Expert Review of Medical Devices最新文献

筛选
英文 中文
Complications after peripherally inserted central catheter versus central venous catheter implantation in intensive care unit: propensity score analysis using a nationwide database. 重症监护室植入外周置入中心导管与中心静脉导管后的并发症:利用全国性数据库进行倾向评分分析。
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-25 DOI: 10.1080/17434440.2024.2346191
Toshiaki Takahashi, K. Morita, K. Uda, H. Matsui, Hideo Yasunaga, G. Nakagami
{"title":"Complications after peripherally inserted central catheter versus central venous catheter implantation in intensive care unit: propensity score analysis using a nationwide database.","authors":"Toshiaki Takahashi, K. Morita, K. Uda, H. Matsui, Hideo Yasunaga, G. Nakagami","doi":"10.1080/17434440.2024.2346191","DOIUrl":"https://doi.org/10.1080/17434440.2024.2346191","url":null,"abstract":"BACKGROUND\u0000It remains unclear whether peripherally inserted central catheters (PICCs) are superior to central venous catheters (CVCs); therefore, we compared post-implantation complications between CVC and PICC groups.\u0000\u0000\u0000RESEARCH DESIGN AND METHODS\u0000Patients who received CVCs or PICCs between April 2010 and March 2018 were identified from the Diagnosis Procedure Combination database, a national inpatient database in Japan. The outcomes of interest included catheter infection, pulmonary embolism, deep vein thrombosis, and phlebitis. Propensity score overlap weighting was used to balance patient backgrounds. Outcomes were compared using logistic regression analyses.\u0000\u0000\u0000RESULTS\u0000We identified 164,185 eligible patients, including 161,605 (98.4%) and 2,580 (1.6%) in the CVC and PICC groups, respectively. The PICC group was more likely to have overall complications (odds ratio [OR], 1.70; 95% confidence interval [CI], 1.32-2.19), pulmonary embolism (OR, 2.32; 95% CI, 1.38-3.89), deep vein thrombosis (OR, 1.86; 95% CI, 1.16-2.99), and phlebitis (OR, 1.72; 95% CI, 1.27-2.32) than the CVC group. There was no significant intergroup difference in catheter infection (OR, 1.09; 95% CI, 0.39-3.04).\u0000\u0000\u0000CONCLUSIONS\u0000Patients with PICCs had a significantly greater incidence of complications than did those with CVCs. Further research is necessary to explore the factors contributing to these complications.","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140656810","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Dynamic versus standard bougies for tracheal intubation with direct or indirect laryngoscopy in simulated or real scenarios: a systematic review and meta-analysis. 在模拟或真实场景中使用直接或间接喉镜进行气管插管时的动态和标准布吉:系统综述和荟萃分析。
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-24 DOI: 10.1080/17434440.2024.2344667
J. Sastre, M. Gómez-Ríos, Teresa López, U. Gutiérrez-Couto, Rubén Casans-Francés
{"title":"Dynamic versus standard bougies for tracheal intubation with direct or indirect laryngoscopy in simulated or real scenarios: a systematic review and meta-analysis.","authors":"J. Sastre, M. Gómez-Ríos, Teresa López, U. Gutiérrez-Couto, Rubén Casans-Francés","doi":"10.1080/17434440.2024.2344667","DOIUrl":"https://doi.org/10.1080/17434440.2024.2344667","url":null,"abstract":"INTRODUCTION\u0000This systematic review and meta-analysis aimed to compare the efficacy of dynamic versus standard bougies to achieve tracheal intubation.\u0000\u0000\u0000METHODS\u0000We searched MEDLINE, Embase, CENTRAL, Web of Science, Scopus and Google Scholar on 10 October 2023. We included clinical trials comparing both devices. The primary outcome was the first-attempt intubation success rate. The secondary outcome was the time required for tracheal intubation.\u0000\u0000\u0000RESULTS\u0000Eighteen studies were included. Dynamic bougies do not increase first-attempt success rate (RR 1.11; p = 0.06) or shorten tracheal intubation time (MD -0.30 sec; p = 0.84) in clinical trials in humans. In difficult airways, first-attempt success intubation rate was greater for dynamic bougies (RR 1.17; p = 0.002); Additionally, they reduced the time required for intubation (MD -4.80 sec; p = 0.001). First-attempt intubation success rate was higher (RR 1.15; p = 0.01) and time to achieve intubation was shorter when using Macintosh blades combined with dynamic bougies (MD -5.38 sec; p < 0.00001). Heterogeneity was high.\u0000\u0000\u0000CONCLUSION\u0000Dynamic bougies do not increase the overall first-pass success rate or shorten tracheal intubation time. However, dynamic bougies seem to improve first-attempt tracheal intubation rate in patients with difficult airways and in those intubated with a Macintosh blade. Further research is needed for definitive conclusions.\u0000\u0000\u0000REGISTRATION OF PROSPERO\u0000CRD42023472122.","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140665322","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Thoracic impedance monitoring in heart failure: from theory to practice. 心力衰竭的胸腔阻抗监测:从理论到实践。
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-24 DOI: 10.1080/17434440.2024.2347412
Ahmed Maraey, Paul Chacko, G. Moukarbel
{"title":"Thoracic impedance monitoring in heart failure: from theory to practice.","authors":"Ahmed Maraey, Paul Chacko, G. Moukarbel","doi":"10.1080/17434440.2024.2347412","DOIUrl":"https://doi.org/10.1080/17434440.2024.2347412","url":null,"abstract":"","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140661804","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A profile on the WISE cortical strip for intraoperative neurophysiological monitoring 用于术中神经电生理监测的 WISE 皮质条带简介
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-17 DOI: 10.1080/17434440.2024.2343421
Johannes Sarnthein, Marian C. Neidert
{"title":"A profile on the WISE cortical strip for intraoperative neurophysiological monitoring","authors":"Johannes Sarnthein, Marian C. Neidert","doi":"10.1080/17434440.2024.2343421","DOIUrl":"https://doi.org/10.1080/17434440.2024.2343421","url":null,"abstract":"During intraoperative neurophysiological monitoring in neurosurgery, brain electrodes are placed to record electrocorticography or to inject current for direct cortical stimulation. A low impedance...","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140611258","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Novel insights into thoracic endografts technology for prevention of distal stent-graft induced new entry (dSINE) following endovascular repair of type B aortic dissections: from bench to bedside 胸腔内移植物技术预防 B 型主动脉夹层血管内修复术后远端支架移植物诱发新入口 (dSINE) 的新见解:从工作台到床旁
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-17 DOI: 10.1080/17434440.2024.2343824
Mario D’Oria, Anders Wanhainen, Tilo Kolbel, William Yoon, Kevin Mani
{"title":"Novel insights into thoracic endografts technology for prevention of distal stent-graft induced new entry (dSINE) following endovascular repair of type B aortic dissections: from bench to bedside","authors":"Mario D’Oria, Anders Wanhainen, Tilo Kolbel, William Yoon, Kevin Mani","doi":"10.1080/17434440.2024.2343824","DOIUrl":"https://doi.org/10.1080/17434440.2024.2343824","url":null,"abstract":"Endovascular treatment of type B aortic dissections (TBAD) has currently acquired a primary therapeutic role when anatomically feasible. The main issue with thoracic endovascular aortic repair (TEV...","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140610915","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Comparative evaluation of blind supraglottic airway device insertion versus videolaryngoscope-guided technique in adults undergoing laparoscopic cholecystectomy 对接受腹腔镜胆囊切除术的成人进行声门上气道装置盲插与视频喉镜引导技术的比较评估
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-16 DOI: 10.1080/17434440.2024.2343423
Navdeep Kaur, Suman Saini, Anju Gupta
{"title":"Comparative evaluation of blind supraglottic airway device insertion versus videolaryngoscope-guided technique in adults undergoing laparoscopic cholecystectomy","authors":"Navdeep Kaur, Suman Saini, Anju Gupta","doi":"10.1080/17434440.2024.2343423","DOIUrl":"https://doi.org/10.1080/17434440.2024.2343423","url":null,"abstract":"A videolaryngoscope may decrease the high incidence of aberrant positioning of supraglottic airway devices (SAD) inserted with blind techniques. We aimed to compare Igel insertion characteristics b...","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140563926","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
GI genius endoscopy module: a clinical profile 消化道天才内窥镜检查单元:临床概况
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-15 DOI: 10.1080/17434440.2024.2342508
Alberto Savino, Emanuele Rondonotti, Simone Rocchetto, Alessandra Piagnani, Niccolò Bina, Pasquale Di Domenico, Francesco Segatta, Franco Radaelli
{"title":"GI genius endoscopy module: a clinical profile","authors":"Alberto Savino, Emanuele Rondonotti, Simone Rocchetto, Alessandra Piagnani, Niccolò Bina, Pasquale Di Domenico, Francesco Segatta, Franco Radaelli","doi":"10.1080/17434440.2024.2342508","DOIUrl":"https://doi.org/10.1080/17434440.2024.2342508","url":null,"abstract":"The identification of early-stage colorectal cancers (CRC) and the resection of pre-cancerous neoplastic lesions through colonoscopy allows to decrease both CRC incidence and mortality. However, co...","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140564086","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Is open anterior advantageous to posterior decompression and reconstruction in fresh A3 to C3/AO type thoracolumbar junction fractures? A systematic review 对于新鲜的A3至C3/AO型胸腰椎交界处骨折,开放式前路减压和重建是否优于后路减压和重建?系统回顾
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-09 DOI: 10.1080/17434440.2024.2341109
P Korovessis, Vasileios Syrimpeis, Alkis Korovesis
{"title":"Is open anterior advantageous to posterior decompression and reconstruction in fresh A3 to C3/AO type thoracolumbar junction fractures? A systematic review","authors":"P Korovessis, Vasileios Syrimpeis, Alkis Korovesis","doi":"10.1080/17434440.2024.2341109","DOIUrl":"https://doi.org/10.1080/17434440.2024.2341109","url":null,"abstract":"Surgical outcomes of open anterior and open posterior approaches, for thoracolumbar A3 to C3/AO type fractures, are compared.A PubMed search was conducted from 1990 to 2024 related to anterior, pos...","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140564085","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Devices-based treatment of hypertension: the position of the European Society of Hypertension (ESH) 2023 guidelines 基于设备的高血压治疗:欧洲高血压学会(ESH)2023 指南的立场
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-08 DOI: 10.1080/17434440.2024.2339414
Guido Grassi
{"title":"Devices-based treatment of hypertension: the position of the European Society of Hypertension (ESH) 2023 guidelines","authors":"Guido Grassi","doi":"10.1080/17434440.2024.2339414","DOIUrl":"https://doi.org/10.1080/17434440.2024.2339414","url":null,"abstract":"Published in Expert Review of Medical Devices (Ahead of Print, 2024)","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140564081","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Deep brain stimulation for Alzheimer’s disease – current status and next steps 深部脑刺激治疗阿尔茨海默病--现状和下一步措施
IF 3.1 3区 医学
Expert Review of Medical Devices Pub Date : 2024-04-04 DOI: 10.1080/17434440.2024.2337298
Benjamin Davidson, Artur Vetkas, Jürgen Germann, David Tang-Wai, Andres M. Lozano
{"title":"Deep brain stimulation for Alzheimer’s disease – current status and next steps","authors":"Benjamin Davidson, Artur Vetkas, Jürgen Germann, David Tang-Wai, Andres M. Lozano","doi":"10.1080/17434440.2024.2337298","DOIUrl":"https://doi.org/10.1080/17434440.2024.2337298","url":null,"abstract":"Alzheimer’s disease (AD) requires novel therapeutic approaches due to limited efficacy of current treatments.This article explores AD as a manifestation of neurocircuit dysfunction and evaluates de...","PeriodicalId":12330,"journal":{"name":"Expert Review of Medical Devices","volume":null,"pages":null},"PeriodicalIF":3.1,"publicationDate":"2024-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140563978","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信