American journal of optometry and physiological optics最新文献

筛选
英文 中文
Lens-induced fixation disparity curves. 透镜引起的固定视差曲线。
American journal of optometry and physiological optics Pub Date : 1988-08-01 DOI: 10.1097/00006324-198808000-00003
B Wick, C Joubert
{"title":"Lens-induced fixation disparity curves.","authors":"B Wick,&nbsp;C Joubert","doi":"10.1097/00006324-198808000-00003","DOIUrl":"https://doi.org/10.1097/00006324-198808000-00003","url":null,"abstract":"<p><p>Change in fixation disparity was measured as lens sphere power was changed at distance and near on a young adult population. The results were graphed to yield a lens-induced fixation disparity curve. The lens curves found were grouped into four basic types (A through D). Two types (A and B) had increasing eso fixation disparity with increasing minus lens power. Type C had little change in fixation disparity with any change in lens power, whereas type D had an initial increase and then no further change with increasing minus power. In addition, approximately 74% of the 38-subject sample had different curve types at distance and near. Possible clinical uses of the lens-induced fixation disparity curve include the prescribing of near additions for pre-presbyopes based on measures of the binocular vergence response to various lens sphere combinations.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 8","pages":"606-12"},"PeriodicalIF":0.0,"publicationDate":"1988-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198808000-00003","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14308769","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Effect of reinforcement on infants' performance in a preferential looking acuity task. 强化对婴儿优先注视敏锐任务表现的影响。
American journal of optometry and physiological optics Pub Date : 1988-08-01 DOI: 10.1097/00006324-198808000-00008
B R Stephens, M S Banks
{"title":"Effect of reinforcement on infants' performance in a preferential looking acuity task.","authors":"B R Stephens,&nbsp;M S Banks","doi":"10.1097/00006324-198808000-00008","DOIUrl":"https://doi.org/10.1097/00006324-198808000-00008","url":null,"abstract":"<p><p>Two experiments examined the effect of reinforcement on infants' performance in a preferential looking acuity task. In experiment 1, performance of 3- and 5-month-old infants was assessed under three conditions. In one condition, reinforcement was contingent upon performance. In another, no reinforcement was provided. In the last condition, reinforcement was provided, but it was not contingent upon performance. Similar performance was observed in all three conditions. In experiment 2, 7-month-olds were tested in the first and second conditions. No differences in performance were observed between these two groups. Thus, the reinforcement used in preferential looking measurements does not appear to improve performance significantly for 3- to 7-month-old infants. Several interpretations of these results are presented. The most plausible is that performance under nonreinforced conditions is already nearly optimal, so the addition of reinforcement has little impact. General implications for estimates of infant visual sensitivity in the laboratory and clinic are discussed.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 8","pages":"637-43"},"PeriodicalIF":0.0,"publicationDate":"1988-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198808000-00008","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14308774","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
RGP lens binding. RGP镜片绑定。
E Kenyon
{"title":"RGP lens binding.","authors":"E Kenyon","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 8","pages":"686-7"},"PeriodicalIF":0.0,"publicationDate":"1988-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14307187","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Calculating refractive index. 计算折射率。
G Smith
{"title":"Calculating refractive index.","authors":"G Smith","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 8","pages":"674-80"},"PeriodicalIF":0.0,"publicationDate":"1988-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14307186","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fresnel vs. conventional prisms: their effects on the apparent fronto-parallel plane horopter. 菲涅耳与传统棱镜:它们对视前平行平面光学的影响。
S M Brunnett, M T Munson, D G Kirschen
{"title":"Fresnel vs. conventional prisms: their effects on the apparent fronto-parallel plane horopter.","authors":"S M Brunnett,&nbsp;M T Munson,&nbsp;D G Kirschen","doi":"","DOIUrl":"","url":null,"abstract":"<p><p>Among the inherent optical aberrations found in conventional crown glass or resin prisms is the property known as nonuniform relative magnification. Prisms, by definition, displace an image by a given amount. However, the final size of the image is nonuniform, being relatively larger toward the apex than toward the base of the prism. At present, reduction of the amount of nonuniform magnification is achieved by fabricating the prismatic correction on relatively steeper base curves (i.e., +9.00 D). This research deals with an attempt to reduce nonuniform magnification using Fresnel prisms. In this way, image displacement is created only by small prism apices, each of equal power and each producing identical image displacement resulting in a smaller degree of nonuniformity of image size. In this experiment, equal amounts of prism were fabricated on flat and steep base curves, using either conventional or Fresnel prism. The precise magnitude of the nonuniform relative magnification for each set of lenses was measured by a number of observers using the Apparent Fronto-Parallel Plane (AFPP) horopter apparatus. After statistical analysis using both an analysis of variance (ANOVA) and a matched pair t-test, there proved to be no significant reduction in the amount of nonuniform relative magnification when Fresnel prisms were used in place of conventional ground prisms. Furthermore, maximal reduction of this aberration appears to be effected only by fabricating such corrections on steep base curves. Relative magnification is more a function of the orientation of the base-apex meridian and the angle of incident light from an extended object than of effects of prism type or thickness.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 7","pages":"519-26"},"PeriodicalIF":0.0,"publicationDate":"1988-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14336843","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Rigid gas-permeable vs. hydrogel contact lenses for extended wear. 刚性透气性与水凝胶隐形眼镜的长时间佩戴。
American journal of optometry and physiological optics Pub Date : 1988-07-01 DOI: 10.1097/00006324-198807000-00003
D Fonn, B A Holden
{"title":"Rigid gas-permeable vs. hydrogel contact lenses for extended wear.","authors":"D Fonn,&nbsp;B A Holden","doi":"10.1097/00006324-198807000-00003","DOIUrl":"https://doi.org/10.1097/00006324-198807000-00003","url":null,"abstract":"<p><p>A clinical trial was conducted to compare the extended wear performance of rigid gas-permeable (RGP) contact lenses with that of soft lenses. Subjects were fitted with a RGP lens (Boston IV) in one eye and a soft lens (Bausch & Lomb \"O\" series) in the other eye, and wore them on an extended wear basis for up to 3 months. No subjects developed any acute adverse reactions in the RGP lens-wearing eye. After the initial adaptation period, subject acceptance of RGP extended wear in terms of vision and comfort was superior. The RGP lenses also induced less chronic hypoxic stress than hydrogel lenses of comparable Dk/L, as evidenced by the presence of epithelial microcysts. Several complications of RGP extended wear were observed including lens binding, blepharoptosis, transient pupil size increases, and corneal staining. As hypoxia-induced corneal changes, such as microcysts and striae, were observed in the RGP lens-wearing eyes, we consider that these particular RGP lenses do not have adequate oxygen transmissibility for successful long-term extended wear. However, if RGP lens materials of higher oxygen transmissibility and better designs can be attained, the potential of RGP extended wear would appear promising.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 7","pages":"536-44"},"PeriodicalIF":0.0,"publicationDate":"1988-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198807000-00003","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14192919","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 43
Visual field area in phakic, aphakic, and pseudophakic individuals. 失视症、失视症和伪失视症患者的视野面积。
American journal of optometry and physiological optics Pub Date : 1988-07-01 DOI: 10.1097/00006324-198807000-00011
L Lazarus, T D Williams
{"title":"Visual field area in phakic, aphakic, and pseudophakic individuals.","authors":"L Lazarus,&nbsp;T D Williams","doi":"10.1097/00006324-198807000-00011","DOIUrl":"https://doi.org/10.1097/00006324-198807000-00011","url":null,"abstract":"<p><p>Goldmann perimetry was done on 11 pseudophakic subjects and results were compared to those of age-matched phakic subjects and a third group of aphakic individuals who were wearing rigid gas permeable contact lenses. Testing showed that the I-3 and I-4 fields of the subjects who had had cataract surgery were generally constricted when compared to the normal phakic population. Possible explanations for this include media clarity not being as important a factor in determining field size as was previously thought, peripheral retinal changes, and implant material affecting contrast sensitivity.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 7","pages":"593-7"},"PeriodicalIF":0.0,"publicationDate":"1988-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198807000-00011","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14336708","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 8
Comparative investigations of progressive lenses. 渐进晶状体的比较研究。
American journal of optometry and physiological optics Pub Date : 1988-07-01 DOI: 10.1097/00006324-198807000-00007
H Diepes, A Tameling
{"title":"Comparative investigations of progressive lenses.","authors":"H Diepes,&nbsp;A Tameling","doi":"10.1097/00006324-198807000-00007","DOIUrl":"https://doi.org/10.1097/00006324-198807000-00007","url":null,"abstract":"<p><p>Different types of progressive addition lenses were compared with each other. It was our aim to measure all parameters in such a way that they were consistent with the normal wearing situation. The distribution of the spherical power and astigmatism was measured with a special focimeter. The induced distortion, which is important for patient acceptance, was determined by a photographic method. There are significant differences between the various types of progressive addition lenses. However, objective information is not sufficient to resolve the subjective question of patient acceptance.</p>","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 7","pages":"571-9"},"PeriodicalIF":0.0,"publicationDate":"1988-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00006324-198807000-00007","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14336705","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
AIDS Task Force policy statement. Section on Public Health and Occupational Vision of the American Academy of Optometry. 艾滋病特别工作组政策声明。美国视光学会公共卫生和职业视力部分。
{"title":"AIDS Task Force policy statement. Section on Public Health and Occupational Vision of the American Academy of Optometry.","authors":"","doi":"","DOIUrl":"","url":null,"abstract":"","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"65 7","pages":"599-601"},"PeriodicalIF":0.0,"publicationDate":"1988-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"14336710","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Fresnel vs. conventional prisms: their effects on the apparent fronto-parallel plane horopter. 菲涅耳与传统棱镜:它们对视前平行平面光学的影响。
American journal of optometry and physiological optics Pub Date : 1988-07-01 DOI: 10.1097/00006324-198807000-00001
S. M. Brunnett, M. T. Munson, D. Kirschen
{"title":"Fresnel vs. conventional prisms: their effects on the apparent fronto-parallel plane horopter.","authors":"S. M. Brunnett, M. T. Munson, D. Kirschen","doi":"10.1097/00006324-198807000-00001","DOIUrl":"https://doi.org/10.1097/00006324-198807000-00001","url":null,"abstract":"Among the inherent optical aberrations found in conventional crown glass or resin prisms is the property known as nonuniform relative magnification. Prisms, by definition, displace an image by a given amount. However, the final size of the image is nonuniform, being relatively larger toward the apex than toward the base of the prism. At present, reduction of the amount of nonuniform magnification is achieved by fabricating the prismatic correction on relatively steeper base curves (i.e., +9.00 D). This research deals with an attempt to reduce nonuniform magnification using Fresnel prisms. In this way, image displacement is created only by small prism apices, each of equal power and each producing identical image displacement resulting in a smaller degree of nonuniformity of image size. In this experiment, equal amounts of prism were fabricated on flat and steep base curves, using either conventional or Fresnel prism. The precise magnitude of the nonuniform relative magnification for each set of lenses was measured by a number of observers using the Apparent Fronto-Parallel Plane (AFPP) horopter apparatus. After statistical analysis using both an analysis of variance (ANOVA) and a matched pair t-test, there proved to be no significant reduction in the amount of nonuniform relative magnification when Fresnel prisms were used in place of conventional ground prisms. Furthermore, maximal reduction of this aberration appears to be effected only by fabricating such corrections on steep base curves. Relative magnification is more a function of the orientation of the base-apex meridian and the angle of incident light from an extended object than of effects of prism type or thickness.","PeriodicalId":7700,"journal":{"name":"American journal of optometry and physiological optics","volume":"9 1","pages":"519-26"},"PeriodicalIF":0.0,"publicationDate":"1988-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"82630961","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信