2011 International Conference on Power and Energy Systems最新文献

筛选
英文 中文
Estimation of sulphur compounds in transformer oil 变压器油中硫化物的测定
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156693
A. Akshatha, J. S. Rajan, G. Viswanath, D. Ravindara, C. Naidu, K. Singh
{"title":"Estimation of sulphur compounds in transformer oil","authors":"A. Akshatha, J. S. Rajan, G. Viswanath, D. Ravindara, C. Naidu, K. Singh","doi":"10.1109/ICPES.2011.6156693","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156693","url":null,"abstract":"Corrosion of copper conductors in transformers is a major problem affecting the paper-oil insulation, ultimately leading to failure of transformers. Hence there is a growing concern on the issues like quality of oil, transformer design and its service conditions. Sulphur compounds are believed to be responsible for formation of semi conducting copper sulphide in paper insulation. This paper discusses the results of transformer oil drawn from different transformers of Power utilities in terms of total sulphur, mercaptan sulphur and DGA","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126041862","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Improvement of dynamic performance of three area thermal system under deregulated environment using AC tieline parallel with HVDC link 用交流与直流并联的方法改善放松管制环境下三区热力系统的动态性能
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156607
T. Kumar, V. Krishna, N. Ramana
{"title":"Improvement of dynamic performance of three area thermal system under deregulated environment using AC tieline parallel with HVDC link","authors":"T. Kumar, V. Krishna, N. Ramana","doi":"10.1109/ICPES.2011.6156607","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156607","url":null,"abstract":"This paper presents an analysis on dynamic performance of a three-area thermal system interconnected with AC tie-line parallel with HVDC link when subjected to parametric uncertainties. In this paper all the three areas consists of thermal power plants. The AC tie-line parallel with HVDC link is used as a system interconnection between all the three areas. Open transmission access and the evolution of more socialised companies for generation, transmission and distribution affects the formulation of Automatic Generation Control (AGC) problem. So, the traditional three area system is modified to take into account the effect of bilateral contracts on the dynamics. It has been observed that the dynamic response of three-area interconnected thermal plants through tie-line is sluggish and degraded when compared to the dynamic response of three area interconnected thermal power plants connected through an AC tie line Parallel with HVDC link.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121830198","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Photovoltaic array based multilevel inverter for power conditioning 基于光伏阵列的多电平逆变器电力调节
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156621
S. Rajasekar, Rajesh Gupta
{"title":"Photovoltaic array based multilevel inverter for power conditioning","authors":"S. Rajasekar, Rajesh Gupta","doi":"10.1109/ICPES.2011.6156621","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156621","url":null,"abstract":"This paper proposes a photovoltaic (PV) array supported five-level cascaded H-bridge multilevel inverter (CHBMLI) based shunt active power filter (SAPF). The combined system is used for power conditioning application to improve power quality in the distribution network. The photovoltaic supported CHBMLI makes attractive solution because this inverter need isolated dc source in the dc side of the each H-bridge. The SAPF is used to compensate both reactive and harmonic components of the current drawn by the non linear load. Additionally, it also balances the supply current for unbalanced load. In this paper it is shown that the PV based multilevel inverter configured SAPF not only compensates the harmonic current, reactive power and unbalancing but also injects real power whenever it is demanded in the distribution system. The compensation and power flow control in this paper is developed based on the instantaneous power theory. The simulation results presented in this paper evidently proves the compensation capabilities and real power injection. The simulation studies are carried out under power system computer aided design PSCAD/EMTDC 4.2 environment.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"494 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121954671","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
Comparison of various Voltage Source Inverter based UPQC topologies 基于UPQC拓扑的各种电压源逆变器的比较
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156683
S. Karanki, M. Mishra, B. K. Kumar
{"title":"Comparison of various Voltage Source Inverter based UPQC topologies","authors":"S. Karanki, M. Mishra, B. K. Kumar","doi":"10.1109/ICPES.2011.6156683","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156683","url":null,"abstract":"The Unified Power Quality Conditioner (UPQC) is a custom power device, which mitigates voltage and current related power quality issues in the power distribution systems. In this paper, two new Voltage Source Inverter (VSI) topologies for UPQC application are proposed. The proposed topologies enables UPQC to have a reduced DC link voltage without compromising the compensation capability. These proposed topologies also help to match the DC link voltage requirement of the shunt and series active filters in the UPQC. In this paper the proposed UPQC topologies are compared with the existing topologies in the literature. A simulation study of the proposed topologies has been carried out and the results are presented.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131948464","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Performance study of isolated hybrid power system with multiple generation and energy storage units 多发电储能隔离混合电力系统性能研究
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156623
N. Jayalakshmi, D. N. Gaonkar
{"title":"Performance study of isolated hybrid power system with multiple generation and energy storage units","authors":"N. Jayalakshmi, D. N. Gaonkar","doi":"10.1109/ICPES.2011.6156623","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156623","url":null,"abstract":"This paper presents proportional-plus-integral (PI) controller based frequency regulation of isolated autonomous hybrid distributed generation system for sudden variation in load demand and wind. The developed hybrid system comprises of wind turbine generator (WTG), micro-turbine generator (MTG), fuel cell (FC), an aqua electrolyzer (AE) along with the energy storage device such as battery energy storage system (BESS). Further ultracapacitor (UC) as an alternative energy storage element is incorporated into the system for better performance. The generated hydrogen by an aqua electrolyzer is used as fuel for a fuel cell. The simulation results reported in the paper focused on frequency response for variable wind power, step load change and variable load.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133799170","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 22
A study of the SMIB power system model with delayed feedback 带延迟反馈的SMIB电力系统模型研究
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156660
A. B. Chowdhury, A. Kulhare, G. Raina
{"title":"A study of the SMIB power system model with delayed feedback","authors":"A. B. Chowdhury, A. Kulhare, G. Raina","doi":"10.1109/ICPES.2011.6156660","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156660","url":null,"abstract":"Our focus is on the impact that time delayed feedback can have on the stability and performance of a traditional power system model. Stability analysis has played an important role in power system models, however most of the models assume that any feedback is instantaneous. For example, in wide area measurement systems (WAMS) it would be important and realistic to incorporate time delays. Our focus will be on the impact time delayed feedback may have on the stability and performance of the single machine infinite bus (SMIB) power system model. For this model, we construct appropriate stability charts and bifurcation diagrams, which serve to exhibit the impact time delays may have on stability and performance. Our work is step towards a more systematic understanding of delayed feedback in power system models.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130687378","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
The impact of IP sets for establishment of baseline data in power distribution of electric utilities under R-APDRP IP集对R-APDRP下电力公司配电基线数据建立的影响
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156605
P. Sekhar, C. P. Jairam, T. Raghunatha, R. S. Kumar, K. Rao, V. Bharathi, Kiran. V. Madhugiri
{"title":"The impact of IP sets for establishment of baseline data in power distribution of electric utilities under R-APDRP","authors":"P. Sekhar, C. P. Jairam, T. Raghunatha, R. S. Kumar, K. Rao, V. Bharathi, Kiran. V. Madhugiri","doi":"10.1109/ICPES.2011.6156605","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156605","url":null,"abstract":"This paper presents the impact of irrigation pump sets on base line AT&C loss, impact of revenue collection and collection efficiency in the Project Area. This paper also focuses on field experience of authors during the establishment of base line data for designated Project Areas under R-APDRP Programme. This paper also brought out sample base line parameters estimation. It also emphasizes problems in the field during collecting data and attempt to overcome the problems.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114535289","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A new proposal for voltage regulation multi feeders/Multibus systems using MC-DVR 基于MC-DVR的稳压多馈线/多总线系统的新方案
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156679
P. Naidu, B. Raja
{"title":"A new proposal for voltage regulation multi feeders/Multibus systems using MC-DVR","authors":"P. Naidu, B. Raja","doi":"10.1109/ICPES.2011.6156679","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156679","url":null,"abstract":"This paper presents a new voltage regulation system multi converter dynamic voltage restorer (MC-DVR), capable of simultaneous compensation for voltage in Multibus/multifeeder systems. In this configuration two voltage-source converters (VSC) exist. The system can be applied to adjacent feeders to compensate for supply-voltage on the main feeder and full compensation of supply-voltage imperfections on the other feeders. In the proposed configuration, all converters are connected back to back on the dc side and share a common dc-link capacitor. Therefore, power can be transferred from one feeder to adjacent feeders to compensate for sag. The performance of the MC-DVR as well as the adopted control algorithm is illustrated by simulation. The results obtained in MATLAB/SIMULINK on a two-bus/two-feeder system show the effectiveness of the proposed configuration.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114223096","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Power quality improvement in DTC based induction motor drive using Minnesota rectifier 采用明尼苏达整流器改善直流感应电机驱动的电能质量
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156685
Bhim Singh, G. Bhuvaneswari, S. Madishetti
{"title":"Power quality improvement in DTC based induction motor drive using Minnesota rectifier","authors":"Bhim Singh, G. Bhuvaneswari, S. Madishetti","doi":"10.1109/ICPES.2011.6156685","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156685","url":null,"abstract":"This paper presents power quality improvement at the utility interface for a Direct Torque Controlled (DTC) induction motor drive by making use of a Minnesota rectifier. The proposed Minnesota rectifier for a 2.2 kW drive is designed, modeled and simulated in MATLAB/Simulink platform. The design of the proposed Minnesota rectifier is developed along with the necessary modifications required for making it suitable for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The performance parameters of the DTC drive fed by a 6-pulse uncontrolled converter is compared with the one fed by Minnesota rectifier for variable load conditions. The results show that the THD and power factor at the ac mains are improved perceivably even with the magnetic rating being as low as 40.94% of the drive rating.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114302120","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Neural learning algorithm based power quality enhancement for three phase three wire distribution system utilizing shunt active power filter strategy 基于神经学习算法的三相三线配电网并联有源滤波电能质量增强
2011 International Conference on Power and Energy Systems Pub Date : 2011-12-01 DOI: 10.1109/ICPES.2011.6156667
A. Kumar, P. Raj
{"title":"Neural learning algorithm based power quality enhancement for three phase three wire distribution system utilizing shunt active power filter strategy","authors":"A. Kumar, P. Raj","doi":"10.1109/ICPES.2011.6156667","DOIUrl":"https://doi.org/10.1109/ICPES.2011.6156667","url":null,"abstract":"This paper explores the application of artificial intelligence on solving the power quality problems by using the shunt active power filter strategy for three phase three wire distribution system. The unit vector template generation control technique is modeled as current controller for the shunt active power filter strategy. The proportional and integral (PI) controller is designed to minimize error between the actual and the reference DC voltage of shunt active power filter strategy. The transient period and peak overshoot of DC bus voltage using a PI controller is observed to be higher in initial and load change conditions. The artificial neural network is a powerful tool used to generate the current signal with very low oscillation and faster settling time. In this paper, a new neural learning algorithm (NAL) is proposed for the current controller of the shunt active power filter strategy. The performance of the proposed neural learning algorithm is extensively analyzed of diode rectifier RL non linear load with respect to two different operating conditions. The proposed system is designed with MATLAB/Simulink environment.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"180 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114421267","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信