International Journal of Prosthodontics最新文献

筛选
英文 中文
Clinical Outcomes of Metal-Ceramic versus Metal-Acrylic Resin Implant-Supported Fixed Complete Dental Prostheses: A Systematic Review and Meta-analysis. 金属-陶瓷与金属-丙烯酸树脂种植体支持的固定全牙修复体的临床结果:系统回顾和荟萃分析。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-05-01 DOI: 10.11607/ijp.7592
Nathan Estrin, Kyung Nam, Georgios E Romanos, Jamie Saragossi, Vincent J Iacono, Seyed Hossein Bassir
{"title":"Clinical Outcomes of Metal-Ceramic versus Metal-Acrylic Resin Implant-Supported Fixed Complete Dental Prostheses: A Systematic Review and Meta-analysis.","authors":"Nathan Estrin,&nbsp;Kyung Nam,&nbsp;Georgios E Romanos,&nbsp;Jamie Saragossi,&nbsp;Vincent J Iacono,&nbsp;Seyed Hossein Bassir","doi":"10.11607/ijp.7592","DOIUrl":"https://doi.org/10.11607/ijp.7592","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the clinical outcomes of metal-ceramic vs metal-acrylic resin implant-supported fixed complete denture prostheses (IFCDPs).</p><p><strong>Materials and methods: </strong>An electronic literature database search was conducted in the CINAHL, EMBASE, PubMed, and Web of Science databases. Additionally, a manual search of the literature was performed. Studies conducted in edentulous human subjects comparing clinical outcomes of metal-acrylic resin IFCDPs to those of metal-ceramic IFCDPs were included if quantitative outcomes for the following variables were reported: implant failure, prosthetic failure, incidence of peri-implantitis, incidence of peri-implant mucositis, incidence of peri-implant mucosal recession, prosthetic complications, and any patient-centered outcomes. Data from included studies were pooled to estimate effect size.</p><p><strong>Results: </strong>Five studies met the inclusion criteria. A quantitative analysis was possible for risk of implant failure, prosthesis failure, and incidence of peri-implantitis. Meta-analysis showed no statistically significant differences in the risk of implant or prosthesis failure between the two groups. However, meta-analysis showed a significantly greater risk of developing peri-implantitis at the implant level in the metal-acrylic group when compared to the metal-ceramic group (risk difference = 0.069; 95% CI = 0.028 to 0.06; P = .001; fixed-effects model). Furthermore, descriptive analysis of the literature indicated a higher incidence of other biologic complications such as peri-implant mucositis and peri-implant mucosal recession, as well as prosthetic complications such as abrasion and veneer fracture, in metal-acrylic resin IFCDPs compared to metal-ceramic IFCDPs.</p><p><strong>Conclusion: </strong>The available evidence suggests that a higher incidence of biologic and prosthetic complications, including a higher risk of peri-implantitis, are present with metal-acrylic resin IFCDPs compared to metal-ceramic IFCDPs.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"354–365"},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10091813","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Evaluating the Accuracy of Dental Restorations Manufactured by Two CAD/CAM Milling Systems and Their Prototypes Fabricated by 3D Printing Methods: An In Vitro Study 评估两种CAD/CAM铣削系统制造的牙修复体及其3D打印方法制造的原型的准确性:一项体外研究
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-05-01 DOI: 10.11607/ijp.7633
Ali Alenezi, Mohammed Yehya
{"title":"Evaluating the Accuracy of Dental Restorations Manufactured by Two CAD/CAM Milling Systems and Their Prototypes Fabricated by 3D Printing Methods: An In Vitro Study","authors":"Ali Alenezi,&nbsp;Mohammed Yehya","doi":"10.11607/ijp.7633","DOIUrl":"https://doi.org/10.11607/ijp.7633","url":null,"abstract":"<p><strong>Purpose: </strong>This in vitro study was conducted to evaluate the marginal accuracy of all-ceramic onlay restorations and prototypes fabricated using additive and subtractive methods.</p><p><strong>Materials and methods: </strong>Ten typodont first molars were prepared and scanned two times using two different scanners: ARCTICA AutoScan (KaVo Dental) and CEREC Omnicam (Dentsply Sirona). The two groups of virtual models were used to design two groups of virtual onlay restorations using two different CAD software (n = 10 each group) and exported in STL files. Each group of STL files was converted to physical onlay restorations and prototypes by using three different methods; these included two additive manufacturing techniques, stereolithography apparatus (SLA) and digital light processing (DLP), and one subtractive technique, e.max milling using the KaVo Everest system and the Dentsply Sirona inLab MC X5. A digital microscope was used to evaluate the marginal fit around the onlay restorations or prototypes on the typodont teeth.</p><p><strong>Results: </strong>All evaluated groups showed mean marginal gaps between 59 and 84 µm. No statistically significant differences were found when comparing the marginal accuracy of onlay restorations fabricated by the subtractive method and onlay prototypes from the two additive methods, SLA (P = .70) and DLP (P = .21).</p><p><strong>Conclusion: </strong>All the models evaluated produced marginal gaps within the reported acceptable clinical range. Thus, these subtractive and additive methods may be considered suitable for onlay restoration production.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"293-300"},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10129052","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Fracture Load of Veneered and Monolithic Single-Unit Fixed Dental Prostheses Made from the High-Performance Thermoplastic Polyphenylene Sulfone 高性能热塑性聚苯砜贴面和整体单单元固定义齿的断裂载荷研究
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-05-01 DOI: 10.11607/ijp.7675
Felicitas Mayinger, Marlis Eichberger, Lisa Marie Schönhoff, Bogna Stawarczyk
{"title":"Fracture Load of Veneered and Monolithic Single-Unit Fixed Dental Prostheses Made from the High-Performance Thermoplastic Polyphenylene Sulfone","authors":"Felicitas Mayinger,&nbsp;Marlis Eichberger,&nbsp;Lisa Marie Schönhoff,&nbsp;Bogna Stawarczyk","doi":"10.11607/ijp.7675","DOIUrl":"https://doi.org/10.11607/ijp.7675","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the fracture load of different veneers for monolithic single-unit fixed dental prostheses (FDPs) made of a novel potential framework material, polyphenylene sulfone (PPSU).</p><p><strong>Materials and methods: </strong>The fracture loads of four PPSU frameworks with different veneers (manual polymer veneer with Ceramage Body A3B; prefabricated polymer veneer with Novo.lign; digital polymer veneer with Telio CAD; digital ceramic veneer with IPS Empress CAD) and a monolithic control group (PPSU, Gehr) were examined initially and after 1,200,000 masticatory (50 N, 1.3 Hz) and 6,000 thermal cycles (5°C/55°C). Fracture analysis was performed using light microscope imaging. Fracture types were classified, and relative frequencies were determined. Univariate analysis of variance, post hoc Scheffé, partial eta squared, Kruskal-Wallis test, and Weibull moduli using the maximum likelihood estimation method were calculated. The defined level of significance was adjusted by Bonferroni correction (P < .005).</p><p><strong>Results: </strong>Aging did not affect the fracture load values. Single-unit FDPs with a digital ceramic veneer showed lower values than monolithic and manual polymer-veneer specimens. Single-unit FDPs with a prefabricated and digital polymer veneer were in the same value range as specimens with a manual polymer and digital ceramic veneer. No differences were observed between manual polymer veneer and monolithic single-unit FDPs. All veneered specimens showed a fracture of the veneer. For monolithic single-unit FDPs, a plastic deformation was observed.</p><p><strong>Conclusion: </strong>Veneered and monolithic PPSU showed sufficient fracture load values to indicate successful clinical use in single-unit FDPs. The choice of veneering method and material may play a minor role.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"343–353"},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9727009","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Soft Loading Protocol of Short Strategic Implants in Posterior Mandibles Supporting Removable Bilateral Free-End Prostheses: 1-year Results of a Prospective Cohort Study. 后下颌短战略种植体软加载方案支持可移动双侧游离端假体:1年前瞻性队列研究结果。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-05-01 DOI: 10.11607/ijp.7827
Norbert Enkling, Thanuja Thanendrarajah, Ayse Mathey, Simone Janner, Martin Schimmel, Samir Abou-Ayash
{"title":"Soft Loading Protocol of Short Strategic Implants in Posterior Mandibles Supporting Removable Bilateral Free-End Prostheses: 1-year Results of a Prospective Cohort Study.","authors":"Norbert Enkling,&nbsp;Thanuja Thanendrarajah,&nbsp;Ayse Mathey,&nbsp;Simone Janner,&nbsp;Martin Schimmel,&nbsp;Samir Abou-Ayash","doi":"10.11607/ijp.7827","DOIUrl":"https://doi.org/10.11607/ijp.7827","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate 1-year survival and success rates of 6-mm short implants placed in mandibular molar sites with two different abutments (dome/ball) retaining existing removable partial dentures (RPDs).</p><p><strong>Materials and methods: </strong>In 19 patients, 38 implants of 6-mm length were placed bilaterally. After 4 months, each participant received the dome abutment, which 2 months later was exchanged with the ball abutment. Clinical data were recorded at abutment connection (4 months postsurgery) and at 6 and 12 months postsurgery, including probing depth, bleeding on probing, presence of plaque, and standardized radiographs. Implant success was assessed using the following criteria: presence of pain, mobility, radiographic bone loss, probing depth, and the presence of exudate. For descriptive analyses, mean and SD values were calculated. Paired sample t tests and linear regressions with a significance level of α < .05 were applied to analyze the evolution of peri-implant parameters and the influence of implant placement depth.</p><p><strong>Results: </strong>The overall mean marginal bone level alteration (DMBL) was 1.05 ± 0.69 mm. A statistically significant marginal bone loss over time was observed at the mesial and distal aspects of all implants (P < .05). The implant survival rate was 100%. No implants showed pain, exudate, mobility, or probing depth > 7 mm. Three implants were classified as having satisfactory survival due to a DMBL > 2 mm (resulting success rate: 92.1%). No influence of implant placement depth was found.</p><p><strong>Conclusion: </strong>These short-term results suggest that short implants can be used in mandibular molar sites for additional posterior support of free-end RPDs. However, in individual cases, DMBL > 2 mm may occur.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"282–292"},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9727575","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Facially Driven Rehabilitation of a Cleft Lip and Palate Patient with an Implant-Supported Complete Fixed Dental Prosthesis: Outcome of a Multidisciplinary Approach. 唇腭裂患者采用种植体支持的完全固定义齿的面部驱动康复:多学科方法的结果。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-05-01 DOI: 10.11607/ijp.7622
Jose M Reuss, Debora Reuss, Luc Rutten, Patrick Rutten, Borja Mateo, Beatriz R Vilaboa, Debora R Vilaboa
{"title":"Facially Driven Rehabilitation of a Cleft Lip and Palate Patient with an Implant-Supported Complete Fixed Dental Prosthesis: Outcome of a Multidisciplinary Approach.","authors":"Jose M Reuss,&nbsp;Debora Reuss,&nbsp;Luc Rutten,&nbsp;Patrick Rutten,&nbsp;Borja Mateo,&nbsp;Beatriz R Vilaboa,&nbsp;Debora R Vilaboa","doi":"10.11607/ijp.7622","DOIUrl":"https://doi.org/10.11607/ijp.7622","url":null,"abstract":"<p><p>Patients with a facial malformation due to a cleft lip and palate (CLP) usually suffer from a reduced ability to function normally associated with a poor oral health-related quality of life. This condition often requires multiple significant surgical interventions, and the prosthetic restoration, when needed, is not always included in the initial treatment plan. In order to obtain the highest possible degree of functional, occlusal, and phonetic performance, as well as esthetics, a facially guided prosthodontic treatment sequence should be established. The case presented in this publication shows a multidisciplinary approach for reconstruction of a compromised maxilla with an implant-supported prosthesis via a minimally invasive, digitalized approach.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"375-385"},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9792959","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Laboratory Evaluation of Production Efficiency for Removable Partial Denture Frameworks Using In-House Casting vs Outsourced Additive Manufacturing Techniques 使用内部铸造与外包增材制造技术的可移动局部义齿框架生产效率的实验室评估
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-05-01 DOI: 10.11607/ijp.7132
Zaid Ali, Duncan Wood, Abdulrahman Elmougy, Paul Kelleher, Nicolas Martin
{"title":"Laboratory Evaluation of Production Efficiency for Removable Partial Denture Frameworks Using In-House Casting vs Outsourced Additive Manufacturing Techniques","authors":"Zaid Ali,&nbsp;Duncan Wood,&nbsp;Abdulrahman Elmougy,&nbsp;Paul Kelleher,&nbsp;Nicolas Martin","doi":"10.11607/ijp.7132","DOIUrl":"https://doi.org/10.11607/ijp.7132","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the production efficiency of selective laser sintering (SLS) to traditional casting for the fabrication of metal prosthodontic frameworks in a prospective pilot evaluation in a hospital prosthodontic laboratory setting.</p><p><strong>Materials and methods: </strong>The time taken to complete each of the identified stages in the production of 50 removable partial denture frameworks made using either SLS (n = 25) or casting (n = 25) workflows was measured. The mean time for production was calculated for each workflow, and the difference was tested for statistical significance.</p><p><strong>Results/conclusion: </strong>The results indicate that an SLS workflow may be more time-efficient, and further cost-effectiveness research is indicated.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"338-342"},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9808065","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Food Solutions and Cigarette Smoke-Dependent Changes in Color and Surface Texture of CAD/CAM Composite Resins-An In Vitro Study. 食品溶液和香烟烟雾对CAD/CAM复合树脂颜色和表面纹理变化的体外研究。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-05-01 DOI: 10.11607/ijp.6950
Marcel Reymus, Anja Liebermann, Sebastian Spintzyk, Bogna Stawarczyk
{"title":"Food Solutions and Cigarette Smoke-Dependent Changes in Color and Surface Texture of CAD/CAM Composite Resins-An In Vitro Study.","authors":"Marcel Reymus,&nbsp;Anja Liebermann,&nbsp;Sebastian Spintzyk,&nbsp;Bogna Stawarczyk","doi":"10.11607/ijp.6950","DOIUrl":"https://doi.org/10.11607/ijp.6950","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the discoloration and surface properties of four CAD/CAM composite resins following storage in various food solutions and exposure to cigarette smoke.</p><p><strong>Materials and methods: </strong>A total of 74 specimens (N = 370) were prepared for five materials: Brilliant Crios (BC), Cerasmart (GC), Lava Ultimate (LU), Shofu Block HC (SH), and Sonic Fill 2 (SO). Discoloration (ΔE) was investigated with a spectrophotometer. Measurements were taken before immersion in storage media (carrot juice, curry, cigarette smoke, red wine, energy drink, and distilled water), after 2 weeks of immersion, and after manual polishing of the specimens following immersion. The average surface roughness (Ra) was measured with a profilometer. Qualitative surface observation was performed with scanning electron microscopy (SEM). Data were analyzed using Kolmogorov-Smirnov test, Mann-Whitney <i>U</i> test, and one-way ANOVA with Tukey post hoc test.</p><p><strong>Results: </strong>The highest influence on ΔE after immersion was observed for storage medium (ηη<sub>P</sub><sup>2</sup> = 0.878, <i>P</i> < .001), followed by the interaction between storage medium and material (η<sub>P</sub><sup>2</sup> = 0.770, <i>P</i> < .001) and material (η<sub>P</sub><sup>2</sup> = 0.306, <i>P</i> < .001). For ΔE after polishing, the highest influence was indicated by the interaction between material and medium (η<sub>P</sub><sup>2</sup> = 0.554, <i>P</i> < .001), followed by medium (η<sub>P</sub><sup>2</sup> = 0.244, <i>P</i> < .001) and material (η<sub>P</sub><sup>2</sup> = 0.196, <i>P</i> < .001). Immersion in carrot juice led to the highest color change (ΔE: 8.0 to 10.4), whereas the lowest values were recorded in distilled water (ΔE: 2.0 to 2.4). Carrot juice and the energy drink caused the highest Ra values (0.120 μm to 0.355 μm). SEM pictures indicated a loss of the organic matrix after manual polishing.</p><p><strong>Conclusion: </strong>The different materials reacted dissimilarly to the various storage media in terms of discoloration. Surface roughness increased after immersion or polishing. Neither discoloration nor surface roughness could be reset to default by manual polishing. Int J Prosthodont 2023;36:194-202. doi: 10.11607/ijp.6950.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 2","pages":"194-202"},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9517306","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
Effect of Internal, Office, and Home Bleaching on Shear Bond Strength of Enamel to Porcelain Laminate Veneers 内漂白、办公室漂白和家庭漂白对珐琅质与瓷贴面剪切粘接强度的影响
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-05-01 DOI: 10.11607/ijp.7773
Mahnaz Arshad, Nastaran Vaziri, Sareh Habibzadeh
{"title":"Effect of Internal, Office, and Home Bleaching on Shear Bond Strength of Enamel to Porcelain Laminate Veneers","authors":"Mahnaz Arshad, Nastaran Vaziri, Sareh Habibzadeh","doi":"10.11607/ijp.7773","DOIUrl":"10.11607/ijp.7773","url":null,"abstract":"<p><strong>Purpose: </strong>To compare the effect of office, home, and internal bleaching on the shear bond strength (SBS) of enamel to porcelain laminate veneers.</p><p><strong>Materials and methods: </strong>A total of 36 extracted maxillary central incisors were randomly assigned to four groups: (1) no bleaching (control); (2) office bleaching with 40% hydrogen peroxide (HP); (3) home bleaching with 15% carbamide peroxide; and (4) intracoronal bleaching with sodium perborate (SP) using the walking bleaching technique. All teeth were separately immersed in artificial saliva for 14 days. The enamel surface was then reduced by 0.5 mm, and IPS e.max Press ceramic discs were bonded using a resin cement. After 24 hours, all specimens were thermocycled (5,000 cycles, 5°C to 55°C). The SBS was measured using a universal testing machine, and the failure mode was determined using a stereomicroscope. One-way ANOVA and Tukey honest significant difference tests were used for data analysis (P < .05).</p><p><strong>Results: </strong>A significant difference was noted among the groups (P < .001). The highest SBS was noted in the control group (15.71 ± 5.39 MPa). The mean SBS in the office bleaching group (12.30 ± 4.64 MPa) was almost the same as the control. The lowest mean SBS belonged to the home bleaching group (5.39 ± 3.99 MPa). The mode of failure was adhesive in all four groups.</p><p><strong>Conclusion: </strong>If bleaching is intended to be followed by porcelain veneers, the office bleaching technique with 40% HP is recommended. Delaying the bonding procedure for 2 weeks does not appear to be effective with home or intracoronal bleaching.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"323-330"},"PeriodicalIF":2.3,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9762736","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Immediate Single-Implant Placement Under Different Loading Conditions: A Retrospective Study with 1 to 5 Years of Follow-Up. 在不同负荷条件下立即放置单种植体:一项1至5年随访的回顾性研究。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-03-01 DOI: 10.11607/ijp.7518
Francesco Amato, Roberto Luongo, Kyrenia Medina, Giorgio Alfredo Spedicato
{"title":"Immediate Single-Implant Placement Under Different Loading Conditions: A Retrospective Study with 1 to 5 Years of Follow-Up.","authors":"Francesco Amato,&nbsp;Roberto Luongo,&nbsp;Kyrenia Medina,&nbsp;Giorgio Alfredo Spedicato","doi":"10.11607/ijp.7518","DOIUrl":"https://doi.org/10.11607/ijp.7518","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate and analyze the effects of different prosthetic protocols under different loading and occlusal conditions on the survival rates of single implants immediately placed into fresh extraction sockets of maxillary or mandibular premolars with single-stage surgery.</p><p><strong>Materials and methods: </strong>Patients needing replacement of a single premolar in the maxilla or mandible were included and randomly divided into three groups based on the different loading protocols: group 1 = healing abutment; group 2 = provisional crown left out of occlusion without functional loading; and group 3 = provisional crown in functional occlusion in maximum intercuspation without contact in excursions. The hypothesis was that single implants inserted into fresh extraction sockets and immediately connected to a temporary crown under functional loading would demonstrate survival rates comparable to single implants placed in the same conditions connected to a healing abutment or to an immediate temporary crown left out of occlusion.</p><p><strong>Results: </strong>A total of 112 patients were treated, and 126 implants were placed (92 in the maxilla and 34 in the mandible). After a mean follow-up of 2.5 years (range 1 to 5 years), there were no failures in groups 1 or 2. Two implants failed in group 3 (one in the maxilla, one in the mandible). The cumulative survival rate was 98.5% across all groups, with 100% in groups 1 and 2 and 95% in group 3. Statistical analysis showed that group 3 displayed a survival rate comparable to groups 1 and 2 (<i>P</i> = .08).</p><p><strong>Conclusion: </strong>Within the limitations of this study, no significant differences were found in terms of implant survival rates between implants inserted into fresh extraction sockets without loading vs with immediate nonfunctional or functional loading. Int J Prosthodont 2023;36:161-171. doi: 10.11607/ijp.7518.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 2","pages":"161-171"},"PeriodicalIF":2.3,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9876110","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Influence of a Novel Lithium Disilicate Coating on Composite-Zirconia Bonding and Bond Characterization. 新型二硅酸锂涂层对复合氧化锆键合及键合表征的影响。
IF 2.3 4区 医学
International Journal of Prosthodontics Pub Date : 2023-03-01 DOI: 10.11607/ijp.6744
Putsadeeporn Thammajaruk, Supanee Buranadham, Taweesak Prasansuttiporn, Massimiliano Guazzato
{"title":"Influence of a Novel Lithium Disilicate Coating on Composite-Zirconia Bonding and Bond Characterization.","authors":"Putsadeeporn Thammajaruk,&nbsp;Supanee Buranadham,&nbsp;Taweesak Prasansuttiporn,&nbsp;Massimiliano Guazzato","doi":"10.11607/ijp.6744","DOIUrl":"https://doi.org/10.11607/ijp.6744","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate microtensile bond strength and characterization with the novel lithium disilicate coating technique compared to conventional air abrasion.</p><p><strong>Materials and methods: </strong>Eight zirconia blocks were fabricated and assigned to two groups (n = 4 each): (1) Lithium disilicate coating followed by hydrofluoric acid etching and Monobond N Primer (LiDi group); and (2) alumina air abrasion (MUL group). For each group, two identically pretreated zirconia blocks were bonded together with Multilink Speed Cement and cut into 30 stick-shaped specimens (1 × 1 × 9 mm3). The 120 specimens were stored in water for 24 hours and assigned to one of three groups (n = 20/group): (1) short-term storage for 24 hours; (2) thermocycling for 5,000 cycles; and (3) thermocycling for 10,000 cycles. A microtensile bond strength test was performed and evaluated. The bond strength results were analyzed using two-way ANOVA followed by one-way ANOVA and Tukey HSD (α = .05). Energy-dispersive x-ray spectroscopy (EDS), Fourier-transform infrared (FTIR), x-ray diffraction (XRD), focused ion beam scanning electron microscopy (FIB-SEM), and scanning electron microscopy (SEM) were used for chemical, crystalline phase, and failure mode analyses.</p><p><strong>Results: </strong>The MUL groups recorded higher bond strength than the LiDi groups. Thermocycling significantly decreased the bond strength in both groups. Chemical analyses suggested that the lithium disilicate layer underwent hydrolysis, which compromised long-term bond strength.</p><p><strong>Conclusion: </strong>The bond between composite cement and alumina-abraded zirconia performed better than that with the lithium disilicate coating technique. Int J Prosthodont 2023;36:172-180. doi: 10.11607/ijp.6744.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 2","pages":"172-180"},"PeriodicalIF":2.3,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"9876113","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信