IEEE Nuclear Science Symposium Conference Record, 2005最新文献

筛选
英文 中文
The second generation HRRT - a multi-centre scanner performance investigation 第二代HRRT -多中心扫描仪性能调查
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-12-01 DOI: 10.1109/NSSMIC.2005.1596770
V. Sossi, H. de Jong, W. Barker, P. Bloomfield, Z. Burbar, M. Camborde, C. Comtat, L. Eriksson, S. Houle, D. Keator, C. Knob, R. Krais, A. Lammertsma, A. Rahmim, M. Sibomana, M. Teras, C. Thompson, R. Trébossen, J. Votaw, M. Walker, K. Wienhard, D. Wong
{"title":"The second generation HRRT - a multi-centre scanner performance investigation","authors":"V. Sossi, H. de Jong, W. Barker, P. Bloomfield, Z. Burbar, M. Camborde, C. Comtat, L. Eriksson, S. Houle, D. Keator, C. Knob, R. Krais, A. Lammertsma, A. Rahmim, M. Sibomana, M. Teras, C. Thompson, R. Trébossen, J. Votaw, M. Walker, K. Wienhard, D. Wong","doi":"10.1109/NSSMIC.2005.1596770","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596770","url":null,"abstract":"The high resolution research tomograph (HRRT) is one of the most complex existing positron emission tomographs: it is the only human size scanner capable of decoding the depth of the /spl gamma/-ray interaction in the crystal, using a lutetium LSO/LYSO phoswich detector arrangement. In this study we determined basic scanner hardware characteristics, such as scanner data acquisition stability, and their variability across eleven centres. In addition a subset of the NEMA NU-2001 standards measurements was performed. We found (i) significant variability in the DOI decoding results between centres, (ii) a trend toward an increasing number of detected true coincident events as a function of elapsed time from scanner calibration likely due to a shifting energy spectrum, (iii) a count-rate dependent layer identification, (iv) scatter fraction ranging from /spl sim/ 42% to 54% where the variability was partly related to the shifting of the energy spectrum, (v) sensitivity ranging from /spl sim/5.5% to 6.5% across centres, (vi) resolution of /spl sim/(2.5 mm)/sup 3/, fairly consistent across centres, (vii) image quality which is very comparable to other scanners.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121800728","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 104
Advanced gaseous photodetectors for hyperspectroscopy and other applications 用于超光谱学和其他应用的先进气体光电探测器
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-11-25 DOI: 10.1109/NSSMIC.2005.1596972
I. Rodionov, J. Bidault, I. Crotty, P. Fonte, F. Galy, V. Peskov, O. Zanette
{"title":"Advanced gaseous photodetectors for hyperspectroscopy and other applications","authors":"I. Rodionov, J. Bidault, I. Crotty, P. Fonte, F. Galy, V. Peskov, O. Zanette","doi":"10.1109/NSSMIC.2005.1596972","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596972","url":null,"abstract":"Hyperspectroscopy is a new method of surface image taking, providing simultaneously high position and spectral resolutions which allow one to make some conclusions about chemical compositions of the surfaces. For image taking advanced MCPs are currently used, sensitive in the spectral interval of 450-850 nm. One of the aims of this work is to extend the hyperspectroscopic method to the UV region of spectra: 185-280 nm. For this we have developed and successfully tested innovative 1D and 2D UV sealed photosensitive gaseous detectors with resistive electrodes. These detectors are superior MCPs due to the very low rate of noise pulses and thus due to the high signal to noise ratio. Other important features of these detectors are that they have excellent position resolutions - 30 mum in digital form, are vibration stable and are spark protected. The first results from the application of these detectors for spectroscopy, hyperspectroscopy and the flame detection are presented","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"154 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127226135","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
The X-ray telescope of the CAST experiment CAST实验的x射线望远镜
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-11-14 DOI: 10.1109/NSSMIC.2005.1596436
R. Kotthaus, H. Bräuninger, P. Friedrich, R. Hartmann, D. Kang, M. Kuster, Gerhard Lutz, L. Struder
{"title":"The X-ray telescope of the CAST experiment","authors":"R. Kotthaus, H. Bräuninger, P. Friedrich, R. Hartmann, D. Kang, M. Kuster, Gerhard Lutz, L. Struder","doi":"10.1109/NSSMIC.2005.1596436","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596436","url":null,"abstract":"The CERN Axion Solar Telescope (CAST) searches for solar axions employing a 9 tesla superconducting dipole magnet equipped with 3 independent detection systems for X-rays from axion-photon conversions inside the 10 m long magnetic field. Results of the first 6 months of data taking in 2003 imply a 95% CL upper limit on the axion-photon coupling constant of gagamma < 1.16times10-10 GeV-1 for axion masses ma < 0.02 eV. The most sensitive detector of CAST is an X-ray telescope consisting of a Wolter I type mirror system and a fully depleted pn-CCD as focal plane detector. Exploiting the full potential of background suppression by focussing X-rays emerging from the magnet bore, the axion sensitivity obtained with telescope data taken in 2004, for the first time in a controlled laboratory experiment, will supersede axion constraints derived from stellar energy loss arguments","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125273345","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Characterization of a PET camera optimized for prostate imaging 一种用于前列腺成像优化的PET相机的特性
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-11-11 DOI: 10.1109/NSSMIC.2005.1596615
J. Huber, W. Choong, W. Moses, J. Qi, J. Hu, G. Wang, D. Wilson, S. Oh, R. Huesman, S. Derenzo
{"title":"Characterization of a PET camera optimized for prostate imaging","authors":"J. Huber, W. Choong, W. Moses, J. Qi, J. Hu, G. Wang, D. Wilson, S. Oh, R. Huesman, S. Derenzo","doi":"10.1109/NSSMIC.2005.1596615","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596615","url":null,"abstract":"We present the characterization of a positron emission tomograph for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis). The distance between detector banks adjusts to allow patient access and to position the detectors as closely as possible for maximum sensitivity with patients of various sizes. Each bank is composed of two axial rows of 20 HR+ block detectors for a total of 80 detectors in the camera. The individual detectors are angled in the transaxial plane to point towards the prostate to reduce resolution degradation in that region. The detectors are read out by modified HRRT data acquisition electronics. Compared to a standard whole-body PET camera, our dedicated-prostate camera has the same sensitivity and resolution, less background (less randoms and lower scatter fraction) and a lower cost. We have completed construction of the camera. Characterization data and reconstructed images of several phantoms are shown. Sensitivity of a point source in the center is 946 cps/muCi. Spatial resolution is 4 mm FWHM in the central region","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"24 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125960667","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Dual-modality PET/ultrasound imaging of the prostate 前列腺PET/超声双模成像
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-11-11 DOI: 10.1109/NSSMIC.2005.1596768
J. Huber, W. Moses, J. Pouliot, I. Hsu
{"title":"Dual-modality PET/ultrasound imaging of the prostate","authors":"J. Huber, W. Moses, J. Pouliot, I. Hsu","doi":"10.1109/NSSMIC.2005.1596768","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596768","url":null,"abstract":"Functional imaging with positron emission tomography (PET) will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor \"aggressiveness.\" However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate. Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"05 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128773907","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
High efficiency detection of argon scintillation light of 128 nm using LAAPDs laapd对128 nm氩闪烁光的高效检测
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-11-10 DOI: 10.1109/NSSMIC.2005.1596232
R. Chandrasekharan, A. Knecht, M. Messina, C. Regenfus, A. Rubbia
{"title":"High efficiency detection of argon scintillation light of 128 nm using LAAPDs","authors":"R. Chandrasekharan, A. Knecht, M. Messina, C. Regenfus, A. Rubbia","doi":"10.1109/NSSMIC.2005.1596232","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596232","url":null,"abstract":"The possibility of efficient collection and detection of vacuum ultraviolet light as emitted by argon, krypton, and xenon gas is studied. Absolute quantum efficiencies of large area avalanche photodiodes (LAAPDs) are derived at these wavelengths. VUV light of wavelengths down to the 128 nm of Ar emission is shown to be detectable with silicon avalanche photodiodes at quantum efficiencies above 42%. Flexible Mylar foil overcoated with Al+MgF2 is measured to have a specular reflectivity of ~91% at argon emission wavelength. Low-pressure argon gas is shown to emit significant amounts of non-UV radiation. The average energy expenditure for the creation of non-UV photons in argon gas at this pressure is measured to be below 378 eV","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"65 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127749877","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Comparing imaging and non-imaging techniques for reducing background clutter and resolving distant point sources 比较成像和非成像技术减少背景杂波和分辨远距离点源
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-11-10 DOI: 10.1109/NSSMIC.2005.1596266
R. Wurtz, K. Ziock, L. Fabris, R. Graham
{"title":"Comparing imaging and non-imaging techniques for reducing background clutter and resolving distant point sources","authors":"R. Wurtz, K. Ziock, L. Fabris, R. Graham","doi":"10.1109/NSSMIC.2005.1596266","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596266","url":null,"abstract":"To reach maximum sensitivity, any method used to search for orphan sources must be insensitive to local variations of the background. Using imaging and non-imaging techniques, we analyzed the same data acquired by a large-area, coded-mask-imager search instrument. Data from many passes past a 1 mCi source at 65 m from the instrument were used to construct a model of the instrument response. We then used the model to \"hide\" the source in data taken in a light urban environment. We compared the success of detecting the hidden sources using coded-mask imaging methods, pseudo-imaging based on a zero-area matched filter, and non-imaging using simple thresholding. The results clearly indicate the superiority of imaging with the coded-mask techniques returning the best results","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"52 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122948665","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Imaging performance of the Si/Ge hybrid Compton imager Si/Ge混合康普顿成像仪的成像性能
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-11-10 DOI: 10.1109/NSSMIC.2005.1596196
M. Burks, D. Chivers, C. Cork, M. Cunningham, L. Fabris, D. Gunter, E. Hull, D. Lange, H. Manini, L. Mihailescu, K. Nelson, T. Niedermayr, J. Valentine, K. Vetter, D. Wright
{"title":"Imaging performance of the Si/Ge hybrid Compton imager","authors":"M. Burks, D. Chivers, C. Cork, M. Cunningham, L. Fabris, D. Gunter, E. Hull, D. Lange, H. Manini, L. Mihailescu, K. Nelson, T. Niedermayr, J. Valentine, K. Vetter, D. Wright","doi":"10.1109/NSSMIC.2005.1596196","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596196","url":null,"abstract":"The point spread function (PSF) of a fully-instrumented silicon/germanium Compton telescope has been measured as a function of energy and angle. Overall, the resolution was 3deg to 4deg FWHM over most of the energy range and field of view. The various contributions to the resolution have been quantified. These contributions include the energy and position uncertainty of the detector; source energy; Doppler broadening; and the 1/r broadening characteristic of Compton back-projection. Furthermore, a distortion of the PSF is observed for sources imaged off-axis from the detector. These contributions are discussed and compared to theory and simulations","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114724263","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Improved spatial resolution in thick, fully-depleted CCDs with enhanced red sensitivity 提高了厚的、完全耗尽的ccd的空间分辨率,增强了红色灵敏度
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-11-10 DOI: 10.1109/NSSMIC.2005.1596437
J. Fairfield
{"title":"Improved spatial resolution in thick, fully-depleted CCDs with enhanced red sensitivity","authors":"J. Fairfield","doi":"10.1109/NSSMIC.2005.1596437","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596437","url":null,"abstract":"The point spread function (PSF) is an important measure of spatial resolution in CCDs for point-like objects, since it can affect use in imaging and spectroscopic applications. We present new data and theoretical developments in the study of lateral charge diffusion in thick, fully-depleted charge-coupled devices (CCDs) developed at Lawrence Berkeley National Laboratory (LBNL). Because they are fully depleted, the LBNL devices have no field-free region, and diffusion can be controlled through the application of an external bias voltage. We give results for a 3512times3512 format, 10.5 mum pixel back-illuminated p-channel CCD developed for the SuperNova/Acceleration Probe (SNAP), a proposed satellite-based experiment designed to study dark energy. The PSF was measured at substrate bias voltages between 3 V and 115 V. At a bias voltage of 115 V, we measure an rms diffusion of 3.7plusmn0.2 mum. Lateral charge diffusion in LBNL CCDs is thus expected to meet the SNAP requirements","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124988703","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Neutron resonance radiography for explosives detection: technical challenges 用于炸药探测的中子共振射线照相:技术挑战
IEEE Nuclear Science Symposium Conference Record, 2005 Pub Date : 2005-11-09 DOI: 10.1109/NSSMIC.2005.1596222
W. Raas, B. Blackburn, E. Boyd, J. Hall, G. Kohse, R. Lanza, B. Rusnak, J. Watterson
{"title":"Neutron resonance radiography for explosives detection: technical challenges","authors":"W. Raas, B. Blackburn, E. Boyd, J. Hall, G. Kohse, R. Lanza, B. Rusnak, J. Watterson","doi":"10.1109/NSSMIC.2005.1596222","DOIUrl":"https://doi.org/10.1109/NSSMIC.2005.1596222","url":null,"abstract":"Fast neutron resonance radiography (NRR) has recently become a focus of investigation as a supplement to conventional X-ray systems as a non-invasive, non-destructive means of detecting explosive material concealed in checked luggage or cargo containers at airports. Using fast (1-6 MeV) neutrons produced by the D(d,n)3He reaction, NRR provides both an imaging capability and the ability to determine the chemical composition of materials in baggage or cargo. Elemental discrimination is achieved by exploiting the resonance features of the neutron cross-section for oxygen, nitrogen, carbon, and hydrogen. Simulations have shown the effectiveness of multiple-element NRR through Monte Carlo transport methods; this work is focused on the development of a prototype system that will incorporate an accelerator-based neutron source and a neutron detection and imaging system to demonstrate the realistic capabilities of NRR in distinguishing the elemental components of concealed objects. Preliminary experiments have exposed significant technical difficulties unapparent in simulations, including the presence of image contamination from gamma ray production, the detection of low-fluence fast neutrons in a gamma field, and the mechanical difficulties inherent in the use of thin foil windows for gas cell confinement. To mitigate these concerns, a new gas target has been developed to simultaneously reduce gamma ray production and increase structural integrity in high flux gas targets. Development of a neutron imaging system and neutron counting based on characteristic neutron pulse shapes have been investigated as a means of improving signal to noise ratios, reducing irradiation times, and increasing the accuracy of elemental determination","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2005-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123059953","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信