Drinking Water Engineering and Science最新文献

筛选
英文 中文
Riverbank filtration for the treatment of highly turbid Colombian rivers 河岸过滤法处理哥伦比亚高度浑浊的河流
Drinking Water Engineering and Science Pub Date : 2017-05-11 DOI: 10.5194/DWES-10-13-2017
J. Gutiérrez, D. Halem, L. Rietveld
{"title":"Riverbank filtration for the treatment of highly turbid Colombian rivers","authors":"J. Gutiérrez, D. Halem, L. Rietveld","doi":"10.5194/DWES-10-13-2017","DOIUrl":"https://doi.org/10.5194/DWES-10-13-2017","url":null,"abstract":"Abstract. The poor quality of many Colombian surface waters forces us to seek alternative, sustainable treatment solutions with the ability to manage peak pollution events and to guarantee the uninterrupted provision of safe drinking water to the population. This review assesses the potential of using riverbank filtration (RBF) for the highly turbid and contaminated waters in Colombia, emphasizing water quality improvement and the influence of clogging by suspended solids. The suspended sediments may be favorable for the improvement of the water quality, but they may also reduce the production yield capacity. The cake layer must be balanced by scouring in order for an RBF system to be sustainable. The infiltration rate must remain high enough throughout the river–aquifer interface to provide the water quantity needed, and the residence time of the contaminants must be sufficient to ensure adequate water quality. In general, RBF seems to be a technology appropriate for use in highly turbid and contaminated surface rivers in Colombia, where improvements are expected due to the removal of turbidity, pathogens and to a lesser extent inorganics, organic matter and micro-pollutants. RBF has the potential to mitigate shock loads, thus leading to the prevention of shutdowns of surface water treatment plants. In addition, RBF, as an alternative pretreatment step, may provide an important reduction in chemical consumption, considerably simplifying the operation of the existing treatment processes. However, clogging and self-cleansing issues must be studied deeper in the context of these highly turbid waters to evaluate the potential loss of abstraction capacity yield as well as the development of different redox zones for efficient contaminant removal.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"10 1","pages":"13-26"},"PeriodicalIF":0.0,"publicationDate":"2017-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45550588","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 14
Review of applications for SIMDEUM, a stochastic drinking water demand model with a small temporal and spatial scale SIMDEUM,一个小时空尺度的随机饮用水需求模型的应用综述
Drinking Water Engineering and Science Pub Date : 2017-04-26 DOI: 10.5194/DWES-10-1-2017
M. Blokker, C. Agudelo-Vera, A. Moerman, P. Thienen, I. Pieterse-Quirijns
{"title":"Review of applications for SIMDEUM, a stochastic drinking water demand model with a small temporal and spatial scale","authors":"M. Blokker, C. Agudelo-Vera, A. Moerman, P. Thienen, I. Pieterse-Quirijns","doi":"10.5194/DWES-10-1-2017","DOIUrl":"https://doi.org/10.5194/DWES-10-1-2017","url":null,"abstract":"Abstract. Many researchers have developed drinking water demand models with various temporal and spatial scales. A limited number of models is available at a temporal scale of 1 s and a spatial scale of a single home. The reasons for building these models were described in the papers in which the models were introduced, along with a discussion on their potential applications. However, the predicted applications are seldom re-examined. SIMDEUM, a stochastic end-use model for drinking water demand, has often been applied in research and practice since it was developed. We are therefore re-examining its applications in this paper. SIMDEUM's original purpose was to calculate maximum demands in order to design self-cleaning networks. Yet, the model has been useful in many more applications. This paper gives an overview of the many fields of application for SIMDEUM and shows where this type of demand model is indispensable and where it has limited practical value. This overview also leads to an understanding of the requirements for demand models in various applications.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"10 1","pages":"1-12"},"PeriodicalIF":0.0,"publicationDate":"2017-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47114326","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 25
Algorithms for optimization of branching gravity-driven water networks 分支重力驱动水网优化算法
Drinking Water Engineering and Science Pub Date : 2017-02-24 DOI: 10.5194/DWES-11-67-2018
Ian P. Dardani, Gerard F. Jones
{"title":"Algorithms for optimization of branching gravity-driven water networks","authors":"Ian P. Dardani, Gerard F. Jones","doi":"10.5194/DWES-11-67-2018","DOIUrl":"https://doi.org/10.5194/DWES-11-67-2018","url":null,"abstract":"Abstract. The design of a water network involves the selection of pipe diameters that\u0000satisfy pressure and flow requirements while considering cost. A variety of\u0000design approaches can be used to optimize for hydraulic performance or reduce\u0000costs. To help designers select an appropriate approach in the context of\u0000gravity-driven water networks (GDWNs), this work assesses three\u0000cost-minimization algorithms on six moderate-scale GDWN test cases. Two\u0000algorithms, a backtracking algorithm and a genetic algorithm, use a set of\u0000discrete pipe diameters, while a new calculus-based algorithm produces a\u0000continuous-diameter solution which is mapped onto a discrete-diameter set.\u0000The backtracking algorithm finds the global optimum for all but the largest\u0000of cases tested, for which its long runtime makes it an infeasible option.\u0000The calculus-based algorithm's discrete-diameter solution produced slightly\u0000higher-cost results but was more scalable to larger network cases.\u0000Furthermore, the new calculus-based algorithm's continuous-diameter and\u0000mapped solutions provided lower and upper bounds, respectively, on the\u0000discrete-diameter global optimum cost, where the mapped solutions were\u0000typically within one diameter size of the global optimum. The genetic\u0000algorithm produced solutions even closer to the global optimum with\u0000consistently short run times, although slightly higher solution costs were\u0000seen for the larger network cases tested. The results of this study highlight\u0000the advantages and weaknesses of each GDWN design method including closeness\u0000to the global optimum, the ability to prune the solution space of infeasible\u0000and suboptimal candidates without missing the global optimum, and algorithm\u0000run time. We also extend an existing closed-form model of Jones (2011) to\u0000include minor losses and a more comprehensive two-part cost model, which\u0000realistically applies to pipe sizes that span a broad range typical of GDWNs\u0000of interest in this work, and for smooth and commercial steel roughness\u0000values.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"11 1","pages":"67-85"},"PeriodicalIF":0.0,"publicationDate":"2017-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46785663","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Investigation of the relationship between drinking water quality based oncontent of inorganic components and landform classes using fuzzy AHP (casestudy: south of Firozabad, west of Fars province, Iran) 基于无机成分含量的饮用水水质与地形类型关系的模糊层次分析法研究(以伊朗法尔斯省西部菲罗扎巴德南部为例)
Drinking Water Engineering and Science Pub Date : 2016-10-28 DOI: 10.5194/DWES-9-57-2016
M. Mokarram, D. Sathyamoorthy
{"title":"Investigation of the relationship between drinking water quality based oncontent of inorganic components and landform classes using fuzzy AHP (casestudy: south of Firozabad, west of Fars province, Iran)","authors":"M. Mokarram, D. Sathyamoorthy","doi":"10.5194/DWES-9-57-2016","DOIUrl":"https://doi.org/10.5194/DWES-9-57-2016","url":null,"abstract":"Abstract. In this study, the fuzzy analytic hierarchy process (AHP) is used to study the relationship between drinking water quality based on content of inorganic components and landform classes in the south of Firozabad, west of Fars province, Iran. For determination of drinking water quality based on content of inorganic components, parameters of calcium (Ca), chlorine (Cl), magnesium (Mg), thorium (TH), sodium (Na), electrical conductivity (EC), sulfate (SO4), and total dissolved solids (TDS) were used. It was found that 8.29 % of the study area has low water quality; 64.01 %, moderate; 23.33 %, high; and 4.38 %, very high. Areas with suitable drinking water quality based on content of inorganic components are located in parts of the south-eastern and south-western parts of the study area. The relationship between landform class and drinking water quality based on content of inorganic components shows that drinking water quality based on content of inorganic components is high in the stream, valleys, upland drainages, and local ridge classes, and low in the plain small and midslope classes. In fact we can predict water quality using extraction of landform classes from a digital elevation model (DEM) by the Topographic Position Index (TPI) method, so that streams, valleys, upland drainages, and local ridge classes have more water quality than the other classes. In the study we determined that without measurement of water sample characteristics, we can determine water quality by landform classes.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"9 1","pages":"57-67"},"PeriodicalIF":0.0,"publicationDate":"2016-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71222793","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
Do low-cost ceramic water filters improve water security in rural SouthAfrica? 低成本的陶瓷滤水器能改善南非农村的水安全吗?
Drinking Water Engineering and Science Pub Date : 2016-10-11 DOI: 10.5194/DWES-9-47-2016
J. Lange, T. Materne, J. Grüner
{"title":"Do low-cost ceramic water filters improve water security in rural SouthAfrica?","authors":"J. Lange, T. Materne, J. Grüner","doi":"10.5194/DWES-9-47-2016","DOIUrl":"https://doi.org/10.5194/DWES-9-47-2016","url":null,"abstract":"Abstract. This study examined the performance of a low-cost ceramic candle filter system (CCFS) for point of use (POU) drinking water treatment in the village of Hobeni, Eastern Cape Province, South Africa. CCFSs were distributed in Hobeni and a survey was carried out among their users. The performance of 51 CCFSs was evaluated by dip slides and related to human factors. Already after two-thirds of their specified lifetime, none of the distributed CCFSs produced water without distinct contamination, and more than one-third even deteriorated in hygienic water quality. Besides the water source (springs were preferable compared to river or rain water), a high water throughput was the dominant reason for poor CCFS performance. A stepwise laboratory test documented the negative effects of repeated loading and ambient field temperatures. These findings suggest that not every CCFS type per se guarantees improved drinking water security and that the efficiency of low-cost systems should continuously be monitored. For this purpose, dip slides were found to be a cost-efficient alternative to standard laboratory tests. They consistently underestimated microbial counts but can be used by laypersons and hence by the users themselves to assess critical contamination of their filter systems.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"9 1","pages":"47-55"},"PeriodicalIF":0.0,"publicationDate":"2016-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71222724","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Application of machine learning for real-time evaluation of salinity (orTDS) in drinking water using photonic sensors 机器学习在光子传感器实时评估饮用水盐度中的应用
Drinking Water Engineering and Science Pub Date : 2016-09-26 DOI: 10.5194/DWES-9-37-2016
Sandipta Roy, Preeta Sharan
{"title":"Application of machine learning for real-time evaluation of salinity (orTDS) in drinking water using photonic sensors","authors":"Sandipta Roy, Preeta Sharan","doi":"10.5194/DWES-9-37-2016","DOIUrl":"https://doi.org/10.5194/DWES-9-37-2016","url":null,"abstract":"Abstract. The world is facing an unprecedented problem in safeguarding 0.4 % of potable water, which is gradually depleting day-by-day. From a literature survey it has been observed that the refractive index (RI) of water changes with a change in salinity or total dissolved solids (TDS). In this paper we have proposed an automatic system that can be used for real-time evaluation of salinity or TDS in drinking water. A photonic crystal (PhC) based ring resonator sensor has been designed and simulated using the MEEP (MIT Electromagnetic Equation Propagation) tool and the finite difference time domain (FDTD) algorithm. The modelled and designed sensor is highly sensitive to the changes in the RI of a water sample. This work includes a real-time-based natural sequence follower, which is a machine learning algorithm of the naive Bayesian type, a sequence of statistical algorithms implemented in MATLAB with reference to training data to analyse the sample water. Further interfacing has been done using the Raspberry Pi device to provide an easy display to show the result of water analysis. The main advantage of the designed sensor with an interface is to check whether the salinity or TDS in drinking water is less than 1000 ppm or not. If it is greater than or equal to 2000 ppm, the display shows “High Salinity/TDS Observed”, and if ppm are less than or equal to 1000 ppm, then the display shows “Low salinity/TDS Observed”. The proposed sensor is highly sensitive and it can detect changes in TDS level because of the influence of any dissolved substance in water.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"9 1","pages":"37-45"},"PeriodicalIF":0.0,"publicationDate":"2016-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71222679","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 11
Optimized photodegradation of Bisphenol A in water using ZnO, TiO 2 andSnO 2 photocatalysts under UV radiation as a decontamination procedure 紫外辐射下ZnO、tio2和sno2光催化剂对水中双酚A的光降解研究
Drinking Water Engineering and Science Pub Date : 2016-09-16 DOI: 10.5194/DWES-9-27-2016
Rudy K. Abo, N. Kummer, B. Merkel
{"title":"Optimized photodegradation of Bisphenol A in water using ZnO, TiO 2 andSnO 2 photocatalysts under UV radiation as a decontamination procedure","authors":"Rudy K. Abo, N. Kummer, B. Merkel","doi":"10.5194/DWES-9-27-2016","DOIUrl":"https://doi.org/10.5194/DWES-9-27-2016","url":null,"abstract":"Abstract. Experiments on photodegradation of Bisphenol A (BPA) were carried out in water samples by means photocatalytic and photo-oxidation methods in the presence of ZnO, TiO2 and SnO2 catalysts. The objective of this study was to develop an improved technique that can be used as a remediation procedure for a BPA-contaminated surface water and groundwater based on the UV solar radiation. The photodegradation of BPA in water performed under a low-intensity UV source mimics the UVC and UVA spectrum of solar radiation between 254 and 365 nm. The archived results reveal higher degradation rates observed in the presence of ZnO than with TiO2 and SnO2 catalysts during 20 h of irradiation. The intervention of the advanced photocatalytic oxidation (PCO) reduces the time of degradation to less than 1 h to reach a degradation rate of 90 % for BPA in water. The study proposes the use of ZnO as a competitor catalyst to the traditional TiO2, providing the most effective treatment of contaminated water with phenolic products.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"7 1","pages":"27-35"},"PeriodicalIF":0.0,"publicationDate":"2016-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71222664","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 40
Estimating fast and slow reacting components in surface water and groundwater using a two-reactant model 用双反应物模型估计地表水和地下水中的快、慢反应组分
Drinking Water Engineering and Science Pub Date : 2016-05-18 DOI: 10.5194/DWES-9-19-2016
P. Jamwal, M. Naveen, Y. Javeed
{"title":"Estimating fast and slow reacting components in surface water and groundwater using a two-reactant model","authors":"P. Jamwal, M. Naveen, Y. Javeed","doi":"10.5194/DWES-9-19-2016","DOIUrl":"https://doi.org/10.5194/DWES-9-19-2016","url":null,"abstract":"Abstract. Maintaining residual chlorine levels in a water distribution network is a challenging task, especially in the context of developing countries where water is usually supplied intermittently. To model chlorine decay in water distribution networks, it is very important to understand chlorine kinetics in bulk water. Recent studies have suggested that chlorine decay rate depends on initial chlorine levels and the type of organic and inorganic matter present in water, indicating that a first-order decay model is unable to accurately predict chlorine decay in bulk water. In this study, we employed the two-reactant (2R) model to estimate the fast and slow reacting components in surface water and groundwater. We carried out a bench-scale test for surface water and groundwater at initial chlorine levels of 1, 2, and 5 mg L−1. We used decay data sets to estimate optimal parameter values for both surface water and groundwater. After calibration, the 2R model was validated with two decay data sets with varying initial chlorine concentrations (ICCs). This study arrived at three important findings. (a) We found that the ratio of slow to fast reacting components in groundwater was 30 times greater than that of the surface water. This observation supports the existing literature which indicates the presence of high levels of slow reacting fractions (manganese and aromatic hydrocarbons) in groundwater. (b) Both for surface water and groundwater, we obtained good model prediction, explaining 97 % of the variance in data for all cases. The mean square error obtained for the decay data sets was close to the instrument error, indicating the feasibility of the 2R model for chlorine prediction in both types of water. (c) In the case of deep groundwater, for high ICC levels (> 2 mg L−1), the first-order model can accurately predict chlorine decay in bulk water.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"9 1","pages":"19-25"},"PeriodicalIF":0.0,"publicationDate":"2016-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71222613","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Confirming anthropogenic influences on the major organic and inorganic constituents of rainwater in an urban area 确定城市地区雨水主要有机和无机成分的人为影响
Drinking Water Engineering and Science Pub Date : 2015-11-03 DOI: 10.5194/DWES-8-35-2015
K. Chon, Young-Mo Kim, D. Bae, Jaeweon Cho
{"title":"Confirming anthropogenic influences on the major organic and inorganic constituents of rainwater in an urban area","authors":"K. Chon, Young-Mo Kim, D. Bae, Jaeweon Cho","doi":"10.5194/DWES-8-35-2015","DOIUrl":"https://doi.org/10.5194/DWES-8-35-2015","url":null,"abstract":"Abstract. Recently, rainwater composition affected by atmospheric pollutants has been the topic of intense study in East Asia because of its adverse environmental and human health effects. In the present study, the chemical composition and organic compounds of rainwater were investigated from June to December 2012 at Gwangju in Korea. The aim of this study is to determine the seasonal variation of rainwater chemical composition and to identify possible sources of inorganic and organic compounds. The volume-weighted mean of pH ranged from 3.83 to 8.90 with an average of 5.78. Of rainwater samples, 50 % had pH values below 5.6. The volume-weighted mean concentration (VWMC) of major ions followed the order Cl− > SO42− > NH4+ > Na+ > NO3− > Ca2+ > Mg2+ > K+. The VWMC of trace metals decreased in the order Zn > Al > Fe > Mn > Pb > Cu > Ni > Cd > Cr. The VWMCs of major ions and trace metals were higher in winter than in summer. The high enrichment factors indicate that Zn, Pb, Cu, and Cd originated predominantly from anthropogenic sources. Factor analysis (principal component analysis) indicates the influence of anthropogenic pollutants, sea salt, and crustal materials on the chemical compositions of rainwater. Benzoic acids, 1H-isoindole-1,3(2H)-dione, phthalic anhydride, benzene, acetic acids, 1,2-benzenedicarboxylic acids, benzonitrile, acetaldehyde, and acetamide were the most prominent pyrolysis fragments for rainwater organic compounds identified by pyrolysis gas chromatography/mass spectrometry (Py-GC/MS). The results indicate that anthropogenic sources are the most important factors affecting the organic composition of rainwater in an urban area.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"8 1","pages":"35-48"},"PeriodicalIF":0.0,"publicationDate":"2015-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71222775","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 17
Conversion of organic micropollutants with limited bromate formation during the Peroxone process in drinking water treatment 饮用水处理中Peroxone过程中溴酸盐形成有限的有机微污染物的转化
Drinking Water Engineering and Science Pub Date : 2015-09-17 DOI: 10.5194/DWES-8-25-2015
A. H. Knol, K. Lekkerkerker-Teunissen, C. Houtman, J. Scheideler, A. Ried, J. V. Dijk
{"title":"Conversion of organic micropollutants with limited bromate formation during the Peroxone process in drinking water treatment","authors":"A. H. Knol, K. Lekkerkerker-Teunissen, C. Houtman, J. Scheideler, A. Ried, J. V. Dijk","doi":"10.5194/DWES-8-25-2015","DOIUrl":"https://doi.org/10.5194/DWES-8-25-2015","url":null,"abstract":"Advanced oxidation with O3 / H2O2 (peroxone) was conducted on pilot plant scale on pre-treated Meuse river water to investigate the conversion of organic micropollutants (OMPs) and the formation of bromate. Fourteen selected model compounds were dosed to the pre-treated river water on a regular basis to assess the efficiency of the peroxone process and to establish the influence of the water matrix. The ozone dose was the main factor in the conversion of the model compounds, however, the ozone dose was limited because of bromate formation. The hydrogen peroxide dosage had only a minor effect on the conversion, but it limited the bromate formation effectively. In terms of limited chemical consumption, maximal conversion and to comply the strict Dutch drinking water act for bromate of 1 ?g L?1, a practical peroxone setting was 6 mg L?1 hydrogen peroxide and 1.5 mg L?1 ozone. During the investigation period, the average conversion of the model compounds was 78.9 %. The conversion of OMPs was higher at higher water temperatures and lower concentrations of DOC and bicarbonate. The bromate formation also was higher at higher water temperature and lower bicarbonate concentration and proportional with the bromide concentration, above a threshold of about 32 ?g L?1 bromide. The peroxone process can be controlled on basis of the (derived) parameters water temperature, bicarbonate and DOC.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"8 1","pages":"25-34"},"PeriodicalIF":0.0,"publicationDate":"2015-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"71222693","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信