2021 International Ural Conference on Electrical Power Engineering (UralCon)最新文献

筛选
英文 中文
Hill-Climbing Algorithm for the Wind Turbine Yaw System 风力机偏航系统爬坡算法
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559498
Yusong Yang, E. Solomin
{"title":"Hill-Climbing Algorithm for the Wind Turbine Yaw System","authors":"Yusong Yang, E. Solomin","doi":"10.1109/UralCon52005.2021.9559498","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559498","url":null,"abstract":"Regarding the wind energy conversion system (WECS), wind speed and direction affect its output power. The yaw system is applied for decreasing the influence of wind direction changes on the turbine output power and directly determines the economic benefits of the wind energy conversion system. This paper introduces the working principle of the hill-climbing algorithm for the wind turbine yaw system. The modeling principle of the hill-climbing algorithm S-function is more complicated, error-prone, and difficult to troubleshoot. So this paper uses the Matlab/Simulink basic module to establish a wind turbine hill-climbing algorithm model for the yaw system. The simulation shows that the hill-climbing yaw system model can correctly track the wind direction change, eliminate the yaw error, and then enable the wind turbine to orient to the wind direction and maintain the maximum output power.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130096705","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Determination of the Reliability of Power Supply Systems in High-Altitude Areas from Hybrid Power Sources Using a Logical-Probabilistic Method Based on a Dynamic Failure Tree 基于动态故障树的高海拔地区混合电源供电系统可靠性的逻辑-概率方法研究
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559504
G. Titova, M. Malsagov, A. R. Elbazurov
{"title":"Determination of the Reliability of Power Supply Systems in High-Altitude Areas from Hybrid Power Sources Using a Logical-Probabilistic Method Based on a Dynamic Failure Tree","authors":"G. Titova, M. Malsagov, A. R. Elbazurov","doi":"10.1109/UralCon52005.2021.9559504","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559504","url":null,"abstract":"This paper investigates issues related to the reliability of power supply from autonomous hybrid stations based on renewable sources of wind and solar energy. The considered power supply schemes are from hybrid stations with two wind turbines of 250 kW and ten of 50 kW capacity. Calculations of the annual electricity production are carried out considering the change in wind speed. Failure rate is presented as an exponential distribution for ease of calculation. The reliability of hybrid installations is distributed according to the coefficients: forced downtime, availability and technical use. The transitions of a power supply system from one state to another are described using state graphs. A differential equation of the state matrix is produced. Different types of the proposed schemes are compared on the basis of technical and economic comparison as well as the probabilistic method based on a dynamic fault tree, taking into account the natural factors of wind turbines operation. The sufficiency is proved using probabilistic method based on a dynamic fault tree with an error of 0.04%.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133274890","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Study on the "Dead Zone" of the Operation of the Automatic Device for Elimination of the Asynchronous Operation of Overhead Power Transmission Lines 架空输电线路异步运行自动消除装置运行“死区”研究
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559567
V. A. Kizin, A. Y. Smirnova, S. Shovkoplyas
{"title":"Study on the \"Dead Zone\" of the Operation of the Automatic Device for Elimination of the Asynchronous Operation of Overhead Power Transmission Lines","authors":"V. A. Kizin, A. Y. Smirnova, S. Shovkoplyas","doi":"10.1109/UralCon52005.2021.9559567","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559567","url":null,"abstract":"The general information on the existing automatic devices for the elimination of the asynchronous operation (AEAO) and their application on overhead power transmission lines (OHL) is given, as well as deficiencies in their operation in terms of blocking by the minimum voltage are noted. The presence of \"dead zones\" of the AEAO device actuation according to the \"angular\" principle, that are detected during tests on the given settings, is shown. An experience exchange gained during the commissioning of AEAO devices on 110 kV overhead power transmission lines in the electrical network of the distribution grid complex of the branch of PJSC Rosseti Kuban was carried out. The methodology for calculation of the \"dead zones\" of the AEAO device actuation and taking them into account in the design, as well as in the formation of the task for the settings of the AEAO device is recommended.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130405932","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analyzing the Transmission Capacity of Distribution Grids Powering Oil and Gas Production Facilities 油气生产设施配电网输电能力分析
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559457
A. Kuvshinov, V. Vakhnina, A. Chernenko
{"title":"Analyzing the Transmission Capacity of Distribution Grids Powering Oil and Gas Production Facilities","authors":"A. Kuvshinov, V. Vakhnina, A. Chernenko","doi":"10.1109/UralCon52005.2021.9559457","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559457","url":null,"abstract":"The impact of reactive power loss on the operating parameters of distribution grids powering oil and gas production facilities has been analyzed. It is shown that the active and reactive power losses in distribution grids significantly depend on the reactive power compensation at the consumption node; they reach minimum values at full compensation and significantly increase at incomplete or overcompensation, and the higher the Q-factor of the distribution grid and the reactive power factor of the load the greater the loss. It is shown that with full compensation of the reactive power of the load, the voltage loss can be further reduced by reducing the reactive power loss in the distribution line. The possibility of increasing the distribution line capacity by 1.33-1.67 by creating a natural power transmission mode to compensate for reactive power loss has been justified.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130593013","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Improving Power Quality in Power Supply Systems for Rolling Mills FC-AR due to the Use of Specialised Passive Filters 由于使用专用无源滤波器,改善轧机FC-AR供电系统的电能质量
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559417
A. Nikolaev, M. Afanasev, M. V. Bulanov
{"title":"Improving Power Quality in Power Supply Systems for Rolling Mills FC-AR due to the Use of Specialised Passive Filters","authors":"A. Nikolaev, M. Afanasev, M. V. Bulanov","doi":"10.1109/UralCon52005.2021.9559417","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559417","url":null,"abstract":"This article deals with the way to improve the power quality in in-plant networks of industrial plants with powerful frequency converters with active rectifiers (FC with AF) through the use of specialised passive filters. In recent years, the FC with AFs have become very widespread due to their advantages, such as: 1) possibility of energy recovery in braking modes of electric drive; 2) support of the set value of power factor at the input of AR. At the same time, they have a significant disadvantage, which is the deterioration of voltage quality in the 6-35 kV power distribution network due to the imposition of high-frequency harmonics of input voltage and current of AR on the resonant area of the supply network frequency response. This disadvantage can be eliminated by using special passive filters in the in-plant power networks, which ensure that the main resonance of currents is shifted to a zone free from high-frequency harmonics of the FC with AR. This makes it possible to reduce the harmonic distortion coefficient in the voltage sections of the enterprise MSS. The article presents the results of research on the application effectiveness of specialized passive filters in the system of in-plant power supply of the rolling complex, functioning at CherMK of PJSC \"Severstal\".","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129567104","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Software Package for Technological System Elements Testing 技术系统元件测试软件包
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559465
G. Kilin, A. Suslov, B. Kavalerov
{"title":"Software Package for Technological System Elements Testing","authors":"G. Kilin, A. Suslov, B. Kavalerov","doi":"10.1109/UralCon52005.2021.9559465","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559465","url":null,"abstract":"The procedure for testing complex technological objects both individually and as part of a technological system is a very resource-intensive task. Full-scale tests require qualified personnel presence and a properly functioning technological facility. To simplify such tests procedure, technological objects mathematical models are used, which allow modeling the main characteristic modes with the necessary accuracy, which is necessarily determined by the problem solved during the tests. Many tests include taking into account the influence of other technological system elements on the tested technological object and vice versa. To account for such an influence, it is necessary to have mathematical models that affect the technological object under test, elements for taking into account the entire list of operation and interaction modes. In this article, the necessity of using a technological system complex mathematical model, as part of a software package, for testing its constituent elements is considered. Complex universal mathematical model of an electric power system element structure is revealed, which allows assembling electric power system circuits of arbitrary complexity and configuration.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"103 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130040241","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Development of Method of Protection of Solar Panels Against Dust Pollution in the Northern Part of the Russian Far East 俄罗斯远东北部地区太阳能电池板防粉尘污染保护方法的发展
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559596
Nikolay Mestnikov, P. Vasiliev, A. Alzakkar
{"title":"Development of Method of Protection of Solar Panels Against Dust Pollution in the Northern Part of the Russian Far East","authors":"Nikolay Mestnikov, P. Vasiliev, A. Alzakkar","doi":"10.1109/UralCon52005.2021.9559596","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559596","url":null,"abstract":"The paper is devoted to research about the method of protection against dust pollution of the surface of a polycrystalline solar panel of small power in the northern part of the Russian far east (the territory of the North), where the article presents graphical interpretations of power generation depending on dust content parameters and calculation of changes in electric power generation parameters. The purpose of this paper is to find an effective method for protecting the surface of a polycrystalline solar panel of small power from dust pollution. The result of this article is the calculation and derivation of solar panel generation indicators with the presentation of graphical interpretations of power dependence on monitoring time. In addition, based on the calculated comparison of solar panel generation using various chemical liquid coatings, the article presents a specific type of chemical material that protects the surface of the solar panel from dust pollution and reduces the effect of adhesion properties on the period up to 15 days. Thus, the above-mentioned method of protecting the surface of the solar panel from dust pollution can be applied in research institutes and generating enterprises in order to increase energy efficiency and generate electricity in solar power plants in the northern part of the Russian Far East.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125199878","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Neural Network for Real-Time Signal Processing: the Nonlinear Distortions Filtering 用于实时信号处理的神经网络:非线性失真滤波
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559619
A. L. Slavutskiy, L. Slavutskii, Elena Vladimirovna Slavutskaya
{"title":"Neural Network for Real-Time Signal Processing: the Nonlinear Distortions Filtering","authors":"A. L. Slavutskiy, L. Slavutskii, Elena Vladimirovna Slavutskaya","doi":"10.1109/UralCon52005.2021.9559619","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559619","url":null,"abstract":"Artificial neural networks, after their training and testing, allow, in the \"if then\" mode, to process signals in real time. This is relevant for signal processing tasks in electrical engineering and the electric power industry, especially for the analysis of nonlinear signal distortions, transients in electrical networks, during switching, emergency modes, and so on. The paper shows the neuro algorithm possibilities based on an elementary perceptron for filtering nonlinear distortions of industrial frequency signals of 50 Hz over a time interval of units of milliseconds. At the same time, the accuracy for the signals’ amplitude, phase, and frequency determining is units of percent. Examples of the fundamental frequency signal selection in the presence of harmonics, the determination of the signal parameters during transients, and the correction of the transformer saturation current are given. It is shown that real-time neural network processing can be carried out in a \"sliding window\" with the duration of units of milliseconds. The estimates made during the implementation of the neuro algorithm in a microprocessor device showed its application possibility in the electric power industry secondary equipment.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124620687","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Self-Contained Power Station Based on Asynchronous Electrical Generator with Short Circuit Rotor Winding and Low Power Frequency Converter 基于短路转子绕组异步发电机和低功率变频器的自备电站
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559520
A. Vinogradov, K. Ermakov, A. Korotkov
{"title":"Self-Contained Power Station Based on Asynchronous Electrical Generator with Short Circuit Rotor Winding and Low Power Frequency Converter","authors":"A. Vinogradov, K. Ermakov, A. Korotkov","doi":"10.1109/UralCon52005.2021.9559520","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559520","url":null,"abstract":"The paper considers the construction of a self-contained power station (SCPS), based on an asynchronous generator with a short-circuited rotor and a low-power voltage inverter that provides high-quality output voltage under various loads, including significantly non-symmetrical and nonlinear ones, at a relatively low price and increased reliability. The block-diagrams of the SCPS and its control system without a speed sensor on the generator shaft are presented, as well as the results of modeling in symmetric and asymmetric operating modes, including the mode of blocking power switches of the voltage inverter. SCPS provides an error of output voltage stabilization of no more than 0.5% at maximum load asymmetry, correction of output voltage asymmetry using an original search compensation algorithm, reliable protection against overloads, short circuits and overvoltage using power switches blocking mode of the inverter. In blocking the inverter state SCPS smoothly moves to the mode of an unstable voltage source when the load is within the nominal and to the mode of maintaining the output current at an acceptable level during short circuits and overloads.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117331578","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Non-Contact Methods for High-Voltage Insulator Diagnosis 高压绝缘子非接触诊断方法
2021 International Ural Conference on Electrical Power Engineering (UralCon) Pub Date : 2021-09-24 DOI: 10.1109/UralCon52005.2021.9559473
D. Ivanov, A. Golenishchev-Kutuzov, T. Galieva
{"title":"Non-Contact Methods for High-Voltage Insulator Diagnosis","authors":"D. Ivanov, A. Golenishchev-Kutuzov, T. Galieva","doi":"10.1109/UralCon52005.2021.9559473","DOIUrl":"https://doi.org/10.1109/UralCon52005.2021.9559473","url":null,"abstract":"The article is devoted to the developed non-contact methods of NDT for dielectric elements of electrical equipment during operation under operating voltage. The experience of a team of authors in the development of devices and methods for the diagnosis of partial discharges in high-voltage insulators is presented. Based on the developed devices and programs for processing diagnostic information, a system for monitoring the technical state of high-voltage insulation under operating voltage was created.","PeriodicalId":123717,"journal":{"name":"2021 International Ural Conference on Electrical Power Engineering (UralCon)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2021-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123223398","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书