{"title":"Development of ultrasonically marked needle for ultrasonically guided biopsy","authors":"K. Shung, B. Mcguire","doi":"10.1109/NEBC.1989.36729","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36729","url":null,"abstract":"It has been shown that the chances of having complications during biopsy is greatly reduced when the procedure is guided by ultrasound. However, because of the specular nature of echoes reflected by the needle, the needle tip is sometimes difficult to visualize on the ultrasound image. A number of methods have been studied to aid in the localization of the needle tip. Among them is a method by I. Cikes and B. Breyer (1984) which used a PZT crystal mounted on a catheter tip as either a passive ultrasound receiver or an active ultrasound transmitter to mark the position of the catheter tip in echocardiographically guided cardiac catheterization. This method was investigated experimentally using a piezoelectric polymer, PVDF, to mark the position of the tip of the biopsy needle. The advantage of PVDF over PZT is that it is thin, flexible, and wideband. PVDF-mounted needles have been fabricated and ultrasonically evaluated in water bath and in tissue-mimicking phantoms. Results are reported to demonstrate the feasibility of the approach and to elucidate design considerations that need to be addressed to make the device a useful clinical tool.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115139099","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Programmable interface between a cellular system and VLSI microcomputer chip","authors":"V. Bykhovsky","doi":"10.1109/NEBC.1989.36793","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36793","url":null,"abstract":"Current solid-state technology permits fabrication of an integrated silicon array chip which can generate and sense the 2-D electrical patterns as well as to store and process them. The same chip can be a substrate in a steady-operated perfusive life-support system for a cellular culture, tissue, organ, etc. (biosystem). The chip and the feeding steady-flow system form a kind of artificial environment (AE) for the biosystem. The AE can be a model for a control system specifying the biosystem activity, in particularly, the production of specific proteins. The different prospects of online pattern-directed electronic control of cellular activity are presented. This AE-biosystem combination can also be a model for an information-intensive pattern-based human-computer interface.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123056303","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Time-varying identification of the neuromuscular system. I. Human joint dynamics","authors":"J. MacNeil, R. Kearney, I. Hunter","doi":"10.1109/NEBC.1989.36743","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36743","url":null,"abstract":"A time-varying system identification technique has been developed to track abrupt changes in system characteristics using ensemble input and output records. No a priori assumptions are required regarding the system structure, form of the nonstationary, or input characteristics. A simulation study has shown the method to be capable of tracking the time course of changes in human ankle-joint dynamics associated with an abrupt change in the level of voluntary activation. The method has proved to be robust in the presence of noise.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117172988","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. T. Baldwin, J. Tarbell, S. Deutsch, D. Geselowitz
{"title":"Mean velocity measurements within a Penn State left ventricular assist device","authors":"J. T. Baldwin, J. Tarbell, S. Deutsch, D. Geselowitz","doi":"10.1109/NEBC.1989.36709","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36709","url":null,"abstract":"A laser Doppler anemometer (LDA) was used to measure two components of the mean velocity vectors at over 125 locations within a 70-cm/sup 3/ plexiglas model of the Penn State left ventricular assist device (LVAD). The model ventricle was filled with a blood analog fluid and operated at normal physiological conditions. The probe volume was positioned at the strategically selected locations along the inlet and outlet ports of the chamber and within the central volume of the pump. Mean velocities were determined at eight different times during the pump cycle averaging 250 realizations of each velocity component at the cycle times of interest. The results indicate characteristics flow patterns within the LVAD and areas which predominantly experience stasis or high velocities during the pump cycle.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127079101","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A new three-dimensional linear predictive algorithm for digital subtraction angiography","authors":"V. Digalakis","doi":"10.1109/NEBC.1989.36728","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36728","url":null,"abstract":"The authors apply a three-dimensional (3-D) linear least-squares (LS) prediction technique to the processing of digital subtraction angiography (DSA) image sequences. The main goal of this processing is the cancellation of motion artifacts, which is a visual structured noise that appears in current DSA images. Two important issues are addressed by this technique. The first is the misregistration of the mask and the contrast image. The second is the temporal filtering of the DSA image sequence. Instead of treating these two issues separately, as in conventional DSA, the authors combine them into a 3-D LS prediction problem. Based on this approach they developed an efficient algorithm for the solution of normal equations. To match the image sequence physical characteristics, the authors have further optimized practical parameters of this algorithm. Actual patient data are used for the evaluation of this technique. Results show a significant improvement over the existing methods.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116138868","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Spectral analysis of heart rate variability using diaphragmatic EMG burst activity as a time base","authors":"G. Dwyer, Y. Noguchi, H. Szeto","doi":"10.1109/NEBC.1989.36785","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36785","url":null,"abstract":"Spectral analysis of heart-rate variability (HRV) normally reveals a harmonic mode associated with breathing activity. Since this mode is locked to the breathing rate, temporal variations in breathing rate lead to a broadening of the HRV spectral peak width. It is shown that specific knowledge of breathing activity can be used to eliminate this broadening.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124095666","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Neural network design considerations for EEG spike detection","authors":"R. Eberhart, R. W. Dobbins, W. Webber","doi":"10.1109/NEBC.1989.36716","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36716","url":null,"abstract":"Neural networks are being used to analyze electroencephalogram (EEG) signals for the detection of epileptiform spikes. A review is presented of the design considerations involved in implementing a real-time spike detection system. Issues addressed are generally in two areas. The first is the characterization of the source data. For example, decisions must be made relative to data rates, the number of data channels and whether to use raw data, or preprocessed data in the form of spike parameters. The second is the selection of the neural network architecture and the specific implementation of that architecture. For example, choices must be made between supervised and unsupervised learning schemes, and among the many available network learning algorithms. A discussion is presented of interim results in an EEG spike detection project, the goal of which is to provide real-time spike detection capability for a multibed epilepsy monitoring unit.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"653 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132052907","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Principles of software for the severely physical disabled child","authors":"L. Ferrier, C. Silverman, F. Bequaert, H. Fell","doi":"10.1109/NEBC.1989.36761","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36761","url":null,"abstract":"A description is given of a population of severely physically disabled, possibly nonspeaking children, for whom a computer is the means to gaining an education, communicating with other people, and earning a living. Most, because of their poor motor control, are unable to access a computer using a standard keyboard. The authors outline some of the features which computer software must address to be used successfully by these children and their teachers. They consider the impact of recent developments in personal-computer architecture on this problem.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117009309","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The effect of diastolic function on cardiac efficiency","authors":"G.M. Drzwiecki, J.K. Li, S. Sideman, W. Welkowitz","doi":"10.1109/NEBC.1989.36673","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36673","url":null,"abstract":"A mathematical model that incorporates the basic features of the diastole is used; these features include nonlinear compliance, viscoelasticity, and active relaxation. Diastolic function is affected by shifts in the elastic pressure-volume curve. It is found that a significant change (up to +or-25%) in total efficiency can occur with shifts in diastolic function.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"89 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116441394","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Monte-Carlo study of image reconstruction for PET","authors":"S. Pavlopoulos, G. Tzanakos, M. Bhatia","doi":"10.1109/NEBC.1989.36723","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36723","url":null,"abstract":"The authors have developed a Monte Carlo program to simulate event generation of a positron-emission tomography (PET) scanner. They used it to study design parameters of a scanner and image reconstruction methods. Based on the experimental data, it is concluded that there is no need to decrease the detector size beyond a certain value because no further improvement is achieved. There should be a tradeoff as far as the filtering function is concerned, so that the resolution is as high as possible and the artifacts due to high-frequency noise are minimal.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"40 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128370626","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}