Neonatal intensive care : the journal of perinatology-neonatology最新文献

筛选
英文 中文
Synchronous and patient-triggered ventilation in newborns. 新生儿同步和患者触发通气。
G Bernstein
{"title":"Synchronous and patient-triggered ventilation in newborns.","authors":"G Bernstein","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 5","pages":"54-8, 66"},"PeriodicalIF":0.0,"publicationDate":"1993-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21018767","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
HFV: applied technology, saving both lives and costs. HFV:应用技术,节省生命和成本。
T Bachman, G Lassen
{"title":"HFV: applied technology, saving both lives and costs.","authors":"T Bachman, G Lassen","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 5","pages":"34-8"},"PeriodicalIF":0.0,"publicationDate":"1993-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21018762","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Is fetal heart rate monitoring during labor and delivery justified? 在产程和分娩期间监测胎儿心率是否合理?
B Petrikovsky
{"title":"Is fetal heart rate monitoring during labor and delivery justified?","authors":"B Petrikovsky","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 4","pages":"19-20"},"PeriodicalIF":0.0,"publicationDate":"1993-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020598","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
New monitoring strategies in respiratory care of pre-term infants. 早产儿呼吸照护新监测策略。
R Sahni, J T Wung
{"title":"New monitoring strategies in respiratory care of pre-term infants.","authors":"R Sahni, J T Wung","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 4","pages":"21-5"},"PeriodicalIF":0.0,"publicationDate":"1993-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020600","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The clinical utility of serum creatinine measurement vs calculated glomerular filtration rate in the assessment of renal function in the premature infant. 血清肌酐测定与计算肾小球滤过率在早产儿肾功能评估中的临床应用。
A L Alkalay, S J Farber, P R Ordonez, J J Pomerance
{"title":"The clinical utility of serum creatinine measurement vs calculated glomerular filtration rate in the assessment of renal function in the premature infant.","authors":"A L Alkalay,&nbsp;S J Farber,&nbsp;P R Ordonez,&nbsp;J J Pomerance","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>The ability to assess the glomerular filtration rate (GFR) without the necessity of collecting urine in premature infants would be of significant clinical benefit. In 1986, the modified Schwartz formula (MSF = 0.33 x length (cm)/plasma creatinine (mg/dL)) was developed. In the MSF, GFR was estimated in premature infants during the first post-natal year. The goal of the present study was to test the applicability of the MSF in premature infants during the neonatal period and to evaluate the clinical use of serum creatinine (Cr) as a predictor of GFR. In 42 premature infants of mean (+/-SD) birthweight 1506.6 (+/-388.8) g, gestational age 31.3 (+/-1.7) wks and post-natal age 14.7 (+/-8.3) d, the correlation between GFR, estimated by endogenous creatinine clearance (ECrC), was compared with the serum Cr and with GFR estimated by the MSF. The correlation coefficient between ECrC and serum Cr was 0.6789 and between estimated GFR derived from ECrC and MSF, 0.4657. In premature infants during the neonatal period, serum Cr has a better correlation with GFR than with MSF. When serum Cr is less than 0.9 mg/dL, the 95% confidence interval suggests that at least 89% of the infants can be expected to have an ECrC within the normal range.</p>","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 4","pages":"37-9"},"PeriodicalIF":0.0,"publicationDate":"1993-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020609","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A comparison of infusion devices at 1 ml/hr. 1 ml/hr输液器的比较。
B R Wood, K Huddleston, P Kolm
{"title":"A comparison of infusion devices at 1 ml/hr.","authors":"B R Wood,&nbsp;K Huddleston,&nbsp;P Kolm","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Delivery of medications by some infusion devices is irregular. This study investigated instantaneous flow in several infusion devices set at a rate of 1 ml/hr. The following devices were tested: Infusion Pumps: IMED 956A, IVAC 570, IVION \"Kids Pump.\" Syringe Pumps: Medfusion, Baxter, Baxter OR. Tests were performed using a Bio-Tek Infusion Device Analyzer (Model IDA-1). Instantaneous flow rate was defined as Q1/T1 where: Q=sample volume and T=time required to deliver sample volume. The infusion devices were received directly from their respective manufacturers and had not seen clinical service before testing. The units were fully charged and were tested while on AC power. The tests were conducted by the authors, using standard infusion sets and commercially prepared 5% dextrose and 0.45% sodium chloride solution. Each pump was tested for several hours and multiple trials were performed on each pump. The infusion pumps, IMED, IVION, and IVAC all demonstrated deviations from the desired flow rate. The IVAC pump had a greater fluctuation in flow from the set value of 1 ml/hr (p less than 0.02). Variances from mean +/- standard error for each device are shown in parenthesis. IMED 965A (0.005+/-0.014), IVION Kid's Pump (0.002+/-0.009), IVAC 570 (0.001+/-0.006). The Baxter syringe pump (0.002+/-0.009) also had a wide variance in flow. The Baxter OR (0.001+/-0.005) and the Medfusion (0.001+/-0.008) syringe pumps maintained the most consistent flow and showed less variance than the other devices tested.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 3","pages":"20-2"},"PeriodicalIF":0.0,"publicationDate":"1993-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020373","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Prolonged IV dwell in neonates. 新生儿静脉留置时间延长。
G Rhodes-Ryan
{"title":"Prolonged IV dwell in neonates.","authors":"G Rhodes-Ryan","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 3","pages":"44-5"},"PeriodicalIF":0.0,"publicationDate":"1993-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020377","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Central monitoring systems for the NICU. Review of a 2-year experience. 新生儿重症监护室中央监控系统。2年工作经验回顾。
J A Adams, I A Zabaleta
{"title":"Central monitoring systems for the NICU. Review of a 2-year experience.","authors":"J A Adams,&nbsp;I A Zabaleta","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 3","pages":"32-4"},"PeriodicalIF":0.0,"publicationDate":"1993-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020374","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Intravascular oxygen monitoring: a perspective from the bedside. 血管内氧监测:从床边看问题。
C E McConnell
{"title":"Intravascular oxygen monitoring: a perspective from the bedside.","authors":"C E McConnell","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 2","pages":"44-6"},"PeriodicalIF":0.0,"publicationDate":"1993-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020104","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fetal umbilical blood sampling. 胎儿脐血取样。
B M Petrikovsky, V R Klein
{"title":"Fetal umbilical blood sampling.","authors":"B M Petrikovsky,&nbsp;V R Klein","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":80096,"journal":{"name":"Neonatal intensive care : the journal of perinatology-neonatology","volume":"6 2","pages":"20-1"},"PeriodicalIF":0.0,"publicationDate":"1993-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"21020105","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信