arXiv - PHYS - Medical Physics最新文献

筛选
英文 中文
A Low-Field Magnetic Resonance Signal Transmission and Reception Processing Platform 低场磁共振信号传输和接收处理平台
arXiv - PHYS - Medical Physics Pub Date : 2024-09-13 DOI: arxiv-2409.08671
Zesong Jiang, Muhang Zhang, Qing Zhang, Yuchong Xie
{"title":"A Low-Field Magnetic Resonance Signal Transmission and Reception Processing Platform","authors":"Zesong Jiang, Muhang Zhang, Qing Zhang, Yuchong Xie","doi":"arxiv-2409.08671","DOIUrl":"https://doi.org/arxiv-2409.08671","url":null,"abstract":"In magnetic resonance imaging (MRI), the spectrometer is a fundamental\u0000component of MRI systems, responsible for the transmission of radiofrequency\u0000(RF) pulses that excite hydrogen nuclei and the subsequent acquisition of MR\u0000signals for processing. However, detailed knowledge about this component\u0000remains largely inaccessible due to the proprietary nature of commercial\u0000systems. To address this gap, we present an FPGA-based platform specifically\u0000designed for MRI signal transmission and reception in low-field MRI\u0000applications. Additionally, with appropriate chip replacements, this platform\u0000can be adapted for use in mid- and high-field MRI systems. This platform\u0000leverages Direct Digital Synthesis (DDS) technology to generate RF pulses,\u0000offering the flexibility to quickly and precisely adjust soft pulse parameters\u0000to meet the specific requirements of the MRI system. Additionally, the platform\u0000processes MRI signals through digital downconversion techniques and utilizes\u0000CIC and FIR filters to obtain baseband signals. Experimental testing of this\u0000platform has yielded promising results. We hope that this work will inspire\u0000further research and development in the field of MRI spectrometer design.\u0000Furthermore, it is worth noting that with the replacement of relevant chips,\u0000this system can also be adapted for use in mid- and high-field MRI systems.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142259867","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
SynthAorta: A 3D Mesh Dataset of Parametrized Physiological Healthy Aortas 合成主动脉:参数化健康主动脉的三维网格数据集
arXiv - PHYS - Medical Physics Pub Date : 2024-09-13 DOI: arxiv-2409.08635
Domagoj Bošnjak, Gian Marco Melito, Katrin Ellermann, Thomas-Peter Fries
{"title":"SynthAorta: A 3D Mesh Dataset of Parametrized Physiological Healthy Aortas","authors":"Domagoj Bošnjak, Gian Marco Melito, Katrin Ellermann, Thomas-Peter Fries","doi":"arxiv-2409.08635","DOIUrl":"https://doi.org/arxiv-2409.08635","url":null,"abstract":"The effects of the aortic geometry on its mechanics and blood flow, and\u0000subsequently on aortic pathologies, remain largely unexplored. The main\u0000obstacle lies in obtaining patient-specific aorta models, an extremely\u0000difficult procedure in terms of ethics and availability, segmentation, mesh\u0000generation, and all of the accompanying processes. Contrastingly, idealized\u0000models are easy to build but do not faithfully represent patient-specific\u0000variability. Additionally, a unified aortic parametrization in clinic and\u0000engineering has not yet been achieved. To bridge this gap, we introduce a new\u0000set of statistical parameters to generate synthetic models of the aorta. The\u0000parameters possess geometric significance and fall within physiological ranges,\u0000effectively bridging the disciplines of clinical medicine and engineering.\u0000Smoothly blended realistic representations are recovered with convolution\u0000surfaces. These enable high-quality visualization and biological appearance,\u0000whereas the structured mesh generation paves the way for numerical simulations.\u0000The only requirement of the approach is one patient-specific aorta model and\u0000the statistical data for parameter values obtained from the literature. The\u0000output of this work is SynthAorta, a dataset of ready-to-use synthetic,\u0000physiological aorta models, each containing a centerline, surface\u0000representation, and a structured hexahedral finite element mesh. The meshes are\u0000structured and fully consistent between different cases, making them imminently\u0000suitable for reduced order modeling and machine learning approaches.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142259839","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
CTLESS: A scatter-window projection and deep learning-based transmission-less attenuation compensation method for myocardial perfusion SPECT CTLESS:基于散射窗投影和深度学习的心肌灌注 SPECT 无传输衰减补偿方法
arXiv - PHYS - Medical Physics Pub Date : 2024-09-12 DOI: arxiv-2409.07761
Zitong Yu, Md Ashequr Rahman, Craig K. Abbey, Richard Laforest, Nancy A. Obuchowski, Barry A. Siegel, Abhinav K. Jha
{"title":"CTLESS: A scatter-window projection and deep learning-based transmission-less attenuation compensation method for myocardial perfusion SPECT","authors":"Zitong Yu, Md Ashequr Rahman, Craig K. Abbey, Richard Laforest, Nancy A. Obuchowski, Barry A. Siegel, Abhinav K. Jha","doi":"arxiv-2409.07761","DOIUrl":"https://doi.org/arxiv-2409.07761","url":null,"abstract":"Attenuation compensation (AC), while being beneficial for\u0000visual-interpretation tasks in myocardial perfusion imaging (MPI) by SPECT,\u0000typically requires the availability of a separate X-ray CT component, leading\u0000to additional radiation dose, higher costs, and potentially inaccurate\u0000diagnosis due to SPECT/CT misalignment. To address these issues, we developed a\u0000method for cardiac SPECT AC using deep learning and emission scatter-window\u0000photons without a separate transmission scan (CTLESS). In this method, an\u0000estimated attenuation map reconstructed from scatter-energy window projections\u0000is segmented into different regions using a multi-channel input multi-decoder\u0000network trained on CT scans. Pre-defined attenuation coefficients are assigned\u0000to these regions, yielding the attenuation map used for AC. We objectively\u0000evaluated this method in a retrospective study with anonymized clinical\u0000SPECT/CT stress MPI images on the clinical task of detecting defects with an\u0000anthropomorphic model observer. CTLESS yielded statistically non-inferior\u0000performance compared to a CT-based AC (CTAC) method and significantly\u0000outperformed a non-AC (NAC) method on this clinical task. Similar results were\u0000observed in stratified analyses with different sexes, defect extents and\u0000severities. The method was observed to generalize across two SPECT scanners,\u0000each with a different camera. In addition, CTLESS yielded similar performance\u0000as CTAC and outperformed NAC method on the metrics of root mean squared error\u0000and structural similarity index measure. Moreover, as we reduced the training\u0000dataset size, CTLESS yielded relatively stable AUC values and generally\u0000outperformed another DL-based AC method that directly estimated the attenuation\u0000coefficient within each voxel. These results demonstrate the capability of the\u0000CTLESS method for transmission-less AC in SPECT and motivate further clinical\u0000evaluation.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142176593","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Phantom-based gradient waveform measurements with compensated variable-prephasing: Description and application to EPI at 7T 采用补偿可变相位的基于幻影的梯度波形测量:描述并应用于 7T EPI
arXiv - PHYS - Medical Physics Pub Date : 2024-09-11 DOI: arxiv-2409.07203
Hannah Scholten, Tobias Wech, Istvan Homolya, Herbert Köstler
{"title":"Phantom-based gradient waveform measurements with compensated variable-prephasing: Description and application to EPI at 7T","authors":"Hannah Scholten, Tobias Wech, Istvan Homolya, Herbert Köstler","doi":"arxiv-2409.07203","DOIUrl":"https://doi.org/arxiv-2409.07203","url":null,"abstract":"Purpose: Introducing \"compensated variable-prephasing\" (CVP), a phantom-based\u0000method for gradient waveform measurements. The technique is based on the\u0000\"variable-prephasing\" (VP) method, but takes into account the effects of all\u0000gradients involved in the measurement. Methods: We conducted measurements of a trapezoidal test gradient, and of an\u0000EPI readout gradient train with three approaches: VP, CVP, and \"fully\u0000compensated variable-prephasing\" (FCVP). We compared them to one another and to\u0000predictions based on the gradient system transfer function. Furthermore, we\u0000used the measured and predicted EPI gradients for trajectory corrections in\u0000phantom images on a 7T scanner. Results: The VP gradient measurements are confounded by lingering\u0000oscillations of the prephasing gradients, which are compensated in the CVP and\u0000FCVP measurements. FCVP is vulnerable to a sign asymmetry in the gradient\u0000chain. However, the trajectories determined by all three methods resulted in\u0000comparably high EPI image quality. Conclusion: We present a new approach allowing for phantom-based gradient\u0000waveform measurements with high precision, which can be useful for trajectory\u0000corrections in non-Cartesian or single-shot imaging techniques. In our\u0000experimental setup, the proposed \"compensated variable-prephasing\" method\u0000provided the most reliable gradient measurements of the different techniques we\u0000compared.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142176562","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Does time to retreatment matter? An NTCP model to predict radionecrosis after repeat SRS for recurrent brain metastases incorporating time-dependent discounted dose 再治疗时间重要吗?预测复发性脑转移瘤重复SRS后放射性坏死的NTCP模型纳入了随时间变化的折算剂量
arXiv - PHYS - Medical Physics Pub Date : 2024-09-11 DOI: arxiv-2409.07647
Manju Sharma, Issam El Naqa, Penny K Sneed
{"title":"Does time to retreatment matter? An NTCP model to predict radionecrosis after repeat SRS for recurrent brain metastases incorporating time-dependent discounted dose","authors":"Manju Sharma, Issam El Naqa, Penny K Sneed","doi":"arxiv-2409.07647","DOIUrl":"https://doi.org/arxiv-2409.07647","url":null,"abstract":"Purpose: To develop and compare normal tissue complication probability (NTCP)\u0000models for recurrent brain metastases (BMs) treated with repeat single-fraction\u0000stereotactic radiosurgery (SRS), considering time-dependent discounted prior\u0000dose. Methods: We developed three NTCP models of BMs treated with\u0000GammaKnife-based SRS. The maximum dose to 0.2cc (D0.2cc) of each\u0000lesion-specific brain and one-year radionecrosis was fitted using a logistic\u0000model with equivalent-dose conversions in 2 Gy (EQD2). The M0 and M1-retreat\u0000modeled radionecrosis risk following SRS to 1029 non-recurrent lesions\u0000(patients=262) and 2nd SRS to 149 recurrent lesions (patients=87). The M1-combo\u0000model accounted for 2nd SRS and time-dependent discounted 1st SRS dose for\u0000recurrent lesions estimated by a modified Gompertzian function. Results: All\u0000three models fitted the data well (Chi-2 = 0.039-0.089 and p = 0.999-1.000).\u0000The fitted EQD250 was ~103 Gy for M0, ~88 Gy for M1-retreat, and ~165 Gy for\u0000M1-combo. The fitted EQD2_50 exhibited a progressively flatter dose-response\u0000curve across the three models, with values of 1.2 Gy for M0, 0.6 Gy for\u0000M1-retreat, and 0.4 Gy for M1-combo. For the brain D0.2cc of 29Gy and 19Gy, the\u0000steepest to shallowest dose-response or largest change in NTCP, i.e., NTCP29Gy\u0000- NTCP19Gy was observed in M1-retreat (0.16), M0 (0.14) and M1-combo (0.06).\u0000Conclusions: The model-fitted parameters predict that recurrent BMs have a\u0000lower threshold dose tolerance and a more gradual dose response for the 2nd SRS\u0000than non-recurrent BMs. This gradual dose-response becomes even more apparent\u0000when considering the time-dependent discounted 1st SRS as a cumulative 2nd SRS.\u0000Tailoring SRS retreatment protocols based on NTCP modeling can potentially\u0000enhance therapeutic efficacy.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142227573","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Unraveling the Effects of Cluster Transfer-Induced Breakups on $^{12}$C Fragmentation in Hadron Therapy 揭示强子治疗中簇转移诱发的分裂对 $^{12}$C 碎片的影响
arXiv - PHYS - Medical Physics Pub Date : 2024-09-11 DOI: arxiv-2409.07090
Arunima Dev T V, Anagha P. K, Midhun C. V, M. M Musthafa, Vafiya Thaslim T. T, Shaima Akbar, Swapna B, Nicemon Thomas, Antony Joseph, S. Ganesan
{"title":"Unraveling the Effects of Cluster Transfer-Induced Breakups on $^{12}$C Fragmentation in Hadron Therapy","authors":"Arunima Dev T V, Anagha P. K, Midhun C. V, M. M Musthafa, Vafiya Thaslim T. T, Shaima Akbar, Swapna B, Nicemon Thomas, Antony Joseph, S. Ganesan","doi":"arxiv-2409.07090","DOIUrl":"https://doi.org/arxiv-2409.07090","url":null,"abstract":"The capability of standard Geant4 PhysicsLists to address the fragmentation\u0000of $^{12}$C$-^{12}$C was assessed through a comparative analysis with\u0000experimental cross sections reported by Divay et al. and Dudouet et al. The\u0000standard PhysicsLists were found to be inadequate in explaining the\u0000fragmentation systematics. To address this limitation, the breakup component of\u0000fragmentation was systematically integrated into the standard PhysicsList,\u0000which successfully replicated the differential and double differential cross\u0000sections for $alpha$ production. This breakup component was modeled using\u0000fresco CDCC-CRC calculations. This novel physics process was then incorporated\u0000into the Geant4 framework, facilitating the calculation of dose distributions\u0000in water and tissue. The application of this method demonstrated a precise\u0000reproduction of the dose deposited at the Bragg peak region, corroborating the\u0000experimental data from Liedner et al., thereby enhancing the accurate\u0000visibility of dose tailing.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142176594","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
1D Thermoembolization Model Using CT Imaging Data for Porcine Liver 利用猪肝脏 CT 成像数据建立一维热栓塞模型
arXiv - PHYS - Medical Physics Pub Date : 2024-09-10 DOI: arxiv-2409.06811
Rohan Amare, Danielle Stolley, Steve Parrish, Megan Jacobsen, Rick Layman, Chimamanda Santos, Beatrice Riviere, Natalie Fowlkes, David Fuentes, Erik Cressman
{"title":"1D Thermoembolization Model Using CT Imaging Data for Porcine Liver","authors":"Rohan Amare, Danielle Stolley, Steve Parrish, Megan Jacobsen, Rick Layman, Chimamanda Santos, Beatrice Riviere, Natalie Fowlkes, David Fuentes, Erik Cressman","doi":"arxiv-2409.06811","DOIUrl":"https://doi.org/arxiv-2409.06811","url":null,"abstract":"Objective: Innovative therapies such as thermoembolization are expected to\u0000play an important role in improvising care for patients with diseases such as\u0000hepatocellular carcinoma. Thermoembolization is a minimally invasive strategy\u0000that combines thermal ablation and embolization in a single procedure. This\u0000approach exploits an exothermic chemical reaction that occurs when an acid\u0000chloride is delivered via an endovascular route. However, comprehension of the\u0000complexities of the biophysics of thermoembolization is challenging.\u0000Mathematical models can aid in understanding such complex processes and\u0000assisting clinicians in making informed decisions. In this study, we used a\u0000Hagen Poiseuille 1D blood flow model to predict the mass transport and possible\u0000embolization locations in a porcine hepatic artery. Method: The 1D flow model was used on in vivo embolization imaging data of\u0000three pigs. The hydrolysis time constant of acid chloride chemical reaction was\u0000optimized for each pig, and LOOCV method was used to test the model's\u0000predictive ability. Conclusion: This basic model provided a balanced accuracy rate of 66.8% for\u0000identifying the possible locations of embolization in the hepatic artery. Use\u0000of the model provides an initial understanding of the vascular transport\u0000phenomena that are predicted to occur as a result of thermoembolization.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142176596","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Initial Experience of Metabolic Imaging with Hyperpolarized [1-13C]pyruvate MRI in Kidney Transplant Patients 肾移植患者使用超极化[1-13C]丙酮酸核磁共振成像进行代谢成像的初步经验
arXiv - PHYS - Medical Physics Pub Date : 2024-09-10 DOI: arxiv-2409.06664
Xiaoxi Liu, Ying-Chieh Lai., Di Cui, Shiang-Cheng Kung, Meyeon Park, Laszik Zoltan, Peder E. Z. Larson, Zhen J. Wang
{"title":"Initial Experience of Metabolic Imaging with Hyperpolarized [1-13C]pyruvate MRI in Kidney Transplant Patients","authors":"Xiaoxi Liu, Ying-Chieh Lai., Di Cui, Shiang-Cheng Kung, Meyeon Park, Laszik Zoltan, Peder E. Z. Larson, Zhen J. Wang","doi":"arxiv-2409.06664","DOIUrl":"https://doi.org/arxiv-2409.06664","url":null,"abstract":"BACKGROUND: Kidney transplant is the treatment of choice for patients with\u0000end-stage renal disease. Early detection of allograft injury is important to\u0000delay or prevent irreversible damage. PURPOSE: To investigate the feasibility\u0000of hyperpolarized (HP) [1-13C]pyruvate MRI for assessing kidney allograft\u0000metabolism. SUBJECTS: 6 participants (mean age, 45.2 +- 12.4 years, 2 females)\u0000scheduled for kidney allograft biopsy and 5 patients (mean age, 59.6 +- 10.4\u0000years, 2 females) with renal cell carcinoma (RCC). ASSESSMENT: Five of the six\u0000kidney allograft participants underwent biopsy after MRI. Estimated glomerular\u0000filtration rate (eGFR) and urine protein-to-creatine ratio (uPCR) were\u0000collected within 4 weeks of MRI. Kidney metabolism was quantified from HP\u0000[1-13C]pyruvate MRI using the lactate-to-pyruvate ratio in allograft kidneys\u0000and non-tumor bearing kidneys from RCC patients. RESULTS: Biopsy was performed\u0000a mean of 9 days (range 5-19 days) after HP [1-13C]pyruvate MRI. Three biopsies\u0000were normal, one showed low-grade fibrosis and one showed moderate\u0000microvascular inflammation. All had stable functioning allografts with eGFR >\u000060 mL/min/1.73 m2 and normal uPCR. One participant who did not undergo biopsy\u0000had reduced eGFR of 49 mL/min/1.73 m2 and elevated uPCR. The mean\u0000lactate-to-pyruvate ratio was 0.373 in participants with normal findings (n =\u00003) and 0.552 in participants with abnormal findings (n = 2). The\u0000lactate-to-pyruvate ratio was highest (0.847) in the participant with reduced\u0000eGFR and elevated uPRC. Native non-tumor bearing kidneys had a mean\u0000lactate-to-pyruvate ratio of 0.309. DATA CONCLUSION: Stable allografts with\u0000normal findings at biopsy showed lactate-to-pyruvate ratios similar to native\u0000non-tumor bearing kidneys, whereas allografts with abnormal findings showed\u0000higher lactate-to-pyruvate ratios.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142176595","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Water Absorption Dynamics in Medical Foam: Empirical Validation of the Lucas-Washburn Model 医用泡沫吸水动力学:卢卡斯-沃什伯恩模型的经验验证
arXiv - PHYS - Medical Physics Pub Date : 2024-09-10 DOI: arxiv-2409.06265
Weihua Mu, Lina Cao
{"title":"Water Absorption Dynamics in Medical Foam: Empirical Validation of the Lucas-Washburn Model","authors":"Weihua Mu, Lina Cao","doi":"arxiv-2409.06265","DOIUrl":"https://doi.org/arxiv-2409.06265","url":null,"abstract":"This study extends the Lucas-Washburn theory through non-equilibrium\u0000thermodynamic analysis to examine fluid absorption in medical foams used for\u0000hemorrhage control. As a universal model for capillary flow in porous media,\u0000the theory demonstrated strong agreement with experimental results, confirming\u0000its semi-quantitative accuracy. Minor deviations, likely due to material\u0000heterogeneity, were observed and explained, enhancing the theory's\u0000applicability to real-world conditions. Our findings underscore the\u0000universality of the Lucas-Washburn framework and provide valuable insights for\u0000optimizing the design of medical foams, ultimately contributing to more\u0000effective bleeding control solutions in clinical applications.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142176597","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Unsupervised stratification of patients with myocardial infarction based on imaging and in-silico biomarkers 基于成像和实验室内生物标记对心肌梗死患者进行无监督分层
arXiv - PHYS - Medical Physics Pub Date : 2024-09-10 DOI: arxiv-2409.06526
Dolors Serra, Pau Romero, Paula Franco, Ignacio Bernat, Miguel Lozano, Ignacio Garcia-Fernandez, David Soto, Antonio Berruezo, Oscar Camara, Rafael Sebastian
{"title":"Unsupervised stratification of patients with myocardial infarction based on imaging and in-silico biomarkers","authors":"Dolors Serra, Pau Romero, Paula Franco, Ignacio Bernat, Miguel Lozano, Ignacio Garcia-Fernandez, David Soto, Antonio Berruezo, Oscar Camara, Rafael Sebastian","doi":"arxiv-2409.06526","DOIUrl":"https://doi.org/arxiv-2409.06526","url":null,"abstract":"This study presents a novel methodology for stratifying post-myocardial\u0000infarction patients at risk of ventricular arrhythmias using patient-specific\u00003D cardiac models derived from late gadolinium enhancement cardiovascular\u0000magnetic resonance (LGE-CMR) images. The method integrates imaging and\u0000computational simulation with a simplified cellular automaton model,\u0000Arrhythmic3D, enabling rapid and accurate VA risk assessment in clinical\u0000timeframes. Applied to 51 patients, the model generated thousands of\u0000personalized simulations to evaluate arrhythmia inducibility and predict VA\u0000risk. Key findings include the identification of slow conduction channels\u0000(SCCs) within scar tissue as critical to reentrant arrhythmias and the\u0000localization of high-risk zones for potential intervention. The Arrhythmic Risk\u0000Score (ARRISK), developed from simulation results, demonstrated strong\u0000concordance with clinical outcomes and outperformed traditional imaging-based\u0000risk stratification. The methodology is fully automated, requiring minimal user\u0000intervention, and offers a promising tool for improving precision medicine in\u0000cardiac care by enhancing patient-specific arrhythmia risk assessment and\u0000guiding treatment strategies.","PeriodicalId":501378,"journal":{"name":"arXiv - PHYS - Medical Physics","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"142176598","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信