Sensor Review最新文献

筛选
英文 中文
An integrated low-cost automatic pipetting used in nucleic acid detection PCR instrument and clinical detection 用于核酸检测 PCR 仪器和临床检测的集成式低成本自动移液器
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-05-02 DOI: 10.1108/sr-08-2023-0366
Chengxiong Lin, Wenming Wu
{"title":"An integrated low-cost automatic pipetting used in nucleic acid detection PCR instrument and clinical detection","authors":"Chengxiong Lin, Wenming Wu","doi":"10.1108/sr-08-2023-0366","DOIUrl":"https://doi.org/10.1108/sr-08-2023-0366","url":null,"abstract":"<h3>Purpose</h3>\u0000<p>This paper aims to introduce a custom-designed integrated nucleic acid detection polymerase chain reaction (PCR) instrument for clinical detection applications.</p><!--/ Abstract__block -->\u0000<h3>Design/methodology/approach</h3>\u0000<p>The PCR instrument can make rapid, sensitive, low-cost and quantitative molecular diagnosis compared with the current routine test flow from the pipette, series reagent to RT-PCR by manual manipulation. By integrating the multichannel automatic pipetting module, heat amplification module and real-time fluorescence detection module for the first time, the custom-designed integrated nucleic acid detection PCR instrument can achieve sample collection, subpackage, mixing, extracting, measuring and result presentation.</p><!--/ Abstract__block -->\u0000<h3>Findings</h3>\u0000<p>The multichannel automatic pipetting module was assembled with an accuracy of 0.4% (2 microliters) for accuracy measurement. Besides, the accuracy and sensitivity of nucleic acid using integrated low-cost nucleic acid detection PCR instruments were checked with COV-2019 virus (staining method) and African swine fever virus (probe method) under different concentrations.</p><!--/ Abstract__block -->\u0000<h3>Practical implications</h3>\u0000<p>Because of its high cost, complex system and bulky laboratory settings, including sample subpackage, mixing, extracting, measuring and finally result in presentation, the current nucleic acid detection system is not suitable for field operation and disease diagnosis in remote areas. The group independently designed and assembled an integrated low-cost multichannel nucleic acid detection PCR instrument, including a multichannel automatic pipetting module, a heat amplification module and a real-time fluorescence detection module.</p><!--/ Abstract__block -->\u0000<h3>Originality/value</h3>\u0000<p>The above equipment showed better reliability compared with commercial qPCR. These results can lay the foundation for functional, fast and low-cost PCR equipment for trace measurements.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"22 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140840239","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
MEMS flexible conformal hydrophone based on heterogeneous integration technology 基于异质集成技术的 MEMS 柔性保形水听器
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-04-30 DOI: 10.1108/sr-01-2024-0032
Xiangkai Zhang, Renxin Wang, Wenping Cao, Guochang Liu, Haoyu Tan, Haoxuan Li, Jiaxing Wu, Guojun Zhang, Wendong Zhang
{"title":"MEMS flexible conformal hydrophone based on heterogeneous integration technology","authors":"Xiangkai Zhang, Renxin Wang, Wenping Cao, Guochang Liu, Haoyu Tan, Haoxuan Li, Jiaxing Wu, Guojun Zhang, Wendong Zhang","doi":"10.1108/sr-01-2024-0032","DOIUrl":"https://doi.org/10.1108/sr-01-2024-0032","url":null,"abstract":"<h3>Purpose</h3>\u0000<p>Human-induced marine environmental noise, such as commercial shipping and seismic exploration, is concentrated in the low-frequency range. Meanwhile, low-frequency sound signals can achieve long-distance propagation in water. To meet the requirements of long-distance underwater detection and communication, this paper aims to propose an micro-electro-mechanical system (MEMS) flexible conformal hydrophone for low-frequency underwater acoustic signals. The substrate of the proposed hydrophone is polyimide, with silicon as the piezoresistive unit.</p><!--/ Abstract__block -->\u0000<h3>Design/methodology/approach</h3>\u0000<p>This paper proposes a MEMS heterojunction integration process for preparing flexible conformal hydrophones. In addition, sensors prepared based on this process are non-contact flexible sensors that can detect weak signals or small deformations.</p><!--/ Abstract__block -->\u0000<h3>Findings</h3>\u0000<p>The experimental results indicate that making devices with this process cannot only achieve heterogeneous integration of silicon film, metal wire and polyimide, but also allow for customized positions of the silicon film as needed. The success rate of silicon film transfer printing is over 95%. When a stress of 1 Pa is applied on the <em>x</em>-axis or <em>y</em>-axis, the maximum stress on Si as a pie-zoresistive material is above, and the average stress on the Si film is around.</p><!--/ Abstract__block -->\u0000<h3>Originality/value</h3>\u0000<p>The flexible conformal vector hydrophone prepared by heterogeneous integration technology provides ideas for underwater acoustic communication and signal acquisition of biomimetic flexible robotic fish.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"81 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140812922","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Line spacing effect on the giant magnetoimpedance behavior on microribbon with meander type: a comparison of theory and experiment 线间距对蜿蜒型微晶带巨磁阻行为的影响:理论与实验比较
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-04-23 DOI: 10.1108/sr-08-2023-0325
Zhenbao Wang, Zhen Yang, Mengyu Liu, Ziqin Meng, Xuecheng Sun, Huang Yong, Xun Sun, Xiang Lv
{"title":"Line spacing effect on the giant magnetoimpedance behavior on microribbon with meander type: a comparison of theory and experiment","authors":"Zhenbao Wang, Zhen Yang, Mengyu Liu, Ziqin Meng, Xuecheng Sun, Huang Yong, Xun Sun, Xiang Lv","doi":"10.1108/sr-08-2023-0325","DOIUrl":"https://doi.org/10.1108/sr-08-2023-0325","url":null,"abstract":"<h3>Purpose</h3>\u0000<p>Microribbon with meander type based on giant magnetoimpedance (GMI) effect has become a research hot spot due to their higher sensitivity and spatial resolution. The purpose of this paper is to further optimize the line spacing to improve the performance of meanders for sensor application.</p><!--/ Abstract__block -->\u0000<h3>Design/methodology/approach</h3>\u0000<p>The model of GMI effect of microribbon with meander type is established. The effect of line spacing (Ls) on GMI behavior in meanders is analyzed systematically.</p><!--/ Abstract__block -->\u0000<h3>Findings</h3>\u0000<p>Comparison of theory and experiment indicates that decreasing the line spacing increases the negative mutual inductance and a consequent increase in the GMI effect. The maximum value of the GMI ratio increases from 69% to 91.8% (simulation results) and 16.9% to 51.4% (experimental results) when the line spacing is reduced from 400 to 50 µm. The contribution of line spacing versus line width to the GMI ratio of microribbon with meander type was contrasted. This behavior of the GMI ratio is dominated by the overall negative contribution of the mutual inductance.</p><!--/ Abstract__block -->\u0000<h3>Originality/value</h3>\u0000<p>This paper explores the effect of line spacing on the GMI ratio of meander type by comparing the simulation results with the experimental results. The superior line spacing is found in the identical sensing area. The findings will contribute to the design of high-performance micropatterned ribbon with meander-type GMI sensors and the establishment of a ribbon-based magnetic-sensitive biosensing system.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"24 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140634527","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A molecular imprinting electrochemical sensor for detection of anticancer drug amsacrine 一种用于检测抗癌药物安吖啶的分子印迹电化学传感器
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-04-23 DOI: 10.1108/sr-07-2023-0314
Xiaotong Zhang, Qiu Zhang
{"title":"A molecular imprinting electrochemical sensor for detection of anticancer drug amsacrine","authors":"Xiaotong Zhang, Qiu Zhang","doi":"10.1108/sr-07-2023-0314","DOIUrl":"https://doi.org/10.1108/sr-07-2023-0314","url":null,"abstract":"<h3>Purpose</h3>\u0000<p>The purpose of this study is to develop a molecular imprinting electrochemical sensor for the specific detection of the anticancer drug amsacrine. The sensor used a composite of bacterial cellulose (BC) and silver nanoparticles (AgNPs) as a platform for the immobilization of a molecularly imprinted polymer (MIP) film. The main objective was to enhance the electrochemical properties of the sensor and achieve a high level of selectivity and sensitivity toward amsacrine molecules in complex biological samples.</p><!--/ Abstract__block -->\u0000<h3>Design/methodology/approach</h3>\u0000<p>The composite of BC-AgNPs was synthesized and characterized using FTIR, XRD and SEM techniques. The MIP film was molecularly imprinted to selectively bind amsacrine molecules. Electrochemical characterization, including cyclic voltammetry and electrochemical impedance spectroscopy, was performed to evaluate the modified electrode’s conductivity and electron transfer compared to the bare glassy carbon electrode (GCE). Differential pulse voltammetry was used for quantitative detection of amsacrine in the concentration range of 30–110 µM.</p><!--/ Abstract__block -->\u0000<h3>Findings</h3>\u0000<p>The developed molecular imprinting electrochemical sensor demonstrated significant improvements in conductivity and electron transfer compared to the bare GCE. The sensor exhibited a linear response to amsacrine concentrations between 30 and 110 µM, with a low limit of detection of 1.51 µM. The electrochemical response of the sensor showed remarkable changes before and after amsacrine binding, indicating the successful imprinting of amsacrine in the MIP film. The sensor displayed excellent selectivity for amsacrine in the presence of interfering substances, and it exhibited good stability and reproducibility.</p><!--/ Abstract__block -->\u0000<h3>Originality/value</h3>\u0000<p>This study presents a novel molecular imprinting electrochemical sensor design using a composite of BC and AgNPs as a platform for MIP film immobilization. The incorporation of BC-AgNPs improved the sensor’s electrochemical properties, leading to enhanced sensitivity and selectivity for amsacrine detection. The successful imprinting of amsacrine in the MIP film contributes to the sensor's specificity. The sensor's ability to detect amsacrine in a concentration range relevant to anticancer therapy and its excellent performance in complex sample matrices add significant value to the field of electrochemical sensing for pharmaceutical analysis.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"22 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140629848","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Review of development trends in smart shoe applications 智能鞋应用发展趋势回顾
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-04-17 DOI: 10.1108/sr-04-2023-0093
Rafiu King Raji, Jian Lin Han, Zixing Li, Lihua Gong
{"title":"Review of development trends in smart shoe applications","authors":"Rafiu King Raji, Jian Lin Han, Zixing Li, Lihua Gong","doi":"10.1108/sr-04-2023-0093","DOIUrl":"https://doi.org/10.1108/sr-04-2023-0093","url":null,"abstract":"<h3>Purpose</h3>\u0000<p>At the moment, in terms of both research and commercial products, smart shoe technology and applications seem not to attract the same magnitude of attention compared to smart garments and other smart wearables such as wrist watches and wrist bands. The purpose of this study is to fill this knowledge gap by discussing issues regarding smart shoe sensing technologies, smart shoe sensor placements, factors that affect sensor placements and finally the areas of smart shoe applications.</p><!--/ Abstract__block -->\u0000<h3>Design/methodology/approach</h3>\u0000<p>Through a review of relevant literature, this study first and foremost attempts to explain what constitutes a smart shoe and subsequently discusses the current trends in smart shoe applications. Discussed in this study are relevant sensing technologies, sensor placement and areas of smart shoe applications.</p><!--/ Abstract__block -->\u0000<h3>Findings</h3>\u0000<p>This study outlined 13 important areas of smart shoe applications. It also uncovered that majority of smart shoe functionality are physical activity tracking, health rehabilitation and ambulation assistance for the blind. Also highlighted in this review are some of the bottlenecks of smart shoe development.</p><!--/ Abstract__block -->\u0000<h3>Originality/value</h3>\u0000<p>To the best of the authors’ knowledge, this is the first comprehensive review paper focused on smart shoe applications, and therefore serves as an apt reference for researchers within the field of smart footwear.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"34 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140580849","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Wearable sensors for monitoring vital signals in sports and health: progress and perspective 用于监测运动和健康生命信号的可穿戴传感器:进展与展望
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-04-16 DOI: 10.1108/sr-02-2024-0080
Jinwei Zhao, Shuolei Feng, Xiaodong Cao, Haopei Zheng
{"title":"Wearable sensors for monitoring vital signals in sports and health: progress and perspective","authors":"Jinwei Zhao, Shuolei Feng, Xiaodong Cao, Haopei Zheng","doi":"10.1108/sr-02-2024-0080","DOIUrl":"https://doi.org/10.1108/sr-02-2024-0080","url":null,"abstract":"<h3>Purpose</h3>\u0000<p>This paper aims to concentrate on recent innovations in flexible wearable sensor technology tailored for monitoring vital signals within the contexts of wearable sensors and systems developed specifically for monitoring health and fitness metrics.</p><!--/ Abstract__block -->\u0000<h3>Design/methodology/approach</h3>\u0000<p>In recent decades, wearable sensors for monitoring vital signals in sports and health have advanced greatly. Vital signals include electrocardiogram, electroencephalogram, electromyography, inertial data, body motions, cardiac rate and bodily fluids like blood and sweating, making them a good choice for sensing devices.</p><!--/ Abstract__block -->\u0000<h3>Findings</h3>\u0000<p>This report reviewed reputable journal articles on wearable sensors for vital signal monitoring, focusing on multimode and integrated multi-dimensional capabilities like structure, accuracy and nature of the devices, which may offer a more versatile and comprehensive solution.</p><!--/ Abstract__block -->\u0000<h3>Originality/value</h3>\u0000<p>The paper provides essential information on the present obstacles and challenges in this domain and provide a glimpse into the future directions of wearable sensors for the detection of these crucial signals. Importantly, it is evident that the integration of modern fabricating techniques, stretchable electronic devices, the Internet of Things and the application of artificial intelligence algorithms has significantly improved the capacity to efficiently monitor and leverage these signals for human health monitoring, including disease prediction.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"85 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140580669","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A technique of a “lab-on-a-chip” for developing a novel biosensor in viewpoint of health-care (PHC) applications and biological regulator sensors 从保健(PHC)应用和生物调节器传感器的角度开发新型生物传感器的 "芯片上的实验室 "技术
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-04-15 DOI: 10.1108/sr-03-2024-0211
Majid Monajjemi, Fatemeh Mollaamin
{"title":"A technique of a “lab-on-a-chip” for developing a novel biosensor in viewpoint of health-care (PHC) applications and biological regulator sensors","authors":"Majid Monajjemi, Fatemeh Mollaamin","doi":"10.1108/sr-03-2024-0211","DOIUrl":"https://doi.org/10.1108/sr-03-2024-0211","url":null,"abstract":"<h3>Purpose</h3>\u0000<p>Recently, powerful instruments for biomedical engineering research studies, including disease modeling, drug designing and nano-drug delivering, have been extremely investigated by researchers. Particularly, investigation in various microfluidics techniques and novel biomedical approaches for microfluidic-based substrate have progressed in recent years, and therefore, various cell culture platforms have been manufactured for these types of approaches. These microinstruments, known as tissue chip platforms, mimic in vivo living tissue and exhibit more physiologically similar vitro models of human tissues. Using lab-on-a-chip technologies in vitro cell culturing quickly caused in optimized systems of tissues compared to static culture. These chipsets prepare cell culture media to mimic physiological reactions and behaviors.</p><!--/ Abstract__block -->\u0000<h3>Design/methodology/approach</h3>\u0000<p>The authors used the application of lab chip instruments as a versatile tool for point of health-care (PHC) applications, and the authors applied a current progress in various platforms toward biochip DNA sensors as an alternative to the general bio electrochemical sensors. Basically, optical sensing is related to the intercalation between glass surfaces containing biomolecules with fluorescence and, subsequently, its reflected light that arises from the characteristics of the chemical agents. Recently, various techniques using optical fiber have progressed significantly, and researchers apply highlighted remarks and future perspectives of these kinds of platforms for PHC applications.</p><!--/ Abstract__block -->\u0000<h3>Findings</h3>\u0000<p>The authors assembled several microfluidic chips through cell culture and immune-fluorescent, as well as using microscopy measurement and image analysis for RNA sequencing. By this work, several chip assemblies were fabricated, and the application of the fluidic routing mechanism enables us to provide chip-to-chip communication with a variety of tissue-on-a-chip. By lab-on-a-chip techniques, the authors exhibited that coating the cell membrane via poly-dopamine and collagen was the best cell membrane coating due to the monolayer growth and differentiation of the cell types during the differentiation period. The authors found the artificial membrane, through coating with Collagen-A, has improved the growth of mouse podocytes cells-5 compared with the fibronectin-coated membrane.</p><!--/ Abstract__block -->\u0000<h3>Originality/value</h3>\u0000<p>The authors could distinguish the differences across the patient cohort when they used a collagen-coated microfluidic chip. For instance, von Willebrand factor, a blood glycoprotein that promotes hemostasis, can be identified and measured through these type-coated microfluidic chips.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"100 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140580382","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A review of surface acoustic wave sensors: mechanisms, stability and future prospects 表面声波传感器综述:机制、稳定性和未来前景
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-04-15 DOI: 10.1108/sr-02-2024-0165
Zhaozhao Tang, Wenyan Wu, Po Yang, Jingting Luo, Chen Fu, Jing-Cheng Han, Yang Zhou, Linlin Wang, Yingju Wu, Yuefei Huang
{"title":"A review of surface acoustic wave sensors: mechanisms, stability and future prospects","authors":"Zhaozhao Tang, Wenyan Wu, Po Yang, Jingting Luo, Chen Fu, Jing-Cheng Han, Yang Zhou, Linlin Wang, Yingju Wu, Yuefei Huang","doi":"10.1108/sr-02-2024-0165","DOIUrl":"https://doi.org/10.1108/sr-02-2024-0165","url":null,"abstract":"<h3>Purpose</h3>\u0000<p>Surface acoustic wave (SAW) sensors have attracted great attention worldwide for a variety of applications in measuring physical, chemical and biological parameters. However, stability has been one of the key issues which have limited their effective commercial applications. To fully understand this challenge of operation stability, this paper aims to systematically review mechanisms, stability issues and future challenges of SAW sensors for various applications.</p><!--/ Abstract__block -->\u0000<h3>Design/methodology/approach</h3>\u0000<p>This review paper starts with different types of SAWs, advantages and disadvantages of different types of SAW sensors and then the stability issues of SAW sensors. Subsequently, recent efforts made by researchers for improving working stability of SAW sensors are reviewed. Finally, it discusses the existing challenges and future prospects of SAW sensors in the rapidly growing Internet of Things-enabled application market.</p><!--/ Abstract__block -->\u0000<h3>Findings</h3>\u0000<p>A large number of scientific articles related to SAW technologies were found, and a number of opportunities for future researchers were identified. Over the past 20 years, SAW-related research has gained a growing interest of researchers. SAW sensors have attracted more and more researchers worldwide over the years, but the research topics of SAW sensor stability only own an extremely poor percentage in the total researc topics of SAWs or SAW sensors.</p><!--/ Abstract__block -->\u0000<h3>Originality/value</h3>\u0000<p>Although SAW sensors have been attracting researchers worldwide for decades, researchers mainly focused on the new materials and design strategies for SAW sensors to achieve good sensitivity and selectivity, and little work can be found on the stability issues of SAW sensors, which are so important for SAW sensor industries and one of the key factors to be mature products. Therefore, this paper systematically reviewed the SAW sensors from their fundamental mechanisms to stability issues and indicated their future challenges for various applications.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"45 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140580459","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Trends, progress and future directions of nanomaterial based sensors: a bibliometric overview 基于纳米材料的传感器的趋势、进展和未来方向:文献综述
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-04-12 DOI: 10.1108/sr-09-2023-0466
Nibu Babu Thomas, Lekshmi P. Kumar, Jiya James, Nibu A. George
{"title":"Trends, progress and future directions of nanomaterial based sensors: a bibliometric overview","authors":"Nibu Babu Thomas, Lekshmi P. Kumar, Jiya James, Nibu A. George","doi":"10.1108/sr-09-2023-0466","DOIUrl":"https://doi.org/10.1108/sr-09-2023-0466","url":null,"abstract":"&lt;h3&gt;Purpose&lt;/h3&gt;\u0000&lt;p&gt;Nanosensors have a wide range of applications because of their high sensitivity, selectivity and specificity. In the past decade, extensive and pervasive research related to nanosensors has led to significant progress in diverse fields, such as biomedicine, environmental monitoring and industrial process control. This led to better and more efficient detection and monitoring of physical and chemical properties at better resolution, opening new horizons in the development of novel technologies and applications for improved human health, environment protection, enhanced industrial processes, etc.&lt;/p&gt;&lt;!--/ Abstract__block --&gt;\u0000&lt;h3&gt;Design/methodology/approach&lt;/h3&gt;\u0000&lt;p&gt;In this paper, the authors discuss the application of citation network analysis in the field of nanosensor research and development. Cluster analysis was carried out using papers published in the field of nanomaterial-based sensor research, and an in-depth analysis was carried out to identify significant clusters. The purpose of this study is to provide researchers to identify a pathway to the emerging areas in the field of nanosensor research. The authors have illustrated the knowledge base, knowledge domain and knowledge progression of nanosensor research using the citation analysis based on 3,636 Science Citation Index papers published during the period 2011 to 2021.&lt;/p&gt;&lt;!--/ Abstract__block --&gt;\u0000&lt;h3&gt;Findings&lt;/h3&gt;\u0000&lt;p&gt;Among these papers, the bibliographic study identified 809 significant research publications, 11 clusters, 556 research sector keywords, 1,296 main authors, 139 referenced authors, 63 nations, 206 organizations and 42 journals. The authors have identified single quantum dot (QD)-based nanosensor for biological applications, carbon dot-based nanosensors, self-powered triboelectric nanogenerator-based nanosensor and genetically encoded nanosensor as the significant research hotspots that came to the fore in recent years. The future trend in nanosensor research might focus on the development of efficient and cost-effective designs for the detection of numerous environmental pollutants and biological molecules using mesostructured materials and QDs. It is also possible to optimize the detection methods using theoretical models, and generalized gradient approximation has great scope in sensor development.&lt;/p&gt;&lt;!--/ Abstract__block --&gt;\u0000&lt;h3&gt;Research limitations/implications&lt;/h3&gt;\u0000&lt;p&gt;The future trend in nanosensor research might focus on the development of efficient and cost-effective designs for the detection of numerous environmental pollutants and biological molecules using mesostructured materials and QDs. It is also possible to optimize the detection methods using theoretical models, and generalized gradient approximation has great scope in sensor development.&lt;/p&gt;&lt;!--/ Abstract__block --&gt;\u0000&lt;h3&gt;Originality/value&lt;/h3&gt;\u0000&lt;p&gt;This is a novel bibliometric analysis in the area of “nanomaterial based sensor,” which is carried out in CiteSpace software.&lt;/p&gt;&lt;!--/ Abstract","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"45 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140580458","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
The semi-analytical model of capacitive imaging (CI) sensors based on the renormalization group method 基于重正化群法的电容成像(CI)传感器半分析模型
IF 1.6 4区 工程技术
Sensor Review Pub Date : 2024-04-12 DOI: 10.1108/sr-01-2024-0070
Zhen Li, Jianqing Han, Mingrui Zhao, Yongbo Zhang, Yanzhe Wang, Cong Zhang, Lin Chang
{"title":"The semi-analytical model of capacitive imaging (CI) sensors based on the renormalization group method","authors":"Zhen Li, Jianqing Han, Mingrui Zhao, Yongbo Zhang, Yanzhe Wang, Cong Zhang, Lin Chang","doi":"10.1108/sr-01-2024-0070","DOIUrl":"https://doi.org/10.1108/sr-01-2024-0070","url":null,"abstract":"<h3>Purpose</h3>\u0000<p>This study aims to design and validate a theoretical model for capacitive imaging (CI) sensors that incorporates the interelectrode shielding and surrounding shielding electrodes. Through experimental verification, the effectiveness of the theoretical model in evaluating CI sensors equipped with shielding electrodes has been demonstrated.</p><!--/ Abstract__block -->\u0000<h3>Design/methodology/approach</h3>\u0000<p>The study begins by incorporating the interelectrode shielding and surrounding shielding electrodes of CI sensors into the theoretical model. A method for deriving the semianalytical model is proposed, using the renormalization group method and physical model. Based on random geometric parameters of CI sensors, capacitance values are calculated using both simulation models and theoretical models. Three different types of CI sensors with varying geometric parameters are designed and manufactured for experimental testing.</p><!--/ Abstract__block -->\u0000<h3>Findings</h3>\u0000<p>The study’s results indicate that the errors of the semianalytical model for the CI sensor are predominantly below 5%, with all errors falling below 10%. This suggests that the semianalytical model, derived using the renormalization group method, effectively evaluates CI sensors equipped with shielding electrodes. The experimental results demonstrate the efficacy of the theoretical model in accurately predicting the capacitance values of the CI sensors.</p><!--/ Abstract__block -->\u0000<h3>Originality/value</h3>\u0000<p>The theoretical model of CI sensors is described by incorporating the interelectrode shielding and surrounding shielding electrodes into the model. This comprehensive approach allows for a more accurate evaluation of the detecting capability of CI sensors, as well as optimization of their performance.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"100 1","pages":""},"PeriodicalIF":1.6,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"140580805","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信