The journal of adhesive dentistry最新文献

筛选
英文 中文
Evaluation of Micro-Shear Bond Strength of Self-Adhesive Flowable Giomer To Bovine Tooth. 自粘流动异构体与牛牙的微剪切粘接强度评价。
IF 2.7
The journal of adhesive dentistry Pub Date : 2026-04-17 DOI: 10.3290/j.jad.c_2654
Eunjin Kim, Yooseok Shin, Dohyun Kim, Jeong-Hee Kim, Ran-Ah Kim, Jeong-Won Park
{"title":"Evaluation of Micro-Shear Bond Strength of Self-Adhesive Flowable Giomer To Bovine Tooth.","authors":"Eunjin Kim, Yooseok Shin, Dohyun Kim, Jeong-Hee Kim, Ran-Ah Kim, Jeong-Won Park","doi":"10.3290/j.jad.c_2654","DOIUrl":"10.3290/j.jad.c_2654","url":null,"abstract":"<p><strong>Purpose: </strong>Self-adhesive flowable giomer (SAG) has been used in dental practice recently to simplify clinical procedures and shorten chair times. However, there are only few studies evaluating its bond strength to enamel and dentin, resulting in a lack of evidence. The purpose of this study was to compare the micro-shear bond strength with and without adhesive in enamel and dentin to evaluate the self-adhesive ability of SAG.</p><p><strong>Methods and materials: </strong>Sound bovine teeth were used as the tooth substrates. For μ-SBS tests, enamel and dentin specimens were prepared for SAG (Beautifil Kids SA - BK), a self-adhesive flowable composite (Vertise Flow - VF), and a nanohybrid flowable giomer (Beautifil Flow Plus F03 - BF). Two adhesive modes were tested for BK and VF (with self-etching adhesive and no adhesive), and one for BF (with self-etching adhesive). The μ-SBS test was conducted after 24 h and after thermocycling for 10,000 cycles using a universal testing machine.</p><p><strong>Results: </strong>For all materials, when self-etching adhesive was used, the μ-SBS was significantly higher than that of the no-adhesive group (P 0.05). No statistically significant difference was found between the restorative materials under any condition. Thermocycling had no significant effect on the μ-SBS of BK. In the self-etching adhesive group, mixed failure was predominant for all materials. However, in no-adhesive group, adhesive failure and mixed failure were observed at similar levels for all materials.</p><p><strong>Conclusion: </strong>The self-adhesive resin without adhesive showed lower bonding strength in both enamel and dentin compared to the one with adhesive.</p><p><strong>Clinical relevance: </strong>Although there were no significant differences in bond strength stability between materials, SAG still offers a simplified bonding process without compromising bond strength, making it a viable option for clinical use.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"28 ","pages":"39-47"},"PeriodicalIF":2.7,"publicationDate":"2026-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13092815/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147701345","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Too Wet, Too Dry? Influence of Water Contamination and Overdrying on the Bond Strength of a Universal Adhesive to Dentin. 太湿,太干?水污染和过度干燥对通用胶粘剂与牙本质结合强度的影响。
IF 2.7
The journal of adhesive dentistry Pub Date : 2026-03-27 DOI: 10.3290/j.jad.c_2521
Malte Peters, Carolin Mempel, Kirstin Vach, Silke Jacker-Guhr, Nadine Schlueter, Anne-Katrin Luehrs
{"title":"Too Wet, Too Dry? Influence of Water Contamination and Overdrying on the Bond Strength of a Universal Adhesive to Dentin.","authors":"Malte Peters, Carolin Mempel, Kirstin Vach, Silke Jacker-Guhr, Nadine Schlueter, Anne-Katrin Luehrs","doi":"10.3290/j.jad.c_2521","DOIUrl":"10.3290/j.jad.c_2521","url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this in vitro study was to measure the microtensile bond strength (μTBS) and the contact angle of a universal adhesive (Prime & Bond Active) to overdried and water-contaminated human dentin.</p><p><strong>Materials and methods: </strong>After exposing flat dentin surfaces (5×5 mm2) of 60 caries- and restoration-free molars, test groups were either overdried or water-contaminated before adhesive application (self-etch) or after phosphoric acid etching (etch&rinse). In control groups, the adhesive was applied according to the manufacturer's instructions. μTBS (n = 45 samples) was analyzed (24 h/thermocycling: 15,000 cycles, 5/55°C). Fracture patterns were assessed microscopically. Contact angles were measured using the sessile drop method. Statistical analysis was performed using Tobit regression and Scheffé correction for bond strength data and Kruskal-Wallis test for contact angle measurements (α = 0.05).</p><p><strong>Results: </strong>Overall, µTBS was significantly higher after etch&rinse application compared to the self-etch mode before (P 0.001, Δ 11.04 MPa) and after aging (P 0.001, Δ 6.73 MPa). The highest μTBS (29.9 ± 10.4 MPa) was achieved by the etch&rinse control before aging. For etch&rinse application, water contamination and overdrying initially led to significantly lower µTBS compared to the control (P = 0.014/P = 0.007). Aging significantly decreased μTBS in both etch&rinse control and overdry groups (P 0.001/P = 0.036). Fracture modes were predominantly adhesive (90%). Contact angle on water-contaminated dentin was significantly lower for self-etch than for etch&rinse mode (P = 0.008).</p><p><strong>Conclusion: </strong>The adhesive application mode significantly influenced bond strength. Dentin surface condition initially affected the µTBS solely in etch&rinse mode. Only on water-contaminated dentin, the contact angle was influenced by the adhesive application mode.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"28 ","pages":"29-38"},"PeriodicalIF":2.7,"publicationDate":"2026-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13033893/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147535261","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of the Design and Exposure Mode of Different Multiple-Peak Light-Curing Units on Light Emission, Temperature Rise, and Intraoral Access. 不同多峰光固化单元的设计和曝光方式对光发射、温升和口内通路的影响。
IF 2.7
The journal of adhesive dentistry Pub Date : 2026-03-24 DOI: 10.3290/j.jad.c_2598
Maria Tereza Hordones Ribeiro, Guilherme Mendonça Benoni, Maribí Isomar Terán Lozada, Airin Karelys Avendaño Rondon, Gisele Rodrigues da Silva, Carlos José Soares
{"title":"Effect of the Design and Exposure Mode of Different Multiple-Peak Light-Curing Units on Light Emission, Temperature Rise, and Intraoral Access.","authors":"Maria Tereza Hordones Ribeiro, Guilherme Mendonça Benoni, Maribí Isomar Terán Lozada, Airin Karelys Avendaño Rondon, Gisele Rodrigues da Silva, Carlos José Soares","doi":"10.3290/j.jad.c_2598","DOIUrl":"10.3290/j.jad.c_2598","url":null,"abstract":"<p><strong>Purpose: </strong>To measure the tip diameter (mm) and the ability to cover the anterior and posterior large restorations, radiant power (mW), radiant exitance (mW/cm2), emission spectrum (mW/cm2/nm), radiant exposure (J/cm2), the effect of the design on the access to the mouth posterior region, the temperature rise inside the pulp of three light-curing units (LCUs) and a new LCU available in the Brazil.</p><p><strong>Methods and materials: </strong>Four LCUs that cost over US$900, three well-established (Bluephase G2, Ivoclar Vivadent; VALO Grand, Ultradent; and VALO Cordless, Ultradent), and a new LCU (Quazar, FGM) were tested in standard mode (20 s for all LCUs), high mode (3 s for VALO Cordless, 5 s for Quazar, and 20 s for Bluephase G2), and Xtra power mode (3 s for VALO Grand). The radiant power (mW) and emission spectrum (mW/nm) were measured using an integrating sphere connected to a fiberoptic spectroradiometer. The internal tip diameter (mm) of each LCU was measured using a digital caliper and was used to calculate the radiant exitance (mW/cm2). Radiant exitance profiles at the light tip were measured using a laser beam profiler. The radiant exposure (J/cm2) was calculated. The in vitro temperature rise produced by LCUs inside the pulp cavity of molar teeth was measured using a thermocouple. The mouth access of the LCU tip on the occlusal surface of the first mandibular molar tooth with two mouth openings of 25 mm and 45 mm at the incisors was evaluated. The cost of each LCU in Brazil was correlated with internal tip diameter, radiant power, and radiant exitance.</p><p><strong>Results: </strong>All the LCUs were multiple-peak LCUs, and a uniform output. Quazar, VALO Cordless, and VALO Grand could maintain a perpendicular position regardless of mouth interincisal opening, while the Bluephase G2 required a tip angulation of 31.6 degrees at the 25 mm interincisal opening. The VALO Grand and VALO Cordless produced the highest temperature rise in standard mode ( 2.5°C), while in high mode, all LCUs produced lower temperature increases that use 5 s for Quazar and 3 s for VALO Grand and VALO Cordless, except for Bluephase G2, which produced a higher temperature rise ( 2.0°C) when activated for 20 s. There was a positive correlation between the cost of these LCUs and their averaged radiant power, diameter and the radiant exitance.</p><p><strong>Conclusions: </strong>The LCUs tested emit light in the blue and violet spectra, characterizing them as multiple peaks. The temperature increases in the produced pulp remained within safe thermal limits ( 2.5°C), although standard-mode exposures produced higher pulp temperature rises. Bluephase G2 created higher angulation at 25 mm of interincisal mouth opening. The Quazar LCU produced a light output that was comparable to that from leading LCUs.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"28 ","pages":"19-28"},"PeriodicalIF":2.7,"publicationDate":"2026-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13022565/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147505802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of Storage Time After Surface Treatment of Zirconia on Surface Free Energy and Bond Strength of Composite Cement. 氧化锆表面处理后贮存时间对复合水泥表面自由能和粘结强度的影响。
IF 2.7
The journal of adhesive dentistry Pub Date : 2026-03-11 DOI: 10.3290/j.jad.c_2562
Mina Aker Sagen, Heidi Vanessa Holm, Freya Andersen, Per Vult von Steyern
{"title":"Effect of Storage Time After Surface Treatment of Zirconia on Surface Free Energy and Bond Strength of Composite Cement.","authors":"Mina Aker Sagen, Heidi Vanessa Holm, Freya Andersen, Per Vult von Steyern","doi":"10.3290/j.jad.c_2562","DOIUrl":"10.3290/j.jad.c_2562","url":null,"abstract":"<p><strong>Purpose: </strong>Surface treatment of zirconia before cementation can be performed using different methods, e.g. airborne particle abrasion (APA) or various etching protocols. This study evaluated the effect of storage time between surface treatment and cementation on the surface free energy (SFE) of zirconia, the bond strength of composite cement, and failure mode.</p><p><strong>Materials and methods: </strong>Rod-shaped zirconia specimens were fabricated and assigned to two surface treatment groups: APA (n = 80) and hot etching with potassium hydrogen difluoride (KHF2, n = 80). Each group was divided into four storage time subgroups: immediate, 24 h, 1 week, and 1 month. After storage, specimens were either analyzed for SFE (n = 10) or cemented for shear bond strength (SBS) testing and failure mode evaluation (n = 10).</p><p><strong>Results: </strong>Two-way analysis of variance (ANOVA) showed a significant effect of both surface treatment and storage time on SFE (P 0.05), with KHF2-etched zirconia exhibiting the highest values across all time points. In both groups, SFE gradually decreased with increased storage. Surface treatment did not significantly affect SBS (P > 0.05). Storage time significantly influenced SBS (P 0.05), specifically for KHF2-etched zirconia; post-hoc comparisons showed higher SBS after 1 week than at immediate testing (P 0.05). Although adhesive failures to cement increased with longer storage time for KHF2-etched specimens, this trend was not significant (P > 0.05). For APA specimens, the highest incidence of adhesive failures (n = 9) to cement occurred after 24 h of storage.</p><p><strong>Conclusion: </strong>Given the significant decrease in SFE with prolonged storage and adhesive failures to zirconia tended to increase over time, minimizing the interval between surface treatment and cementation is recommended.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"28 ","pages":"11-18"},"PeriodicalIF":2.7,"publicationDate":"2026-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12980088/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"147437613","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of an MDP Salt-Based Surface Cleaner on Bond Strength to Saliva-Contaminated Dentin At Different Stages of a Self-Etch Adhesive Procedure: An In Vitro Pilot Study. 一种MDP盐基表面清洁剂对自蚀刻粘接过程中不同阶段与唾液污染牙本质结合强度的影响:一项体外试验研究。
IF 2.7
The journal of adhesive dentistry Pub Date : 2026-02-09 DOI: 10.3290/j.jad.c_2503
Ruhsan Müdüroğlu Adıgüzel, Leyla Kerimova Köse, Eda Çakmak Aktan, Neslihan Arhun
{"title":"Influence of an MDP Salt-Based Surface Cleaner on Bond Strength to Saliva-Contaminated Dentin At Different Stages of a Self-Etch Adhesive Procedure: An In Vitro Pilot Study.","authors":"Ruhsan Müdüroğlu Adıgüzel, Leyla Kerimova Köse, Eda Çakmak Aktan, Neslihan Arhun","doi":"10.3290/j.jad.c_2503","DOIUrl":"10.3290/j.jad.c_2503","url":null,"abstract":"<p><strong>Purpose: </strong>This in vitro study was designed to assess the influence of KATANA™ Cleaner (KC) on the microshear bond strength (μSBS) of composite resin restorations to saliva-contaminated dentin surfaces at various stages of the bonding process using a two-step self-etch adhesive system.</p><p><strong>Materials and methods: </strong>A total of 140 sound human molars were randomly assigned into 14 groups according to the timing of saliva contamination and the decontamination approach. Saliva contamination was introduced at critical phases of adhesive application (before primer, after primer, after bond application, and after bond polymerization). KC was used for surface decontamination where applicable. Clearfil SE Bond adhesive and Filtek Z250 composite resin were applied using standardized procedures. μSBS test was performed after 24-h water storage, and failure modes were analyzed using stereomicroscopy. Additionally, dentin surfaces were evaluated under SEM. EDS was employed to evaluate the structure of the adhesive surface. Data were statistically analyzed using one-way ANOVA and LSD post hoc tests (α = 0.05).</p><p><strong>Results: </strong>A significant difference in μSBS was observed among the groups (P = 0.029). The highest μSBS (29.5 ± 9.25 MPa) was recorded in the group that was contaminated after primer application and subsequently decontaminated with KC prior to bonding, surpassing even the uncontaminated control group. Decontamination following contamination after polymerization also led to significantly improved μSBS (26.5 ± 10.78 MPa). Groups without any decontamination exhibited significantly lower μSBS. Predominantly cohesive (in composite resin) and mixed failure modes were observed in high-strength groups, while adhesive failures were more common in low-strength groups.</p><p><strong>Conclusion: </strong>KC significantly improved the μSBS of composite resin in saliva-contaminated dentin, particularly when applied after primer or post-polymerization contamination. These findings support the clinical use of KC as an effective decontamination protocol to maintain bonding performance under compromised isolation.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"28 ","pages":"1-10"},"PeriodicalIF":2.7,"publicationDate":"2026-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12887243/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"146145291","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of Etching Mode on the Dentin Bond Durability of Universal Adhesives. 蚀刻方式对通用胶粘剂牙本质黏结耐久性的影响。
IF 2.7
The journal of adhesive dentistry Pub Date : 2025-12-19 DOI: 10.3290/j.jad.c_2447
Sena Balaban, Hacer Deniz Arısu
{"title":"Effect of Etching Mode on the Dentin Bond Durability of Universal Adhesives.","authors":"Sena Balaban, Hacer Deniz Arısu","doi":"10.3290/j.jad.c_2447","DOIUrl":"10.3290/j.jad.c_2447","url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated the effects of etching mode, pH, and composition on the shear bond strength of three universal adhesives (UAs), in comparison with conventional adhesives.</p><p><strong>Materials and methods: </strong>Crowns from 110 extracted third molars were sectioned to obtain 220 dentin surfaces and allocated into 11 groups (n = 20) based on adhesive system (OptiBondFL, ClearfilSE Bond, All-Bond Universal, OptiBond Universal, G2-Bond Universal) and etching mode (etch-and-rinse [ER], self-etch [SE], selective dentin etching [SDE]). Each group was divided into pre- and post-aging sub-groups. Shear bond strength was tested at 24h and after 5,000 thermal cycles. The resin-dentin interface was examined using scanning electron microscopy (SEM). Data were analyzed using one-way ANOVA, LSD post-hoc and paired-sample t-tests (α = 0.05).</p><p><strong>Results: </strong>All-Bond Universal exhibited the highest bond strength across all modes, while OptiBond Universal showed the lowest. No significant difference was observed between ER and SE modes for most UAs, except G2-Bond Universal. SDE did not result in significantly higher bond strength compared to SE or ER in any group. After aging, G2-Bond Universal in SE mode exhibited the highest bond strength.</p><p><strong>Conclusion: </strong>Bond strength was influenced by etching mode, pH, and composition of the adhesive. UAs performed comparably to the gold-standard SE adhesive in SE mode; however, their performance in ER mode varied depending on their composition and pH.</p><p><strong>Clinical relevance: </strong>To ensure predictable clinical outcomes, clinicians should recognize that UAs do not perform uniformly. Selecting both the adhesive and etching mode according to the adhesive's composition may enhance long-term bonding success.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"27 ","pages":"297-305"},"PeriodicalIF":2.7,"publicationDate":"2025-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12720019/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145795772","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Urethane Tetramethacrylate Monomers and Nano-Fillers Enhance Dentin Bond Strength of a One-Step Universal Adhesive. 聚氨酯四甲基丙烯酸酯单体和纳米填料增强一步通用胶粘剂的牙本质结合强度。
IF 2.7
The journal of adhesive dentistry Pub Date : 2025-12-19 DOI: 10.3290/j.jad.c_2432
Yusuke Matsuki, Yumika Ida, Tomoki Iuchi, Wakana Oki, Kazuhide Yonekura, Yuta Utsumi, Masaomi Ikeda, Lorenzo Breschi, Keiichi Hosaka
{"title":"Urethane Tetramethacrylate Monomers and Nano-Fillers Enhance Dentin Bond Strength of a One-Step Universal Adhesive.","authors":"Yusuke Matsuki, Yumika Ida, Tomoki Iuchi, Wakana Oki, Kazuhide Yonekura, Yuta Utsumi, Masaomi Ikeda, Lorenzo Breschi, Keiichi Hosaka","doi":"10.3290/j.jad.c_2432","DOIUrl":"10.3290/j.jad.c_2432","url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated the effects of incorporating urethane tetramethacrylate (UTMA) monomers and inorganic nano-fillers on the bonding performance and mechanical properties of a next-generation one-step universal adhesive, Clearfil Universal Bond Quick 2 (UBQ2), with a focus on clarifying its improvements over the previous formulation.</p><p><strong>Materials and methods: </strong>Five adhesive systems were investigated: UBQ2, two experimental variants lacking either UTMA (UBQ2-U) or nano-fillers (UBQ2-F), the predecessor adhesive (Clearfil Universal Bond Quick, UBQ), and a gold-standard two-step self-etch adhesive (Clearfil SE Bond 2, SE2). Microtensile bond strength (μTBS), bond layer thickness (L), ultimate tensile strength (UTS), and water sorption (Wsp) were evaluated.</p><p><strong>Results: </strong>UBQ2 demonstrated significantly higher UTS and lower Wsp than UBQ2-U (P 0.001 and P = 0.03, respectively), indicating enhanced mechanical resilience and hydrolytic stability due to the presence of UTMA. Compared to UBQ, UBQ2 showed improved mechanical properties while maintaining comparable μTBS. The absence of nano-fillers (UBQ2-F) significantly reduced μTBS (P 0.05), confirming their critical role in bonding performance. Despite forming a thinner adhesive layer, UBQ2 achieved dentin bond strength comparable to SE2.</p><p><strong>Conclusion: </strong>By combining UTMA and nano-fillers, UBQ2 has improved wettability compared to conventional products, while also providing high bonding performance and mechanical properties with a one-step application. These findings support the development of universal adhesives through simplified clinical protocols and improved material properties.</p><p><strong>Clinical relevance: </strong>This study demonstrates that incorporating nano-fillers and UTMA into a one-step universal adhesive (UBQ2) enhances mechanical strength, reduces water sorption, and maintains high dentin bond strength. Clinically, UBQ2 offers a simplified yet reliable bonding performance comparable to SE2.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"27 ","pages":"287-295"},"PeriodicalIF":2.7,"publicationDate":"2025-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12720021/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145784159","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Battle of the Bonds: Training's Impact on Dental Adhesive Use in Undergraduate and Continuing Education. 债券之战:培训对本科和继续教育中牙科粘合剂使用的影响。
IF 2.7
The journal of adhesive dentistry Pub Date : 2025-12-17 DOI: 10.3290/j.jad.c_2433
Sophie Gosselin, Lenny Dahan, Frederic Raux, Stephane Le-Goff, Sarah Abdel-Gawad, Helene Gouze, Maria-Antonietta D'Agostino, Timothy Fasham, Elisabeth Dursun, Emmanuel Bourdageau, Yasmine Smail, Jean-Pierre Attal, Mathieu A Derbanne, Philippe François
{"title":"Battle of the Bonds: Training's Impact on Dental Adhesive Use in Undergraduate and Continuing Education.","authors":"Sophie Gosselin, Lenny Dahan, Frederic Raux, Stephane Le-Goff, Sarah Abdel-Gawad, Helene Gouze, Maria-Antonietta D'Agostino, Timothy Fasham, Elisabeth Dursun, Emmanuel Bourdageau, Yasmine Smail, Jean-Pierre Attal, Mathieu A Derbanne, Philippe François","doi":"10.3290/j.jad.c_2433","DOIUrl":"10.3290/j.jad.c_2433","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate whether single-day, gamified training (called 'Battle of the Bonds') improves operators' immediate macro dentin shear bond strength (SBS) values and perceived learning in undergraduate and continuing dental education about dental adhesives, composite resin, and light-curing units.</p><p><strong>Materials and methods: </strong>In July 2025, 14 dentists and 21 final-year students performed four macro-SBS tests before and eleven after lectures on adhesive systems, composite selection, and light-curing. SBS was measured on human dentin for each participant's routine adhesive and representatives of all actual adhesive/generation families (from three-step etch-and-rinse to universal adhesives). Post-course satisfaction was measured using a 13-item Likert questionnaire (ranging from 1 to 5). Paired and independent t-tests were used to compare the SBS (α = 0.05).</p><p><strong>Results: </strong>The baseline SBS with the participants' own adhesive was similar between the dentists and the students (12.5 ± 6.4 MPa vs 13.1 ± 6.6 MPa, P = 0.68). After training, the mean SBS with the participants' own adhesive significantly increased to 18.5 ± 6.3 MPa for the dentists (+67%) and to 17.3 ± 6.0 MPa for the students (+27%) (both P 0.05). Satisfaction with training and perceived knowledge gains were very high (4.9 ± 0.5 for dentists and 4.9 ± 0.3 for students).</p><p><strong>Conclusions: </strong>A single-day, competition-based curriculum that couples concise lectures with hands-on SBS testing yields rapid, clinically meaningful improvements and strong engagement across predoctoral and practitioner audiences. This experiential format may help standardize technique-sensitive restorative skills in dental education.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"27 ","pages":"277-286"},"PeriodicalIF":2.7,"publicationDate":"2025-12-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12712387/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145769856","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of Bioactive, Inorganic, and Organic Fillers on Basic Properties of 4-META/MMA-TBB Resin as Restorative Materials for Root Caries. 生物活性、无机和有机填料对4-META/MMA-TBB树脂根龋修复材料基本性能的影响
IF 2.7
The journal of adhesive dentistry Pub Date : 2025-12-16 DOI: 10.3290/j.jad.c_2428
Miho Kikuta, Masanao Inokoshi, Rena Takahashi, Mao Yamamoto, Hiraku Onuma, Kumiko Yoshihara, Manabu Kanazawa
{"title":"Influence of Bioactive, Inorganic, and Organic Fillers on Basic Properties of 4-META/MMA-TBB Resin as Restorative Materials for Root Caries.","authors":"Miho Kikuta, Masanao Inokoshi, Rena Takahashi, Mao Yamamoto, Hiraku Onuma, Kumiko Yoshihara, Manabu Kanazawa","doi":"10.3290/j.jad.c_2428","DOIUrl":"10.3290/j.jad.c_2428","url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the effects of bioactive, inorganic, and organic fillers on the curing time, mechanical properties, mineralization ability, and shear bond strength to dentin of 4-methacryloxyethyl trimellitate anhydride/methyl methacrylate-tri-n-butylborane (4-META/MMA-TBB) resin-based restorative materials.</p><p><strong>Materials and methods: </strong>Experimental resins were prepared by incorporating 3 wt% organic composite filler, bioactive glass, or aluminosilicate glass into 4-META/MMA-TBB resin. A commercial organic-filler-containing 4-META/MMA-TBB resin (Bondfill SB Plus (BSP)) was also tested for comparison. The curing time, three-point flexural strength, and shear bond strength to root dentin were measured and statistically analyzed with a significance level of α = 0.05. The mineralization ability of groups containing bioactive glass was evaluated based on the formation of hydroxyapatite in simulated body fluid.</p><p><strong>Results: </strong>The bioactive glass group exhibited prolonged curing times and reduced flexural strengths compared to BSP. Bioactive glass induced slight mineralization. Organic composite filler reduced the curing time and significantly increased the shear bond strength to dentin. After thermal cycling, the organic composite filler groups retained higher bond strengths than the other groups.</p><p><strong>Conclusion: </strong>Incorporating organic composite fillers into 4-META/MMA-TBB resin may improve clinical handling by reducing the curing time while maintaining or enhancing the bond strength to dentin, suggesting their suitability for restorative applications, particularly in moisture-compromised environments.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"27 ","pages":"267-275"},"PeriodicalIF":2.7,"publicationDate":"2025-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12709080/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145764861","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Impact of Various Moisture Control Methods on Intraoral Humidity. 不同湿度控制方法对口腔内湿度的影响。
IF 2.7
The journal of adhesive dentistry Pub Date : 2025-12-11 DOI: 10.3290/j.jad.c_2398
Takashi Washino, Masaomi Ikeda, Michael F Burrow, Toru Nikaido
{"title":"Impact of Various Moisture Control Methods on Intraoral Humidity.","authors":"Takashi Washino, Masaomi Ikeda, Michael F Burrow, Toru Nikaido","doi":"10.3290/j.jad.c_2398","DOIUrl":"10.3290/j.jad.c_2398","url":null,"abstract":"<p><strong>Purpose: </strong>This prospective crossover clinical study evaluated the effectiveness of different moisture control methods on intraoral humidity and examined the influence of external environmental humidity.</p><p><strong>Materials and methods: </strong>Forty adult participants (31 females, 9 males; mean age 36.6 ± 11.3 years) were enrolled. Intraoral relative humidity was measured above anterior and posterior teeth under four randomized conditions: control (mouth breathing), rubber dam isolation, vacuum-assisted isolation (ZOO), and saliva ejector. External humidity was recorded simultaneously and categorized as high (≥60%) or low (60%).</p><p><strong>Results: </strong>Both rubber dam isolation and vacuum-assisted isolation significantly reduced intraoral humidity compared with the saliva ejector and control. Under low external humidity, rubber dam and vacuum-assisted isolation achieved the lowest intraoral humidity (all P 0.001). Under high external humidity, all methods reduced humidity compared with control, but vacuum-assisted isolation remained significantly more effective than the rubber dam and saliva ejector. External humidity showed a strong correlation with intraoral humidity in the rubber dam group (ρ up to 0.77, P 0.001).</p><p><strong>Conclusion: </strong>Moisture control methods differ in their ability to reduce intraoral humidity, with rubber dam and vacuum-assisted isolation providing the most effective reduction. However, high external humidity significantly increases intraoral humidity regardless of the isolation method, indicating that clinicians should consider both the isolation strategy and environmental conditions when aiming to minimize intraoral humidity.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"27 ","pages":"261-266"},"PeriodicalIF":2.7,"publicationDate":"2025-12-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12703896/pdf/","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"145727793","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书