Journal of Oral Implantology最新文献

筛选
英文 中文
Investigation of the Clinical Effects of Peri-Implant Gingival Morphology on Tissue Health. 种植体周围牙龈形态对组织健康影响的临床研究。
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-10-01 DOI: 10.1563/aaid-joi-D-23-00084
Merve Tur, Ebru Sarıbaş
{"title":"Investigation of the Clinical Effects of Peri-Implant Gingival Morphology on Tissue Health.","authors":"Merve Tur, Ebru Sarıbaş","doi":"10.1563/aaid-joi-D-23-00084","DOIUrl":"10.1563/aaid-joi-D-23-00084","url":null,"abstract":"<p><p>This study aims to determine the gingival phenotype around dental implants and the clinical evaluation of the existing phenotype in relation to the tissue health around the implant. Included were 202 dental implants applied to 60 individuals who applied to our service and had at least 1 implant in the mouth, whose prosthetic restoration was completed at least 1 year ago. The effects of keratinized mucosa width (KMW) and gingival thickness (GT), which form the gingival phenotype, on clinical periodontal parameters were evaluated with the obtained data. Of the implants included in the study, 115 were found to have adequate KMW and 87 had insufficient KMW. At the same time, the GT around 74 implants was found to be thick, and the GT around 128 implants was found to be thin. The KMW of those with thin GT was lower than those with thick GT. Plaque index (PI), gingival index (GI), bleeding on probing (BoP), probing depth (PD), gingival recession (GR), and suppuration (SuP) were found to be low in those with adequate KMW. GI, BoP, PD, GR, and SuP were low in patients with thick GT, but there was no significant difference between GT and PI. KMW and GT were associated with peri-implant tissue inflammation and GR. To maintain the health of the peri-implant tissues, it is recommended to have a KMW of at least 2 mm and a thick gingiva.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":" ","pages":"548-555"},"PeriodicalIF":1.6,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41138766","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Management of Posterior Mandibular Bone Cavitation for Dental Implant Placement: A Case Series of 5-24 Years of Follow-Up. 种植牙种植中下颌后骨空洞的处理:5-24年随访的一系列病例。
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-10-01 DOI: 10.1563/aaid-joi-D-22-00211
Won-Bae Park, Hyun-Chang Lim
{"title":"Management of Posterior Mandibular Bone Cavitation for Dental Implant Placement: A Case Series of 5-24 Years of Follow-Up.","authors":"Won-Bae Park, Hyun-Chang Lim","doi":"10.1563/aaid-joi-D-22-00211","DOIUrl":"10.1563/aaid-joi-D-22-00211","url":null,"abstract":"<p><p>Focal osteo-cavitation in the posterior mandible is a condition that clinicians do not know well. Inadvertent implant placement in such areas may result in nerve damage due to abrupt drill penetration and implant displacement in the medullary space. In the present case series, focal osteo-cavitation was managed with the following procedures: (1) undersized drilling, (2) gentle trabecular curettage, (3) bone substitute material grafting in the cavity, and (4) long healing period for osseointegration. In all cases, a sudden loss of drilling pressure immediately after passing through the thin cortical layer revealed focal osteo-cavitation. Following undersized drilling and gentle trabecular curettage, the bone substitute material was packed into the cavity with care not to press the inferior alveolar canal. Implant placement was subsequently performed. Despite a lack of primary implant stability in 3 of 4 cases, all implants were successfully osseointegrated after 6-9 months. Over 5-24 years, all implants functioned well.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":" ","pages":"517-523"},"PeriodicalIF":1.6,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41172828","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A Socket Seal Technique With the Use of Autologous Dental Roots for Socket Seal: A Case Series. 使用自体牙根进行窝沟封闭的窝沟封闭技术:病例系列。
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-10-01 DOI: 10.1563/aaid-joi-D-21-00279
Chung-Chieh Chang, I-Ping Lin, Chih-Chun Mei, Pei-Zhen Tang, Hsiang-Hsi Hong
{"title":"A Socket Seal Technique With the Use of Autologous Dental Roots for Socket Seal: A Case Series.","authors":"Chung-Chieh Chang, I-Ping Lin, Chih-Chun Mei, Pei-Zhen Tang, Hsiang-Hsi Hong","doi":"10.1563/aaid-joi-D-21-00279","DOIUrl":"10.1563/aaid-joi-D-21-00279","url":null,"abstract":"<p><p>The literature identified variations in socket seal surgery, each with limitations. This case series aimed to observe the outcome of using autologous dental root (ADR) for socket sealing on socket preservation (SP). A total of 9 patients with 15 extraction sockets were documented. After flapless extraction, the xenograft or alloplastic grafts were placed in the sockets. Autologous dental roots were prepared extraorally and applied to seal the socket entrance. All SP sites healed uneventfully. Cone-beam computed tomography (CBCT) scan was performed after 4-6 months of healing to evaluate ridge dimensions. The preserved alveolar ridge profiles were verified on CBCT scans and during implant surgery. Implants were placed successfully with a reduced need for guided bone regeneration. Histological biopsy specimens were examined in 3 cases. The histological examination demonstrated vital bone formation and osseointegration of graft particles. All patients completed the final restorations and were monitored for 15.56 ± 9.08 months after functional loading. The favorable clinical outcomes support the use of ADR for SP procedures. It was not only accepted to patients but also easy to perform with low complication rates. The ADR technique is thus a feasible method for socket seal surgery.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":" ","pages":"473-484"},"PeriodicalIF":1.6,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10728497","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Facial Contour Preservation of Anterior Immediate Single-Tooth Replacement With the Socket Shield Technique Versus Connective Tissue Graft: A Case Report. 承窝保护技术与结缔组织移植物保护前即刻单牙置换术的面部轮廓:一例报告。
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-10-01 DOI: 10.1563/aaid-joi-D-23-00009
Sunee Limmeechokchai, Joseph Y K Kan, Kitichai Rungcharassaeng, Joey T Chen, Brian Goodacre, Jaime Lozada
{"title":"Facial Contour Preservation of Anterior Immediate Single-Tooth Replacement With the Socket Shield Technique Versus Connective Tissue Graft: A Case Report.","authors":"Sunee Limmeechokchai, Joseph Y K Kan, Kitichai Rungcharassaeng, Joey T Chen, Brian Goodacre, Jaime Lozada","doi":"10.1563/aaid-joi-D-23-00009","DOIUrl":"10.1563/aaid-joi-D-23-00009","url":null,"abstract":"<p><p>The socket shield technique and subepithelial connective tissue graft following immediate implant placement with provisionalization had been advocated for peri-implant facial contour and gingival architecture preservation. This case report used three-dimensional volumetric analysis to longitudinally assess the peri-implant facial contour change before and after these procedures. The results demonstrated comparable and acceptable preservation of peri-implant facial contour between the two procedures after 2 years of function.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":" ","pages":"495-500"},"PeriodicalIF":1.6,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41180390","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Early Implant Bone Loss in the Preprosthetic Phase: A Retrospective Study. 假体前期早期种植体骨丢失:回顾性研究。
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-08-01 DOI: 10.1563/aaid-joi-D-22-00051
Fathima Banu, Anand Kumar
{"title":"Early Implant Bone Loss in the Preprosthetic Phase: A Retrospective Study.","authors":"Fathima Banu,&nbsp;Anand Kumar","doi":"10.1563/aaid-joi-D-22-00051","DOIUrl":"https://doi.org/10.1563/aaid-joi-D-22-00051","url":null,"abstract":"<p><p>Initiation of the inflammatory response begins with the surgical placement of an implant that stimulates bone remodeling. The occurrence of crestal bone loss during submerged healing affects the prognosis of an implant. Hence, this study was conducted to estimate the early implant bone loss during the preprosthetic phase on bone level implants placed equicrestally. This retrospective observational study included evaluation of crestal bone loss around 271 two-piece implants placed in 149 patients from the archived postsurgical (P1) and preprosthetic (P2) digital orthopantomographic records using MicroDicom software. The outcome was categorized based on (1) sex (male or female), (2) time of implant placement (immediate [I] vs conventional [D]), (3) duration of healing period before loading (conventional [T1] vs delayed [T2]), (4) region of implant placement (maxilla [M1] vs mandible [M2]), and (5) site of implant placement (anterior [A] vs posterior [P]). To find the significant difference between the bivariate samples in the independent groups, an unpaired sample t test was used. The average marginal bone loss during the healing phase was 0.56 ± 0.573 mm in the mesial region and 0.44 ± 0.549 mm in the distal region of the implant, with a statistically significant difference (P < .01). There was no statistically significant difference in crestal bone level with the (1) sex of the patient (male or female), (2) type of implant placement (I or D), (3) time of implant loading (T1 or T2), (4) region of implant placement (M1 or M2), or (5) site of implant in the arch (A or P) (P > .05). An average of 0.50 mm crestal bone loss occurred in the peri-implant region during the preprosthetic phase. We found that the delayed placement of an implant and a delay in the healing period would further increase the early implant bone loss. The difference in the healing period did not alter the outcome of the study.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":"49 4","pages":"355-360"},"PeriodicalIF":1.6,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10226637","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Hemorrhagic Complications in Implant Surgery: A Scoping Review on Etiology, Prevention, and Management. 植入手术中的出血性并发症:病因、预防和管理的综述。
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-08-01 DOI: 10.1563/aaid-joi-D-22-00130
Gerardo La Monaca, Nicola Pranno, Antonella Polimeni, Susanna Annibali, Stefano Di Carlo, Giorgio Pompa, Maria Paola Cristalli
{"title":"Hemorrhagic Complications in Implant Surgery: A Scoping Review on Etiology, Prevention, and Management.","authors":"Gerardo La Monaca,&nbsp;Nicola Pranno,&nbsp;Antonella Polimeni,&nbsp;Susanna Annibali,&nbsp;Stefano Di Carlo,&nbsp;Giorgio Pompa,&nbsp;Maria Paola Cristalli","doi":"10.1563/aaid-joi-D-22-00130","DOIUrl":"https://doi.org/10.1563/aaid-joi-D-22-00130","url":null,"abstract":"<p><p>This article seeks to provide the most relevant aspects of the etiology, prevention, and management of bleeding in routine implant surgery. A comprehensive and systematic electronic search was conducted in MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, and the Cochrane Database of Systematic Reviews databases until June 2021. Further references of interest were retrieved from bibliographic lists of the selected articles and the \"Related Articles\" feature of PubMed. Eligibility criteria were papers about bleeding, hemorrhage, or hematoma associated with routine implant surgery on human subjects. Twenty reviews and 41 case reports fulfilled eligibility criteria and were included in the scoping review. Involved implants were mandibular in 37 and maxillary in 4 cases. The major number of bleeding complications was in the mandibular canine region. The most injured vessels were sublingual and submental arteries, due mainly to perforation of the lingual cortical plate. Time to bleeding occurred intraoperatively, at suturing, or postoperatively. The most reported clinical manifestations were swelling and elevation of the mouth floor and the tongue with partial or complete airway obstructions. First aid to manage airway obstruction was intubation and tracheostomy. For active bleeding control, gauze tamponade, manual or digital compression, hemostatic agents, and cauterization were applied. When conservative procedures failed, hemorrhage was controlled by intra- or extraoral surgical approaches to ligate injured vessels or by angiographic embolization. The present scoping review provides knowledge and evidence on the most relevant aspects of the etiology, prevention, and management of implant surgery bleeding complications.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":"49 4","pages":"414-427"},"PeriodicalIF":1.6,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10226639","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Digitally Guided Lateral Sinus Floor Elevation With Simultaneous Implant Placement: 3 Case Reports With Technical Considerations. 数字引导侧窦底提升同时植入:3例报告及技术考虑。
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-08-01 DOI: 10.1563/aaid-joi-D-22-00198R2
Priscila C Meneghetti, Hamoun Sabri, Ebrahim Dastouri, Rafael M Pereira, Wendel Teixeira, Junying Li, Hom-Lay Wang, Gustavo Mendonça, Rafael Siqueira
{"title":"Digitally Guided Lateral Sinus Floor Elevation With Simultaneous Implant Placement: 3 Case Reports With Technical Considerations.","authors":"Priscila C Meneghetti,&nbsp;Hamoun Sabri,&nbsp;Ebrahim Dastouri,&nbsp;Rafael M Pereira,&nbsp;Wendel Teixeira,&nbsp;Junying Li,&nbsp;Hom-Lay Wang,&nbsp;Gustavo Mendonça,&nbsp;Rafael Siqueira","doi":"10.1563/aaid-joi-D-22-00198R2","DOIUrl":"https://doi.org/10.1563/aaid-joi-D-22-00198R2","url":null,"abstract":"<p><p>A sinus floor elevation via lateral window (LSFE) is one of the most widely used bone augmentation procedures for implant therapy in the posterior area of the maxilla. Locating and preparing a correct opening window on the lateral sinus wall is a key step of this procedure. Conventionally, the surgeon designs and locates the window after the flap is reflected based on the information obtained from cone-beam computed tomography (CBCT) images or other diagnostic aids. Nevertheless, in spite of the advancements in CBCT imaging, clinicians may still experience hardships in situating and procuring meticulous access to the maxillary sinus by using CBCT alone. Therefore, in cases requiring an LSFE simultaneous to implant placement, a maxillary sinus surgical guide has been tested and reported to be the amiable method to be utilized as a conjunct to prevent unpredictable consequences according to its application in implying both the direction for the implant and the location of the lateral window. This article presents 3 clinical cases with a fully digital approach to guide the opening of the lateral wall of the maxillary sinus as well as the simultaneous placement of a single implant in an ideal 3D position. Based on the CBCT images and intraoral scan, a surgical guide was fabricated based on 3D software. During surgery, this teeth-supported template can be placed intraorally, guiding sinus window opening preparation. This technique makes the sinus window opening procedure simple and predictable, reduces surgical time and the risk of complications, and allows the placement of the implant in the ideal 3D position.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":"49 4","pages":"365-371"},"PeriodicalIF":1.6,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10233112","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Thermal Effects of 445-nm Diode Laser Irradiation on Titanium and Ceramic Implants. 445nm二极管激光辐照对钛和陶瓷植入物的热效应。
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-08-01 DOI: 10.1563/aaid-joi-D-22-00234
Loredana Calce, Maryam Hafeez, Wei Hou, Georgios E Romanos
{"title":"Thermal Effects of 445-nm Diode Laser Irradiation on Titanium and Ceramic Implants.","authors":"Loredana Calce,&nbsp;Maryam Hafeez,&nbsp;Wei Hou,&nbsp;Georgios E Romanos","doi":"10.1563/aaid-joi-D-22-00234","DOIUrl":"https://doi.org/10.1563/aaid-joi-D-22-00234","url":null,"abstract":"<p><p>This study aimed to evaluate temperature changes in titanium and ceramic implants after using a 445-nm diode laser under different in vitro conditions. Titanium (Ti) and ceramic (Zr) dental implants were placed into a bone analog, and an intrabony defect was created at each implant. A 445-nm diode laser was used to irradiate the defects for 30 seconds, noncontact, at 2 W in continuous wave (c.w.) and pulsed mode. The experiment was done at room temperature (21.0 ± 1°C) and in a water bath (37.0 ± 1°C). Two thermocouple probes were used to record real-time temperature changes (°C) at the coronal part of the implant (Tc) and the apex (Ta). The temperature was recorded at time 0 (To) and after 30 seconds of irradiation (Tf). The average temperature change was calculated, and a descriptive analysis was conducted (P < .05). The Ti implant resulted in the highest ΔT values coronally (29.6°C) and apically (6.7°C) using continuous wave at 21°C. The Zr implant increased to 26.4°C coronally and 5.2°C apically. In the water bath, the coronal portion of the Ti and Zr implants rose to 14.2°C and 14.01°C, respectively, using continuous waves. The ΔT values for Ti were 11.9°C coronally and 1.7°C apically when placed in a water bath using pulsed mode. The lowest ΔT occurred on the Zr implant with ΔTc and ΔTa of 4.8°C and 0.78°C, respectively. Under in vitro conditions, the 445-nm diode laser in pulsed mode seems to be safe for use on ceramic implants and should be used with caution on titanium implants.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":"49 4","pages":"401-406"},"PeriodicalIF":1.6,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10239314","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Neurological Risks During Implant Placement in the Anterior Maxilla and Mandible: A Literature Review. 上颌前牙和下颌骨种植体植入的神经系统风险:文献综述。
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-08-01 DOI: 10.1563/aaid-joi-D-23-00041
Georgios Romanos, Jesse Mulham, Nathan Morrow, Alan H Farber, Mina Mahdian
{"title":"Neurological Risks During Implant Placement in the Anterior Maxilla and Mandible: A Literature Review.","authors":"Georgios Romanos,&nbsp;Jesse Mulham,&nbsp;Nathan Morrow,&nbsp;Alan H Farber,&nbsp;Mina Mahdian","doi":"10.1563/aaid-joi-D-23-00041","DOIUrl":"https://doi.org/10.1563/aaid-joi-D-23-00041","url":null,"abstract":"<p><p>The placement of implants in the anterior maxillary and mandibular region requires esthetic proficiency and surgical finesse. It is important to consider the esthetic outcome while avoiding any type of nerve injury for the patient. In this literature review, anatomical structures of the anterior jaw were reviewed from a gross anatomical and radiographic interpretation. A discussion on the frequency of neurosensory complications for patients as a result of nerve damage in this region was evaluated. The purpose of this literature review was to educate the dental surgeon to consider the anterior jaw's neurological structures when performing procedures like implant surgery. The mandibular incisive canal (MIC) presents as an extension of the inferior alveolar canal that runs between the mental foramina. The MIC is a structure that is easily depicted in cone-beam computed tomography (CBCT) imaging and is present in most subjects in gross anatomical studies. The anterior loop of the mental nerve is another structure that is discussed in this paper. Although its structure is accurately depicted in CBCT images, its anatomical variations in patients can make implant treatment planning difficult. The maxilla contains 2 neurovascular structures that were discussed. First, the nasopalatine canal and its relation and impact on implant placement is evaluated. Case reports are reviewed that outline a prophylactic enucleation and bone grafting of the canal prior to implant placement. Second, the canalis sinuosus, which houses the anterior superior alveolar nerve, is of concern during implant placement in the lateral incisor region. Case reports involving nerve damage with follow-up are discussed.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":"49 4","pages":"428-435"},"PeriodicalIF":1.6,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10291983","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Systematic Reviews and Meta-analyses: Are They a Reliable Resource for Making Sound Clinical Decisions? 系统评价和荟萃分析:它们是做出合理临床决策的可靠资源吗?
IF 1.6 4区 医学
Journal of Oral Implantology Pub Date : 2023-08-01 DOI: 10.1563/aaid-joi-D-4904.Editorial
Edgard El Chaar, James L Rutkowski
{"title":"Systematic Reviews and Meta-analyses: Are They a Reliable Resource for Making Sound Clinical Decisions?","authors":"Edgard El Chaar,&nbsp;James L Rutkowski","doi":"10.1563/aaid-joi-D-4904.Editorial","DOIUrl":"10.1563/aaid-joi-D-4904.Editorial","url":null,"abstract":"","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":"49 4","pages":"343"},"PeriodicalIF":1.6,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"10245014","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信