{"title":"Treatment efficacy of non-metal and single-retainer resin-bonded prostheses for anterior single-tooth loss: A systematic review.","authors":"Hajime Minakuchi, Shoko Miura, Akikazu Shinya, Takuya Horimai, Yoshizo Matsuka, Katsushi Tamaki, Kazuo Okura, Akira Nishiyama, Masamitsu Oshima, Masaki Kakudo, Kazuya Doi, Yoshihiro Yamaguchi, Megumi Watanabe, Kazuyoshi Baba, Takuo Kuboki","doi":"10.2186/jpr.JPR_D_25_00320","DOIUrl":"https://doi.org/10.2186/jpr.JPR_D_25_00320","url":null,"abstract":"<p><strong>Purpose: </strong>This systematic review aimed to evaluate the treatment efficacy of resin-bonded fixed partial dentures (RBFPDs) in adults with single-tooth loss. The target interventions included the use of: (1) non-metal retainers, (2) single-retainer (SR) RBFPDs, and (3) non-metal SR-RBFPDs, compared with conventional metal and two-retainer (TR) RBFPDs.</p><p><strong>Study selection: </strong>A comprehensive literature search of the MEDLINE, CENTRAL, Web of Science, and Ichushi databases up to November 30, 2025 was conducted; additionally, reference list screening and manual searches were performed by an external organization. Target outcomes included RBFPD survival rate, abutment tooth prognosis, oral health-related quality of life (OHRQoL), patient satisfaction, esthetics, periodontal status, and oral function. Two reviewers independently conducted study selection, data extraction, and risk of bias assessment, with disagreements resolved through discussion.</p><p><strong>Results: </strong>A total of eight, six, and three articles were included for each respective comparison. There were no significant differences in survival rate, esthetics, OHRQoL, patient satisfaction, or periodontal condition between non-metal and metal retainer RBFPDs. Comparisons involving SR-RBFPDs suggested a tendency toward favorable survival and abutment tooth outcomes; however, these findings were based on a limited number of studies and should be interpreted with caution. No clear differences in OHRQoL, patient satisfaction, or esthetics were identified.</p><p><strong>Conclusions: </strong>Based on the available evidence, non-metal RBFPDs and SR-RBFPDs may be considered viable treatment options compared with metal and/or TR-RBFPDs. However, the current evidence is limited and applies primarily to anterior single-tooth loss. Further well-designed clinical studies are required to clarify the indications and long-term outcomes of SR-RBFPDs.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":""},"PeriodicalIF":3.8,"publicationDate":"2026-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"148456116","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Intra- and inter-examiner reliability of an occlusal force-measuring device equipped with a capacitive-type pressure-mapping sensor sheet.","authors":"Yoshihiro Kugimiya, Masaharu Murakami, Yu Nakano, Honoka Sato, Sae Nagai, Junya Nakamura","doi":"10.2186/jpr.JPR_D_25_00164","DOIUrl":"10.2186/jpr.JPR_D_25_00164","url":null,"abstract":"<p><strong>Purpose: </strong>To clarify the intra- and inter-examiner reliability of an occlusal force-measuring device equipped with a capacitive-type pressure-mapping sensor sheet in older adults.</p><p><strong>Methods: </strong>Thirty-eight individuals (23 women) aged ≥65 (mean ± SD: 79.3±6.1) years were included. The numbers of present and functional teeth were visually examined. Occlusal force was measured using the Oramo-bf device (Sumitomo Riko Co., Aichi, Japan). To evaluate intra-examiner reliability, one dentist measured each participant's occlusal force thrice and calculated the intraclass correlation coefficient (ICC; case 1) and the coefficient of variation (CV). To examine inter-examiner reliability, three dentists measured the occlusal force once per participant and calculated the ICC case 2.</p><p><strong>Results: </strong>The median (first quartile-third quartile [Q1-Q3]) numbers of present and functional teeth were 22.5 (18-27) and 28 (26-28), respectively. The median (Q1-Q3) occlusal force measured by a single examiner across the measurements was 604.8 (261.7-731.5) N. The ICC for a single measurement by one examiner based on all three measurements per participant was 0.982 (95% confidence interval [CI]: 0.969-0.990). The ICC (1,3) for the mean of three repeated measurements by one examiner was 0.994 (95% CI: 0.990-0.997). The mean ± SD CV was 0.052 ± 0.046. The ICC (2,1) for inter-examiner reliability was 0.950 (95% CI: 0.917-0.972).</p><p><strong>Conclusions: </strong>This study revealed high intra- and inter-examiner reliability of measurements obtained using an occlusal force-measuring device equipped with a capacitive-type pressure-mapping sensor sheet. This device may provide reliable results with a single measurement, regardless of the examiner.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"398-403"},"PeriodicalIF":3.8,"publicationDate":"2026-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145437835","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Rune Shibata, Jasper Kim, Jeong Kim, Nicholas Her, Keiji Komatsu, Takanori Matsuura, Akiko Yoneda, Justin Choi, Denny Chao, Takahiro Ogawa
{"title":"Cementing innovation: High-energy titanium abutments via UV photofunctionalization unlock superior crown retention.","authors":"Rune Shibata, Jasper Kim, Jeong Kim, Nicholas Her, Keiji Komatsu, Takanori Matsuura, Akiko Yoneda, Justin Choi, Denny Chao, Takahiro Ogawa","doi":"10.2186/jpr.JPR_D_25_00143","DOIUrl":"10.2186/jpr.JPR_D_25_00143","url":null,"abstract":"<p><strong>Purpose: </strong>Evaluation of the impact of ultraviolet (UV) photofunctionalization on titanium-cement interfaces, specifically its ability to transform titanium into a high-energy surface and enhance crown retention.</p><p><strong>Methods: </strong>Commercial titanium abutments (standard: 4.0 mm; long: 5.5 mm) were treated with vacuum UV (VUV) light at 172 nm for 1 min. Milled polymethyl methacrylate crowns were cemented using resin-modified glass ionomer cement. Tensile testing quantified the maximum tensile load and interfacial energy. Surface changes were analyzed using contact angle measurements and X-ray photoelectron spectroscopy (XPS). Post-failure interfaces were examined via scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX).</p><p><strong>Results: </strong>UV-treated standard-length abutments exhibited a 4.1-fold increase in maximum tensile load and 27-fold increase in bonding energy compared with untreated control counterparts. UV-treated long abutments showed a 4.6-fold increase in maximum tensile load and 54-fold increase in bonding energy. UV treatment rendered the titanium surface superhydrophilic and low in carbon, whereas untreated specimens remained carbon-rich and hydrophobic. UV-treated long abutments exhibited 3.1-fold higher energy than UV-treated standard abutments. Notably, long abutments without UV treatment did not outperform standard untreated abutments. SEM and EDX confirmed extensive residual cement on UV-treated abutments, indicating cohesive failure and strong interfacial bonding.</p><p><strong>Conclusions: </strong>A 1-min UV photofunctionalization transforms titanium into a superhydrophilic, high-energy surface that significantly enhances cement bonding. This physicochemical surface strategy outperforms geometric modifications alone. As a rapid, non-invasive approach, UV photofunctionalization may establish a new standard for durable implant-supported restorations, reducing prosthetic failure and influencing both material selection and clinical and laboratory workflows.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"383-397"},"PeriodicalIF":3.8,"publicationDate":"2026-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145185861","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Development of a device for continuous salivary pH measurement at two locations in the oral cavity.","authors":"Thida Aung, Hiroshi Churei, Kairi Hayashi, Kazuyoshi Tsuchiya, Kazuma Sasaki, Gen Tanabe, Toshiaki Ueno, Kenji Fueki","doi":"10.2186/jpr.JPR_D_25_00145","DOIUrl":"10.2186/jpr.JPR_D_25_00145","url":null,"abstract":"<p><strong>Purpose: </strong>Conventional handheld pH meters have measurement limitations. Therefore, this study aimed to continuously measure the salivary pH at two intraoral locations using a newly developed sensor system.</p><p><strong>Methods: </strong>In this pilot study, we developed custom-made intraoral mouthguards (MG) with two pH sensors in the anterior region (Channel 1: Ch1) and the buccal side of the maxillary molar (Channel 2: Ch2) to continuously monitor salivary pH at two different locations in the oral cavity.</p><p><strong>Results: </strong>The coefficient of determination (R<sup>2</sup>) for all MG sensor measurements was ≥0.99, with a high level of accuracy. Both sensor channels exhibited similar mean pH values for standard solutions, with small and constant variations. However, notable unstable differences in intraoral measurements were observed during rehydration owing to positional differences. Nonetheless, the MG sensors demonstrated excellent reliability with consistently high Intraclass Correlation Coefficients ranging from 0.977 to 0.999.</p><p><strong>Conclusions: </strong>This pilot study provides valuable insights into salivary pH fluctuations, particularly during exercise, through continuous measurements using a sensor system for the simultaneous acquisition of real-time data from different anatomical sites. These results emphasize the potential of developing an intraoral sensor system that can detect subtle variations in salivary pH.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"414-423"},"PeriodicalIF":3.8,"publicationDate":"2026-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145900759","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Elucidation of the bonding mechanism of acidic and sulfur-based monomers to heat-treated copper-containing gold alloys.","authors":"Kosuke Takehana, Haruto Hiraba, Hiroyasu Koizumi, Takayuki Yoneyama","doi":"10.2186/jpr.JPR_D_25_00233","DOIUrl":"10.2186/jpr.JPR_D_25_00233","url":null,"abstract":"<p><strong>Purpose: </strong>To elucidate how the combination of acidic and sulfur-based monomers enhances bonding to oxidized noble metal alloy surfaces.</p><p><strong>Methods: </strong>Two types of gold alloys were used: one with a low copper content (DG) and the other with a high copper content (IV). Three primers were used: a sulfur-based monomer primer (VP), a phosphate-based acidic monomer primer (PZ), and a combination of both (MC). Two conditions were used: heated and non-heated. The shear bond strengths before and after thermocycling were determined and compared for each condition. Surface chemical analysis was performed using X-ray photoelectron spectroscopy (XPS).</p><p><strong>Results: </strong>After thermocycling, the bond strength of MC was significantly higher than that of the VP under all conditions. In the comparison of alloys under heating conditions, IV showed a significantly higher bond strength than that of DG for the PZ and MC groups. XPS revealed peaks attributed to copper oxide (CuO) formation on the heated IV surface.</p><p><strong>Conclusions: </strong>Multipurpose primers are effective for bonding oxidized noble metal alloys and acrylic resins. The formation of CuO improves the performance of 10-methacryloyloxydecyl dihydrogen phosphate, and its combination with sulfur-based monomers is particularly effective for noble metal alloy surfaces with high copper content.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"478-486"},"PeriodicalIF":3.8,"publicationDate":"2026-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145900211","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Factors associated with the risk of fracture of mandibular overdentures on one or two implants: Findings from a 5-year follow-up.","authors":"Cláudio Rodrigues Leles, Lucas Peixoto Silva, Nilva Oliveira Martins, Lays Noleto Nascimento, Isabela Kattan Fontinele Azevedo, Gerald McKenna, Murali Srinivasan","doi":"10.2186/jpr.JPR_D_24_00205","DOIUrl":"10.2186/jpr.JPR_D_24_00205","url":null,"abstract":"<p><strong>Purpose: </strong>This was a prospective study conducted alongside a randomized controlled trial (RCT) that evaluated the incidence of fractures and associated risk factors in single-implant overdentures (1-IOD) compared with two-implant overdentures (2-IOD).</p><p><strong>Methods: </strong>The participants received either a mandibular 1-IOD or 2-IOD (attachments: Straumann® retentive anchor and elliptical titanium matrix with gold insert; implants: 4.1 mm diameter, Straumann® Standard Plus SLActive® Regular Neck), within the context of a randomized clinical trial. The primary outcome of interest was the incidence of IOD fractures at 5-year follow-up. Prosthetic factors, such as area and cervico-incisal height in the attachment region, and volume at the inter-canine region, were measured. Patient-related factors including age, sex, handgrip strength, manual dexterity, bite force, and chewing performance were assessed. Data analysis included descriptive statistics, bivariate tests, Kaplan-Meier plots, and linear discriminant analysis with log<sub>10</sub> transformation for variable normalization.</p><p><strong>Results: </strong>A total of 47 patients were recruited, and 34 (n = 34, 1-IOD = 16, 2-IOD = 18; mean-age: 63.9 ± 8.6 years; 79.4% women) completed the 5-year follow-up. There were no differences in the incidence of fractures between the 1-IOD and 2-IOD groups (P < 0.05). Fractures were more frequent in younger patients, and reduced cervico-incisal IOD height was significantly associated with fractures (P = 0.040). Linear discriminant analysis predicted fractures with 84.4% accuracy and identified cervico-incisal height and age as key predictors.</p><p><strong>Conclusions: </strong>There were no significant differences in the incidence of overdenture fractures between groups. Reduced cervico-incisal denture height in the attachment region of ball-retained IODs was associated with mandibular IOD fractures. Further studies with larger cohorts are recommended to identify additional risk factors for mandibular IODs.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"373-382"},"PeriodicalIF":3.8,"publicationDate":"2026-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145206620","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Effect of tightening protocols on abutment screw loosening and morphological changes in two-piece zirconia implants: A comparative study using cyclic torsional loading.","authors":"Toma Hara, Takayuki Sugiki, Munetsugu Seto, Kazuhiko Ueda","doi":"10.2186/jpr.JPR_D_25_00249","DOIUrl":"10.2186/jpr.JPR_D_25_00249","url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluates the effects of different abutment screw tightening protocols and implant materials on screw loosening and morphological changes after cyclic torsional loading of two-piece implants.</p><p><strong>Methods: </strong>Titanium (T) and zirconia (Z) two-piece implants were used. Abutment screws were tightened to 35 Ncm. Three protocols were tested: (A) retightening after 5 min, (B) immediate retightening, and (C) no retightening (n = 6 each). All samples underwent 100,000 cycles of cyclic torsional loading. Removal torque values before and after loading (RT-pre and RT-post) and torque loss percentage (TL) were calculated. Surface morphology was assessed using scanning electron microscopy (SEM), and dimensional changes were quantified using root mean square (RMS) values from three-dimensional data.</p><p><strong>Results: </strong>In the titanium group, protocol A (TA) had lower RT-post values than protocols B (TB) and C (TC) (P < 0.001), and TB was lower than TC (P < 0.05). In the zirconia group, protocol A (ZA) was significantly lower than protocols B (ZB) and C (ZC) (P < 0.05, P < 0.001, respectively). RT-post and RT-pre were significantly lower in the zirconia group than in the titanium group under all conditions (P < 0.001). No differences were observed in TL. SEM revealed wear on the screw heads and threads in all groups. RMS values were significantly lower in the zirconia group (P < 0.05).</p><p><strong>Conclusions: </strong>Abutment screw retightening does not consistently enhance torque maintenance under torsional loading. The implant material affects torque retention and deformation, where titanium implants demonstrating greater stability than zirconia implants.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"468-477"},"PeriodicalIF":3.8,"publicationDate":"2026-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145917778","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Impacts of clinical factors on accuracy in static, dynamic, and robotic-assisted implant surgery: A comparative narrative review.","authors":"Angkoon Khaohoen, Nobuhiro Yoda, Pinyo Puangmali, Chaiy Rungsiyakull, Pimduen Rungsiyakull","doi":"10.2186/jpr.JPR_D_25_00079","DOIUrl":"10.2186/jpr.JPR_D_25_00079","url":null,"abstract":"<p><strong>Purpose: </strong>This review examined clinical and technological factors that influence implant placement accuracy in computer-assisted implant surgery (CAIS) systems.</p><p><strong>Study selection: </strong>A systematic search of PubMed, Scopus, and Embase identified English-language studies published between January 2015 and January 2025. The eligible studies included randomized controlled trials, observational studies, systematic reviews, in vitro investigations, and case reports. Data extraction focused on the coronal, apical, and angular deviations. Methodological quality was appraised using the Oxford Centre for Evidence-Based Medicine (CEBM) framework and validated bias assessment tools.</p><p><strong>Results: </strong>Fifty-three studies were included. Accuracy was influenced by patient-related factors (arch type, bone density, and edentulous span), surgical variables (flap design, operator experience, and guide protocol), and technological parameters (imaging modality, fiducial markers, and calibration). Static systems achieved high accuracy in dentate cases with stable guide support, but were less reliable in posterior or edentulous jaws. Dynamic navigation provided intraoperative flexibility and consistent performance across arches, although outcomes depended on calibration precision and operator learning curves. Robotic-assisted systems achieved the lowest mean deviations through trajectory control and haptic feedback, although evidence remains limited to early clinical and in vitro studies.</p><p><strong>Conclusions: </strong>Although all CAIS systems achieve high accuracy, their performance varies according to the design of the system and clinical context. Static systems are effective when stabilization is ensured, while dynamic navigation offers adaptable accuracy across scenarios, and robotics exhibit the greatest consistency by reducing operator variability. Further multicenter randomized trials and standardized reporting are needed to strengthen the available evidence and guide clinical selection.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"354-372"},"PeriodicalIF":3.8,"publicationDate":"2026-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145900295","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Shicheng Song, Xiaoying Gou, Huihui Zhang, Yongchao Xu, Huan Liu
{"title":"Motion-DSD: AI-assisted dynamic frontal facial simulation of digital diagnostic waxing from 2-dimensional intraoral digital smile design.","authors":"Shicheng Song, Xiaoying Gou, Huihui Zhang, Yongchao Xu, Huan Liu","doi":"10.2186/jpr.JPR_D_25_00041","DOIUrl":"10.2186/jpr.JPR_D_25_00041","url":null,"abstract":"<p><strong>Purpose: </strong>This study proposes the development of \"Motion-DSD\", an artificial intelligence-assisted workflow for digital smile design (DSD), which enables a dynamic 2-dimensional (2D) simulation of digital diagnostic waxing by transferring an intraoral design onto a frontal facial video, and validates its clinical feasibility.</p><p><strong>Methods: </strong>A total of 2,000 facial and 190 intraoral images were used to fine-tune the pre-trained neural network, Segment Anything model (SAM), via two sets of low-rank adaptation (LoRA) modules for facial structures and teeth segmentation respectively. A transformation algorithm incorporating a \"standard\" facial image was developed to align intraoral and facial structures. A Flask-based web user interface (web-UI) was developed for clinical deployment. A participant sample set was prepared to validate the workflow's performance in a clinical setting.</p><p><strong>Results: </strong>Two fine-tuned SAMs achieved robust segmentation performance, with a mean Dice score coefficient of 0.886 for the facial dataset and 0.969 for the intraoral dataset. The alignment algorithm effectively transferred the intraoral DSD design onto the participant's frontal facial video and enabled a 2D simulation of digital diagnostic waxing under various facial expressions, demonstrating its clinical feasibility. The web-UI allows dentists to interactively refine the design and preview simulation results in real time.</p><p><strong>Conclusions: </strong>Motion-DSD enables the 2D simulation of digital diagnostic waxing from intraoral DSD designs in a dynamic facial context. The workflow overcomes the limitations of static imaging methods and manual alignment, bringing dynamics prior to the physical mockup phase. Further investigations are warranted to quantitatively validate the simulation accuracy and demonstrate its potential advantages over conventional static methods.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"404-413"},"PeriodicalIF":3.8,"publicationDate":"2026-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145917907","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Enhancing the bonding strength of PEEK through chemical modification with UV/ozone treatment.","authors":"Mina Takita, Kosuke Nozaki, Shiho Otake, Shinya Oishi, Taisuke Ozaki, Wataru Komada, Kenji Fueki","doi":"10.2186/jpr.JPR_D_25_00062","DOIUrl":"10.2186/jpr.JPR_D_25_00062","url":null,"abstract":"<p><strong>Purpose: </strong>Polyetheretherketone (PEEK), a high-performance thermoplastic polymer, has been explored as a dental material because of its excellent mechanical strength and biocompatibility. Composite resin has been reported as a viable prosthetic material when appropriate surface treatment is applied to PEEK. We evaluated the effects of ultraviolet and ozone (UV/ozone) irradiation on the bond strength of PEEK.</p><p><strong>Methods: </strong>Eighty-six rectangular PEEK specimens were fabricated and divided into two surface-pretreatment groups: untreated (CO) and UV/ozone-treated (UV). The contact angle, surface roughness, and chemical composition were analyzed using contact angle goniometry, laser scanning microscopy, and X-ray photoelectron spectroscopy (XPS), respectively. The remaining specimens were assigned to two conditioning groups: no conditioning (NT) and primer conditioning (AD). Cylindrical specimens fabricated by Computer-Aided Design, Computer-Aided Manufacturing (CAD-CAM) composite resin blocks were bonded to the PEEK surface using resin cement. Half of the specimens in each group were subjected to 5000 thermal cycles. The shear bond strength was tested using a universal testing machine and the fracture surfaces were examined under a stereomicroscope. Statistical analyses were performed using t-tests (α = 0.05).</p><p><strong>Results: </strong>UV/ozone treatment significantly reduced the contact angle, improved the surface wettability, and caused slight changes in the surface roughness. XPS analysis revealed a decrease in the C=O bonds and an increase in the C-OH bonds in the UV/ozone-treated group. The shear bond strength improved significantly, particularly in the AD group.</p><p><strong>Conclusions: </strong>UV/ozone treatment of PEEK surfaces increased the wettability and significantly improved the shear bond strength of the composite resin blocks.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"487-494"},"PeriodicalIF":3.8,"publicationDate":"2026-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145917853","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}