Biomechanics (Basel, Switzerland)最新文献

筛选
英文 中文
Modeling Joint Stiffness Change by Pelvic Tightening Based on Pelvic Alignment 基于骨盆对齐的骨盆紧固关节刚度变化建模
Biomechanics (Basel, Switzerland) Pub Date : 2022-05-22 DOI: 10.3390/biomechanics2020021
Michihiro Yoshida, Takayuki Tanaka, Yoshio Tsuchiya
{"title":"Modeling Joint Stiffness Change by Pelvic Tightening Based on Pelvic Alignment","authors":"Michihiro Yoshida, Takayuki Tanaka, Yoshio Tsuchiya","doi":"10.3390/biomechanics2020021","DOIUrl":"https://doi.org/10.3390/biomechanics2020021","url":null,"abstract":"This paper aims to develop a regression model that explains the relationship between changes in lumbar joint stiffness and pelvic alignment (posture or shape of the bones of the pelvis and lumbar spine) due to pelvic tightening. The proposed model is based on the hypothesis that lumbar joint stiffness increases with changes in pelvic alignment. The proposed model is based on experimentally measured stiffness values and pelvic alignment data sets. The stiffness of the lumbar joint was estimated by motion analysis using a motion-capture system. Ninety-six volunteers participated in the experiment to estimate stiffness values, and the validity of using lumbar joint stiffness as the output of the model was examined. The pelvic alignment was measured through X-ray images. Pelvic alignment was measured using radiographic images, and 25 volunteers participated. The Results section states that the amount of change in the posture of the sacrum relative to the pelvis and the curvature of the lumbar spine contributes to the change in lumbar joint stiffness. Future work will include FEM analysis to validate the overall hypothesis and the validity of applying the model to a group other than those who participated in the development of the model.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49597010","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Reliability of the Fluoroscopic Assessment of Load-Induced Glenohumeral Translation during a 30° Shoulder Abduction Test 在30°肩外展试验中负荷诱导的盂肱移位的透视评估的可靠性
Biomechanics (Basel, Switzerland) Pub Date : 2022-05-19 DOI: 10.3390/biomechanics2020020
Eleonora Croci, Marina Künzler, Sean Börlin, F. Eckers, C. Nüesch, D. Baumgartner, A. Müller, A. Mündermann
{"title":"Reliability of the Fluoroscopic Assessment of Load-Induced Glenohumeral Translation during a 30° Shoulder Abduction Test","authors":"Eleonora Croci, Marina Künzler, Sean Börlin, F. Eckers, C. Nüesch, D. Baumgartner, A. Müller, A. Mündermann","doi":"10.3390/biomechanics2020020","DOIUrl":"https://doi.org/10.3390/biomechanics2020020","url":null,"abstract":"Rotator cuff tears are often linked to superior translational instability, but a thorough understanding of glenohumeral motion is lacking. This study aimed to assess the reliability of fluoroscopically measured glenohumeral translation during a shoulder abduction test. Ten patients with rotator cuff tears participated in this study. Fluoroscopic images were acquired during 30° abduction and adduction in the scapular plane with and without handheld weights of 2 kg and 4 kg. Images were labelled by two raters, and inferior-superior glenohumeral translation was calculated. During abduction, glenohumeral translation (mean (standard deviation)) ranged from 3.3 (2.2) mm for 0 kg to 4.1 (1.8) mm for 4 kg, and from 2.3 (1.5) mm for 0 kg to 3.8 (2.2) mm for 4 kg for the asymptomatic and symptomatic sides, respectively. For the translation range, moderate to good interrater (intra-class correlation coefficient ICC [95% confidence interval (CI)]; abduction: 0.803 [0.691; 0.877]; adduction: 0.705 [0.551; 0.813]) and intrarater reliabilities (ICC [95% CI]; abduction: 0.817 [0.712; 0.887]; adduction: 0.688 [0.529; 0.801]) were found. Differences in the translation range between the repeated measurements were not statistically significant (mean difference, interrater: abduction, −0.1 mm, p = 0.686; adduction, −0.1 mm, p = 0.466; intrarater: abduction 0.0 mm, p = 0.888; adduction, 0.2 mm, p = 0.275). This method is suitable for measuring inferior-superior glenohumeral translation in the scapular plane.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":"2 1","pages":"255 - 263"},"PeriodicalIF":0.0,"publicationDate":"2022-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48482031","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Remote Gait Analysis as a Proxy for Traditional Gait Laboratories: Utilizing Smartphones for Subject-Driven Gait Assessment across Differing Terrains 远程步态分析作为传统步态实验室的代理:利用智能手机进行不同地形的受试者驱动步态评估
Biomechanics (Basel, Switzerland) Pub Date : 2022-05-17 DOI: 10.3390/biomechanics2020019
Arjan Kahlon, Ashwini Sansare, A. Behboodi
{"title":"Remote Gait Analysis as a Proxy for Traditional Gait Laboratories: Utilizing Smartphones for Subject-Driven Gait Assessment across Differing Terrains","authors":"Arjan Kahlon, Ashwini Sansare, A. Behboodi","doi":"10.3390/biomechanics2020019","DOIUrl":"https://doi.org/10.3390/biomechanics2020019","url":null,"abstract":"Gait analysis has applications in medical diagnosis, biometrics, and development of therapeutic rehabilitation interventions (such as orthotics, prosthetics, and exoskeletons). While offering accurate measurements, gait laboratories are expensive, not scalable, and not easily accessible. In a pandemic-afflicted world, where telemedicine is crucial, there is need for subject-driven data remote collection. This study proposed a remote and purely subject-driven procedure for reproducible and scalable collection of real-life gait data. To evaluate the feasibility of our proposed procedure, the spatiotemporal parameters of gait were compared across two real-life terrains using a smartphone application on a focus population of healthy middle-aged individuals. Previous research validated smartphone motion sensors as accurate instruments for gait analysis, but required highly supervised, controlled environments on smaller sample sizes, thereby limiting application in real-life gait analysis. To this end, a custom-designed mobile application was developed to record lower extremity angular velocities on 69 healthy middle-aged adults; factoring in a subject-driven data submission error rate (DSER) of 17.4%, there were 57 usable data sets for analysis. Comparisons of spatiotemporal gait parameters across primary outcome measures on grass versus asphalt revealed significant measurable increases in gait duration (stride time), valley depth (max swing phase), and peak-to-valley (max stance phase to max swing phase). These results demonstrated the feasibility of using smartphones for a remote and fully subject-driven gait data collection. Additionally, our data analysis showed that even in short trials, a physical environmental load has a substantial and measurable effect on the gait of the understudied middle-aged population.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41953811","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Segmental and Intersegmental Coordination Characteristics of a Cognitive Movement Control Test: Quantifying Loss of Movement Choices 认知运动控制测试的节段和节段间协调特征:量化运动选择的损失
Biomechanics (Basel, Switzerland) Pub Date : 2022-05-13 DOI: 10.3390/biomechanics2020018
Lincoln Blandford, Emily J. Cushion, Ryan Mahaffey
{"title":"Segmental and Intersegmental Coordination Characteristics of a Cognitive Movement Control Test: Quantifying Loss of Movement Choices","authors":"Lincoln Blandford, Emily J. Cushion, Ryan Mahaffey","doi":"10.3390/biomechanics2020018","DOIUrl":"https://doi.org/10.3390/biomechanics2020018","url":null,"abstract":"Cognitive movement control tests are hypothesized to reveal reduced coordination variability, a feature of motor behaviour linked to clinical presentations. Exploration of this proposition via kinematic analysis of test pass and fail conditions is yet to be conducted. Kinematics (3D) were collected as 28 participants were qualitatively rated during nine trials of a cognitive movement control test. Ten female and two male participants passing the test were matched to twelve participants who failed (three males, nine females). Sagittal plane pelvis and knee angles were determined. Peak pelvic deviation and knee flexion maxima/minima were compared between groups. Classification tree analysis explored relationships between test failure and pelvis–knee intersegmental coordination strategy classifications derived from novel and traditional vector coding techniques. Coordination variability waveforms were assessed via SPM. Age, BMI, and knee flexion values did not differ between the groups (p > 0.05); however, participants rated as failing the test displayed greater pelvic deviation (p < 0.05). Classification tree analysis revealed a greater use of pelvic dominant intersegmental coordination strategies from both vector coding techniques (p < 0.001) by fail-group participants. The fail-group also displayed lower coordination variability for novel (p < 0.05), but not traditional (p > 0.05) vector coding technique waveforms, supporting the premise that the testing protocol may act as a qualitative approach to inform on features of motor behavior linked to clinical presentations.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46687136","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Influence of Different Footwear Insole Stiffness on Center of Pressure and Ankle Kinematics during Walking: A Case Report 不同鞋垫刚度对步行时压力中心及踝关节运动的影响:1例报告
Biomechanics (Basel, Switzerland) Pub Date : 2022-05-01 DOI: 10.3390/biomechanics2020017
Li Jin
{"title":"The Influence of Different Footwear Insole Stiffness on Center of Pressure and Ankle Kinematics during Walking: A Case Report","authors":"Li Jin","doi":"10.3390/biomechanics2020017","DOIUrl":"https://doi.org/10.3390/biomechanics2020017","url":null,"abstract":"During locomotion, the foot–ankle system plays an important role for forward progression of the body. The center of pressure (COP) is regarded as the point of the ground reaction force (GRF) vector acting on the foot surface during the stance phase. COP movement trajectory and velocity reflect the stance phase forward progression of the foot segment and the ankle joint motion characteristics. This study aimed to investigate different levels of footwear insole stiffness on COP forward velocity, GRF and ankle joint angles during walking stance phase. Two healthy subjects (one female, one male; age 26.5 ± 6.4 years, height 168.5 ± 2.1 cm, weight 64.9 ± 5.4 kg) participated in this study. Subjects were asked to walk along a 10 m walkway at two different speeds: self–selected normal (SSN) and self–selected fast (SSF). Within each walking speed, subjects were required to walk under two different insole stiffness conditions: (1) normal shoe insole (NSI) from the testing shoe (Nike Free RN Flyknit 2017) used in this study; (2) 1.6 mm thick carbon fiber insole (CFI) fitted within the testing shoe. Stiffer insole (CFI) significantly decreased peak ankle internal rotation angle (p = 0.001) and sagittal plane angle ROM (p = 0.022); additionally, CFI significantly increased peak ankle eversion angle compared to the NSI condition (p = 0.028). In conclusion, increasing footwear insole stiffness would alter stance phase ankle joint motion at SSF walking speed. Additionally, stiffer insoles may tend to decrease COP peak velocity at the initial heel strike and the terminal stance phase. Future research should investigate the combined effects of various insole properties on lower extremity system kinematic and kinetic patterns in various locomotion activities.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42577313","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Fluid–Structure Interaction Modeling of Ascending Thoracic Aortic Aneurysms in SimVascular SimVascular中胸升主动脉瘤流固耦合模型的建立
Biomechanics (Basel, Switzerland) Pub Date : 2022-05-01 DOI: 10.3390/biomechanics2020016
Rodrigo Valente, André Mourato, M. Brito, J. Xavier, A. Tomás, S. Avril
{"title":"Fluid–Structure Interaction Modeling of Ascending Thoracic Aortic Aneurysms in SimVascular","authors":"Rodrigo Valente, André Mourato, M. Brito, J. Xavier, A. Tomás, S. Avril","doi":"10.3390/biomechanics2020016","DOIUrl":"https://doi.org/10.3390/biomechanics2020016","url":null,"abstract":"Ascending Thoracic Aortic Aneurysm (ATAA) is a permanent dilatation of the aorta which is usually related to tissue degeneration, hemodynamic conditions, lifestyle, environmental and genetic factors. As the mechanical conditions can become critical in a dilated aorta, a patient-specific computational model can be very useful to assist clinical decisions in the management of ATAAs. In this article, we model the biomechanical conditions of ATAA by performing Fluid-Structure Interaction (FSI) simulations in the SimVascular open-source software package. The patient-specific geometric model is reconstructed from Computed Tomography scan (CT). The numerical implementation takes into account patient-specific outlet conditions and a temporal flow variation at the model inlet. We performed a mesh convergence analysis on a new mesh reconstruction method in SimVascular and showed that it can significantly reduce the computational cost without impacting the accuracy.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43414651","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Feasibility of a Full-Field Measurements-Based Protocol for the Biomechanical Study of a Lumbar Belt: A Case Study 基于全场测量的腰椎安全带生物力学研究方案的可行性:一个案例研究
Biomechanics (Basel, Switzerland) Pub Date : 2022-04-14 DOI: 10.3390/biomechanics2020015
R. Bonnaire, W. Han, R. Convert, P. Calmels, J. Molimard
{"title":"Feasibility of a Full-Field Measurements-Based Protocol for the Biomechanical Study of a Lumbar Belt: A Case Study","authors":"R. Bonnaire, W. Han, R. Convert, P. Calmels, J. Molimard","doi":"10.3390/biomechanics2020015","DOIUrl":"https://doi.org/10.3390/biomechanics2020015","url":null,"abstract":"Low back pain represents a major economic and societal challenge due to its high prevalence. Lumbar orthoses are one of the recommended treatments. Even if previous results showed their clinical effects, the detailed mode of action is still poorly known, making the device design difficult. A renewed instrumentation and experimental protocol should bring better insight into the lumbar brace–trunk mechanical interaction. This instrumentation should give detailed information on the basic physical or geometrical parameters: the pressure applied on the trunk, the body shape and the strain in the belt. The principal objective of this study was to propose and validate a new measurement protocol, based on pressure mapping systems and full-field shape and strain measurement. The feasibility of the protocol was tested along with its validity and repeatability. The influence of various parameters, which could cause changes in the measurements, was tested with six different belt configurations on one subject. Measurements were also performed to study the impact of posture on pressure and strain. Both pressure and strain appeared to be asymmetric from left to right. The pressure applied by the lumbar belt on the back varies with breathing and with posture. This study showed that full-field measurements were necessary to render the high variability of pressure or strain around the trunk, under recommendations of their use to guarantee a satisfying repeatability.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48397665","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of Wall Compliance on the Flow Patterns in a Patient-Specific Brachio-Cephalic Arterio-Venous Fistula 管壁顺应性对患者特异性头臂动静脉瘘血流模式的影响
Biomechanics (Basel, Switzerland) Pub Date : 2022-04-08 DOI: 10.3390/biomechanics2020014
Neda Alam, D. Newport
{"title":"Influence of Wall Compliance on the Flow Patterns in a Patient-Specific Brachio-Cephalic Arterio-Venous Fistula","authors":"Neda Alam, D. Newport","doi":"10.3390/biomechanics2020014","DOIUrl":"https://doi.org/10.3390/biomechanics2020014","url":null,"abstract":"Patients with end stage renal disease require some form of vascular access for treatment, with Arterio-Venous Fistulas (avf) being the preferred form available due to better patency rates. However, they continue to present complications after creation, leading to early or late failure. While many studies are examining the flow in patient-specific fistulas, they often neglect the influence of vessel compliance on its hemodynamics. The objective of this study is to investigate the effect of wall compliance on the complex hemodynamics of a patient-specific brachio-cephalic avf and how it differs from a rigid fistula. Particle Image Velocimetry (piv) was used to capture the flow pattern within the fistula for both steady (Re = 1817) and pulsatile (Reav=1817, Remax=2232) flow conditions. The results were compared to rigid model measurements performed under the same Reynolds number. The streamline plots and coefficient of variation results did not differ significantly between the models; however, the non-dimensional velocity and directional variability results did vary between the two fistulas. A difference of approximately 8% was seen between the two models for both steady and pulsatile flow. The findings of this study suggest that to determine the bulk flow, a rigid model is adequate, but to capture the finer details of the flow, a compliant model is necessary.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46226917","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Virgin Passive Colon Biomechanics and a Literature Review of Active Contraction Constitutive Models 原始被动结肠生物力学及主动收缩本构模型的文献综述
Biomechanics (Basel, Switzerland) Pub Date : 2022-03-22 DOI: 10.3390/biomechanics2020013
A. Bhattarai, A. Horbach, Manfred Staat, W. Kowalczyk, T. N. Tran
{"title":"Virgin Passive Colon Biomechanics and a Literature Review of Active Contraction Constitutive Models","authors":"A. Bhattarai, A. Horbach, Manfred Staat, W. Kowalczyk, T. N. Tran","doi":"10.3390/biomechanics2020013","DOIUrl":"https://doi.org/10.3390/biomechanics2020013","url":null,"abstract":"The objective of this paper is to present our findings on the biomechanical aspects of the virgin passive anisotropic hyperelasticity of the porcine colon based on equibiaxial tensile experiments. Firstly, the characterization of the intestine tissues is discussed for a nearly incompressible hyperelastic fiber-reinforced Holzapfel–Gasser–Ogden constitutive model in virgin passive loading conditions. The stability of the evaluated material parameters is checked for the polyconvexity of the adopted strain energy function using positive eigenvalue constraints of the Hessian matrix with MATLAB. The constitutive material description of the intestine with two collagen fibers in the submucosal and muscular layer each has been implemented in the FORTRAN platform of the commercial finite element software LS-DYNA, and two equibiaxial tensile simulations are presented to validate the results with the optical strain images obtained from the experiments. Furthermore, this paper also reviews the existing models of the active smooth muscle cells, but these models have not been computationally studied here. The review part shows that the constitutive models originally developed for the active contraction of skeletal muscle based on Hill’s three-element model, Murphy’s four-state cross-bridge chemical kinetic model and Huxley’s sliding-filament hypothesis, which are mainly used for arteries, are appropriate for numerical contraction numerical analysis of the large intestine.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49070257","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Femoral Bone Strength Prediction Using Isotopological B-Spline-Transformed Meshes 用同位素b样条变换网格预测股骨骨强度
Biomechanics (Basel, Switzerland) Pub Date : 2022-03-16 DOI: 10.3390/biomechanics2010012
L. Steiner, A. Synek, D. Pahr
{"title":"Femoral Bone Strength Prediction Using Isotopological B-Spline-Transformed Meshes","authors":"L. Steiner, A. Synek, D. Pahr","doi":"10.3390/biomechanics2010012","DOIUrl":"https://doi.org/10.3390/biomechanics2010012","url":null,"abstract":"Finite element (FE) analysis can predict proximal human femoral strength. Automated meshing and identifying subregions with high relevance for strength prediction could reduce the laborious modeling process. Mesh morphing based on free-form registration provides a high level of automation and inherently creates isotopological meshes. The goals of this study were to investigate if FE models based on free-form transformed meshes predict experimental femoral strength as well as manually created FE models and to identify regions and parameters with highest correlation to femoral strength. Subject-specific meshes and FE models were created from a set of quantitative CT images (QCT) using a B-Spline registration-based algorithm. Correlation of FE-predicted bone strength and local parameters with experimental bone strength were investigated. FE models based on transformed meshes closely resembled manually created counterparts, with equally strong correlations with experimental bone strength (R2=0.81 vs. R2=0.80). The regional analysis showed strong correlations (0.6<R2<0.7) of experimental strength with local parameters. No subregion or parameter lead to stronger correlation than FE predicted bone strength. B-spline-transformed meshes can be used to create FE models, able to predict femoral bone strength and simplify FE model generation. They can be used to reveal relations of local parameters with failure load.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2022-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47298129","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信