{"title":"Stability analysis of an output feedback controller for the Penn State electrical ventricular assist device","authors":"G. Klute, U. Tsach, D. Geselowitz","doi":"10.1109/NEBC.1989.36703","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36703","url":null,"abstract":"The development of a controller which minimizes the energy consumption of the implanted electric ventricular assist device (EVAD) and remains stable for the duration of the implantation is considered. The EVAD model has four state variables, only one of which is measurable in vivo. An output feedback control law that utilizes the single available state and minimizes the EVAD's energy consumption has been derived. The inclusion of the output feedback gain in the model results in a time-varying plant for which stability has to be proved. The EVAD is a pulsatile device which operates in a periodic manner. By recognizing this periodic nature, the time-varying model can be transformed into a linear time-invariant model that describes the periodic values of the system states. This linear time-variant model is used for determining whether the output feedback control law can meet the necessary and sufficient conditions for asymptotic stability.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"195 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128708247","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"An autoregulated pulsed-DC mode iontophoretic transdermal system","authors":"C. Carley, S. Wolpert, J.K. Li","doi":"10.1109/NEBC.1989.36693","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36693","url":null,"abstract":"An autoregulated pulsed-DC iontophoretic device with slow turn-on current has been developed. A specialized high-frequency pulse with a duty cycle of 50% or less is used which will reduce skin irritation due to polarization effects. To avoid patient discomfort, current delivery is increased gradually over a two-minute period to allow the skin to adapt to the applied current level. The rate of drug delivery is regulated by controlling the energy of the delivered pulse. For antihypertensive-drug administration, the device measures the arterial pressure and continually readjusts delivery rates to keep it close to a desired target value.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130084344","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D.E. Franscischelli, J. Tarbell, S. Deutsch, D. Geselowitz
{"title":"A fiber-optic technique to determine blood residence times and washout patterns in the Penn State artificial heart","authors":"D.E. Franscischelli, J. Tarbell, S. Deutsch, D. Geselowitz","doi":"10.1109/NEBC.1989.36708","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36708","url":null,"abstract":"Low shear regions tend to be sites of stasis or stagnation of blood cells. To quantify and evaluate the degree of stagnation, a flush-mountable fiber-optic probe was developed, and dye dilution techniques utilizing the fluorescent dye fluorescein were applied. This method allowed the washout patterns to be determined at several locations within the chamber, extending approximately 2 mm from the chamber wall. Both the 100-cm/sup 3/ angle port and 70-cm/sup 3/ parallel port chamber configurations were investigated under 30% and 50% systolic duration regimes.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"71 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130157900","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Imaging multi-spectral fluorescent probes in living cells at video rates","authors":"F.J. Delaville, K. Fogarty, F. Fay","doi":"10.1109/NEBC.1989.36791","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36791","url":null,"abstract":"A fast digital imaging fluorescence microscope capable of obtaining multispectral images at video rates (30/s) has been developed. It integrates commercially available equipment with custom-made circuitry and software to record freeze-frame images of 100-ms duration every 1/30 s. The components involved and the sources of noise have been fully characterized to use their models in offline processing. From the raw images, spatial changes in concentration or distribution can be studied as a function of time. The system will be tested with calcium images obtained by loading single isolated smooth muscle cells with Fura-2 fluorescent dye. The system is capable of generating a movie in which the calcium distribution can be seen changing with time.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130477655","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Convolution algorithm for estimation of scatter and glare in diagnostic radiology","authors":"S. Naimuddin","doi":"10.1109/NEBC.1989.36726","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36726","url":null,"abstract":"Digital radiographic images acquired using an image-intensifier-TV system suffer from contrast degradation because of scattered radiation from the patient and veiling glare in the detector system. These perturbations must be corrected before accurate quantitative information can be derived from the images. The authors theoretically derived an approximation for the X-ray scatter and veiling glare in a digital image. They developed a method to estimate it by convolving the detected image and multiplying it by spatially varying weighting factors. This technique was implemented on a humanoid chest phantom and provided a close estimate of scatter/glare in all portions of the image.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"60 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125439327","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
D. Khoury, J. Maloney, H. Mcalister, T. Simmons, B. Wilkoff, Y. Rudy
{"title":"The impedance catheter: potential for differentiation between hemodynamically stable and unstable arrhythmias","authors":"D. Khoury, J. Maloney, H. Mcalister, T. Simmons, B. Wilkoff, Y. Rudy","doi":"10.1109/NEBC.1989.36668","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36668","url":null,"abstract":"An assessment is made of the efficacy of the impedance catheter in sensing relative volumetric changes in the right ventricle as a means of monitoring the hemodynamic status during an arrhythmia. During electrophysiologic testing, 37 arrhythmias were induced in 12 patients. Stroke impedance (peak value minus minimum value) was significantly lower in hemodynamically unstable ventricular arrhythmias (ventricular tachycardia and ventricular fibrillation) than in stable tachyarrhythmias (supraventricular tachycardia and stable monomorphic ventricular tachycardia). Implementation of hemodynamic sensing can improve arrhythmia specificity of the sensing algorithm of future implantable defibrillators and may add options for selective pace termination or cardioversion.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122293833","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Biological time-series analysis via a fast orthogonal search","authors":"M. Korenberg","doi":"10.1109/NEBC.1989.36744","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36744","url":null,"abstract":"Advantages of time-series analysis are described and illustrated by the fast orthogonal search method. The method can be used to approximate biological time-series data by a parsimonious sinusoidal series model or representation. The component frequencies in this model need not be commensurate nor integral multiples of the fundamental frequency corresponding to the record length. The method achieves economy of representation by finding the most significant frequencies first. In simulations, the author shows that the method really copes with missing or unequally-spaced data, and is capable of five to eight time the frequency resolution of a conventional Fourier-series analysis.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127792245","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Anisotropy of human coronary artery intima","authors":"P. Richardson, S. Keeny","doi":"10.1109/NEBC.1989.36772","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36772","url":null,"abstract":"There is extensive evidence that the acute phase of myocardial infarction frequency involves fissuring of the intima of epicardial coronary arteries. The fissures have been found postmortem generally at the sites of atheromatous plaques containing lipid. Pathological evidence suggest that the fracture occurs before death, with a thrombus growing in the pocket of the plaque as well as in the lumen of the vessel. Mechanical measurements have been made in uniaxial testing of human coronary artery intima segments. The fracture stresses measured are in the range of those computed in whole vessel walls, for which measured mechanical properties of tissues have been assigned, under pressure achieved within the physiological range, after the stress-intensifying effects of local lipid plaques have been incorporated.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"72 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131820248","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Breathing modulates fetal heart rate","authors":"Y. Noguchi, G. Dwyer, H. Szeto","doi":"10.1109/NEBC.1989.36786","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36786","url":null,"abstract":"To assess the modulation of fetal heart rate (FHR) by breathing movements, the authors investigated the relationship between FHR and fetal breathing rate (FBR). FHR was obtained from the R-R interval of the EKG and FBR from the burst-burst interval of the diaphragmatic electromyogram (EMG). The R-R intervals of EKG and burst-burst interval of the diaphragmatic EMG were determined using a template recognition method. These data were then analyzed in both the frequency and time domains. Frequency analysis was carried out using the linear prediction method with the optimum order. It is confirmed that fetal breathing movements modulate fetal heart-rate variability.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122972614","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Using optimally focused electromagnetic power for hyperthermia treatment of deep tumors in biological tissue","authors":"C. Rappaport","doi":"10.1109/NEBC.1989.36751","DOIUrl":"https://doi.org/10.1109/NEBC.1989.36751","url":null,"abstract":"Favorable responses to heating tumors to 42-45 degrees C has lead to development of electromagnetic antenna applicators which noninvasively couple power to cancerous tumors. This modality avoids surgery trauma, healthy tissue destruction from ionizing radiation, and toxic effects of chemotherapy. By adjusting the antenna radiation characteristics, it is possible to focus power on abnormal tissue while sparing healthy tissue. The current analysis uses simple geometric models of tissue: (planar slab, circular cylinder, and sphere) to determine the best antenna electric field distributors for heating deep, localized tumor volumes. The best distributions deliver as much power as possible to the tumor. It is shown that the best standard frequency for focusing electromagnetic power is 915 MHz, and that the optimal distribution is better than the expected conjugate phase distribution.<<ETX>>","PeriodicalId":156554,"journal":{"name":"Proceedings of the Fifteenth Annual Northeast Bioengineering Conference","volume":"222 4","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1989-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134323007","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}