{"title":"Design of a Microprocessor-Based Digital Wattmeter","authors":"John J. Hill, W. Alderson","doi":"10.1109/TIECI.1981.351073","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351073","url":null,"abstract":"A microprocessor-based implementation of the sampling wattmeter is described. The measurement process is in two parts. First, the microprocessor measures the voltage waveform period and computes the sampling interval and number of samples. The measurement of average power then takes place over an integer number of cycles. Digitized samples of the voltage and current waveforms are multiplied together and the products accumulated over the measurement period. The sum is divided by the number of samples, scaled, and read out as a 4-digit display of average power.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129876160","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"State Equations of Electrical Drives","authors":"T. Tsuchiya","doi":"10.1109/TIECI.1981.351076","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351076","url":null,"abstract":"The state equations of the super synchronous Scherbius induction motor system and the commutatorless motor are established for the synthesis of a speed control or torque control system using modern control theory and the microprocessor as a controller. In addition, signal delays due to the processing time required to execute the employed control algorithm in a microprocessor and the effect of filters inserted in feedback loops in order to eliminate harmonics are considered.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"2673 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114849371","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Necessary and Sufficient Conditions for the Stability of Buck-Type Switched-Mode Power Supplies","authors":"N. Philips, G. Francois","doi":"10.1109/TIECI.1981.351082","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351082","url":null,"abstract":"Necessary and sufficient conditions are derived for the small-signal stability of forward (buck-type) switched-mode power supplies with a constant switching frequency in the continuous conduction mode. It is shown that the maximum allowable gain of the error amplifier is a function of the modulation process, the duty cycle of the switch, and the filter elements of the supply. Under certain conditions, the gain can be made infinitely large. This can occur for duty cycles less than 50 percent if the end of the ``on'' time is modulated and for duty cycles between 50 and 100 percent if the start of the ``on'' time is modulated. Excellent agreement with computer simulations and laboratory measurements has been observed.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"29 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128821158","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Sampling Period and Stability Analysis for the Microcomputer-Based Motor Control Systems","authors":"Hsiao-Chuan Wang","doi":"10.1109/TIECI.1981.351032","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351032","url":null,"abstract":"This paper investigates the stability and sampling problems in the microcomputer-based motor control systems. When a microcomputer is used to perform the control algorithm and to monitor the motor speed, the sampling rate and the controller parameters must be chosen so that the sampled-data system is stable. In this paper, two typical motor control systems are studied; one is based on frequency comparison, and the other on the use of a phase-locked loop. The result shows that the sampling period has a stable region when the system constants and the controller parameters are given. The paper also reveals the information for determining the measuring time and the controller parameters.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"109 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125583526","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Microcomputer-Based Adaptive Observer for Nonlinear Systems","authors":"N. Sinha, S. Law, M. H. Li","doi":"10.1109/TIECI.1981.351039","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351039","url":null,"abstract":"The use of a Luenberger-type observer with an adaptive filter is discussed for estimating the states of a nonlinear system from the measurements of the output of the system, which may be contaminated with noise. Software development as well as experiments on implementation using an Intel MDS 800 microcomputer system are described in detail.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132540454","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Microprocessor Control of a 500-to 1000-MHz Microwave Sweep Oscillator","authors":"R. Bosisio, R. Champagne","doi":"10.1109/TIECI.1981.351034","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351034","url":null,"abstract":"This paper describes a microwave sweep frequency oscillator operated by means of a microprocessor. The frequency of the oscillation depends on the control of a YIG (Yittrium Iron Garnet) filter and an electronic phase shifter placed in a closed loop with amplifiers. The frequency is controlled directly by a Rockwell AIM 65 microprocessor in both fixed-and swept-frequency operating modes.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"63 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129180772","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Universal Process Control Interface","authors":"Carlos J. Távora, G. Batten","doi":"10.1109/TIECI.1981.351033","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351033","url":null,"abstract":"The Interface Configuration Adapter (ICA) implements most process I/O interfaces through four independently configured ports. Each port is configured under software control to interface ac, dc, or digital signals. An ICA based interface board can replace a multiplicity of signal-oriented interface boards. The ICA is inherently testable.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115259364","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Steady-State Processes in Cycloconverters---Part I: High-Frequency Cycloconverters (Cycloinverters)","authors":"M. Slonim, P. Biringer","doi":"10.1109/TIECI.1981.351037","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351037","url":null,"abstract":"A method to analyze the commutation processes in cycloconverters is described, both idealized and real cases are analyzed. The equations of the commutation processes and the output characteristics of the cycloconverters are obtained.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"IECI-28 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130919339","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A Device for the Remote Sensing of the Temperature of High-Voltage Transmission Conductors","authors":"S. J. Collocott","doi":"10.1109/TIECI.1981.351035","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351035","url":null,"abstract":"A device is described for measuring temperature and other parameters of high-voltage transmission-line conductors. A transmitter at line potential sends data from seven multiplexed transducers to a ground-based receiver through a fiber-optic link. The system is linear in operation throughout, the data being encoded onto the optical fiber by a voltage-to-frequency converter.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127063477","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Transient Analysis of Chopper-Fed DC Series Motor","authors":"G. Dubey, W. Shepherd","doi":"10.1109/TIECI.1981.351041","DOIUrl":"https://doi.org/10.1109/TIECI.1981.351041","url":null,"abstract":"The paper deals with the transient analysis of a de series motor, controlled by a chopper with time-ratio control (TRC) or current-limit (CLC) control with square-wave output voltage. Three methods of transient analysis are derived for TRC control and compared with regard to accuracy and usefulness. The methods require much less computation time than is necessary for a step-by-step solution of the system differential equations, for different intervals of the chopper cycle. Two of the methods can be used for deriving transfer functions of the time-ratio chopper-controlled de series motor for small-signal perturbations around a steady-state point.","PeriodicalId":109541,"journal":{"name":"IEEE Transactions on Industrial Electronics and Control Instrumentation","volume":"79 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1981-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123906823","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}