Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique最新文献

筛选
英文 中文
La MPR française et le programme d’action de la section européenne de MPR de l’Union européenne des médecins spécialistes (UEMS) 法国prm和欧洲医学专家联盟(UEMS) prm欧洲部分的行动计划
A. Delarque, G. de Korvin, J.-M. Viton
{"title":"La MPR française et le programme d’action de la section européenne de MPR de l’Union européenne des médecins spécialistes (UEMS)","authors":"A. Delarque, G. de Korvin, J.-M. Viton","doi":"10.1016/j.annrmp.2008.06.002","DOIUrl":"10.1016/j.annrmp.2008.06.002","url":null,"abstract":"","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.annrmp.2008.06.002","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"27576801","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Stimulation cérébrale profonde et maladie de Parkinson 深层脑刺激与帕金森病
D. Boisson
{"title":"Stimulation cérébrale profonde et maladie de Parkinson","authors":"D. Boisson","doi":"10.1016/j.annrmp.2008.04.008","DOIUrl":"10.1016/j.annrmp.2008.04.008","url":null,"abstract":"<div><p>Ten years after the therapeutic revolution that emerged from the discovery of <span>l</span>-dopa, some pioneer teams led the rebirth of a new nonablative stereotaxical surgical treatment, which came from the interest of high frequency stimulation. Three targets were retained as the main location of a reversible functional inhibition: Vim, GPI and STN. The unilateral or bilateral stimulation, adjustable and possibly reversible, led to an exceptional medicosurgical collaboration, within expert dedicated places, based on the control of the Parkinson's disease's (PD) triad. The stimulation was initially applied to the most advanced forms of PD, after the medical control period of the motor performance, when the pejorative effects of the evolution settled and/or when side effects of the treatment appeared. Subsequently, the research of selection criterions and the strict control of the stereotaxical procedure during the per- and postoperatory period, with the collaboration of the patient and his family, progressively brought different teams to an earlier indication of this new treatment option, up to now reserved for fully medicosurgical concerted cases. Apparition of cognitive and postural decline as well as the known resistance stage to <span>l</span>-dopa tend to become a real contra-indication. Despite the initial relative weakness of controlled studies with limited number of patients, the multiplication of follow-up studies among high quality multicentric cohorts enabled the validation of practices respecting the differences related to the initial background of each different team. In Europe first, the prevalence of the subthalamic target is now to be generally admitted. A new objective is now imposing itself: trying to maintain the patient's quality of life, beyond the only motor benefit. The social adaptation of a young patient is now also taken into account. If this exemplary clinical research approach, efficient for a few highly selected patients, has not transformed the long-term prognostic of the PD, it will continue to improve the comprehension of this degenerative pathology and its extension. It still remains hopeful for the future in the actual constant technological progress, and that probably beyond the only PD.</p></div>","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.annrmp.2008.04.008","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"27495903","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Électrostimulation et rééducation périnéale de l’incontinence urinaire et des troubles mictionnels non neurologiques 尿失禁和非神经系统排尿障碍的电刺激和会阴康复
M. Perrigot, B. Pichon, A. Peskine, K. Vassilev
{"title":"Électrostimulation et rééducation périnéale de l’incontinence urinaire et des troubles mictionnels non neurologiques","authors":"M. Perrigot,&nbsp;B. Pichon,&nbsp;A. Peskine,&nbsp;K. Vassilev","doi":"10.1016/j.annrmp.2008.04.012","DOIUrl":"10.1016/j.annrmp.2008.04.012","url":null,"abstract":"<div><p>A literature survey of 106 articles shows that standard electrostimulation is an effective treatment of urinary incontinence and urinary disorders with bladder instability. Bladder inhibition is obtained by applying an alternating current at a frequency of between 5 and 25<!--> <!-->Hz and with a pulse width of between 0.2 and 0.5<!--> <!-->ms. In 19 articles (including three randomized, placebo-controlled studies), good results were achieved in 60 to 90% of cases, depending on the exact method (i.e. chronic or acute stimulation). Standard electrostimulation is also efficient in stress urinary incontinence. Urethral closure is obtained by applying a 50<!--> <!-->Hz alternating current with, again, a pulse width of between 0.2 and 0.5<!--> <!-->ms. In 21 articles (including two randomized, placebo-controlled studies), good results were achieved in 47.5 to 77% of cases. Treatments combining perineal rehabilitation (behavioural education, muscle improvement and biofeed-back) and electrostimulation are reported by 10 authors, with good results in 70 to 80% of cases after 10 to 12 sessions. According to 14 studies, neuromodulation is also an efficient treatment for complex urinary disorders, urgency, pollakiuria and dysuria. The recommended stimulation parameters are a frequency of 10 to 15<!--> <!-->Hz and a pulse width of 210<!--> <!-->ms. Good results were found in 34 to 94% of cases (with between 60 and 75% in an international, multicenter study). The overall results different from one study to another because of the need to harmonize stimulation parameters, choice of the study population and treatment follow-up with self-training programs and therapeutic education.</p></div>","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.annrmp.2008.04.012","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"27573578","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Agenda 议程
{"title":"Agenda","authors":"","doi":"10.1016/S0168-6054(08)00197-9","DOIUrl":"https://doi.org/10.1016/S0168-6054(08)00197-9","url":null,"abstract":"","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0168-6054(08)00197-9","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"137435067","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"OA","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Analyse de livres 书籍分析
{"title":"Analyse de livres","authors":"","doi":"10.1016/j.annrmp.2008.05.008","DOIUrl":"https://doi.org/10.1016/j.annrmp.2008.05.008","url":null,"abstract":"","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.annrmp.2008.05.008","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"137435068","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Electrical stimulation and muscle strengthening 电刺激和肌肉强化
P. Dehail , C. Duclos , M. Barat
{"title":"Electrical stimulation and muscle strengthening","authors":"P. Dehail ,&nbsp;C. Duclos ,&nbsp;M. Barat","doi":"10.1016/j.annrmp.2008.05.001","DOIUrl":"10.1016/j.annrmp.2008.05.001","url":null,"abstract":"<div><h3>Objectives</h3><p>To identify the effects of application methods and indications of direct muscle electrostimulation on strength gain.</p></div><div><h3>Methods</h3><p>Literature review and analysis of articles from Medline database with the following entries: muscular or neuromuscular, electromyostimulation, electrical stimulation, strengthening, strength training, immobilization, muscle dystrophy, bed-rest, bed-bound, knee or hip surgery, postoperative phase, cachexia, sarcopenia, and their French equivalent.</p></div><div><h3>Results</h3><p>Because of its specific muscle recruitment order, different from that of voluntary contraction, direct muscle electrostimulation is theoretically a complementary tool for muscle strengthening. It can be used in healthy subjects and in several affections associated with muscle function loss. Its interest seems well-established for post-traumatic or postsurgery lower-limb immobilizations but too few controlled studies have clearly shown the overall benefits of its application in other indications. Whatever the indication, superimposed or combined electrostimulation techniques are generally more efficient than electrostimulation alone.</p></div><div><h3>Conclusion</h3><p>Even though widely used, the level of evidence for the efficiency of electromyostimulation is still low. For strength gains, it yielded no higher benefits than traditional strengthening methods. Its interest should be tested in medical affections leading to major muscle deconditioning or in sarcopenia.</p></div>","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.annrmp.2008.05.001","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"37430838","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 78
Histoire de l’électrostimulation en médecine et en rééducation 电刺激在医学和康复中的历史
R. Dolhem
{"title":"Histoire de l’électrostimulation en médecine et en rééducation","authors":"R. Dolhem","doi":"10.1016/j.annrmp.2008.04.004","DOIUrl":"10.1016/j.annrmp.2008.04.004","url":null,"abstract":"<div><p>In antiquity, the electrical properties of torpedo fishes were used for therapeutic purposes (in headache and gout). In the 18th century, some practitioners used Leyde jars (Musschenbroek, 1746) and electrostatic devices to treat (notably) neuralgia, contractures and paralysis. L. Galvani's (1737–1798) description of “animal electricity” and A. Volta's (1745–1827) discovery of bimetallic electricity and invention of the voltaic battery prompted renewed interest in the therapeutic effects of galvanism. In the mid-19th century, Duchenne de Boulogne (1806–1875) improved electrotherapy procedures with volta and magnetofaradaic apparatuses. During the first half of the 20th century, research in electrophysiology (chronaxia and rheobasis) progressed in parallel with the work of electroradiologists such as A. d’Arsonval (1851–1940) and his high-frequency currents. From the 1960s onwards, the combination of progress in electronics with data processing and the miniaturization of medical devices opened up the way to today's electrostimulation techniques and their implementations in physical medicine and rehabilitation.</p></div>","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.annrmp.2008.04.004","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"27486963","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Low-frequency electromyostimulation and chronic heart failure 低频肌电刺激与慢性心力衰竭
J.-M. Casillas , V. Gremeaux , M. Labrunee , O. Troigros , Y. Laurent , G. Deley , J.-C. Eicher
{"title":"Low-frequency electromyostimulation and chronic heart failure","authors":"J.-M. Casillas ,&nbsp;V. Gremeaux ,&nbsp;M. Labrunee ,&nbsp;O. Troigros ,&nbsp;Y. Laurent ,&nbsp;G. Deley ,&nbsp;J.-C. Eicher","doi":"10.1016/j.annrmp.2008.04.006","DOIUrl":"10.1016/j.annrmp.2008.04.006","url":null,"abstract":"<div><p>Low-frequency electromyostimulation (EMS) acts on the skeletal muscle abnormalities that aggravate intolerance to effort in patients with chronic heart failure (CHF). It improves the oxidative capacity of muscles and thus enhances aerobic performance and physical capacity to almost the same degree, as does conventional physical training. No local or hemodynamic intolerance has been reported, even in cases of severe CHF. However, the presence of a pacemaker is one of the relative contra-indications (prior evaluation of tolerance is required), while that of an implanted defibrillator is one of the absolute contra-indications. EMS is an alternative to physical effort training when the latter is impossible due to a high degree of deconditioning or because there is a contra-indication, which may be temporary, due to the risk of acute decompensation and/or rhythm troubles. EMS can also be used in patients waiting for a heart transplant or in CHF patients who are unwilling to engage in physical activities. As EMS is not expensive and easy to set up, its use is likely to develop in the future.</p></div>","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.annrmp.2008.04.006","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"27495902","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 15
Functional electrical stimulation of walking: Function, exercise and rehabilitation 步行的功能性电刺激:功能、运动和康复
T.A. Thrasher , M.R. Popovic
{"title":"Functional electrical stimulation of walking: Function, exercise and rehabilitation","authors":"T.A. Thrasher ,&nbsp;M.R. Popovic","doi":"10.1016/j.annrmp.2008.05.006","DOIUrl":"10.1016/j.annrmp.2008.05.006","url":null,"abstract":"<div><p>For nearly half a century, functional electrical stimulation (FES) has been used to restore walking for people with paralysis and muscle weakness due to stroke and spinal cord injury. The first applications of the technology were intended to permanently replace lost neuromuscular function. Later, FES-assisted walking was found to have therapeutic benefits that include increased muscle strength, cardiovascular fitness and improved gait function that could be maintained after use of FES was terminated. In this review, we examine some of the major FES-assisted walking systems that have been developed for experimental and commercial purposes over the last four and a half decades, including foot drop stimulators, multichannel stimulators and hybrid orthotic systems.</p></div>","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.annrmp.2008.05.006","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"37430837","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 102
Validation transculturelle de l’Oswestry disability index en français 法语oswestry残疾指数的跨文化验证
D. Vogler , R. Paillex , M. Norberg , P. de Goumoëns , J. Cabri
{"title":"Validation transculturelle de l’Oswestry disability index en français","authors":"D. Vogler ,&nbsp;R. Paillex ,&nbsp;M. Norberg ,&nbsp;P. de Goumoëns ,&nbsp;J. Cabri","doi":"10.1016/j.annrmp.2008.03.006","DOIUrl":"10.1016/j.annrmp.2008.03.006","url":null,"abstract":"<div><h3>Aim</h3><p>The aim of this study was to interpret and validate a French version of the Oswestry disability index (ODI), using a cross-cultural validation method. The validity and reliability of the questionnaire was assessed in order to ensure the psychometric characteristics.</p></div><div><h3>Method</h3><p>The cross-cultural validation was carried out according to Beaton's methodology. The study was conducted with 41 patients suffering from low back pain. The correlation between the ODI and the Roland-Morris disability questionnaire (RMDQ), the medical outcome survey short form-36 (MOS SF-36) and a pain visual analogical scale (VAS) was assessed.</p></div><div><h3>Results</h3><p>The validity of the Oswestry questionnaire was studied using the Cronbach Alpha coefficient calculation: 0.87 (<em>n</em> <!-->=<!--> <!-->36). The significant correlation between the ODI and RMDQ was 0.8 (<em>P</em> <!-->&lt;<!--> <!-->0.001, <em>n</em> <!-->=<!--> <!-->41) and 0.71 (<em>P</em> <!-->&lt;<!--> <!-->0.001, <em>n</em> <!-->=<!--> <!-->36) for the pain VAS. The correlation between the ODI and certain subscales (physical functioning 0.7 (<em>P</em> <!-->&lt;<!--> <!-->0.001, <em>n</em> <!-->=<!--> <!-->41), physical role 0.49 et bodily pain 0.73 (<em>P</em> <!-->&lt;<!--> <!-->0.001, <em>n</em> <!-->=<!--> <!-->41)) of the MOS SF-36 were equally significant. The reproducibility of the ODI was calculated using the Wilcoxon matched pairs test: there was no significant difference for eight out of ten sections or for the final score.</p></div><div><h3>Conclusion</h3><p>This French translation of the ODI should be considered as valid and reliable. It should be used for any future clinical studies carried out using French language patients. Complimentary studies must be completed in order to assess its sensitivity to change in the event of any modifications in the patients functional capacity.</p></div>","PeriodicalId":72206,"journal":{"name":"Annales de readaptation et de medecine physique : revue scientifique de la Societe francaise de reeducation fonctionnelle de readaptation et de medecine physique","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2008-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.annrmp.2008.03.006","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"27460021","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 37
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信