Journal of Laboratory and Clinical Medicine最新文献

筛选
英文 中文
Serum levels of C-reactive protein and procalcitonin in critically ill patients with cirrhosis of the liver 肝硬化危重患者血清c反应蛋白和降钙素原水平的研究
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/j.lab.2005.08.005
Daliana Peres Bota, Marc Van Nuffelen, Ahmed N. Zakariah, Jean-Louis Vincent
{"title":"Serum levels of C-reactive protein and procalcitonin in critically ill patients with cirrhosis of the liver","authors":"Daliana Peres Bota,&nbsp;Marc Van Nuffelen,&nbsp;Ahmed N. Zakariah,&nbsp;Jean-Louis Vincent","doi":"10.1016/j.lab.2005.08.005","DOIUrl":"10.1016/j.lab.2005.08.005","url":null,"abstract":"<div><p><span>Concentrations of C-reactive protein (CRP) and procalcitonin (PCT) have been suggested as markers of infection. The liver is believed to be a key source of CRP and PCT. For this reason we assessed the predictive value of these markers in patients with hepatic cirrhosis in a 31-bed university-hospital department of intensive care. Demographic, clinical, laboratory, and microbiologic data were collected prospectively over 9 months. Of 864 patients included in the study, 79 (9%) had hepatic cirrhosis. Patients with cirrhosis were more likely to have a medical than a surgical admission diagnosis (67 vs 47%, </span><em>P</em> = .03). They also had a higher rate of infection (48 vs 30%, <em>P</em> = .03) and higher mortality (44 vs 17%, <em>P</em><span> = .01) than did patients without cirrhosis. We detected no differences in CRP and PCT concentrations among patients with cirrhosis and different disease severity as assessed on the basis of Child-Pugh score. The serum CRP concentration (admission 11.2 ± 4.6 vs 13.0 ± 5.8, maximum 13.9 ± 6.4 vs 18.8 ± 7.3 mg/dL) and PCT (admission 1.3 ± 0.9 vs 2.0 ± 1.4, maximum 3.3 ± 1.8 vs 3.4 ± 2.1 ng/mL) were slightly lower in infected patients with cirrhosis than in infected patients without cirrhosis, but the differences were not statistically significant. Although the liver is considered the main source of CRP and a source of PCT, serum levels of these acute-phase proteins are not significantly lower in patients with cirrhosis than in other patients. Moreover, the predictive power of CRP and PCT for infection was similar for patients with and without cirrhosis.</span></p></div>","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Pages 347-351"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lab.2005.08.005","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25710511","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 128
About the cover illustration: The quack doctor 关于封面插图:江湖医生
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/j.lab.2005.11.002
Dale E. Hammerschmidt MD (Editor-in-Chief)
{"title":"About the cover illustration: The quack doctor","authors":"Dale E. Hammerschmidt MD (Editor-in-Chief)","doi":"10.1016/j.lab.2005.11.002","DOIUrl":"10.1016/j.lab.2005.11.002","url":null,"abstract":"","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Pages 352-353"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lab.2005.11.002","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25710512","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
This month in J Lab Clin Med 本月在J Lab临床医学杂志上
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/j.lab.2005.11.001
Dale E. Hammerschmidt MD (Editor-in-Chief)
{"title":"This month in J Lab Clin Med","authors":"Dale E. Hammerschmidt MD (Editor-in-Chief)","doi":"10.1016/j.lab.2005.11.001","DOIUrl":"https://doi.org/10.1016/j.lab.2005.11.001","url":null,"abstract":"","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Pages 309-311"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lab.2005.11.001","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136502654","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Stability of blood cell counts, hematologic parameters and reticulocytes indexes on the Advia A120 hematologic analyzer Advia A120血液分析仪血细胞计数、血液学参数和网织红细胞指标的稳定性
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/j.lab.2005.08.004
Giuseppe Lippi , Gian Luca Salvagno , Gian Pietro Solero , Massimo Franchini , Gian Cesare Guidi
{"title":"Stability of blood cell counts, hematologic parameters and reticulocytes indexes on the Advia A120 hematologic analyzer","authors":"Giuseppe Lippi ,&nbsp;Gian Luca Salvagno ,&nbsp;Gian Pietro Solero ,&nbsp;Massimo Franchini ,&nbsp;Gian Cesare Guidi","doi":"10.1016/j.lab.2005.08.004","DOIUrl":"10.1016/j.lab.2005.08.004","url":null,"abstract":"<div><p>Delayed sample analysis is not a rare circumstance in clinical and laboratory practice, especially when blood samples are shipped to distant centralized laboratories, when the analysis can not be readily performed, or when retesting is appropriate. In this study we sought to evaluate the stability of conventional and new hematologic parameters in blood specimens stored for as long as 24 hours at 4°C. Of the 21 hematologic parameters tested with the use of the Advia 120 hematologic analyzer (Bayer Diagnostics), means for paired samples of specimens differed significantly over the 24-hour storage period for hematocrit, main corpuscular volume, percentage of macrocytes, platelet count, main platelet volume, reticulocyte count and percentage, and reticulocyte hemoglobin content (all <em>P</em> &lt; .01). We noted no significant changes in the other parameters tested or in the white blood cell differential. The overall distribution of the immature reticulocytes fractions remained substantially unchanged, though the high staining-intensity fraction showed a considerable shift from the baseline measure. Bland-Altman plots and limits-of-agreement analysis showed mean biases between −4.8% and 37.2% and relative coefficients of variations ranging from 0.4% to 32.7%. The 95% agreement interval in the set of differences was satisfactory and almost within the current analytic-quality specifications for desirable bias. The results of this investigation suggest that, within certain limitations for parameters derived or calculated from cellular volumes, blood specimens stored for as long as 24 hours at 4° C may be suitable for hematologic testing.</p></div>","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Pages 333-340"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lab.2005.08.004","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25710509","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 68
Influence of hypoalbuminemia or hyperalbuminemia on the serum anion gap 低白蛋白血症或高白蛋白血症对血清阴离子间隙的影响
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/j.lab.2005.07.008
Mark Feldman, Nilam Soni, Beverly Dickson
{"title":"Influence of hypoalbuminemia or hyperalbuminemia on the serum anion gap","authors":"Mark Feldman,&nbsp;Nilam Soni,&nbsp;Beverly Dickson","doi":"10.1016/j.lab.2005.07.008","DOIUrl":"10.1016/j.lab.2005.07.008","url":null,"abstract":"<div><p>Background: Conflicting data exist as to what extent hypoalbuminemia reduces the anion gap; estimates range from 1.5 to 2.5 mM per g/dL decrease in serum albumin. Methods: We measured serum albumin, total protein, and electrolyte concentrations in 5328 consecutive patients aged 1 month to 102 years. Most patients (3750; 70%) had a normal albumin, but 1158 had hypoalbuminemia (≤3.4 g/dL); 420 had hyperalbuminemia (≥4.7 g/dL). Relationships between serum albumin or total protein and the anion gap were analyzed by linear regression. Results: 309 (27%) hypoalbuminemic patients had a decreased anion gap, and 257 hyperalbuminemic patients (61%) had an increased anion gap. Among the entire group of 5328 patients, there were highly significant correlations between either serum albumin or total protein and the anion gap (<em>P</em> &lt; 0.001). The slope of the regression for albumin versus anion gap was 2.3 mM per g/dL. Using this slope, anion gap could be adjusted for abnormal serum albumin levels: anion gap<sub>adjusted</sub> =anion gap + 2.3 (4-albumin). The initial assessment of an anion gap as being increased, normal, or decreased changed in 44% of the patients with hypo- or hyperalbuminemia once anion gap had been adjusted with this formula. Conclusions: Before considering whether a disorder associated with an increased or decreased anion gap is present, the anion gap should be first adjusted for abnormal serum albumin concentrations. Our data suggest that physicians use 2.3 times the change in serum albumin, whereas those of Figge et al suggest 2.5; either approach gives similar results.</p></div>","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Pages 317-320"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lab.2005.07.008","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25710561","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 96
Differential regulation of the rat heme oxygenase-1 expression by Ets oncoproteins in glomerular mesangial cells Ets癌蛋白对大鼠肾小球系膜细胞血红素氧化酶-1表达的差异调控
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/j.lab.2005.07.012
Prasad D.K. Dhulipala , Prasun K. Datta , E. Shyam Reddy , Elias A. Lianos
{"title":"Differential regulation of the rat heme oxygenase-1 expression by Ets oncoproteins in glomerular mesangial cells","authors":"Prasad D.K. Dhulipala ,&nbsp;Prasun K. Datta ,&nbsp;E. Shyam Reddy ,&nbsp;Elias A. Lianos","doi":"10.1016/j.lab.2005.07.012","DOIUrl":"10.1016/j.lab.2005.07.012","url":null,"abstract":"<div><p>The Ets-1 oncoprotein and the heme-catabolizing enzyme heme oxygenase (HO)-1 have been implicated in the pathogenesis of renal disease. We investigated the role of the putative Ets-binding sites (EBSs) in the transactivation of the proximal promoter of rat heme oxygenase 1 (<em>hmox1</em>) gene by the Ets oncoproteins Fli-1, Erg-2, and Ets-1 in mesangial cells. We examined several rat <em>hmox1</em>-chloramphenicol acetytransferase (CAT) constructs and EBS mutant constructs in an effort to assess the effect of ETS oncoproteins on transactivation of the rat <em>hmox1</em> proximal promoter in renal glomerular mesangial cells. CAT assays demonstrated that the proximal promoter region (−1387 to −40) contains positive and negative regulatory regions and that the EBS-2, 3, and 4 play a role in basal promoter activity. Overexpression of Fli-1 and Erg-2 proteins showed a significant increase in promoter activity, whereas Ets-1 showed no effect on promoter activity. The Fli-1–induced transcriptional activation was not altered by mutation of EBSs, either independently or in combination. However, mutation of EBS-4 independently or a combined mutation of sites 3 and 4 led to a 50% reduction in Erg-2–induced transcriptional activation. Furthermore, mutation of EBS-2 and 4 completely abolished Erg-2–mediated promoter activation. Our results support a role for Ets transcription factors in the regulation of rat <em>hmox-1</em> gene expression in mesangial cells.</p></div>","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Pages 326-332"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lab.2005.07.012","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25710563","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Laboratory testing for the antibodies that cause heparin-induced thrombocytopenia: How much class do we need? 肝素诱导的血小板减少症抗体的实验室检测:我们需要多少类?
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/j.lab.2005.08.003
Theodore E. Warkentin , Jo-Ann I. Sheppard , Jane C. Moore , Kathleen M. Moore , Christopher S. Sigouin , John G. Kelton
{"title":"Laboratory testing for the antibodies that cause heparin-induced thrombocytopenia: How much class do we need?","authors":"Theodore E. Warkentin ,&nbsp;Jo-Ann I. Sheppard ,&nbsp;Jane C. Moore ,&nbsp;Kathleen M. Moore ,&nbsp;Christopher S. Sigouin ,&nbsp;John G. Kelton","doi":"10.1016/j.lab.2005.08.003","DOIUrl":"10.1016/j.lab.2005.08.003","url":null,"abstract":"<div><p>Heparin-induced thrombocytopenia (HIT) is usually caused by platelet-activating antibodies of immunoglobulin G class that recognize platelet factor-4 (PF4) bound to heparin or certain other polyanions. Commercial enzyme immunoassays (EIAs) for PF4/polyanion-reactive antibodies detect two immunoglobulin classes (IgA and IgM) besides IgG. To investigate whether the additional detection of these antibody classes improves or worsens assay operating characteristics, we compared the sensitivity and specificity of EIAs that detect these 3 immunoglobulin classes individually with that of a commercial EIA (Genetic Testing Institute, GTI), as well as a platelet-activation assay, the serotonin-release assay (SRA). We compared the operating characteristics of these 5 assays by evaluating 448 patients, in 14 of whom clinical HIT developed, who received either unfractionated or low molecular weight heparin in prospective studies that included systematic platelet-count monitoring and serologic evaluation for anti-PF4/polyanion antibodies. We found that the SRA and IgG and commercial EIAs had similar high sensitivity for HIT; however, diagnostic specificity (for unfractionated and low molecular weight heparin, respectively) varied considerably, as follows: SRA (95.1%, 97.2%) &gt; IgG EIA (89.0%, 93.7%) &gt; GTI EIA (74.2%, 87.6%). Additional detection of IgA and IgM antibodies by the GTI EIA worsened test specificity by detecting numerous nonpathogenic antibodies. Moreover, the frequency and magnitude of IgA and IgM antibody formation in non-HIT immune responses did not differ from that exhibited by patients in whom clinical HIT developed. We conclude that an EIA that detects anti-PF4/polyanion antibodies of only the IgG class has greater diagnostic usefulness in revealing clinical HIT than does an assay that also detects IgA and IgM class antibodies.</p></div>","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Pages 341-346"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lab.2005.08.003","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25710510","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 251
From the molecular genetics revolution to gene therapy: Translating basic research into medicine 从分子遗传学革命到基因治疗:将基础研究转化为医学
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/j.lab.2005.07.009
James A. Marcum
{"title":"From the molecular genetics revolution to gene therapy: Translating basic research into medicine","authors":"James A. Marcum","doi":"10.1016/j.lab.2005.07.009","DOIUrl":"10.1016/j.lab.2005.07.009","url":null,"abstract":"","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Pages 312-316"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lab.2005.07.009","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25710560","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Information for readers 读者资讯
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/S0022-2143(05)00365-3
{"title":"Information for readers","authors":"","doi":"10.1016/S0022-2143(05)00365-3","DOIUrl":"https://doi.org/10.1016/S0022-2143(05)00365-3","url":null,"abstract":"","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Page CO3"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0022-2143(05)00365-3","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136502211","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Detection of RhDel in RhD-negative persons in clinical laboratory 临床实验室rhd阴性患者RhDel的检测
Journal of Laboratory and Clinical Medicine Pub Date : 2005-12-01 DOI: 10.1016/j.lab.2005.07.007
Ya-Hui Wang , Jung-Chin Chen , Kuan-Tsou Lin , Yu-Jen Lee , Yu-Fen Yang , Tsun-Mei Lin
{"title":"Detection of RhDel in RhD-negative persons in clinical laboratory","authors":"Ya-Hui Wang ,&nbsp;Jung-Chin Chen ,&nbsp;Kuan-Tsou Lin ,&nbsp;Yu-Jen Lee ,&nbsp;Yu-Fen Yang ,&nbsp;Tsun-Mei Lin","doi":"10.1016/j.lab.2005.07.007","DOIUrl":"10.1016/j.lab.2005.07.007","url":null,"abstract":"<div><p>The Rhesus (Rh) blood group is the most polymorphic human blood group system, and it is clinically significant in transfusion medicine. About 15% of Caucasoid people are RhD-negative, whereas in the Asian population, the RhD-negative blood type only occurs in 0.1% to 0.5%. However, approximately 30% of apparently RhD-negative Taiwanese people actually were RhD<sub>el</sub>. Traditionally, we verify RhD<sub>el</sub> by a serologically adsorption-elution procedure with polyclonal anti-D. In our recent report, RhC phenotype is highly associated with RhD<sub>el</sub>, and <em>RHD</em>1227A is a useful genetic marker for RhD<sub>el</sub>. For setting up a rapid protocol to detect RhD<sub>el</sub> in clinical laboratory, a total number of 395 Taiwanese serological RhD-negative blood samples, those with RhC (+) phenotypes as selected by serological tests, were further screened by adsorption/elution tests and <em>RHD</em>1227A allele by specific sequence primer-polymerase chain reaction (SSP-PCR) for RhD<sub>el</sub>. Among 395 blood samples collected from RhD-negative subjects, the incidence of RhC (+) was 43% (171/395). One hundred and twenty six of the 171 RhC (+) samples were positive for both adsorption/elution for RhD detection and SSP-PCR assay for <em>RHD</em>1227A. The sensitivity and specificity were 96.9% and 97.5%, respectively, for <em>RHD</em>1227A detection as compared with the traditional adsorption/elution test. Our results also indicated that <em>RHD</em>1227A was highly linked to Ce haplotypes (95.2%). In conclusion, combined RhC (+) phenotyping and <em>RHD</em>1227A analysis can be a simple and accurate laboratory screening protocol for RhD<sub>el</sub> detection in RhD-negative population.</p></div>","PeriodicalId":16273,"journal":{"name":"Journal of Laboratory and Clinical Medicine","volume":"146 6","pages":"Pages 321-325"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.lab.2005.07.007","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"25710562","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 19
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信