Prosthesis最新文献

筛选
英文 中文
Lithium Silicate-Based Glass Ceramics in Dentistry: A Narrative Review 硅酸锂基玻璃陶瓷在牙科中的应用:叙述性综述
Prosthesis Pub Date : 2024-05-02 DOI: 10.3390/prosthesis6030034
H. Al-Johani, J. Haider, Julian Satterthwaite, N. Silikas
{"title":"Lithium Silicate-Based Glass Ceramics in Dentistry: A Narrative Review","authors":"H. Al-Johani, J. Haider, Julian Satterthwaite, N. Silikas","doi":"10.3390/prosthesis6030034","DOIUrl":"https://doi.org/10.3390/prosthesis6030034","url":null,"abstract":"Considering the rapid evolution of lithium silicate-based glass ceramics (LSCs) in dentistry, this review paper aims to present an updated overview of the recently introduced commercial novel LSCs. The clinical and in vitro English-language literature relating to the microstructure, manufacturing, strengthening, properties, surface treatments and clinical performance of LSC materials was obtained through an electronic search. Findings from relevant articles were extracted and summarised for this manuscript. There is considerable evidence supporting the mechanical and aesthetic competency of LSC variants, namely zirconia-reinforced lithium silicates and lithium–aluminium disilicates. Nonetheless, the literature assessing the biocompatibility and cytotoxicity of novel LSCs is scarce. An exploration of the chemical, mechanical and chemo-mechanical intaglio surface treatments—alternative to hydrofluoric acid etching—revealed promising adhesion performance for acid neutralisation and plasma treatment. The subtractive manufacturing methods of partially crystallised and fully crystallised LSC blocks and the additive manufacturing modalities pertaining to the fabrication of LSC dental restorations are addressed, wherein that challenges that could be encountered upon implementing novel additive manufacturing approaches using LSC print materials are highlighted. Furthermore, the short-term clinical performance of zirconia-reinforced lithium silicates and lithium–aluminium disilicates is demonstrated to be comparable to that of lithium disilicate ceramics and reveals promising potential for their long-term clinical performance.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"19 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"141018485","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Evaluating Angled Abutments: Three-Dimensional Finite Element Stress Analysis of Anterior Maxillary Implants 评估成角基台:上颌前牙种植体的三维有限元应力分析
Prosthesis Pub Date : 2024-03-25 DOI: 10.3390/prosthesis6020024
C. K N, Afiya Eram, N. Shetty, Divya D. Shetty, Mohan Futane, Laxmikant G. Keni
{"title":"Evaluating Angled Abutments: Three-Dimensional Finite Element Stress Analysis of Anterior Maxillary Implants","authors":"C. K N, Afiya Eram, N. Shetty, Divya D. Shetty, Mohan Futane, Laxmikant G. Keni","doi":"10.3390/prosthesis6020024","DOIUrl":"https://doi.org/10.3390/prosthesis6020024","url":null,"abstract":"Restorative dentistry is the repairing of damaged teeth and restoring oral health and function. Dental implants are typically placed within the cortical bone of the jaw to provide stability and support for prosthetic restorations. The successful restoration of complex anatomical features of the maxillary anterior is difficult for prosthodontists. Using a 3D slicer, CT scan images were used to create a detailed three-dimensional model of the maxilla bone. This study utilizes ANSYS Workbench, a finite element software program, to analyze the abutment angles, ranging from 0° to 25°, and the impact stress distribution within peri-implant bone. The outcomes of our studies align with and substantiate certain evidence in the literature documenting bone resorption, specifically at the level of the implant neck and near the cortical bone. The study aims to provide a comprehensive understanding of angled abutment stress patterns in the bone surrounding dental implants, offering valuable insights for clinical applications in critical areas of the mouth.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":" 8","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140384378","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Exploring Stresses in Mandibular Jawbone during Implant Insertion: A Three-Dimensional Explicit Dynamic Analysis 探索植入假牙过程中下颌骨的应力:三维显性动态分析
Prosthesis Pub Date : 2024-03-25 DOI: 10.3390/prosthesis6020023
C. K N, Afiya Eram, N. Shetty, Divya D. Shetty, Mohan Futane, Laxmikant G. Keni
{"title":"Exploring Stresses in Mandibular Jawbone during Implant Insertion: A Three-Dimensional Explicit Dynamic Analysis","authors":"C. K N, Afiya Eram, N. Shetty, Divya D. Shetty, Mohan Futane, Laxmikant G. Keni","doi":"10.3390/prosthesis6020023","DOIUrl":"https://doi.org/10.3390/prosthesis6020023","url":null,"abstract":"In dental implant insertion, an artificial foundation is prepared for the prosthetic device, which involves the surgical positioning of the implant in the jaw bone. The success of dental implants relies on the osseointegration process. The biomechanical factors, such as stress and strain, developed during the insertion affect the jawbone and its surroundings. In this current study, the stresses during the implant insertion in the mandibular jawbone bone are analyzed using three-dimensional explicit dynamic analysis, and the Cowper–Symonds model is implemented with the damage model. The implant’s design has a substantial impact on stress distribution within the cancellous bone during the insertion procedure. The stress variation takes place as the implant moves into the pre-drilled hole. This is because of the contact between the bone and the fixture on the implant. The upper edge of the predrilled site shows that the stresses are more at the crestal region of the implant due to surface area. There is a gradual increase in the stress level as the implant reaches the lower edge from the top edge. This is because of the concept of mechanical interlocking. Clinicians can use this information to anticipate and address potential stress-related challenges during implant placement.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":" 611","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140383086","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Extensometry Study of the Most Appropriate Position and Arrangement of Stress-Breaker Bridges with Pier Abutment 墩式桥台应力消除桥最合适位置和布置的伸长测量研究
Prosthesis Pub Date : 2024-02-21 DOI: 10.3390/prosthesis6020017
Carolina Barletta del Campo, J. Gracia Rodríguez, G. Fidalgo Valverde, F. S. Sánchez Lasheras
{"title":"Extensometry Study of the Most Appropriate Position and Arrangement of Stress-Breaker Bridges with Pier Abutment","authors":"Carolina Barletta del Campo, J. Gracia Rodríguez, G. Fidalgo Valverde, F. S. Sánchez Lasheras","doi":"10.3390/prosthesis6020017","DOIUrl":"https://doi.org/10.3390/prosthesis6020017","url":null,"abstract":"The arrangement of a stress breaker in the pier abutment of a fixed-mobile bridge affects the deformations that may occur in its supports. This article aims to study the most appropriate position and arrangement of a stress breaker. To verify the established objectives, an experimental “in vitro” study was carried out with five different bridge designs: one with rigid connectors and four with non-rigid connectors (interlocks), placed on the distal and mesial surface of the intermediate abutment, and combining the retention stop at cervical and occlusal positions. The strain level at the support ground of each bridge was measured with strain gauges. The statistical analysis was performed with the help of the Kruskal–Wallis test and a linear regression model. Initial results show that the model with the highest average value of maximum strain is the non-rigid bridge with the interlock on the distal surface of the pier abutment and the occlusal retention stop. In any case, the presence of an intermediate abutment, with or without interlock, influences the maximum tension supported by the abutment, especially in relation to the intermediate abutment.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"26 4","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140443081","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Use of a Surgical Template for the Insertion of Dental Implants and Sinus Lift with the Summers Technique Based on Digital Planning: A Case Report 使用基于数字规划的萨默斯技术的手术模板植入牙种植体和上颌窦提升术:病例报告
Prosthesis Pub Date : 2024-02-14 DOI: 10.3390/prosthesis6010016
Stefano Speroni, Floriana Bosco, Francesco Ferrini, Laura Pittari, A. Nota, Simona Tecco
{"title":"The Use of a Surgical Template for the Insertion of Dental Implants and Sinus Lift with the Summers Technique Based on Digital Planning: A Case Report","authors":"Stefano Speroni, Floriana Bosco, Francesco Ferrini, Laura Pittari, A. Nota, Simona Tecco","doi":"10.3390/prosthesis6010016","DOIUrl":"https://doi.org/10.3390/prosthesis6010016","url":null,"abstract":"(1) Background: Computer-guided surgery is now established as the main technique for implant placement, reducing intraoperative complications and helping the clinician avoid damaging sensitive anatomical structures, such as, for example, the maxillary sinus. (2) Methods: A complex case is discussed to suggest how computer-aided surgery can merge with freehand surgery, as a surgical guide can make a freehand surgical procedure less complicated and more predictable. (3) Results: A surgical procedure was executed following digital planning, except for sites 1.5 and 2.5, where a mixed approach was adopted: they were initially prepared with a milling depth of 1 mm from the base of the maxillary sinus and were then finished using osteotomes, according to the technique described by Summers. Radiography confirmed the correct positioning of the implants and the sinus lift. (4) Conclusions: A mixed digital/analogical approach used in complex cases increases the accuracy of the results and reduces complications and treatment time. The presence of a correctly digitally planned surgical guide helps in the freehand approach and not only in the digital approach.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"52 7","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139779043","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of Different Dental Implant Prosthetic Joints on Marginal Bone Loss: Emerging Findings from a Bayesian Network Meta-Analysis (NMA) and Systematic Review 不同种植牙修复关节对边缘骨质流失的影响:贝叶斯网络 Meta 分析 (NMA) 和系统综述的新发现
Prosthesis Pub Date : 2024-02-14 DOI: 10.3390/prosthesis6010015
F. Lorusso, I. Alla, S. Gehrke, Mariastella Di Carmine, Sergio Rexhep Tari, A. Scarano
{"title":"Effect of Different Dental Implant Prosthetic Joints on Marginal Bone Loss: Emerging Findings from a Bayesian Network Meta-Analysis (NMA) and Systematic Review","authors":"F. Lorusso, I. Alla, S. Gehrke, Mariastella Di Carmine, Sergio Rexhep Tari, A. Scarano","doi":"10.3390/prosthesis6010015","DOIUrl":"https://doi.org/10.3390/prosthesis6010015","url":null,"abstract":"Background: A key point in assessing dental implant prosthetic joints is their mechanical strength and biological response under the masticatory loading. The aim of the present systematic review was to evaluate the marginal bone loss and prosthetic behaviour of different internal/external bi-phasic implants. Methods: Randomized Clinical Trials (RCTs) have been considered for analytic purposes. The article screening was conducted on the Pubmed/MEDLINE, EMBASE and Google Scholars databases through an electronic process. Eligibility and risk of bias assessments were conducted for an article to be included in the data process. A series of pairwise meta-regressions for continuous variables was conducted considering the mean differences and 95% CI at two different timepoints: baseline and 1-year follow-up. The meta-analysis was performed comparing the following groups: internal conical prosthetic joint with index (IC), external hexagon bone level position (EI), internal tri-channel connection bone level position (ITC), internal hexagon 1 mm below the bone level (HI), internal hexagon bone level position (HI crest), cone morse 1 mm below the bone level (CM), cone morse bone level position (CM crest) and internal octagon bone level position (IO). The following parameters were considered for descriptive data synthesis: sample size, implant manufacturer, prosthetic joint type, prosthetic complications, marginal bone loss, study outcomes. Results: A total of 247 papers were identified by the electronic screening and 241 were submitted for the full text assessment. The eligibility process excluded 209 articles, and 32 studies with a low risk of bias were considered for the qualitative synthesis and further statistical methods. At the baseline, the CM showed a more effective efficiency and reduced marginal bone loss compared to IC, EI, ITC, internal hexagon, cone morse and internal octagon (p < 0.05). CM showed the lower rate of prosthetic complications and structural device failure including abutments and joint components under the loading compared to other joint types. Conclusion: Within the limits of the present investigation, the heterogeneity, the weight of the study model considered and the inherent differences between the dental implant properties, the pure CM showed a more consistent control of marginal bone loss at short- and medium-term follow-up. Despite the low rate of cumulative complications for all joints considered, the CM abutment joints were less prone to prosthetic failure at an early and medium-term follow-up.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"290 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139837818","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Effect of Different Dental Implant Prosthetic Joints on Marginal Bone Loss: Emerging Findings from a Bayesian Network Meta-Analysis (NMA) and Systematic Review 不同种植牙修复关节对边缘骨质流失的影响:贝叶斯网络 Meta 分析 (NMA) 和系统综述的新发现
Prosthesis Pub Date : 2024-02-14 DOI: 10.3390/prosthesis6010015
F. Lorusso, I. Alla, S. Gehrke, Mariastella Di Carmine, Sergio Rexhep Tari, A. Scarano
{"title":"Effect of Different Dental Implant Prosthetic Joints on Marginal Bone Loss: Emerging Findings from a Bayesian Network Meta-Analysis (NMA) and Systematic Review","authors":"F. Lorusso, I. Alla, S. Gehrke, Mariastella Di Carmine, Sergio Rexhep Tari, A. Scarano","doi":"10.3390/prosthesis6010015","DOIUrl":"https://doi.org/10.3390/prosthesis6010015","url":null,"abstract":"Background: A key point in assessing dental implant prosthetic joints is their mechanical strength and biological response under the masticatory loading. The aim of the present systematic review was to evaluate the marginal bone loss and prosthetic behaviour of different internal/external bi-phasic implants. Methods: Randomized Clinical Trials (RCTs) have been considered for analytic purposes. The article screening was conducted on the Pubmed/MEDLINE, EMBASE and Google Scholars databases through an electronic process. Eligibility and risk of bias assessments were conducted for an article to be included in the data process. A series of pairwise meta-regressions for continuous variables was conducted considering the mean differences and 95% CI at two different timepoints: baseline and 1-year follow-up. The meta-analysis was performed comparing the following groups: internal conical prosthetic joint with index (IC), external hexagon bone level position (EI), internal tri-channel connection bone level position (ITC), internal hexagon 1 mm below the bone level (HI), internal hexagon bone level position (HI crest), cone morse 1 mm below the bone level (CM), cone morse bone level position (CM crest) and internal octagon bone level position (IO). The following parameters were considered for descriptive data synthesis: sample size, implant manufacturer, prosthetic joint type, prosthetic complications, marginal bone loss, study outcomes. Results: A total of 247 papers were identified by the electronic screening and 241 were submitted for the full text assessment. The eligibility process excluded 209 articles, and 32 studies with a low risk of bias were considered for the qualitative synthesis and further statistical methods. At the baseline, the CM showed a more effective efficiency and reduced marginal bone loss compared to IC, EI, ITC, internal hexagon, cone morse and internal octagon (p < 0.05). CM showed the lower rate of prosthetic complications and structural device failure including abutments and joint components under the loading compared to other joint types. Conclusion: Within the limits of the present investigation, the heterogeneity, the weight of the study model considered and the inherent differences between the dental implant properties, the pure CM showed a more consistent control of marginal bone loss at short- and medium-term follow-up. Despite the low rate of cumulative complications for all joints considered, the CM abutment joints were less prone to prosthetic failure at an early and medium-term follow-up.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"45 12","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139777961","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The Use of a Surgical Template for the Insertion of Dental Implants and Sinus Lift with the Summers Technique Based on Digital Planning: A Case Report 使用基于数字规划的萨默斯技术的手术模板植入牙种植体和上颌窦提升术:病例报告
Prosthesis Pub Date : 2024-02-14 DOI: 10.3390/prosthesis6010016
Stefano Speroni, Floriana Bosco, Francesco Ferrini, Laura Pittari, A. Nota, Simona Tecco
{"title":"The Use of a Surgical Template for the Insertion of Dental Implants and Sinus Lift with the Summers Technique Based on Digital Planning: A Case Report","authors":"Stefano Speroni, Floriana Bosco, Francesco Ferrini, Laura Pittari, A. Nota, Simona Tecco","doi":"10.3390/prosthesis6010016","DOIUrl":"https://doi.org/10.3390/prosthesis6010016","url":null,"abstract":"(1) Background: Computer-guided surgery is now established as the main technique for implant placement, reducing intraoperative complications and helping the clinician avoid damaging sensitive anatomical structures, such as, for example, the maxillary sinus. (2) Methods: A complex case is discussed to suggest how computer-aided surgery can merge with freehand surgery, as a surgical guide can make a freehand surgical procedure less complicated and more predictable. (3) Results: A surgical procedure was executed following digital planning, except for sites 1.5 and 2.5, where a mixed approach was adopted: they were initially prepared with a milling depth of 1 mm from the base of the maxillary sinus and were then finished using osteotomes, according to the technique described by Summers. Radiography confirmed the correct positioning of the implants and the sinus lift. (4) Conclusions: A mixed digital/analogical approach used in complex cases increases the accuracy of the results and reduces complications and treatment time. The presence of a correctly digitally planned surgical guide helps in the freehand approach and not only in the digital approach.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"133 3","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139838879","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Risk of Bleeding in Elderly Patients Undergoing Transcatheter Aortic Valve Implantation or Surgical Aortic Valve Replacement 接受经导管主动脉瓣植入术或主动脉瓣置换术的老年患者的出血风险
Prosthesis Pub Date : 2024-02-12 DOI: 10.3390/prosthesis6010014
F. Jiritano, G. Serraino, S. Sorrentino, Desirèe Napolitano, David Costa, Nicola Ielapi, U. Bracale, P. Mastroroberto, M. Andreucci, R. Serra
{"title":"Risk of Bleeding in Elderly Patients Undergoing Transcatheter Aortic Valve Implantation or Surgical Aortic Valve Replacement","authors":"F. Jiritano, G. Serraino, S. Sorrentino, Desirèe Napolitano, David Costa, Nicola Ielapi, U. Bracale, P. Mastroroberto, M. Andreucci, R. Serra","doi":"10.3390/prosthesis6010014","DOIUrl":"https://doi.org/10.3390/prosthesis6010014","url":null,"abstract":"Background: Bleeding complications are strong predictors of mortality and major morbidity in elderly patients undergoing surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI). Despite the high prevalence of frailty in this population, little is known about its effects on bleeding risk. Methods: We conducted a retrospective observational study of 502 patients undergoing isolated SAVR or TAVI between January 2015 and February 2022. The occurrence of blood products transfusions and MACEs were the primary endpoints. In-hospital mortality was the secondary endpoint. Results: The Elderly group (age < 80 years old) included 475 subjects, whereas the Very Elderly group (age ≥ 80 years old) included 127 patients. The need for blood product transfusion was similar among the two groups, regardless of the type of procedure. MACEs occurred similarly between groups [SAVR: Elderly group: 7.9% vs. Very Elderly group: 8.6%, p = 0.864; TAVI: Elderly group: 5.5% vs. Very Elderly group: 8.7%, p = 0.378]. The was no difference in in-hospital mortality rate in patients submitted to TAVI, whereas very elderly patients had higher mortality rate compared to the elderly patients submitted to SAVR [SAVR: Elderly group: 0% vs. Very Elderly group: 2.8%, p = 0.024; TAVI: Elderly group: 4,8% vs. Very Elderly group: 8%, p = 0.389]. Conclusions: Age alone should not be considered as a predictive factor for post-operative adverse events or in-hospital mortality in elderly patients with severe symptomatic AS.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"156 ","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139842343","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Risk of Bleeding in Elderly Patients Undergoing Transcatheter Aortic Valve Implantation or Surgical Aortic Valve Replacement 接受经导管主动脉瓣植入术或主动脉瓣置换术的老年患者的出血风险
Prosthesis Pub Date : 2024-02-12 DOI: 10.3390/prosthesis6010014
F. Jiritano, G. Serraino, S. Sorrentino, Desirèe Napolitano, David Costa, Nicola Ielapi, U. Bracale, P. Mastroroberto, M. Andreucci, R. Serra
{"title":"Risk of Bleeding in Elderly Patients Undergoing Transcatheter Aortic Valve Implantation or Surgical Aortic Valve Replacement","authors":"F. Jiritano, G. Serraino, S. Sorrentino, Desirèe Napolitano, David Costa, Nicola Ielapi, U. Bracale, P. Mastroroberto, M. Andreucci, R. Serra","doi":"10.3390/prosthesis6010014","DOIUrl":"https://doi.org/10.3390/prosthesis6010014","url":null,"abstract":"Background: Bleeding complications are strong predictors of mortality and major morbidity in elderly patients undergoing surgical aortic valve replacement (SAVR) or transcatheter aortic valve implantation (TAVI). Despite the high prevalence of frailty in this population, little is known about its effects on bleeding risk. Methods: We conducted a retrospective observational study of 502 patients undergoing isolated SAVR or TAVI between January 2015 and February 2022. The occurrence of blood products transfusions and MACEs were the primary endpoints. In-hospital mortality was the secondary endpoint. Results: The Elderly group (age < 80 years old) included 475 subjects, whereas the Very Elderly group (age ≥ 80 years old) included 127 patients. The need for blood product transfusion was similar among the two groups, regardless of the type of procedure. MACEs occurred similarly between groups [SAVR: Elderly group: 7.9% vs. Very Elderly group: 8.6%, p = 0.864; TAVI: Elderly group: 5.5% vs. Very Elderly group: 8.7%, p = 0.378]. The was no difference in in-hospital mortality rate in patients submitted to TAVI, whereas very elderly patients had higher mortality rate compared to the elderly patients submitted to SAVR [SAVR: Elderly group: 0% vs. Very Elderly group: 2.8%, p = 0.024; TAVI: Elderly group: 4,8% vs. Very Elderly group: 8%, p = 0.389]. Conclusions: Age alone should not be considered as a predictive factor for post-operative adverse events or in-hospital mortality in elderly patients with severe symptomatic AS.","PeriodicalId":506748,"journal":{"name":"Prosthesis","volume":"45 20","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"139782482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信