A. Akshatha, J. S. Rajan, G. Viswanath, D. Ravindara, C. Naidu, K. Singh
{"title":"变压器油中硫化物的测定","authors":"A. Akshatha, J. S. Rajan, G. Viswanath, D. Ravindara, C. Naidu, K. Singh","doi":"10.1109/ICPES.2011.6156693","DOIUrl":null,"url":null,"abstract":"Corrosion of copper conductors in transformers is a major problem affecting the paper-oil insulation, ultimately leading to failure of transformers. Hence there is a growing concern on the issues like quality of oil, transformer design and its service conditions. Sulphur compounds are believed to be responsible for formation of semi conducting copper sulphide in paper insulation. This paper discusses the results of transformer oil drawn from different transformers of Power utilities in terms of total sulphur, mercaptan sulphur and DGA","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Estimation of sulphur compounds in transformer oil\",\"authors\":\"A. Akshatha, J. S. Rajan, G. Viswanath, D. Ravindara, C. Naidu, K. Singh\",\"doi\":\"10.1109/ICPES.2011.6156693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Corrosion of copper conductors in transformers is a major problem affecting the paper-oil insulation, ultimately leading to failure of transformers. Hence there is a growing concern on the issues like quality of oil, transformer design and its service conditions. Sulphur compounds are believed to be responsible for formation of semi conducting copper sulphide in paper insulation. This paper discusses the results of transformer oil drawn from different transformers of Power utilities in terms of total sulphur, mercaptan sulphur and DGA\",\"PeriodicalId\":158903,\"journal\":{\"name\":\"2011 International Conference on Power and Energy Systems\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Power and Energy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPES.2011.6156693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPES.2011.6156693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Estimation of sulphur compounds in transformer oil
Corrosion of copper conductors in transformers is a major problem affecting the paper-oil insulation, ultimately leading to failure of transformers. Hence there is a growing concern on the issues like quality of oil, transformer design and its service conditions. Sulphur compounds are believed to be responsible for formation of semi conducting copper sulphide in paper insulation. This paper discusses the results of transformer oil drawn from different transformers of Power utilities in terms of total sulphur, mercaptan sulphur and DGA