Satoshi Imajo, Yoshinori Tanabe, Nobue Nakamura, Mitsugi Honda, M. Kuroda
{"title":"Objective evaluation method using multiple image analyses for panoramic radiography improvement","authors":"Satoshi Imajo, Yoshinori Tanabe, Nobue Nakamura, Mitsugi Honda, M. Kuroda","doi":"10.2478/pjmpe-2023-0010","DOIUrl":"https://doi.org/10.2478/pjmpe-2023-0010","url":null,"abstract":"Abstract Introduction In the standardization of panoramic radiography quality, the education and training of beginners on panoramic radiographic imaging are important. We evaluated the relationship between positioning error factors and multiple image analysis results for reproducible panoramic radiography. Material and methods Using a panoramic radiography system and a dental phantom, reference images were acquired on the Frankfurt plane along the horizontal direction, midsagittal plane along the left–right direction, and for the canine on the forward–backward plane. Images with positioning errors were acquired with 1–5 mm shifts along the forward– backward direction and 2–10° rotations along the horizontal (chin tipped high/low) and vertical (left–right side tilt) directions on the Frankfurt plane. The cross-correlation coefficient and angle difference of the occlusion congruent plane profile between the reference and positioning error images, peak signal-to-noise ratio (PSNR), and deformation vector value by deformable image registration were compared and evaluated. Results The cross-correlation coefficients of the occlusal plane profiles showed the greatest change in the chin tipped high images and became negatively correlated from 6° image rotation (r = −0.29). The angle difference tended to shift substantially with increasing positioning error, with an angle difference of 8.9° for the 10° chin tipped low image. The PSNR was above 30 dB only for images with a 1-mm backward shift. The positioning error owing to the vertical rotation was the largest for the deformation vector value. Conclusions Multiple image analyses allow to determine factors contributing to positioning errors in panoramic radiography and may enable error correction. This study based on phantom imaging can support the education of beginners regarding panoramic radiography.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"12 1","pages":"85 - 91"},"PeriodicalIF":0.4,"publicationDate":"2023-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"86662436","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Kajewska, Agata Stanek, Karolina Sieroń, A. Cholewka
{"title":"May thermal imaging be useful in early diagnosis of lower extremities chronic venous disease?","authors":"J. Kajewska, Agata Stanek, Karolina Sieroń, A. Cholewka","doi":"10.2478/pjmpe-2023-0009","DOIUrl":"https://doi.org/10.2478/pjmpe-2023-0009","url":null,"abstract":"Abstract Introduction: World statistics confirmed that about 40-50% of men and 50-55% of women suffer from chronic venous disease. Currently, the Duplex ultrasound is the leading diagnostic method for chronic venous disease (CVD), but it has some limitations. Therefore, it is important to find a new diagnostic technique that will provide additional parameters, describing not only structural but also early metabolic and functional changes. Materials and Methods: This study aimed to demonstrate the usefulness of the thermal imaging technique in the diagnosis of chronic venous disease. Results were obtained for two groups: 61 patients suffering from the primary chronic venous disease (CVD group) and 30 healthy people (control group). The obtained results compared the thermal imaging parameters to data obtained from the ultrasound examination. Parameters such as the reflux duration and extent of the CEAP classification were correlated with the mean temperature of the limb, the mean temperature of the lesion (determined using two methods), and the thermal range. Based on data obtained during the study, correlation coefficients were calculated for individual parameters. Results: The results obtained show that the mean limb temperature, and especially the mean temperature of a proposed isothermal area, is significantly correlated with the range of reflux. The conducted tests showed the correlation between some thermal and ultrasonic parameters determined by Spearman's coefficient is 0.4 (p < 0.05). Conclusions: Thus, parameters such as the isothermal area and the thermal range may be used as a preliminary quantitative diagnosis, similarly to those derived from the Duplex ultrasound.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"1 1","pages":"73 - 84"},"PeriodicalIF":0.4,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90752656","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The Software with a Graphical User Interface for GAMOS: Basic Training and an Educational Tool for Medical Physicists","authors":"R. Kandemir, İ. Özsoykal, K. Akgüngör","doi":"10.2478/pjmpe-2023-0005","DOIUrl":"https://doi.org/10.2478/pjmpe-2023-0005","url":null,"abstract":"Abstract Introduction: It is necessary to have special experience to perform the Monte Carlo calculation, commonly used in medical physics and accepted as the gold standard. In this study, we developed software to teach basic steps to medical physicists who were inexperienced in the medical linear accelerator Monte Carlo simulation. Material and methods: For the design interface, a software called GamosLinacGUI was developed using Gnome Builder, Python, and GTK. The user, who wants to learn the basics of GAMOS and simulate a linear accelerator, can enter the values in the software, select some options and quickly create geometry and physics files. Results: For proof that the software generates the correct inputs for GAMOS simulation in the same conditions for the measurements and calculations. Required files for GAMOS have been created and tested and run the simulation accordingly. This software was tested with Centos Linux. Conclusions: GamosLinacGUI has been successfully developed, which creates the geometry and physics files required for the simulation with GAMOS as a training and learning tool.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"9 1","pages":"42 - 49"},"PeriodicalIF":0.4,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89292177","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Karbowski, Bartosz Kopiczak, R. Chrzan, J. Gawlik, J. Szaleniec
{"title":"Accuracy of virtual rhinomanometry","authors":"K. Karbowski, Bartosz Kopiczak, R. Chrzan, J. Gawlik, J. Szaleniec","doi":"10.2478/pjmpe-2023-0008","DOIUrl":"https://doi.org/10.2478/pjmpe-2023-0008","url":null,"abstract":"Abstract Introduction: This paper describes the results of research aimed at developing a method of otolaryngological diagnosis based on computational fluid dynamics, which has been called Virtual Rhinomanometry. Material and methods: Laboratory studies of airflows through a 3D printed model of nasal cavities based on computed tomography image analysis have been performed. The CFD results have been compared with those of an examination of airflow through nasal cavities (rhinomanometry) of a group of 25 patients. Results: The possibilities of simplifying model geometry for CFD calculations have been described, the impact of CT image segmentation on geometric model accuracy and CFD simulation errors have been analysed, and recommendations for future research have been described. Conclusions: The measurement uncertainty of the nasal cavities’ walls has a significant impact on CFD simulations. The CFD simulations better approximate RMM results of patients after anemization, as the influence of the nasal mucosa on airflow is then reduced. A minor change in the geometry of the nasal cavities (within the range of reconstruction errors by CT image segmentation) has a major impact on the results of CFD simulations.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"72 1","pages":"59 - 72"},"PeriodicalIF":0.4,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87409171","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Sitti M Rif’ah, C. Anam, H. Sutanto, R. Asiah, Heryani Cholid, G. Dougherty
{"title":"An in-house step-wedge phantom for the calibration of pixel values in CT localizer radiographs for water-equivalent diameter measurement","authors":"Sitti M Rif’ah, C. Anam, H. Sutanto, R. Asiah, Heryani Cholid, G. Dougherty","doi":"10.2478/pjmpe-2023-0006","DOIUrl":"https://doi.org/10.2478/pjmpe-2023-0006","url":null,"abstract":"Abstract Introduction: To develop an in-house acrylic-based step-wedge phantom with several thickness configurations for calibrating computed tomography (CT) localizer radiographs in order to measure the water-equivalent diameter (Dw) and the size-specific dose estimate (SSDE). Method: We developed an in-house step-wedge phantom using 3 mm thick acrylic, filled with water. The phantom had five steps with thicknesses of 6, 12, 18, 24, and 30 cm. The phantom was scanned using a 64-slice Siemens Definition AS CT scanner with tube currents of 50, 100, 150, 200, and 250 mA. The relationship between pixel value (PV) and water-equivalent thickness (tw) was obtained for the different step thicknesses. This was used to calibrate the CT localizer radiographs in order to measure Dw and SSDE. The results of Dw and SSDE from the radiographs were compared with those calculated from axial CT images. Results: The relationship between PV and tw from CT localizer radiographs of the phantom step-wedge produced a linear relationship with R2 > 0.990. The linear relationships of the Dw and SSDE values obtained from CT localizer radiographs and axial CT images had R2 values > 0.94 with a statistical test of p-value > 0.05. The Dw difference between those from CT localizer radiographs and axial CT images was 3.7% and the SSDE difference between both was 4.3%. Conclusion: We have successfully developed a step-wedge phantom to calibrate the relationship between PV and tw. Our phantom can be easily used to calibrate CT localizer radiographs in order to measure Dw and SSDE.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"38 1","pages":"50 - 57"},"PeriodicalIF":0.4,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79225607","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Iwona Dylong, P. Dolibog, Tomasz Mularz, J. Młynarski, S. Grzegorczyn
{"title":"The Changes of Elongation Index of erythrocytes caused by storage of blood at low temperature","authors":"Iwona Dylong, P. Dolibog, Tomasz Mularz, J. Młynarski, S. Grzegorczyn","doi":"10.2478/pjmpe-2023-0004","DOIUrl":"https://doi.org/10.2478/pjmpe-2023-0004","url":null,"abstract":"Abstract Introduction: An important parameter characterizing the ability of erythrocytes to deform depending on the blood flow conditions is the Elongation Index (EI), and it is a parameter defined by the shape of the erythrocyte obtained as a diffraction pattern of erythrocytes at different values of shear stresses. Material and methods: EI measurements at different shear stress were performed by Laser-assisted Optical Rotational Cell Analyzer (LORRCA) for erythrocytes derived from Tissue Bank in Katowice. Measurements were performed immediately after receiving them from Tissue Bank and after 2, 9, and 28 days of storage of samples at the temperature of 4°C in solution with the anticoagulant. Results: An increase in the erythrocytes Elongation Index in the first 9 days of storing samples at low temperatures was observed in the entire range of applied shear stresses. This indicates an increase in the elasticity of erythrocytes during short-term storage at 4°C. In turn, on the 28th day of erythrocyte storage, a significant decrease in the Elongation Index for shear stresses greater than 1 Pa was observed, which indicates the stiffening of the erythrocyte membrane structure, reducing their elasticity. The relative decrease in the Elongation Index of erythrocytes stored for 28 days compared to erythrocytes measured at the beginning was similar and slightly greater than 30% for shear stresses greater than 3 Pa. For shear stresses lower than 3 Pa, the relative change in elongation index was smaller than for shear stresses greater than 3 Pa and increased with the increase in shear stress. Conclusions: The elongation index of erythrocytes stored in the anticoagulant solution at 4°C, initially increases in the entire range of applied shear stresses in the first few days from the moment of blood collection and preparation at the Tissue Bank, and then decreases, but on the ninth day of storage the elongation index is still higher than for blood immediately after collection.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"135 1","pages":"35 - 41"},"PeriodicalIF":0.4,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"79484305","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Non-invasive method for blood glucose monitoring using ECG signal","authors":"Khadidja Fellah Arbi, S. Soulimane, F. Saffih","doi":"10.2139/ssrn.4068462","DOIUrl":"https://doi.org/10.2139/ssrn.4068462","url":null,"abstract":"Abstract Introduction: Tight glucose monitoring is crucial for diabetic patients by using a Continuous Glucose Monitor (CGM). The existing CGMs measure the Blood Glucose Concentration (BGC) from the interstitial fluid. These technologies are quite expensive, and most of them are invasive. Previous studies have demonstrated that hypoglycemia and hyperglycemia episodes affect the electrophysiology of the heart. However, they did not determine a cohort relationship between BGC and ECG parameters. Material and method: In this work, we propose a new method for determining the BGC using surface ECG signals. Recurrent Convolutional Neural Networks (RCNN) were applied to segment the ECG signals. Then, the extracted features were employed to determine the BGC using two mathematical equations. This method has been tested on 04 patients over multiple days from the D1namo dataset, using surface ECG signals instead of intracardiac signal. Results: We were able to segment the ECG signals with an accuracy of 94% using the RCNN algorithm. According to the results, the proposed method was able to estimate the BGC with a Mean Absolute Error (MAE) of 0.0539, and a Mean Squared Error (MSE) of 0.1604. In addition, the linear relationship between BGC and ECG features has been confirmed in this paper. Conclusion: In this paper, we propose the potential use of ECG features to determine the BGC. Additionally, we confirmed the linear relationship between BGC and ECG features. That fact will open new perspectives for further research, namely physiological models. Furthermore, the findings point to the possible application of ECG wearable devices for non-invasive continuous blood glucose monitoring via machine learning.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"05 1","pages":"1 - 9"},"PeriodicalIF":0.4,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"85966812","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. Ye, Wen-Hua Zhang, Jian Wang, Yanshan Zhang, Jia-Ming Wu
{"title":"The determination of virtual source position using convergent anti-trigonometric functions (arcCOS and arcSIN) method for scanning-passive scatter beam in carbon ion therapy","authors":"Y. Ye, Wen-Hua Zhang, Jian Wang, Yanshan Zhang, Jia-Ming Wu","doi":"10.2478/pjmpe-2023-0002","DOIUrl":"https://doi.org/10.2478/pjmpe-2023-0002","url":null,"abstract":"Abstract Introduction: We developed a convergent trigonometric functions technique (arcCOS, arcSIN) capable of dealing with the virtual source position delivered by different carbon ion energies from the pattern of scanning-passive scatter beam in this study. Materials and Methods: A home-made large-format CMOS sensor and Gaf Chromic EBT3 films were used for the virtual source position measurement. The Gaf films were embedded in a self-designed rectangular plastic frame to tighten the films and set up on a treatment couch for irradiation in the air with the film perpendicular to the carbon ion beam at the nominal source-axis-distance (SAD) as well as upstream and downstream from the SAD. The horizontal carbon ion beam with 5 energies at a machine opening field size was carried out in this study. The virtual source position was determined with a convergent arcCOS and arcSIN methods and compared with the linear regression by back-projecting the FWHM to zero at a distance upstream from the various source-film-distance. Results: The film FWHM measurement error of 0.5 mm (the large-format CMOS detectors was in pixel, a pixel equals 0.5 mm) leads to 1×10-3% deviation of α(cACOS and cASIN) at every assumed virtual source position. The overall uncertainty for the reproducibility of the calculated virtual source position by the assumed t in the vertical and horizontal directions amounts to 0.1%. The errors of calculated virtual source position by assumed t with back projecting FWHM to zero methods were within 1.1 ± 0.001, p = 0.033. The distance of virtual source positions is decreased from SAD with high to low energy. Conclusion: We have developed a technique capable of dealing with the virtual source position with a convergent arcCOS and arcSIN methods to avoid any manual measurement mistakes in scanning-passive scatter carbon ion beam. The method for investigating the virtual source position in the carbon ion beam in this study can also be used for external electrons and the proton.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"131 1","pages":"10 - 25"},"PeriodicalIF":0.4,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74927109","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Non-invasive method for blood glucose monitoring using ECG signal","authors":"Khadidja Fellah Arbi, Sofiane Soulimane, Faycal Saffih","doi":"10.2478/pjmpe-2023-0001","DOIUrl":"https://doi.org/10.2478/pjmpe-2023-0001","url":null,"abstract":"Abstract Introduction: Tight glucose monitoring is crucial for diabetic patients by using a Continuous Glucose Monitor (CGM). The existing CGMs measure the Blood Glucose Concentration (BGC) from the interstitial fluid. These technologies are quite expensive, and most of them are invasive. Previous studies have demonstrated that hypoglycemia and hyperglycemia episodes affect the electrophysiology of the heart. However, they did not determine a cohort relationship between BGC and ECG parameters. Material and method: In this work, we propose a new method for determining the BGC using surface ECG signals. Recurrent Convolutional Neural Networks (RCNN) were applied to segment the ECG signals. Then, the extracted features were employed to determine the BGC using two mathematical equations. This method has been tested on 04 patients over multiple days from the D1namo dataset, using surface ECG signals instead of intracardiac signal. Results: We were able to segment the ECG signals with an accuracy of 94% using the RCNN algorithm. According to the results, the proposed method was able to estimate the BGC with a Mean Absolute Error (MAE) of 0.0539, and a Mean Squared Error (MSE) of 0.1604. In addition, the linear relationship between BGC and ECG features has been confirmed in this paper. Conclusion: In this paper, we propose the potential use of ECG features to determine the BGC. Additionally, we confirmed the linear relationship between BGC and ECG features. That fact will open new perspectives for further research, namely physiological models. Furthermore, the findings point to the possible application of ECG wearable devices for non-invasive continuous blood glucose monitoring via machine learning.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"59 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"136172690","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
K. Radaideh, A. Al-Radaideh, R. Ramli, A. Saleh, Rasha Alshayeb
{"title":"Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan","authors":"K. Radaideh, A. Al-Radaideh, R. Ramli, A. Saleh, Rasha Alshayeb","doi":"10.2478/pjmpe-2023-0003","DOIUrl":"https://doi.org/10.2478/pjmpe-2023-0003","url":null,"abstract":"Abstract Background: Dose reference levels (DRLs) are used as indicators as well as guidance for dose optimization and to ensure justification of appropriate dose for a given clinical indication. The main aims of this study were to establish local DRLs for each CT imaging protocol as a reference point to evaluate the radiation dose indices and to compare our DRLs with those established in other countries and against the internationally reported guidelines. Materials and methods: 2000 CT dose reports of different adult imaging protocols from January 2021 until April 2022 were collected retrospectively at different hospitals in Jordan. Data were collected from CT scans that were performed using different types and models of CT scanners and included four adult non-enhanced, helical CT imaging protocols; Head, Chest, Abdomen-Pelvis, and Chest-Abdomen-Pelvis. Results: The average doses of CTDIvol, DLP, and effective dose were (65.11 mGy, 1232.71 mGy·cm, 2.83 mSv) for the head scan, (16.6 mGy, 586.6 mGy·cm, 8.21 mSv) for the chest scan, (17.91 mGy, 929.9 mGy·cm, 13.9 mSv) for the abdomen-pelvis scan, and (19.3 mGy, 1152 mGy·cm, 17.25 mSv) for the chest-abdomen-pelvis scan. In comparison with results from different international studies, DLP values measured in the present study were lower for the chest-abdomen-pelvis and abdomen-pelvis CT scans, and higher for the head CT and chest CT scans. Conclusions: It is very important that each country establishes its own DRLs and compares them with those reported by other countries, especially the developed ones. It is also important that these levels are regularly updated.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"6 1","pages":"26 - 34"},"PeriodicalIF":0.4,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88323064","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}