods are applied and discharging it during on-peak periods, when electricity energy prices are high. The operating strategy is implemented within a bidirectional converter that provides an interface between the low voltage (LV) grid and a PV generator combined with a BESS, so as to contemporary addressing the requirements of the national reference technical standards for active users connections and providing different ancillary services.\",\"PeriodicalId\":199911,\"journal\":{\"name\":\"4th International Conference on Power Engineering, Energy and Electrical Drives\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-05-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"60\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"4th International Conference on Power Engineering, Energy and Electrical Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2013.6635668\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"4th International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2013.6635668","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 60

摘要

本文的重点是为中小型公共设施提供基于可再生能源的发电机和蓄电系统的最佳组合运行策略。该运行策略可用于负荷转移应用,以响应使用时间(TOU)费率设计,对高峰期和非高峰期使用实行差别定价。使用电池储能系统(BESS)的用户可以利用负荷转移应用来减少电费支出,在非高峰时段为电池储能系统充电,并在电能价格较高的高峰时段放电。该运行策略是在双向变流器内实施的,该变流器为低压电网和光伏发电机以及蓄电池储能系统之间提供了一个接口,以满足国家参考技术标准对有源用户连接的要求,并提供不同的辅助服务。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An optimal operating strategy for combined RES-based generators and electric storage systems for load shifting applications
This paper focuses on an optimal operating strategy of combined RES-based generators and electric storage systems for small/medium-scale public facilities. The operating strategy can be used in load shifting applications in response to a time-of-use (TOU) rate design with differential pricing for on- and off-peak usage. Load shifting applications can be exploited by customers using battery energy storage systems (BESS) in order to reduce their electricity bill, charging the storage when off-peak time periods are applied and discharging it during on-peak periods, when electricity energy prices are high. The operating strategy is implemented within a bidirectional converter that provides an interface between the low voltage (LV) grid and a PV generator combined with a BESS, so as to contemporary addressing the requirements of the national reference technical standards for active users connections and providing different ancillary services.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信