2010 9th International Conference on Environment and Electrical Engineering最新文献

筛选
英文 中文
Current trends and potential competition in German electric power industry 德国电力工业的发展趋势和潜在竞争
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5490043
M. Vasilyev
{"title":"Current trends and potential competition in German electric power industry","authors":"M. Vasilyev","doi":"10.1109/EEEIC.2010.5490043","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5490043","url":null,"abstract":"The paper describes some trends in electric power industry in Germany in view of potential competition in electricity generation. Some conclusions on the possible trends and risks are made.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129079337","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
State-feedback current control of VSI-based D-STATCOM for load compensation 基于vsi的D-STATCOM负载补偿状态反馈电流控制
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5490431
P. Jafarian, M. Tavakoli Bina
{"title":"State-feedback current control of VSI-based D-STATCOM for load compensation","authors":"P. Jafarian, M. Tavakoli Bina","doi":"10.1109/EEEIC.2010.5490431","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5490431","url":null,"abstract":"This paper presents a closed-loop control technique for the D-STATCOM, aiming at load balancing as well as load power factor correction. Compensation for the oscillatory components of the active and reactive powers of an unbalanced load requires the D-STATCOM to inject unbalanced three-phase currents to the power network. For this purpose, the compensator current references would contain an ac component on top of the dc value in the rotating-reference-frame. As a result, the closed-loop current control of the device would become different from that under balanced condition. In this paper, a state-feedback-based current controller is proposed and the engaged pulse width modulation is enhanced by dynamically modification of the switching duty ratios to tackle the dc-side voltage oscillations effects. The whole method, including the control technique and the modulation compensation, is simulated by using PSCAD/EMTDC software to demonstrate the validity of the proposed approach.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125704035","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Analytical synchronization of two-end measurements for fault location based on distributed model of overhead line 基于架空线路分布式模型的故障定位两端测量分析同步
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5489945
P. Dawidowski, J. Izykowski
{"title":"Analytical synchronization of two-end measurements for fault location based on distributed model of overhead line","authors":"P. Dawidowski, J. Izykowski","doi":"10.1109/EEEIC.2010.5489945","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5489945","url":null,"abstract":"This paper presents analytical synchronization methods for two-end measurements of voltages and currents using distributed model of overhead line. Three approaches are presented: synchronization using pre-fault or fault measurements with various cases of available currents and voltages signals or using both pre-fault and fault signals.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126582412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Methods of frequency estimation in PWM converters systems PWM变换器系统的频率估计方法
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5489915
P. Kostyła
{"title":"Methods of frequency estimation in PWM converters systems","authors":"P. Kostyła","doi":"10.1109/EEEIC.2010.5489915","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5489915","url":null,"abstract":"Fast determination of frequency of the fundamental waveform of voltages and currents is essential for the control and protection of electrical power systems. In this paper the advanced methods of frequency estimation of distorted signals are presented. These methods, basing on Prony's model, are useful for frequency estimation of distorted signals in real time mode. These signals appear in circuit consisted frequency converters. In order to obtain improvement of preciseness and quality some modifications of the algorithm were introduced.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129080845","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Solar energy storage using hydrogen technology 利用氢能技术的太阳能储能
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5489998
Z. Hradílek, P. Moldrik, Roman Chválek
{"title":"Solar energy storage using hydrogen technology","authors":"Z. Hradílek, P. Moldrik, Roman Chválek","doi":"10.1109/EEEIC.2010.5489998","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5489998","url":null,"abstract":"At present, photovoltaic (PV) power plants are the fastest-growing renewable energy source in the Czech Republic. This rapid development of PV sources is having a negative effect on the electric power system control. One option for mitigating this effect is to store the energy generated by PV in times of excess power in the grid and supply it to the grid when required, i.e., during peak periods of the daily load curve.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128023530","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A constant frequency hybrid exciter for an autonomous wind energy conversion system 自主风能转换系统的恒频混合励磁器
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5490029
A. Karthikeyan, C. Nagamani, G. Saravana Ilango, M. Jaya Bharata Reddy
{"title":"A constant frequency hybrid exciter for an autonomous wind energy conversion system","authors":"A. Karthikeyan, C. Nagamani, G. Saravana Ilango, M. Jaya Bharata Reddy","doi":"10.1109/EEEIC.2010.5490029","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5490029","url":null,"abstract":"This paper proposes a hybrid exciter for the standalone wind turbine driven induction generator. It consists of one set of fixed capacitor bank and a voltage source inverter connected in parallel at the stator terminals of the generator. The inverter provides the necessary variable component of lagging reactive power to the induction generator so that nominal output voltage is obtained even at lower speeds and higher loads. The dc bus voltage of inverter is maintained using the combination of a bidirectional dc-dc converter and a battery. The battery is used as a complementary energy source to minimise the impact of the fluctuations in the wind power on the connected load. The scheme has reduced control complexity because the inverter is operated with a fixed PWM and hence the control is restricted mainly to switching the bi-directional dc-dc converter. There is no need for a position or a speed sensor. The complete system is modeled and simulated in the MATLAB/Simulink environment. Simulation results validate the proposed power generation scheme as a viable alternative for remote areas.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132302904","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Wind power forecasting by an empirical model using NWP outputs 利用NWP输出的经验模型预测风电功率
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5490019
E. Pelikán, K. Eben, J. Resler, P. Jurus, P. Krč, Marek Brabec, T. Brabec, Petr Musilek
{"title":"Wind power forecasting by an empirical model using NWP outputs","authors":"E. Pelikán, K. Eben, J. Resler, P. Jurus, P. Krč, Marek Brabec, T. Brabec, Petr Musilek","doi":"10.1109/EEEIC.2010.5490019","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5490019","url":null,"abstract":"This paper presents a simple and robust wind power forecasting approach using inputs from a state-of-the-art numerical weather prediction models (NWP) with mesoscale resolution. The model can be used for short-term and longer term forecasting horizon up to 72 hours ahead. The forecasting ability of the presented approach is demonstrated using real power production data from the Czech Republic.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131456998","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 24
Comparative study of single-phase earth fault responses of FCC-HVDC and LCC-HVDC FCC-HVDC与LCC-HVDC单相接地故障响应的比较研究
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5489971
Jiazhu Xu, L. Luo, Junfeng Bai, Xiaofang Li, Yong Li, C. Rehtanz, Dechang Yang, U. Hager
{"title":"Comparative study of single-phase earth fault responses of FCC-HVDC and LCC-HVDC","authors":"Jiazhu Xu, L. Luo, Junfeng Bai, Xiaofang Li, Yong Li, C. Rehtanz, Dechang Yang, U. Hager","doi":"10.1109/EEEIC.2010.5489971","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5489971","url":null,"abstract":"In order to study the transient response characteristics of Filter Commutated Converter (FCC) under the condition of single-phase earth fault, in the paper, referring to the CIGRE HVDC benchmark testing model (LCC-HVDC), on the basic of non-changing the short circuit ration (SCR) and some parameters, combining the connecting features of FCC, the new testing model based on FCC (FCC-HVDC) is established in the PSCAD/EMTDC; based the two models of LCC-HVDC and FCC-HVDC, the magnetizing and harmonic characteristics are analyzed comparatively under the single-phase earth fault, the results indicated: (1) the magnetizing current of the converter transformer are both a sudden increase and unidirectional magnetization, but the magnetizing characteristics of FCC-HVDC is better than LCC-HVDC; (2) FCC-HVDC still maintains its good harmonic suppression characteristics.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"99 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132612033","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Sequence Impedances criterion for loss of main detection of embedded generation 嵌入式电源主检测损耗的序列阻抗判据
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5489986
A. Darabi, A. Hassannia, M. Saedi, A. Moeini
{"title":"Sequence Impedances criterion for loss of main detection of embedded generation","authors":"A. Darabi, A. Hassannia, M. Saedi, A. Moeini","doi":"10.1109/EEEIC.2010.5489986","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5489986","url":null,"abstract":"Numbers of large and medium size embedded generators, which are working as paralleled with the main in distribution system, are increasing rapidly. Since the existing generation, transmission and distribution systems are planed based on Centralized Generation with no considering of embedded generators, some adverse consequences and problems are initiated in power system control and protection. One major issue is the protection of generator against loss of main (LOM) or islanding conditions. A proficient diagnosis system should discriminate LOM from normal occurrences such as switching, load variations or other common faults and it should detect LOM very quickly. In this paper, embedded generations and consequent dilemmas in distribution systems are investigated and by categorizing the LOM diagnosis methods, a comparison and discussion are presented. Furthermore, a system comprising an embedded generation unit and a typical distribution network are simulated. Wide range possible occurrences are examined and several LOM detection criteria such as frequency, voltage and power variations of embedded generation unit in the distribution network are studied. A new method based on sequence Impedances of the possibly existing synchronous generator in the distribution network is developed that presents an improved diagnosis system performance. The MATLAB/SIMULINK based system simulation shows the validity of the proposed method.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123878009","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Extreme weather events and power systems with high wind penetration: case study on the Irish winter of 2009/10 极端天气事件与高风渗透的电力系统:2009/10年爱尔兰冬季的案例研究
2010 9th International Conference on Environment and Electrical Engineering Pub Date : 2010-05-16 DOI: 10.1109/EEEIC.2010.5489918
P. Leahy
{"title":"Extreme weather events and power systems with high wind penetration: case study on the Irish winter of 2009/10","authors":"P. Leahy","doi":"10.1109/EEEIC.2010.5489918","DOIUrl":"https://doi.org/10.1109/EEEIC.2010.5489918","url":null,"abstract":"Wind power's share of the generation mix is increasing on most of the world's power systems. As the penetration of variable, non-dispatchable generators increases, power systems are becoming more sensitive to extreme weather events on the supply side as well as on the demand side. Sensitivity of supply to weather is mainly due to wind variability while demand sensitivity is driven by space heating or cooling loads. The interplay of these two weather-driven effects is of particular concern if demand spikes driven by low temperatures coincide with periods of low winds. The Republic of Ireland now has over 1.2 GW connected wind capacity, compared to a total dispatchable capacity of 6.3 GW, and a target of over 30% of electricity generation from wind by 2020. A further 0.3 GW of wind capacity is present in the interconnected Northern Ireland system. In December 2009 and January 2010 Ireland experienced a prolonged spell of unusually cold conditions. During much of this time, wind generation output was low due to low wind speeds. Figures for power demand, wind generation and wholesale electricity market prices during this event are presented as part of a case study of the effects of weather extremes on power systems with high penetrations of variable renewable generation. Despite the unusual meteorological conditions, generation capacity was found to be adequate to meet the demand peaks.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"99 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125222547","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信