Improved spatial resolution in thick, fully-depleted CCDs with enhanced red sensitivity

J. Fairfield
{"title":"Improved spatial resolution in thick, fully-depleted CCDs with enhanced red sensitivity","authors":"J. Fairfield","doi":"10.1109/NSSMIC.2005.1596437","DOIUrl":null,"url":null,"abstract":"The point spread function (PSF) is an important measure of spatial resolution in CCDs for point-like objects, since it can affect use in imaging and spectroscopic applications. We present new data and theoretical developments in the study of lateral charge diffusion in thick, fully-depleted charge-coupled devices (CCDs) developed at Lawrence Berkeley National Laboratory (LBNL). Because they are fully depleted, the LBNL devices have no field-free region, and diffusion can be controlled through the application of an external bias voltage. We give results for a 3512times3512 format, 10.5 mum pixel back-illuminated p-channel CCD developed for the SuperNova/Acceleration Probe (SNAP), a proposed satellite-based experiment designed to study dark energy. The PSF was measured at substrate bias voltages between 3 V and 115 V. At a bias voltage of 115 V, we measure an rms diffusion of 3.7plusmn0.2 mum. Lateral charge diffusion in LBNL CCDs is thus expected to meet the SNAP requirements","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596437","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

The point spread function (PSF) is an important measure of spatial resolution in CCDs for point-like objects, since it can affect use in imaging and spectroscopic applications. We present new data and theoretical developments in the study of lateral charge diffusion in thick, fully-depleted charge-coupled devices (CCDs) developed at Lawrence Berkeley National Laboratory (LBNL). Because they are fully depleted, the LBNL devices have no field-free region, and diffusion can be controlled through the application of an external bias voltage. We give results for a 3512times3512 format, 10.5 mum pixel back-illuminated p-channel CCD developed for the SuperNova/Acceleration Probe (SNAP), a proposed satellite-based experiment designed to study dark energy. The PSF was measured at substrate bias voltages between 3 V and 115 V. At a bias voltage of 115 V, we measure an rms diffusion of 3.7plusmn0.2 mum. Lateral charge diffusion in LBNL CCDs is thus expected to meet the SNAP requirements
提高了厚的、完全耗尽的ccd的空间分辨率,增强了红色灵敏度
点扩展函数(PSF)是点状物体ccd空间分辨率的重要度量,因为它会影响成像和光谱应用的使用。我们提出了在劳伦斯伯克利国家实验室(LBNL)开发的厚的、完全耗尽的电荷耦合器件(ccd)中横向电荷扩散研究的新数据和理论进展。由于它们完全耗尽,LBNL器件没有无场区域,并且可以通过施加外部偏置电压来控制扩散。我们给出了为超新星/加速探测器(SNAP)开发的3512倍3512格式10.5万像素背照p通道CCD的结果,这是一项旨在研究暗能量的卫星实验。在基片偏置电压3 V至115 V之间测量PSF。在115 V的偏置电压下,我们测量到的均方根扩散为3.7±0.2 μ m。因此,LBNL ccd的横向电荷扩散有望满足SNAP要求
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信