Proceedings of 1996 Transmission and Distribution Conference and Exposition最新文献

筛选
英文 中文
Practical method for evaluating ground fault current distribution in station supplied by an unhomogeneous line 评估非均匀线路供电站接地故障电流分布的实用方法
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.545953
L. Popovic
{"title":"Practical method for evaluating ground fault current distribution in station supplied by an unhomogeneous line","authors":"L. Popovic","doi":"10.1109/TDC.1996.545953","DOIUrl":"https://doi.org/10.1109/TDC.1996.545953","url":null,"abstract":"The paper presents an analytical procedure which enables a quick and, at the design stage, correct evaluation of the ground fault current distribution, for a fault in a substation supplied by a line composed of two or more uniform and different sections. The advantages of the method are based on the simplicity and accuracy of the formulae for solving uniform lumped parameter ladder circuits of any size and under any terminal conditions. The formulae are obtained by applying the \"general equations of the line represented by discrete parameters\" on a specific electrical circuit formed by a transmission line ground wire during ground faults. The paper also derives simple and tract expressions for solving ladder circuits formed by the discretization of underground conductors which are in continuous contact with earth (e.g. the sheaths of a cable, an interconnecting copper buried in the soil, a pipeline, etc.). The correct prediction of the expected ground fault current parts in soil and neutral conductors is of great importance in designing safe and economical substation grounding installations.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121169612","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 33
Accelerated life tests on a new water tree retardant insulation for power cables 新型水树阻燃电力电缆绝缘加速寿命试验
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.547547
H. Sarma
{"title":"Accelerated life tests on a new water tree retardant insulation for power cables","authors":"H. Sarma","doi":"10.1109/TDC.1996.547547","DOIUrl":"https://doi.org/10.1109/TDC.1996.547547","url":null,"abstract":"This paper describes the results of an investigation in which 15 kV rated cables insulated with a new water tree retardant cross-linked polyethylene (TR XLPE) were subjected to accelerated aging tests under a controlled voltage stress and thermal load cycle conditions. Cables insulated with conventional XLPE and commercially available TR XLPE were used as reference test populations to affirm the test methodology. Under the chosen conditions, cable life of the new TR XLPE as calculated using Weibull and log normal statistical distributions, was more than twice that for the reference TR XLPE. Extensive diagnostic measurements (water content, dissipation factor, water tree analysis) were performed on failed cable samples to bring out the differences between the three insulations. Electron micrographic investigations revealed the size and distribution of micro voids in the new TR XLPE to be smaller supporting its extended life under these tests. The experimental details of the accelerated life tests are also documented in a clear manner facilitating any archival of the data for future analysis and comparison.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121375775","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Expert system application for voltage and VAr control in power transmission and distribution systems 专家系统在输配电系统电压和无功控制中的应用
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.547567
T. Le, M. Negnevitsky
{"title":"Expert system application for voltage and VAr control in power transmission and distribution systems","authors":"T. Le, M. Negnevitsky","doi":"10.1109/TDC.1996.547567","DOIUrl":"https://doi.org/10.1109/TDC.1996.547567","url":null,"abstract":"This paper presents an application of the steady state network equivalents and expert system for voltage and reactive power (VAr) control in large-scale power systems. A steady state network equivalencing technique is used to construct the \"three tier\" subsystem which is adequate to solve voltage violation problems. An expert system utilises the sensitivity tree method to select the optimal set of control actions to alleviate the voltage problem. The expert system was developed using the VP-EXPERT system shell. VP-EXPERT interacts with the power system analysis software providing analysis of the network sensitivity matrix and data for the knowledge base. Practical application of the developed expert system is demonstrated on the example of the Hydro-Electric Commission (HEC) power system of Tasmania, however the proposed approach is not limited by the system size.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126623419","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Newton-Raphson method in complex form [power flow analysis] 复形牛顿-拉夫逊法[潮流分析]
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.547577
Hieu Le Nguyen
{"title":"Newton-Raphson method in complex form [power flow analysis]","authors":"Hieu Le Nguyen","doi":"10.1109/TDC.1996.547577","DOIUrl":"https://doi.org/10.1109/TDC.1996.547577","url":null,"abstract":"A new algorithm that is used for the solution of three-phase (or unsymmetrical) power flow analysis of both transmission or distribution systems under unsymmetrical operating conditions and power quality problems, is presented. This is new and robust, and is developed on the extension of the Newton-Raphson method and its Jacobian in complex form, that gives the solutions in whole phasor format. A comparative example is presented to illustrate the convergence characteristics of proposed method.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"51 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123776385","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 24
Comparative field tests of various practices for the control of wind-induced conductor motion 控制风致导体运动的各种方法的现场比较试验
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.545958
P. Van Dyke, C. Hardy, M. St-Louis, J. Gardes
{"title":"Comparative field tests of various practices for the control of wind-induced conductor motion","authors":"P. Van Dyke, C. Hardy, M. St-Louis, J. Gardes","doi":"10.1109/TDC.1996.545958","DOIUrl":"https://doi.org/10.1109/TDC.1996.545958","url":null,"abstract":"This paper deals with an experimental assessment of the performance of different damping systems in controlling wind-induced conductor motions. The damping systems comprised different types of Stockbridge dampers or bretelles used an single ACSR and MAC conductors as well as spacer-dampers or semi-rigid spacers combined or not with bretelles used on similar triple or quad bundled conductors. All tests were conducted under natural wind conditions at the Hydro-Quebec test line in Varennes, Quebec.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122805315","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Current measurements using optical power 使用光功率测量电流
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.545937
J. Werthen, A. Andersson, S. Weiss, H. Bjørklund
{"title":"Current measurements using optical power","authors":"J. Werthen, A. Andersson, S. Weiss, H. Bjørklund","doi":"10.1109/TDC.1996.545937","DOIUrl":"https://doi.org/10.1109/TDC.1996.545937","url":null,"abstract":"Fiber optic systems are becoming increasingly important for measurements of current, voltage and temperature in high voltage environments. Conventional electrical wiring such as a current transformer can readily be replaced by noise-free fiber optics. With an optically powered data link and a transducer, direct current, voltage and temperature measurements have been successfully demonstrated. The system includes two modules connected by optical fiber up to 1 km in length. One module is placed at a control site. It supplies optical power for transmission to, and receives data from, the measurement module, which is placed at a remote site, in this case at high voltage. This remote module converts the optical power into electrical power for the electronic circuitry, the transducer and a data communications link. The analog voltage from the transducer is fed into an analog to digital converter. Test results verify successful operation with a sampling rate of 33.3 kHz. Taking anti-aliasing filters into account, an equivalent analog bandwidth of 10 kHz was achieved with an overall resolution of 0.025% (12 bits) and a 0.2% accuracy. Together with modern digital relays this technology offers new reliable ways to improve the protection of high voltage systems. Fully operational over the temperature range -40/spl deg/C to +85/spl deg/C, the system is sufficient for most electric power applications.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"25 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131444541","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 31
Risk assessment basis of moving particles in gas insulated substations 气体绝缘变电站移动粒子风险评价依据
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.545933
M. Runde, T. Aurud, J. Nokleby, B. Skyberg, K. Ljøkelsøy, L. Lundgaard
{"title":"Risk assessment basis of moving particles in gas insulated substations","authors":"M. Runde, T. Aurud, J. Nokleby, B. Skyberg, K. Ljøkelsøy, L. Lundgaard","doi":"10.1109/TDC.1996.545933","DOIUrl":"https://doi.org/10.1109/TDC.1996.545933","url":null,"abstract":"Comprehensive acoustic measurements on bouncing particles in a GIS have been carried out. The objective is to find parameters that are both available from external acoustic measurements and usable for assessing whether a particle has the potential to cause an insulation breakdown. The elapsed time between subsequent particle impacts is a measure of how far into the high-field region the particle can move, and thus also a measure on criticality. Secondly, the amplitude of the acoustic signal generated as a particle impacts the enclosure increases with increasing particle length and thus also with increasing criticality. Moreover, plotting these two parameters against each other ('particle flight time' vs. 'signal amplitude at impact') for a significant number of impacts (e.g. 1000) always yields a very characteristic pattern, which in itself is a strong indication that the recorded signals are generated by one moving particle.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125522908","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
A distributed on-line HV transmission condition monitoring information system 一种分布式在线高压输电状态监测信息系统
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.545914
W. L. Chan, T. M. Chan, S. Pang, A. So
{"title":"A distributed on-line HV transmission condition monitoring information system","authors":"W. L. Chan, T. M. Chan, S. Pang, A. So","doi":"10.1109/TDC.1996.545914","DOIUrl":"https://doi.org/10.1109/TDC.1996.545914","url":null,"abstract":"China Light and Power Company Ltd. (CLP) is responsible for supplying electricity to the whole of Hong Kong except Hong Kong Island and Lamma Island. In CLP's Castle Peak power plant, 18 kV and 23 kV electric supplies are generated. The voltage is then stepped up to 400 kV for transmission. The intermediate control between those transformers and the major 400 kV overhead transmission system lies with a standard \"one and a half breaker configuration\" switch substation. The substation houses single phase encapsulated SF/sub 6/ circuit breakers. In the urban centres, 400 kV substations are installed to step down 40 kV to 132 kV or further to 11 kV for distribution. This paper describes the development of an online distributed information system for monitoring the conditions of the whole HV transmission system. The system continuously monitors the status of each circuit breaker (CB) together with important operational parameters, such as duration during making and breaking, operations of hydraulic pumps and SF/sub 6/ gas pressure etc. Each group of (CB) is monitored by a standalone microcontroller which is interconnected with all other microcontrollers using a local area network with a baud rate of 9600. The information can be recorded on the hard-disk of an on-site microcomputer and further transmitted back to a remote computer for alarm generation and multi-station supervision. The CLP 400 kV substation and the Tsz Wan Shan 400 kV substation are amongst the first targets for development.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"128 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128211170","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
New silicone cold shrink termination 新型硅胶冷缩终止
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.547545
R. A. Wandmacher, J. A. Morris, T. Heyer, Lawrence C. Chor
{"title":"New silicone cold shrink termination","authors":"R. A. Wandmacher, J. A. Morris, T. Heyer, Lawrence C. Chor","doi":"10.1109/TDC.1996.547545","DOIUrl":"https://doi.org/10.1109/TDC.1996.547545","url":null,"abstract":"A new cold shrink termination developed by application of materials science and computer design optimization is presented. This new termination has improved electrical and environmental performance with a shorter length and simplified installation procedures. This paper describes the component materials, design, and electrical performance of a new cold shrink (elastically recoverable) termination.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"44 3","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120842186","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Three-phase 36-step voltage converter system with an additional single-phase converter for voltage shaping 三相36步电压转换器系统与一个额外的单相转换器电压整形
Proceedings of 1996 Transmission and Distribution Conference and Exposition Pub Date : 1996-09-15 DOI: 10.1109/TDC.1996.545955
K. Oguchi
{"title":"Three-phase 36-step voltage converter system with an additional single-phase converter for voltage shaping","authors":"K. Oguchi","doi":"10.1109/TDC.1996.545955","DOIUrl":"https://doi.org/10.1109/TDC.1996.545955","url":null,"abstract":"A novel double AC/DC converter system with 36-step input voltages is proposed. This system consists of two three-phase neutral-point-clamped (NPC) converters and an additional single-phase NPC converter. The main converters operate at a switching frequency of a power line frequency and the additional converter operates at a switching frequency of nine times that of the power line frequency. The proposed system is suitable for high-power applications because of a relatively low switching frequency and less distorted input voltages.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129565814","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书