Perspectives in science最新文献

筛选
英文 中文
Passive etched track detectors application in outdoor radon monitoring 被动蚀刻轨迹探测器在室外氡监测中的应用
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100416
J.M. Wasikiewicz, Z. Daraktchieva, C.B. Howarth
{"title":"Passive etched track detectors application in outdoor radon monitoring","authors":"J.M. Wasikiewicz,&nbsp;Z. Daraktchieva,&nbsp;C.B. Howarth","doi":"10.1016/j.pisc.2019.100416","DOIUrl":"10.1016/j.pisc.2019.100416","url":null,"abstract":"<div><p>Over 18 months long measurements of outdoor radon in three areas (a total of 69 locations) in England were conducted between years 2015 and 2017 using PADC based passive nuclear track detectors. Special measurement equipment and protocols to counteract unfavourable weather conditions have been designed, developed and optimised for the low level radon concentration.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100416"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100416","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44574524","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Evaluation of radiation risks during CT brain procedures for adults 成人CT脑部手术中辐射风险的评估
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100407
Slimane Semghouli , Bouchra Amaoui , Abdennasser El Kharras , Khalid Bouykhlaf , Oum Keltoum Hakam , Abdelmajid Choukri
{"title":"Evaluation of radiation risks during CT brain procedures for adults","authors":"Slimane Semghouli ,&nbsp;Bouchra Amaoui ,&nbsp;Abdennasser El Kharras ,&nbsp;Khalid Bouykhlaf ,&nbsp;Oum Keltoum Hakam ,&nbsp;Abdelmajid Choukri","doi":"10.1016/j.pisc.2019.100407","DOIUrl":"10.1016/j.pisc.2019.100407","url":null,"abstract":"<div><p>The purpose of this study is to evaluate the patients’ radiation dose in three different modalities of CT scanners (64, 16 and 2 slices) and the biological effects during CT brain examinations.</p><p>A total of 60 patients were examined in three different hospitals in Morocco. The data were collected from CT Brain examinations at of 20 CT scans per hospital. For each examination, we have reported CT acquisition parameters including the number of series, use of contrast medium; tube kV, tube current and rotation time, slice thickness as well as the displayed CT dose index (CTDI<sub>vol</sub>) and the Dose Length Product (DLP). Cancer and biological heredity risks were estimated using the International Commission on Radiological Protection (ICRP) conversion factors.</p><p>The average dose values for CT brain for 2 slices was 305<!--> <!-->±<!--> <!-->112<!--> <!-->mGy.cm. The mean dose value for 16 slices was 716<!--> <!-->±<!--> <!-->179<!--> <!-->mGy.cm, while the average dose for 64 slices was 1136<!--> <!-->±<!--> <!-->708<!--> <!-->mGy.cm. The patient cancer risks per procedure ranged between 4 and 13 per 10<sup>5</sup> CT procedures. This risk is 4, 8 and 13 per 10<sup>5</sup> CT procedures for 2 slices, 16 slices and 64 slices respectively. The patient heredity risks varied between 1 and 5 per million CT procedures. It is 1, 3 and 5 for 2 slices, 16 slices and 64 slices respectively.</p><p>Dual slice scanner delivered the least effective dose while 16 and 64 slice scanners delivered the highest effective dose. The dose values of this study were comparable to the international reference levels of CT examination. CT dose optimization protocol is not implemented in the Moroccan hospitals. These values could be used as our hospital's Dose Reference Levels (DRL) until a more detailed study survey can be conducted in Morocco for the establishment of the country's reference levels.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100407"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100407","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46327105","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
210Po as a source of natural radioactivity in cigarettes distributed in the Philippines 在菲律宾销售的香烟中,po是天然放射性的来源
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100400
Kazuki Iwaoka , Eliza B. Enriquez , Kazuaki Yajima , Masahiro Hosoda , Shinji Tokonami , Hidenori Yonehara , Teofilo Y. Garcia , Reiko Kanda
{"title":"210Po as a source of natural radioactivity in cigarettes distributed in the Philippines","authors":"Kazuki Iwaoka ,&nbsp;Eliza B. Enriquez ,&nbsp;Kazuaki Yajima ,&nbsp;Masahiro Hosoda ,&nbsp;Shinji Tokonami ,&nbsp;Hidenori Yonehara ,&nbsp;Teofilo Y. Garcia ,&nbsp;Reiko Kanda","doi":"10.1016/j.pisc.2019.100400","DOIUrl":"10.1016/j.pisc.2019.100400","url":null,"abstract":"<div><p>The natural radioactive nuclides especially <sup>210</sup>Po, are volatilized at the temperature (600–800<!--> <!-->°C) of a burning cigarette and are taken into the human body. Therefore, analysis of natural radioactivity of <sup>210</sup>Po in cigarettes and the effective dose to smokers should be evaluated. The activity concentration of <sup>210</sup>Po in sixteen brands of Philippine cigarettes was measured by alpha spectrometry, and estimation of effective dose of <sup>210</sup>Po to smokers was performed. The activity concentration of <sup>210</sup>Po in cigarettes distributed in the Philippines ranged from 5.5 to 17.8<!--> <!-->mBq/cigarette and the mean value of their activity concentrations was 12.0<!--> <!-->mBq/cigarette. The mean value of annual effective doses of <sup>210</sup>Po to smokers obtained from these activity concentrations was 0.021<!--> <!-->mSv/y, which was lower than the reference level (1–20<!--> <!-->mSv/y) for existing situation in ICRP Publication 103.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100400"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100400","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42995376","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Dosimetric characterization of MgB4O7:Ce,Li as an optically stimulated dosimeter for photon beam radiotherapy MgB4O7:Ce,Li作为光子束放射治疗光刺激剂量计的剂量学特性
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100397
Luiza Freire de Souza , Divanizia N. Souza , Gerardo B. Rivera , Rogerio M. Vidal , Linda V.E. Caldas
{"title":"Dosimetric characterization of MgB4O7:Ce,Li as an optically stimulated dosimeter for photon beam radiotherapy","authors":"Luiza Freire de Souza ,&nbsp;Divanizia N. Souza ,&nbsp;Gerardo B. Rivera ,&nbsp;Rogerio M. Vidal ,&nbsp;Linda V.E. Caldas","doi":"10.1016/j.pisc.2019.100397","DOIUrl":"10.1016/j.pisc.2019.100397","url":null,"abstract":"<div><p>Currently there is a growing interest in the development of optically stimulated luminescence (OSL) dosimeters that may be useful for assessing the neutron flux contribution on the doses in radiotherapy due to neutrons produced in the interaction of megavoltage photon beams. In this work, OSL responses of MgB<sub>4</sub>O<sub>7</sub>:Ce,Li with <sup>11</sup>B are presented for some photon beams, including 6<!--> <!-->MV and 10<!--> <!-->MV. For 10<!--> <!-->MV, the behavior of the phosphor containing <sup>10</sup>B was also evaluated. The material with <sup>10</sup>B exhibited an OSL response slightly more intense than that with <sup>11</sup>B, indicating a possible application of this new material for dosimetry in photon radiotherapy.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100397"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100397","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43433733","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Laser microdissection system applied in improving FT-TIMS technique 激光显微解剖系统在FT-TIMS技术改进中的应用
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100395
Yan Chen, Chang-Kun Xu, Yong-Gang Zhao, Shi-Lun Guo, Li-Li Li, Zhi-Yuan Chang, Guo-Rong Liu
{"title":"Laser microdissection system applied in improving FT-TIMS technique","authors":"Yan Chen,&nbsp;Chang-Kun Xu,&nbsp;Yong-Gang Zhao,&nbsp;Shi-Lun Guo,&nbsp;Li-Li Li,&nbsp;Zhi-Yuan Chang,&nbsp;Guo-Rong Liu","doi":"10.1016/j.pisc.2019.100395","DOIUrl":"10.1016/j.pisc.2019.100395","url":null,"abstract":"<div><p>A laser microdissection system was used for isolating fission track stars to improve the cutting efficiency in the FT-TIMS particle analytical technique. The background interference of track detectors to determine isotopic ratios was studied. Several swipe samples were successfully measured for particle analysis by FT-TIMS. The results show that the laser microdissection system could effectively improve the ability of FT-TIMS particle analytical technique.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100395"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100395","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44448905","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Characterization and qualification of a CRNA eye dosimeter CRNA眼剂量计的特性和鉴定
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100402
K. Larabi-Harfouche , F. Dari , A. Herrati , G. Medkour-Boushaki , Z. Lounis-Mokrani
{"title":"Characterization and qualification of a CRNA eye dosimeter","authors":"K. Larabi-Harfouche ,&nbsp;F. Dari ,&nbsp;A. Herrati ,&nbsp;G. Medkour-Boushaki ,&nbsp;Z. Lounis-Mokrani","doi":"10.1016/j.pisc.2019.100402","DOIUrl":"10.1016/j.pisc.2019.100402","url":null,"abstract":"<div><p>The aim of this work is to study the calibration methodology of a new eye dosimeter, developed by Dosimetry Laboratory of the Nuclear Research Center of Algiers, using TLD-700 thermoluminescent detectors (LiF: Mg, Ti). Qualification and type test of this dosimeter have been performed in terms of operational quantity Hp(3) at Secondary Standard Dosimetry Laboratory (SSDL) using the cylindrical phantom according to ISO 12794, ORAMED 2012 and IEC 62387, 2012. Furthermore, two dosimeter holders have been tested for two positions (frontal and lateral) in order to determine the “best dosimeter position” which allows good estimation of dose received by lens.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100402"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100402","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45134392","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
A new method for determination solid state nuclear track by the change of the specific heat capacity 用比热容变化确定固态核轨道的新方法
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100403
Lu Jin , Yang Tongsuo , Li YiYi guo , Shi Yongqian , Zhang Jianxiang , Hua Xiao , Wang Yongcang , Xin duqiang , Zhang Yongbao
{"title":"A new method for determination solid state nuclear track by the change of the specific heat capacity","authors":"Lu Jin ,&nbsp;Yang Tongsuo ,&nbsp;Li YiYi guo ,&nbsp;Shi Yongqian ,&nbsp;Zhang Jianxiang ,&nbsp;Hua Xiao ,&nbsp;Wang Yongcang ,&nbsp;Xin duqiang ,&nbsp;Zhang Yongbao","doi":"10.1016/j.pisc.2019.100403","DOIUrl":"10.1016/j.pisc.2019.100403","url":null,"abstract":"<div><p>A new measurement method for determination Solid State nuclear track by the change of the specific heat capacity is proposed. The feasibility of the method is discussed in both theory and practice, to determine the solid state nuclear tracks by specific heat capacity when annealing. In the research, the change of the specific heat capacity is related with nuclear track numbers after annealing and it could be measured and verified time after time. The theory and experiments are introduced with details. The potential applications of this method in the future are discussed, such as determination of the neutron flux at high lever reactors and geologic age of the geological samples.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100403"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100403","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49315541","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Annual effective dose and excess life time cancer risk assessment from tobacco plants 烟草植物的年有效剂量和超长寿命癌症风险评估
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100394
D. Boumala , A. Belafrites , A. Tedjani , Ch. Mavon , J.-E. Groetz
{"title":"Annual effective dose and excess life time cancer risk assessment from tobacco plants","authors":"D. Boumala ,&nbsp;A. Belafrites ,&nbsp;A. Tedjani ,&nbsp;Ch. Mavon ,&nbsp;J.-E. Groetz","doi":"10.1016/j.pisc.2019.100394","DOIUrl":"10.1016/j.pisc.2019.100394","url":null,"abstract":"<div><p>Cigarette smoking is one of the pathways that might cause radiation exposure due to the presence of radioactive elements in tobacco leaves used in the manufacture of cigarettes. From the health point of view, the knowledge of radioactivity content of the various radionuclides in tobacco leaves and their derivative products is important to assess the radiological effects associated with tobacco smoking for smokers. In this work, naturally occurring radionuclides <sup>226</sup>Ra, <sup>232</sup>Th and <sup>40</sup>K and man-made <sup>137</sup>Cs were measured in tobacco using gamma-ray spectrometry. Results show that the average concentrations of <sup>226</sup>Ra, <sup>232</sup>Th and <sup>40</sup>K vary from 4.30<!--> <!-->±<!--> <!-->0.2 to 11.85<!--> <!-->±<!--> <!-->0.7 (average 8.17), 1.35<!--> <!-->±<!--> <!-->0.1 to 16.12<!--> <!-->±<!--> <!-->0.9 (average 6.08), and 565.6<!--> <!-->±<!--> <!-->15.5 to 1235.81<!--> <!-->±<!--> <!-->35 (average 908.09)<!--> <!-->Bq<!--> <!-->kg<sup>−1</sup>, respectively. <sup>137</sup>Cs activity concentrations were ranged from 0.15<!--> <!-->±<!--> <!-->0.01 to 0.67<!--> <!-->±<!--> <!-->0.9 (average 0.44)<!--> <!-->Bq<!--> <!-->kg<sup>−1</sup>. The most important radiological parameters, including radium equivalent (Ra<sub>eq</sub>), total annual effective dose (AED) and excess lifetime cancer risk (ELCR) were calculated. For smokers, the total AED resulting from activity concentrations of <sup>226</sup>Ra, <sup>232</sup>Th and <sup>40</sup>K in tobacco samples ranged from 0.44 to 2.29 (average 1.39)<!--> <!-->mSv<!--> <!-->y<sup>−1</sup>, while of <sup>137</sup>Cs varied from 0.01 to 0.04 (average 0.025)<!--> <!-->μSv<!--> <!-->y<sup>−1</sup> and so very little is contributing to the total dose due to inhalation to smokers. ELCR was higher than the world's average of 1.45<!--> <!-->×<!--> <!-->10<sup>−3</sup> for tobacco and coal samples. The excess lifetime cancer risk ranged from 1.55<!--> <!-->×<!--> <!-->10<sup>−3</sup> to 8.01<!--> <!-->×<!--> <!-->10<sup>−3</sup> with an average value of 4.88<!--> <!-->×<!--> <!-->10<sup>−3</sup> for all tobacco samples under investigation.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100394"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100394","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44573093","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
The radionuclide distribution onto different mineral phases of the rocks of the exocontact zone of Nizhnekansky granitoid massif 尼日涅坎斯基花岗质地块外接触带不同矿物相岩石中的放射性核素分布
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100406
Anastasiya A. Rodionova , Vladimir G. Petrov , Irina E. Vlasova , Stepan N. Kalmykov , Vladislav A. Petrov , Valery V. Poluektov , Jörg Hammer
{"title":"The radionuclide distribution onto different mineral phases of the rocks of the exocontact zone of Nizhnekansky granitoid massif","authors":"Anastasiya A. Rodionova ,&nbsp;Vladimir G. Petrov ,&nbsp;Irina E. Vlasova ,&nbsp;Stepan N. Kalmykov ,&nbsp;Vladislav A. Petrov ,&nbsp;Valery V. Poluektov ,&nbsp;Jörg Hammer","doi":"10.1016/j.pisc.2019.100406","DOIUrl":"10.1016/j.pisc.2019.100406","url":null,"abstract":"<div><p>The sorption experiments with the five rock samples drilled in the deep-well in the exocontact zone of Nizhnekansky granitoid massif (EZNGM) in the range of depth 166–476<!--> <!-->m were carried out. The distribution of radium was studied. The radiograms of radionuclide sorption were obtained by digital autoradiography. Heterogeneous sorption of radium was demonstrated by digital radiography and phases with higher sorption ability were revealed. The technique for the treatment of radiograms with the help of ImageJ program for obtaining quantitative parameters of radionuclides distribution in the granite-gneiss rock samples was developed. Relative sorption efficiency of different mineral phases of the rock samples of Eniseysky area (EZNGM) toward radium is presented in the paper.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100406"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100406","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42642362","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
FOOT: a new experiment to measure nuclear fragmentation at intermediate energies FOOT:一项测量中等能量下核碎片的新实验
Perspectives in science Pub Date : 2019-09-01 DOI: 10.1016/j.pisc.2019.100415
S.M. Valle , A. Alexandrov , G. Ambrosi , S. Argirò , G. Battistoni , N. Belcari , S. Biondi , M.G. Bisogni , G. Bruni , S. Brambilla , N. Camarlinghi , P. Cerello , E. Ciarrocchi , A. Clozza , G. De Lellis , A. Di Crescenzo , M. Durante , M. Emde , R. Faccini , V. Ferrero , A. Zoccoli
{"title":"FOOT: a new experiment to measure nuclear fragmentation at intermediate energies","authors":"S.M. Valle ,&nbsp;A. Alexandrov ,&nbsp;G. Ambrosi ,&nbsp;S. Argirò ,&nbsp;G. Battistoni ,&nbsp;N. Belcari ,&nbsp;S. Biondi ,&nbsp;M.G. Bisogni ,&nbsp;G. Bruni ,&nbsp;S. Brambilla ,&nbsp;N. Camarlinghi ,&nbsp;P. Cerello ,&nbsp;E. Ciarrocchi ,&nbsp;A. Clozza ,&nbsp;G. De Lellis ,&nbsp;A. Di Crescenzo ,&nbsp;M. Durante ,&nbsp;M. Emde ,&nbsp;R. Faccini ,&nbsp;V. Ferrero ,&nbsp;A. Zoccoli","doi":"10.1016/j.pisc.2019.100415","DOIUrl":"10.1016/j.pisc.2019.100415","url":null,"abstract":"<div><p>Charged particle therapy exploits proton or <sup>12</sup>C beams to treat deep-seated solid tumors. Due to the advantageous characteristics of charged particles energy deposition in matter, the maximum of the dose is released to the tumor at the end of the beam range, in the Bragg peak region. However, the beam nuclear interactions with the patient tissues induces fragmentation both of projectile and target nuclei and needs to be carefully taken into account. In proton treatments, target fragmentation produces low energy, short range fragments along all the beam range, which deposit a non negligible dose in the entry channel. In <sup>12</sup>C treatments the main concern is represented by long range fragments due to beam fragmentation that release their dose in the healthy tissues beyond the tumor. The FOOT experiment (FragmentatiOn Of Target) of INFN is designed to study these processes, in order to improve the nuclear fragmentation description in next generation Treatment Planning Systems and the treatment plans quality. Target (<sup>16</sup>O and <sup>12</sup>C nuclei) fragmentation induced by –proton beams at therapeutic energies will be studied via an inverse kinematic approach, where <sup>16</sup>O and <sup>12</sup>C therapeutic beams impinge on graphite and hydrocarbon targets to provide the nuclear fragmentation cross section on hydrogen. Projectile fragmentation of <sup>16</sup>O and <sup>12</sup>C beams will be explored as well. The FOOT detector includes a magnetic spectrometer for the fragments momentum measurement, a plastic scintillator for ΔE and time of flight measurements and a crystal calorimeter to measure the fragments kinetic energy. These measurements will be combined in order to make an accurate fragment charge and isotopic identification.</p></div>","PeriodicalId":92112,"journal":{"name":"Perspectives in science","volume":"12 ","pages":"Article 100415"},"PeriodicalIF":0.0,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pisc.2019.100415","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43044817","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信