Proceedings of the Fifteenth Annual Northeast Bioengineering Conference最新文献

筛选
英文 中文
A magnetic resonance image processing system for cardiac research 心脏研究用磁共振图像处理系统
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36732
P. Daly, W. Ohley, H. Gewirtz, R. Haas
{"title":"A magnetic resonance image processing system for cardiac research","authors":"P. Daly, W. Ohley, H. Gewirtz, R. Haas","doi":"10.1109/NEBC.1989.36732","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36732","url":null,"abstract":"Analysis of magnetic resonance images (MRI) is often limited to hardware and software provided by the manufacturer. To circumvent this problem the authors developed a Unix-based system using a Sun S3/60 workstation. They acquire multiple series of ECG (electrocardiogram) gated images. Typically in a single acquisition there are four oblique long-axis slices centered around the left ventricle (LV) at eight points during the cardiac cycle. The images are transferred to 9-track tape and decoded using Unix-based scripts so that all demographic and image data is retained. The images are loaded in the Sun system and converted to a Sun window raster format. Once in this format the images can be easily manipulated by a variety of methods. The authors provide for the cine display at 16 frames/s, contrast and pseudocolor enhancement, and 2-D LV and blood pool reconstruction. The system is thus a promising one for the manipulation and analysis of cardiac MRI data.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132345829","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Orientation aid implementing the global positioning system 定位辅助实现全球定位系统
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36684
D. Brusnighan, M. Strauss, J. Floyd, B.C. Wheeler
{"title":"Orientation aid implementing the global positioning system","authors":"D. Brusnighan, M. Strauss, J. Floyd, B.C. Wheeler","doi":"10.1109/NEBC.1989.36684","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36684","url":null,"abstract":"A portable device that enables a visually impaired traveler to determine distance and direction of travel to a desired destination point quickly and accurately is being developed. Coordinates of the traveler's current position will be determined through the use of NAVSTAR Global Positioning Systems (GPS). A microcontroller will use the coordinates obtained from a GPS receiver as a point of reference from which to calculate the distance and direction to a desired destination whose coordinates were previously stored in memory. The microcontroller will perform all the necessary mathematical operations to output sufficient information so that the traveler can reach the final destination.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132947884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 37
Control of sarcomerogenesis-growth of the heart 控制肌肉增生-心脏生长
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36672
G. Drzewiecki, E. Karam
{"title":"Control of sarcomerogenesis-growth of the heart","authors":"G. Drzewiecki, E. Karam","doi":"10.1109/NEBC.1989.36672","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36672","url":null,"abstract":"A theory for the growth of the cardiac sarcomere and heart size is proposed. The stress-strain environment and O/sub 2/ consumption are computed for the myocardium using a mechanical model of the left ventricle. Cardiac afterload and preload are maintained constant while the dimensions of the ventricle are altered. It is observed that the computed ventricular dimensions result in normal heart function, based on examination of stroke volume, heart rate, and ventricular pressure. Global quantities were not necessarily optimal. It is theorized that sarcomerogenesis is stimulated by an increase in the fiber stress along the myofibril.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122246028","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
System identification of the vestibulo-ocular reflex: application of the recursive least-squares algorithm 前庭眼反射的系统识别:递归最小二乘算法的应用
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36769
J. L. Gordon, J. Furman, E. Kamen
{"title":"System identification of the vestibulo-ocular reflex: application of the recursive least-squares algorithm","authors":"J. L. Gordon, J. Furman, E. Kamen","doi":"10.1109/NEBC.1989.36769","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36769","url":null,"abstract":"A discrete-time model of the vestibulo-ocular reflex (VOR) can be obtained by step-invariant transformation of the two-pole continuous-time model frequency used to describe the system. Simulations show that for sum-of-sines input, output predictions of the two VOR models are in agreement except during an initial period. The discrete model allows for parameter estimation by the recursive-least-squares (RLS) algorithm. RLS data yields values that are easily transformed back into continuous model parameters. RLS identification of actual data from electro-oculographic recordings is complicated by noise induced by data recording and nystagmus algorithms. Valid VOR models can be obtained by RLS without the large amounts of data required by frequency response methods.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116673421","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Spectral characterization of the myoelectric signal in infants 婴儿肌电信号的频谱特征
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36747
E. Morin, R. Scott, P. Parker, P. Mcdonnell
{"title":"Spectral characterization of the myoelectric signal in infants","authors":"E. Morin, R. Scott, P. Parker, P. Mcdonnell","doi":"10.1109/NEBC.1989.36747","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36747","url":null,"abstract":"Myoelectric signal data were recorded from infants between the ages of 6 months and 2 years and processed to determine the spectral content of the signal. The protocol for obtaining the infant myoelectric signal and processing the resultant nonstationary data is described. The results indicate that the spectral content of the infant myoelectric signal does not differ significantly from the spectral content of the adult signal. Only subtle changes in the myoelectric signal spectrum with infant age were detected.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115513678","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Calculation of epicardial potentials from a heart surface source model 心外膜电位的心表源模型计算
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36781
J. Poliner, D. Geselowitz
{"title":"Calculation of epicardial potentials from a heart surface source model","authors":"J. Poliner, D. Geselowitz","doi":"10.1109/NEBC.1989.36781","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36781","url":null,"abstract":"The authors present the development of a solution to the forward problem of calculating epicardial potentials from the underlying cardiac sources. A surface model based on a biodomain model of cardiac activity was developed and shown to be valid. The model predicted that the electric sources in the heart could be represented by a double layer with strength proportional to the transmembrane potential of cells on the surface of the heart. This double layer was spread over the epicardial and endocardial surfaces of the heart. The geometry of the surface model was a close approximation to a realistic human heart. The model was shown to predict the major features of in vivo epicardial potentials, as reported in the literature.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116555237","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Respiratory impedance spectral estimation issues for digitally created random noise from 0-4 Hz and 4-200 Hz 0- 4hz和4- 200hz数字生成随机噪声的呼吸阻抗频谱估计问题
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36736
K. Davis, K. Lutchen
{"title":"Respiratory impedance spectral estimation issues for digitally created random noise from 0-4 Hz and 4-200 Hz","authors":"K. Davis, K. Lutchen","doi":"10.1109/NEBC.1989.36736","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36736","url":null,"abstract":"The authors examine the effects of several signal processing issues on the quality of a Z/sub rs/ spectral estimate when using a finite-length random sequence created digitally and passed through a D/A (digital-to-analog) converter. The quality of the estimates was evaluated by comparing the mean of the ensemble averaged runs to the theoretical Z/sub rs/ (calculated from models) and estimating the coherence function gamma /sup 2/(f). It is shown that regardless of the SNR or model, the Z/sub rs/ estimates are superior and the gamma /sup 2/ estimates higher for 10 vs. 5 runs. Though this result was expected, the relative improvement in the mean estimate for 10 runs was substantial for a SNR below 200. Even with averaging 10 runs, however, the Z/sub rs/ and gamma /sup 2/ estimates were still poor for SNR<100 at frequencies where the magnitude of load impedance (i.e., Z/sub rs/) was high (e.g. 0-1 Hz and 128-160 Hz). At higher Z/sub rs/ the local spectral magnitude of the output flow is much lower than the average magnitude of the flow spectrum over all f/sub k/. Consequently the effective local SNR is significantly less. Again, poorer estimates were expected, but the extent of the sensitivity to noise renders the estimate useless for model fitting. Due to wider main lobe of the Hanning window, a spectral estimate at a given frequency can be biased.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114850053","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Data length effects on the coherence estimate of EEG 数据长度对脑电相干性估计的影响
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36714
S. Whiting, T. Ning, J. Bronzino
{"title":"Data length effects on the coherence estimate of EEG","authors":"S. Whiting, T. Ning, J. Bronzino","doi":"10.1109/NEBC.1989.36714","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36714","url":null,"abstract":"The coherence functions between EEGs (electroencephalograms) collected from the hippocampal subfield CA1 and dentate is reexamined by conventional (periodogram) and autoregressive (AR) approaches to study the effects of different data lengths on the performance of these approaches and the variation of the resultant magnitude squared coherence (MSC) and phase coherence estimates. The MSC and phase coherence obtained from the autoregressive method are smoother and demonstrate lower standard deviation than the results obtained by the classical approach. In general, the standard deviation of the MSC and the phase coherence decreases as data length increases, and the standard deviation of the AR method is less than that of the periodogram. The results indicate that for applications in which computational speed is not critical, the multichannel autoregressive model provides a coherence estimate that is smoother and exhibits lower standard deviation than the conventional periodogram approach.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115557402","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Suppression of sensitivity to surround motion during vergence eye movements 在会聚眼运动中对周围运动的敏感性受到抑制
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36771
G. Hung, T. Wang, K. Ciuffreda, J. Semmlow
{"title":"Suppression of sensitivity to surround motion during vergence eye movements","authors":"G. Hung, T. Wang, K. Ciuffreda, J. Semmlow","doi":"10.1109/NEBC.1989.36771","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36771","url":null,"abstract":"Suppression was investigated psychophysically in three human observers by measuring their loss of sensitivity to brief (20 ms) displacement of horizontal lines during 4 degrees convergence movements. A two-alternative forced-choice procedure was used in which the stimulus was presented either in the first or second amplitude of the displacement pulse, the time of the pulse relative to convergence onset, and the half of the trial in which the stimulus was presented were randomized. The results showed that suppression began about 200 ms before and continued until 350 ms after convergence onset, with maximum loss occurring at 25-125 ms after convergence onset. The maximum sensitivity loss was about 0.25 to 0.30 log units.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"290 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121289057","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Features for a magnetic resonance image analysis software 特点为磁共振图像分析软件
Proceedings of the Fifteenth Annual Northeast Bioengineering Conference Pub Date : 1989-03-27 DOI: 10.1109/NEBC.1989.36763
P. Sole, S. Rajagopalan, F. Delaglio, G. C. Levy
{"title":"Features for a magnetic resonance image analysis software","authors":"P. Sole, S. Rajagopalan, F. Delaglio, G. C. Levy","doi":"10.1109/NEBC.1989.36763","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36763","url":null,"abstract":"To understand the biological phenomena which influence the contrast which is observed in a magnetic resonance image, medical researchers and physicians need image-analysis methods designed to address problems specific to magnetic resonance imaging. The authors describe an approach to the design of an image analysis software intended for medical researchers working with magnetic resonance images. They explain what the constraints and requirements are for an effective implementation.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129253605","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书