Jiazhu Xu, L. Luo, Junfeng Bai, Xiaofang Li, Yong Li, C. Rehtanz, Dechang Yang, U. Hager
{"title":"Comparative study of single-phase earth fault responses of FCC-HVDC and LCC-HVDC","authors":"Jiazhu Xu, L. Luo, Junfeng Bai, Xiaofang Li, Yong Li, C. Rehtanz, Dechang Yang, U. Hager","doi":"10.1109/EEEIC.2010.5489971","DOIUrl":null,"url":null,"abstract":"In order to study the transient response characteristics of Filter Commutated Converter (FCC) under the condition of single-phase earth fault, in the paper, referring to the CIGRE HVDC benchmark testing model (LCC-HVDC), on the basic of non-changing the short circuit ration (SCR) and some parameters, combining the connecting features of FCC, the new testing model based on FCC (FCC-HVDC) is established in the PSCAD/EMTDC; based the two models of LCC-HVDC and FCC-HVDC, the magnetizing and harmonic characteristics are analyzed comparatively under the single-phase earth fault, the results indicated: (1) the magnetizing current of the converter transformer are both a sudden increase and unidirectional magnetization, but the magnetizing characteristics of FCC-HVDC is better than LCC-HVDC; (2) FCC-HVDC still maintains its good harmonic suppression characteristics.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 9th International Conference on Environment and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2010.5489971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
In order to study the transient response characteristics of Filter Commutated Converter (FCC) under the condition of single-phase earth fault, in the paper, referring to the CIGRE HVDC benchmark testing model (LCC-HVDC), on the basic of non-changing the short circuit ration (SCR) and some parameters, combining the connecting features of FCC, the new testing model based on FCC (FCC-HVDC) is established in the PSCAD/EMTDC; based the two models of LCC-HVDC and FCC-HVDC, the magnetizing and harmonic characteristics are analyzed comparatively under the single-phase earth fault, the results indicated: (1) the magnetizing current of the converter transformer are both a sudden increase and unidirectional magnetization, but the magnetizing characteristics of FCC-HVDC is better than LCC-HVDC; (2) FCC-HVDC still maintains its good harmonic suppression characteristics.