2017 IEEE International Conference on Imaging Systems and Techniques (IST)最新文献

筛选
英文 中文
Temporal difference method based on positive and negative energy distribution in moving objects detection 基于正负能量分布的时间差分法在运动目标检测中的应用
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261473
Fu Feiran, Fang Ming, Yang Huamin
{"title":"Temporal difference method based on positive and negative energy distribution in moving objects detection","authors":"Fu Feiran, Fang Ming, Yang Huamin","doi":"10.1109/IST.2017.8261473","DOIUrl":"https://doi.org/10.1109/IST.2017.8261473","url":null,"abstract":"The traditional temporal difference method under dynamic background will not extracted moving objects. In this paper, we propose a method based on positive and negative energy distribution and combine the LK optical flow method to achieve effective moving objects detection. Using series frames obtain the positive and negative energy distribution. The Gaussian kernel density function is used to estimate the density of the energy distribution histogram of the second frame. When the kernel density is smaller than the threshold value, it is considered to be the background movement with smaller energy. While the kernel density is larger than the threshold value, it is considered to be the moving objects with larger energy. Experimental results demonstrate that the method effectively detect the moving target in the dynamic background.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133904958","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Liver sub-pixel detection method on magnetic resonance images 肝脏核磁共振图像亚像素检测方法
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261457
Suo Qinghua, Y. Xuedong, L. Juntao, Zhao Yan
{"title":"Liver sub-pixel detection method on magnetic resonance images","authors":"Suo Qinghua, Y. Xuedong, L. Juntao, Zhao Yan","doi":"10.1109/IST.2017.8261457","DOIUrl":"https://doi.org/10.1109/IST.2017.8261457","url":null,"abstract":"Liver is an important organ, and magnetic resonance is the most commonly used hepatology method in current. Precisely liver lesion detection can help doctor diagnose. But organ and lesion identifying edge in medical images precisely is the key technology to insure the precision of the medical clinical and treatment. According the common sub-pixel algorithms of edge detection algorithm merits, a new sub-pixel edge detection algorithm which the Zernike moment and the sigmoid function fitting methods has been proposed using liver edge detection in MRI. This algorithm adopting marks calculate the Zernike moments parameters, employs the Sigmoid function fitting to Zernike marks obtains the Zernike distance threshold step depth threshold. The experiment demonstrates that the precision of the proposed algorithm achieves liver edge and lesion cell edge. This methods has a well satisfies the requirements for medical processing, and has a good universal for other organ edge detection in magnetic resonance imaging or computed tomography.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"56 6","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132870324","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A deep CNN based multi-class classification of Alzheimer's disease using MRI 基于深度CNN的MRI阿尔茨海默病多类分类
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261460
Ammarah Farooq, SyedMuhammad Anwar, Muhammad Awais, S. Rehman
{"title":"A deep CNN based multi-class classification of Alzheimer's disease using MRI","authors":"Ammarah Farooq, SyedMuhammad Anwar, Muhammad Awais, S. Rehman","doi":"10.1109/IST.2017.8261460","DOIUrl":"https://doi.org/10.1109/IST.2017.8261460","url":null,"abstract":"In the recent years, deep learning has gained huge fame in solving problems from various fields including medical image analysis. This work proposes a deep convolutional neural network based pipeline for the diagnosis of Alzheimer's disease and its stages using magnetic resonance imaging (MRI) scans. Alzheimer's disease causes permanent damage to the brain cells associated with memory and thinking skills. The diagnosis of Alzheimer's in elderly people is quite difficult and requires a highly discriminative feature representation for classification due to similar brain patterns and pixel intensities. Deep learning techniques are capable of learning such representations from data. In this paper, a 4-way classifier is implemented to classify Alzheimer's (AD), mild cognitive impairment (MCI), late mild cognitive impairment (LMCI) and healthy persons. Experiments are performed using ADNI dataset on a high performance graphical processing unit based system and new state-of-the-art results are obtained for multiclass classification of the disease. The proposed technique results in a prediction accuracy of 98.8%, which is a noticeable increase in accuracy as compared to the previous studies and clearly reveals the effectiveness of the proposed method.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132132665","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 186
High-speed railway catenary components detection using the cascaded convolutional neural networks 基于级联卷积神经网络的高速铁路接触网成分检测
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261459
Junwen Chen, Zhigang Liu, Hongrui Wang, Kai Liu
{"title":"High-speed railway catenary components detection using the cascaded convolutional neural networks","authors":"Junwen Chen, Zhigang Liu, Hongrui Wang, Kai Liu","doi":"10.1109/IST.2017.8261459","DOIUrl":"https://doi.org/10.1109/IST.2017.8261459","url":null,"abstract":"With the massive construction of the China high-speed railway, it is of a great significance to propose an automatic approach to inspect the defects of the catenary support devices. Based on the obtained high resolution images, the detection and extraction of the components on the catenary support devices are the vital steps prior to their defect report. Inspired by the existing object detection Faster R-CNN framework, a cascaded convolutional neural network (CNN) architecture is built to successively detect the various components and the tiny fasteners in the complex catenary support device structures. Meanwhile, some missing states of the fasteners on the cantilever joints are directly reported via our proposed architecture. Experiments on the Wuhan-Guangzhou high-speed railway dataset demonstrate a practical performance of the component detection with good adaptation and robustness in complex environments, feasible to accurately inspect the extremely tiny defects on the various catenary components.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"64 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133079110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Ultrasonic spectral analysis for biomedical imaging 用于生物医学成像的超声光谱分析
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261549
Jianguo Ma, Min Wei, Lijun Xu, Boya Chen, Yulin Liu, Jie Du, Zijie Fang
{"title":"Ultrasonic spectral analysis for biomedical imaging","authors":"Jianguo Ma, Min Wei, Lijun Xu, Boya Chen, Yulin Liu, Jie Du, Zijie Fang","doi":"10.1109/IST.2017.8261549","DOIUrl":"https://doi.org/10.1109/IST.2017.8261549","url":null,"abstract":"Although ultrasound imaging has been widely applied in medical diagnosis for decades, the data processing remains primitive. Traditional B-mode ultrasound imaging exhibits the amplitude of the scattered ultrasonic signals as brightness of the images, neglecting rich information delivered by the frequency modulation of the signals. The frequency variation in the spectrum contains nonlinear vibrations which are specific for given tissues. We hypothesize that detailed analysis and characterization of the spectrum enable the software to recognize the signals from different organs or from diseased regions. Wavelet transform was utilized to exhibit the ultrasonic signal in both time and frequency domain, followed by the principal component analysis which extracted the feature of the frequency. This analysis holds the potential of intelligent diagnosis by ultrasound imaging.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"75 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132701370","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Simulation on applying Gabor filtering method to direct laser absorption spectroscopy Gabor滤波法在直接激光吸收光谱中的应用仿真
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261532
H. Cui, Fei Wang
{"title":"Simulation on applying Gabor filtering method to direct laser absorption spectroscopy","authors":"H. Cui, Fei Wang","doi":"10.1109/IST.2017.8261532","DOIUrl":"https://doi.org/10.1109/IST.2017.8261532","url":null,"abstract":"Direct laser absorption spectroscopy plays an important role in trace gas monitoring for environment protection. The gas concentration can be calculated by integration of the measured absorption line. But the absorption signals often get distorted by noise, which reduces spectral signal-to-noise ratio(SNR). By applying Gabor filtering method to simulated absorption spectral signal, signal-to-noise ratios have been significantly improved, which is of great importance for gas concentration determination precision and stability. Taking the CO absorption signal near 6380.3cm−1 as an example, the results show that Gabor filtering method is a very useful de-noising tool for spectral noise reduction.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122082349","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Phase aberration correction by bent-ray tracing method for ultrasound computed tomography 超声计算机断层扫描弯曲射线追踪法相位像差校正
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261510
Xiaolei Qu, S. Fan, T. Azuma
{"title":"Phase aberration correction by bent-ray tracing method for ultrasound computed tomography","authors":"Xiaolei Qu, S. Fan, T. Azuma","doi":"10.1109/IST.2017.8261510","DOIUrl":"https://doi.org/10.1109/IST.2017.8261510","url":null,"abstract":"Ultrasound computed tomography (USCT) is a promising technique for breast cancer detection. It can provide three modalities: sound speed image, attenuation image, and reflection image. The reflection image can have high-resolution, but it always be reconstructed using a pre-determined sound speed based on homogeneous assumption, and the mismatch between the pre-determined speed and real speeds of inhomogeneous tissue could result in phase aberration and degrade the image quality and resolution. In this article, we proposed and evaluated to correct phase aberration by bent-ray tracing method using sound speed image of USCT. First, sound speed image of USCT was reconstructed by first arrival picking method, bent-ray tracing method and Simultaneous Algebraic Reconstruction Technique (SART). Second, the propagation time from each element to each pixel of image was calculated by bent-ray tracing method using the sound speed image. Third, scatter-signal-delay-time was calculated and reflection image is reconstructed by using Synthetic Aperture (SA) method. For evaluation, both simulation and experiment validation were conducted. With regard to the simulation, the homogeneous point scatter simulation showed that the phase aberration might increase diameter of point-spread function (PSF) from approximate 1 to 5 mm; the complex-breast-model simulation demonstrated that the proposed method could correct phase aberration and decrease diameter of PSF from about 2 to 1 mm. With regard to the experiment, the results demonstrated that the proposed method could correct phase aberration and improve the image quality of breast phantom.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122359744","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Fast shape matching and retrieval with dynamic angular partition descriptor 基于动态角分区描述符的快速形状匹配与检索
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261497
P. Shi, Yongkun Wang, Ying Hu, Yaohui Jin
{"title":"Fast shape matching and retrieval with dynamic angular partition descriptor","authors":"P. Shi, Yongkun Wang, Ying Hu, Yaohui Jin","doi":"10.1109/IST.2017.8261497","DOIUrl":"https://doi.org/10.1109/IST.2017.8261497","url":null,"abstract":"Shape matching and retrieval are fundamental topics in image processing area. With the rapid growing number of images, fast speed in shape matching is necessary, but most methods focus on the retrieval accuracy. In this article, we propose a dynamic angular partition descriptor (DAPD) based on the statistical distribution of the shape contour points, which is scale invariant inherently. DAPD has low computational complexity which enables fast shape matching, and naturally sacrifices a little accuracy in retrieval. However, we leverage the angle sensitivity in the structure of DAPD, which can compensate the loss in accuracy by 4.46% on average. Experiments on several shape databases show that, our descriptor can speed up shape matching by up to 13X, but still retains 91.92% accuracy in the top-4 similar shapes in retrieval tests. Meanwhile, we generate some distorted shapes to verify the robustness of DAPD against rotation and noise.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"123 3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124935826","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Rapid preprocessing of FMCW GB-SAR echo based on FPGA 基于FPGA的FMCW GB-SAR回波快速预处理
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261516
H. Tan, Weiming Tian, Cheng Hu
{"title":"Rapid preprocessing of FMCW GB-SAR echo based on FPGA","authors":"H. Tan, Weiming Tian, Cheng Hu","doi":"10.1109/IST.2017.8261516","DOIUrl":"https://doi.org/10.1109/IST.2017.8261516","url":null,"abstract":"To reduce the huge data-operation and transmission pressure in the slope-monitoring radar system, and make full use of the hardware resources in the Field-Programmable Gate Array (FPGA), this paper designs a rapid preprocessing system for echo data from the frequency-modulated continuous-wave (FMCW) ground-based synthetic aperture radar (GB-SAR). Thanks to the parallel processing capability and pipeline structure of FPGA, this system achieves coherent accumulation, filtering and pulse compression in the range dimension with the RAM/ROM and FFT IP core in ISE development platform. By this process, the signal-to-noise ratio (SNR) of the signal is improved significantly and the sidelobe of the pulse compression result in range dimension is suppressed effectively. Meanwhile, the completion of dechirp processing in FPGA reduces the operating pressure of Digital Signal Processor (DSP) and improve the system operating efficiency to a certain extent.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"102 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129153043","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
The GVF measurement and flow regime study of gas-water flows by ERT sensor ERT传感器气水流场流场测量及流型研究
2017 IEEE International Conference on Imaging Systems and Techniques (IST) Pub Date : 2017-10-01 DOI: 10.1109/IST.2017.8261456
Yuchi Deng, Yinyan Liu, Yi Li
{"title":"The GVF measurement and flow regime study of gas-water flows by ERT sensor","authors":"Yuchi Deng, Yinyan Liu, Yi Li","doi":"10.1109/IST.2017.8261456","DOIUrl":"https://doi.org/10.1109/IST.2017.8261456","url":null,"abstract":"Two typical 8-electrodes electrical resistance tomography (ERT) sensors installed on the venturi throat were used to measure gas-water two-phase flows both in horizontal and vertical pipeline with different gas volume fraction (GVF) and liquid flow rate. The range of GVF is from 8% to 95% and liquid flow rate is from 1m3/h to 6m3/h. By observing glass window and 3D ERT reconstruction image, the gas-water flow distributions can be visualized in real-time. A normalization process of reconstructed image is used to describe the relative conductivity. Meanwhile GVF is calculated according to Maxwell and Begovich models.","PeriodicalId":187213,"journal":{"name":"2017 IEEE International Conference on Imaging Systems and Techniques (IST)","volume":"153 ","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120870134","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书