Power system angular stability as affected by the reduced inertia due to wind displacing synchronous generators 风力置换同步发电机后惯性减小对电力系统角稳定性的影响
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390567
Xiao Chen, W. Du, H. Wang
{"title":"Power system angular stability as affected by the reduced inertia due to wind displacing synchronous generators","authors":"Xiao Chen, W. Du, H. Wang","doi":"10.1109/ICPRE.2017.8390567","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390567","url":null,"abstract":"This paper investigates the power system angular stability as affected by the reduced inertia due to wind displacing synchronous generators. The investigation focuses on the change of the effect when the locations of displaced synchronous generators vary. Theoretical analysis is carried out on the basis of the continuum model of a power system, which is demonstrated and validated by simulation and computation of an example two-area multi-machine power system. It is shown in the paper that the effect of displacement on power system transient stability is beneficial if the displacement makes the system more “symmetrical” and vice versa, which is related with the steady-state load flow conditions and distribution of inertia of synchronous generators in the power system.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129222658","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Experimental study on the tolerance ability of adjustable speed drives to voltage sags 调速传动对电压跌落的容限能力实验研究
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390551
Chenyi Li, Shuming Liu, Yingying Liu, Qionglin Li, Yonghai Xu
{"title":"Experimental study on the tolerance ability of adjustable speed drives to voltage sags","authors":"Chenyi Li, Shuming Liu, Yingying Liu, Qionglin Li, Yonghai Xu","doi":"10.1109/ICPRE.2017.8390551","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390551","url":null,"abstract":"The process of energy transmitting is vulnerable to power quality problems. The adjustable speed drive (ASD) is one sensitive part of the process to voltage sags which will cause the interruption of the whole process if it trips due to sags. It is essential to analyze the voltage tolerance ability of ASDs and formulate a representative standard voltage tolerance curve (VTC) for it. Firstly, this paper analyzed basic influence principle of sags on ASDs and the influence of multiple factors on the voltage tolerance ability of ASDs, including sags types, load torque, motor speed, control strategy, pre-post sag voltage and harmonics. Then a test platform was established using the Chroma 61860 Regenerative Grid Simulator as the source of sag. 7 typical brands of ASDs with 2 kinds of rated power were selected to be tested. Later, sets of VTCs were obtained and further analyzed separately. The majority of the conclusions shows consistency to the theoretical analysis, but there are also some distinctions to the present conclusions. Finally, relatively universal VTCs for three of sags were proposed, which are of reference meaning to regulate the special standard curve for ASDs.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"224 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114691792","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
The simulation analyses of Jinnan ± 800kV UHVDC transmission control system based on PSCAD/EMTDC 基于PSCAD/EMTDC的晋南±800kV特高压直流输电控制系统仿真分析
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390553
Huidong Guo, Mengqiong Wang, Yuxin Shi, Zhenguo Ma
{"title":"The simulation analyses of Jinnan ± 800kV UHVDC transmission control system based on PSCAD/EMTDC","authors":"Huidong Guo, Mengqiong Wang, Yuxin Shi, Zhenguo Ma","doi":"10.1109/ICPRE.2017.8390553","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390553","url":null,"abstract":"Taking Jinnan ± 800kV ultra-high voltage direct current power transmission system as study object, this paper discusses simulation model of UHVDC by PSCAD /EMTDC (Power system computer aided design and electric magnetic transient in DC system). Compared with the waveform in actual engineering system debugging, the results of a series of simulation analyses show that the ± 800kV UHVDC system constructed is reliable. The simulation platform can deeply study the control system of UHVDC, which has the practical significance of engineering.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"283 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124518767","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Monitoring of optical power in fiber communication for secondary equipment in smart substation 智能变电站二次设备光纤通信光功率监测
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390610
Jiaxu Guo, Qi Huang, Sinian Xiong, Shi Jing, W. Zhen, Jie Ren
{"title":"Monitoring of optical power in fiber communication for secondary equipment in smart substation","authors":"Jiaxu Guo, Qi Huang, Sinian Xiong, Shi Jing, W. Zhen, Jie Ren","doi":"10.1109/ICPRE.2017.8390610","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390610","url":null,"abstract":"Information communication system is one of the keys to the implementation of a smart substation, therefore monitoring of optical power for the secondary equipment network is helpful to improve the security and stability of communication in substation. Based on a study of the existing monitoring methods of optical fiber communication in smart substation, a monitoring system of optical power is proposed by analyzing the historical data and historical trend. Some key parts such as the framework for the monitoring system of optical power, template library of component, historical database and the analysis of historical trend are implemented. In this monitoring system, prediction of changes in optical power based on historical trend is designed and analyzed. Finally, the feasibility of the monitoring method of optical power in fiber communication for secondary equipment and using it as a prejudgment to retrieve abnormal communication state are verified by a practical example.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124067408","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Analysis of subsynchronous oscillation characteristics and its dominant factors in the DFIG-based wind farm with fixed series compensation 固定串联补偿的dfig型风电场次同步振荡特性及其主导因素分析
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390511
Guoliang Zhao, Hongyang Yu, Kun Zhang, Zongye Liu, Xiaohan Zhang, Lin Yang
{"title":"Analysis of subsynchronous oscillation characteristics and its dominant factors in the DFIG-based wind farm with fixed series compensation","authors":"Guoliang Zhao, Hongyang Yu, Kun Zhang, Zongye Liu, Xiaohan Zhang, Lin Yang","doi":"10.1109/ICPRE.2017.8390511","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390511","url":null,"abstract":"Aiming at subsynchronous oscillation (SSO) in doubly fed induction generator (DFIG) based wind farm with fixed series compensation (FSC), this paper analyze its characteristics based on eigenvalue analysis. Analysis results indicate that this kind of SSO is the electrical interaction related to the generator, converter and FSC, and its basic characteristics are similar with induction generator effect (IGE). The root causes include negative resistors effect related to the rotor resistor and current inner loop of rotor side converter (RSC) in subsynchronous frequency range, and subsynchronous modulation effect of the converters.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125778537","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Maximum power point performance tracking comparison between incremental conductance with perturb and observe algorithms in photovoltaic power systems 光伏发电系统电导增量摄动与观测算法最大功率点性能跟踪比较
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390668
Samuel Bimenyimana, Godwin Norense Osarumwense Asemota, Ling-ling Li
{"title":"Maximum power point performance tracking comparison between incremental conductance with perturb and observe algorithms in photovoltaic power systems","authors":"Samuel Bimenyimana, Godwin Norense Osarumwense Asemota, Ling-ling Li","doi":"10.1109/ICPRE.2017.8390668","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390668","url":null,"abstract":"Electric power from solar energy technologies is gaining great and important uses because of cleanness, free, no noise and little maintenance. Their characteristic output power depends on fluctuating climatic conditions like temperature, cloud cover, and irradiance. Since climate is not always uniform, maximum power point tracking techniques are used in solar power systems to extract maximum power from photovoltaic systems. In this paper, voltage and current data from a 50 W stand-alone photovoltaic module located in Rwamagana district, Rwanda were recorded and used to compare the performance between incremental conductance algorithm with perturb and observe algorithm for maximum power point tracking. The maximum power point of 12.044 W was achieved at 15 hours for the incremental conductance algorithm. Both I-V and P-V characteristics of PV system show n-shaped nonlinear conductance and n-shaped nonlinear current characteristic curves. An equation was developed for the dissipative saw-tooth wave irradiance characteristic curve, at fairly constant temperatures, in the study.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"179 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133888041","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Multi-source optimal schedule of power system considering smoothing effect of wind and photovoltaic sources 考虑风力和光伏源平滑效应的电力系统多源优化调度
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390606
Dandan Sun, S. Miao, Lixing Li, Chang Ye, Kaiyun Chao
{"title":"Multi-source optimal schedule of power system considering smoothing effect of wind and photovoltaic sources","authors":"Dandan Sun, S. Miao, Lixing Li, Chang Ye, Kaiyun Chao","doi":"10.1109/ICPRE.2017.8390606","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390606","url":null,"abstract":"The integration of extensive wind and solar power into power system brings great threat to the safe and stable operation of the grid, as well as decreasing the economy of unit commitment. In this paper, a multi-source optimal schedule of power system considering smoothing effect of wind and photovoltaic sources is proposed to alleviate the adverse effect of wind and solar power and to realize the economic operation. The cluster composed of six wind power plants and three photovoltaic plants in Portland of America is adopted as the study objective. Firstly, index for assessing smoothing effect is proposed and the influence factors of smoothing effect are analyzed. Secondly, six typical weather patterns are identified based on the power output fluctuation of the wind and solar. Thirdly, a multi-source complementary double layer optimal scheduling model is established which takes different weather types into consideration. Finally, case study shows that the model can efficiently increase the economy of unit commitment and stabilize the power system.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"146 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134361823","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
ZIP and equivalent thermostatic loads impacts on energy savings of conservation voltage reduction ZIP和等效恒温负荷对节能降压的影响
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390537
Jun Wang, Qi Hunag, Ashhar Raza, Tianqi Hong, Zhenyuan Zhang, Hongyan Li
{"title":"ZIP and equivalent thermostatic loads impacts on energy savings of conservation voltage reduction","authors":"Jun Wang, Qi Hunag, Ashhar Raza, Tianqi Hong, Zhenyuan Zhang, Hongyan Li","doi":"10.1109/ICPRE.2017.8390537","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390537","url":null,"abstract":"Conservation voltage reduction (CVR) plays an important role in energy savings. Loads can be modeled as static ZIP coefficients or as equivalent thermostatic loads (ETLs) for CVR peak demand and energy savings calculations. In this paper, simulations of a benchmark 69-bus distribution system show that ETLs can better capture end-use loads power and energy changes as ambient temperature varies. The analysis of results demonstrates that customer loads modeled as ETLs are more accurate than loads modeled as ZIP coefficients in the calculation of energy savings and peak demand of CVR.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131470608","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Coupling characteristics and mechanism of the dynamic behaviors of high and low voltage power grid 高低压电网动态行为的耦合特性及机理
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390685
Zhenhuan Yuan, Hengxu Zhang, Fang Shi, Changhui Ma, Gang Liu
{"title":"Coupling characteristics and mechanism of the dynamic behaviors of high and low voltage power grid","authors":"Zhenhuan Yuan, Hengxu Zhang, Fang Shi, Changhui Ma, Gang Liu","doi":"10.1109/ICPRE.2017.8390685","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390685","url":null,"abstract":"The increasing complexity of the dynamic behavior of low-voltage (LV) power grid makes it necessary for synchronous phasor measurement in LV grids. After a large disturbance, the dynamic behavior detected at the LV level is the coupling between dynamic behaviors of high-voltage (HV) major grid and LV local grid, which needs to be decoupled for different applications. This paper analyzes the response characteristics of LV power grid to a variety of common disturbances and proposes a mathematical model for the synchronized measurement data of high and low voltage grids. The coupling phenomenon of dynamic behaviors is explained for different load models. Finally, the theoretical analysis is verified by simulation.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115637498","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Research and simulation of centralized charge and discharge technology of EVs based on MMC 基于MMC的电动汽车集中充放电技术研究与仿真
2017 2nd International Conference on Power and Renewable Energy (ICPRE) Pub Date : 2017-09-01 DOI: 10.1109/ICPRE.2017.8390644
Zhuowu Yan, Z. Yin, Xiaotian Yang, Kai Zhang, Jing Shi, Liqiang Wang
{"title":"Research and simulation of centralized charge and discharge technology of EVs based on MMC","authors":"Zhuowu Yan, Z. Yin, Xiaotian Yang, Kai Zhang, Jing Shi, Liqiang Wang","doi":"10.1109/ICPRE.2017.8390644","DOIUrl":"https://doi.org/10.1109/ICPRE.2017.8390644","url":null,"abstract":"In order to meet the requirements of large-scale EVs (electric vehicles) centralized charge and discharge in a specific situation and solve the resulting serious problem such as three-phase unbalance, high grid-connected harmonic contents and so on, this paper proposes a large-scale centralized charge and discharge system of EVs based on modular multilevel converter (MMC). The topology is based on the traditional MMC, and connects to EVs by bidirectional Buck/Boost circuit in each submodules, which makes bidirectional flow of power between grid and power battery of EVs in submodules. The control strategy of converter level, voltage balance strategy that corresponding to carrier phase shift modulation and Buck/Boost control strategy in submodules are researched, and the power quality problems caused by large-scale charge and discharge is avoided. The simulation based on Matlab/Simulink verifies feasibility of the system structure and the effectiveness of the control strategy.","PeriodicalId":123761,"journal":{"name":"2017 2nd International Conference on Power and Renewable Energy (ICPRE)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122061224","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书