Zaid Ali, Duncan Wood, Abdulrahman Elmougy, Paul Kelleher, Nicolas Martin
{"title":"使用内部铸造与外包增材制造技术的可移动局部义齿框架生产效率的实验室评估","authors":"Zaid Ali, Duncan Wood, Abdulrahman Elmougy, Paul Kelleher, Nicolas Martin","doi":"10.11607/ijp.7132","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the production efficiency of selective laser sintering (SLS) to traditional casting for the fabrication of metal prosthodontic frameworks in a prospective pilot evaluation in a hospital prosthodontic laboratory setting.</p><p><strong>Materials and methods: </strong>The time taken to complete each of the identified stages in the production of 50 removable partial denture frameworks made using either SLS (n = 25) or casting (n = 25) workflows was measured. The mean time for production was calculated for each workflow, and the difference was tested for statistical significance.</p><p><strong>Results/conclusion: </strong>The results indicate that an SLS workflow may be more time-efficient, and further cost-effectiveness research is indicated.</p>","PeriodicalId":50292,"journal":{"name":"International Journal of Prosthodontics","volume":"36 3","pages":"338-342"},"PeriodicalIF":2.1000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Laboratory Evaluation of Production Efficiency for Removable Partial Denture Frameworks Using In-House Casting vs Outsourced Additive Manufacturing Techniques\",\"authors\":\"Zaid Ali, Duncan Wood, Abdulrahman Elmougy, Paul Kelleher, Nicolas Martin\",\"doi\":\"10.11607/ijp.7132\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare the production efficiency of selective laser sintering (SLS) to traditional casting for the fabrication of metal prosthodontic frameworks in a prospective pilot evaluation in a hospital prosthodontic laboratory setting.</p><p><strong>Materials and methods: </strong>The time taken to complete each of the identified stages in the production of 50 removable partial denture frameworks made using either SLS (n = 25) or casting (n = 25) workflows was measured. The mean time for production was calculated for each workflow, and the difference was tested for statistical significance.</p><p><strong>Results/conclusion: </strong>The results indicate that an SLS workflow may be more time-efficient, and further cost-effectiveness research is indicated.</p>\",\"PeriodicalId\":50292,\"journal\":{\"name\":\"International Journal of Prosthodontics\",\"volume\":\"36 3\",\"pages\":\"338-342\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.7132\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/ijp.7132","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Laboratory Evaluation of Production Efficiency for Removable Partial Denture Frameworks Using In-House Casting vs Outsourced Additive Manufacturing Techniques
Purpose: To compare the production efficiency of selective laser sintering (SLS) to traditional casting for the fabrication of metal prosthodontic frameworks in a prospective pilot evaluation in a hospital prosthodontic laboratory setting.
Materials and methods: The time taken to complete each of the identified stages in the production of 50 removable partial denture frameworks made using either SLS (n = 25) or casting (n = 25) workflows was measured. The mean time for production was calculated for each workflow, and the difference was tested for statistical significance.
Results/conclusion: The results indicate that an SLS workflow may be more time-efficient, and further cost-effectiveness research is indicated.
期刊介绍:
Official Journal of the European Association for Osseointegration (EAO), the International College of Prosthodontists (ICP), the German Society of Prosthodontics and Dental Materials Science (DGPro), and the Italian Academy of Prosthetic Dentistry (AIOP)
Prosthodontics demands a clinical research emphasis on patient- and dentist-mediated concerns in the management of oral rehabilitation needs. It is about making and implementing the best clinical decisions to enhance patients'' quality of life via applied biologic architecture - a role that far exceeds that of traditional prosthetic dentistry, with its emphasis on materials and techniques. The International Journal of Prosthodontics is dedicated to exploring and developing this conceptual shift in the role of today''s prosthodontist, clinician, and educator alike. The editorial board is composed of a distinguished team of leading international scholars.