{"title":"A new proposal for voltage regulation multi feeders/Multibus systems using MC-DVR","authors":"P. Naidu, B. Raja","doi":"10.1109/ICPES.2011.6156679","DOIUrl":null,"url":null,"abstract":"This paper presents a new voltage regulation system multi converter dynamic voltage restorer (MC-DVR), capable of simultaneous compensation for voltage in Multibus/multifeeder systems. In this configuration two voltage-source converters (VSC) exist. The system can be applied to adjacent feeders to compensate for supply-voltage on the main feeder and full compensation of supply-voltage imperfections on the other feeders. In the proposed configuration, all converters are connected back to back on the dc side and share a common dc-link capacitor. Therefore, power can be transferred from one feeder to adjacent feeders to compensate for sag. The performance of the MC-DVR as well as the adopted control algorithm is illustrated by simulation. The results obtained in MATLAB/SIMULINK on a two-bus/two-feeder system show the effectiveness of the proposed configuration.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPES.2011.6156679","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
This paper presents a new voltage regulation system multi converter dynamic voltage restorer (MC-DVR), capable of simultaneous compensation for voltage in Multibus/multifeeder systems. In this configuration two voltage-source converters (VSC) exist. The system can be applied to adjacent feeders to compensate for supply-voltage on the main feeder and full compensation of supply-voltage imperfections on the other feeders. In the proposed configuration, all converters are connected back to back on the dc side and share a common dc-link capacitor. Therefore, power can be transferred from one feeder to adjacent feeders to compensate for sag. The performance of the MC-DVR as well as the adopted control algorithm is illustrated by simulation. The results obtained in MATLAB/SIMULINK on a two-bus/two-feeder system show the effectiveness of the proposed configuration.