{"title":"Thermo-mechanical behavior of CLT beam-to-girder assemblies connected with T-shaped dowelled connections before, during and after fire exposure","authors":"Milad Shabanian, N. Braxtan","doi":"10.1108/jsfe-04-2022-0015","DOIUrl":"https://doi.org/10.1108/jsfe-04-2022-0015","url":null,"abstract":"Purpose3-ply cross-laminated timber (CLT) is used to investigate the thermo-mechanical performance of intermediate-size assemblies comprised of T-shaped welded slotted-in steel doweled connections and CLT beams at ambient temperature (AT), after and during non-standard fire exposure.Design/methodology/approachThe first set of experiments was performed as a benchmark to find the load-carrying capacity of the assembly and investigate the failure modes at AT. The post-fire performance (PFP) test was performed to investigate the residual strength of the assembly after 30-min exposure to a non-standard fire. The fire-performance (FP) test was conducted to investigate the thermo-mechanical behavior of the loaded assembly during non-standard fire exposure. In this case, the assembly was loaded to 67% of AT load-carrying capacity and partially exposed to a non-standard fire for 75 min.FindingsEmbedment failure and plastic deformation of the dowels in the beam were the dominant failure modes at AT. The load-carrying capacity of the assembly was reduced to 45% of the ambient capacity after 30 min of fire exposure. Plastic bending of the dowels was the principal failure mode, with row shear in the mid-layer of the CLT beam and tear-out failure of the header sides also observed. During the FP test, ductile embedment failure of the timber in contact with the dowels was the major failure mode at elevated temperature.Originality/valueThis paper presents for the first time the thermo-mechanical performance of CLT beam-to-girder connections at three different thermal conditions. For this purpose, the outside layers of the CLT beams were aligned horizontally.Highlights Load-carrying capacity and failure modes of CLT beam-to-girder assembly with T-shaped steel doweled connections at ambient temperature presented.Residual strength and failure modes of the assembly after 30-min partially exposure to the non-standard fire provided throughout the post-fire performance test.Fire resistance of the assembly partially exposed to the non-standard fire highlighted.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45122637","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Thermomechanical behavior of Glulam-beam connected to CLT-wall assemblies with steel doweled connections before, during and after fire","authors":"Milad Shabanian, N. Braxtan","doi":"10.1108/jsfe-02-2022-0007","DOIUrl":"https://doi.org/10.1108/jsfe-02-2022-0007","url":null,"abstract":"PurposeThermomechanical behavior of intermediate-size beam-to-wall assemblies including Glulam-beams connected to cross-laminated timber (CLT) walls with T-shape steel doweled connections was investigated at ambient temperature (AT) and after and during non-standard fire exposure.Design/methodology/approachThree AT tests were conducted to evaluate the load-carrying capacity and failure modes of the assembly at room temperature. Two post-fire performance (PFP) tests were performed to study the impact of 30-min (PFP30) and 60-min (PFP60) partial exposure to a non-standard fire on the residual strength of the assemblies. The assemblies were exposed to fire in a custom-designed frame, then cooled and loaded to failure. A fire performance (FP) test was conducted to study the fire resistance (FR) during non-standard fire exposure by simultaneously applying fire and a mechanical load equal to 65% of the AT load carrying capacity.FindingsAt AT, embedment failure of the dowels followed by splitting failure at the Glulam-beam and tensile failure of the epoxy between the layers of CLT-walls were the dominant failure modes. In both PFP tests, the plastic bending of the dowels was the only observed failure mode. The residual strength of the assembly was reduced 14% after 30 min and 37% after 60 min of fire exposure. During the FP test, embedment failure of timber in contact with the dowels was the only major failure mode, with the maximum rate of displacement at 51 min into the fire exposure.Originality/valueThis is the first time that the thermomechanical performance of such an assembly with a full-contact connection is presented.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42465396","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Parametric study on the residual compressive strength of RC columns subjected to different standard fire durations and load ratios","authors":"Sara Mirzabagheri, O. Salem","doi":"10.1108/jsfe-04-2022-0017","DOIUrl":"https://doi.org/10.1108/jsfe-04-2022-0017","url":null,"abstract":"PurposeSince columns are critical structural elements, they shall withstand hazards without any considerable damage. In the case of a fire, although concrete has low thermal conductivity compared to other construction materials, its properties are changed at elevated temperatures. Most critically, the residual compressive strengths of reinforced concrete columns are significantly reduced after fire exposure. Validation of the worthiness of rehabilitating concrete structures after fire exposure is highly dependent on accurately determining the residual strengths of fire-damaged essential structural elements such as columns.Design/methodology/approachIn this study, eight reinforced-concrete columns (200 × 200 × 1,500 mm) that were experimentally examined in a prior related study have been numerically modelled using ABAQUS software to investigate their residual compressive strengths after exposure to different durations of standard fire (i.e. one and two hours) while subjected to different applied load ratios (i.e. 20 and 40% of the compressive resistance of the column). Outcomes of the numerical simulations were verified against the prior study's experimental results.FindingsIn a subsequent phase, the results of a parametric study that has been completed as part of the current study to investigate the effects of the applied load ratios show that the application of axial load up to 80% of the compressive resistance of the column did not considerably influence the residual compressive strength of the shorter columns (i.e. 1,500 and 2,000-mm high). However, increasing the height of the column to 2,500 or 3,000 mm considerably reduced the residual compressive strength when the load ratio applied on the columns exceeded 60 and 40%, respectively. Also, when the different columns were simulated under two-hour standard fire exposure, the dominant failure was buckling rather than concrete crushing which was the typical failure mode in most columns.Originality/valueThe outcomes of the numerical study presented in this paper reflect the residual compressive strength of RC columns subjected to various applied load ratios and standard fire durations. Also, the parametric study conducted as part of this research on the effects of higher load ratios and greater column heights on the residual compressive strength of the fire-damaged columns is practical and efficient. The developed computer models can be beneficial to assist engineers in assessing the validity of rehabilitating concrete structures after being exposed to fire.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48190844","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Badr, Maged A. Youssef, S. El-Fitiany, A. Vedrtnam
{"title":"Structural performance of single-skin glass façade systems exposed to fire","authors":"M. Badr, Maged A. Youssef, S. El-Fitiany, A. Vedrtnam","doi":"10.1108/jsfe-05-2022-0021","DOIUrl":"https://doi.org/10.1108/jsfe-05-2022-0021","url":null,"abstract":"PurposeUnderstanding the structural performance of external glass curtain walls (façades) during fire exposure is critical for the safety of the occupants as their failure can lead to fire spread throughout the entire building. This concern is magnified by the recent increase in fire incidents and wildfires. This paper presents the first simplified technique to model single-skin façades during fire exposure and then utilizes it to examine the structural behaviour of vertical, inclined and oversized façade panels.Design/methodology/approachThe proposed technique is based on conducting simplified heat transfer calculations and then utilizing a widely used structural analysis software program to analyze the façade. Validation for the proposed technique with reference to available experimental and numerical studies by others is presented. A parametric study is then conducted to assess the structural performance of different glass façade systems during exposure to fire.FindingsThe proposed technique was found to provide accurate predictions of the structural performance of glass façades during fire exposure. The structural performance of inclined façade systems during fire exposure was found to be superior to vertical and oversized façade systems.Originality/valueThis research paper is the first to provide a simplified technique that can be utilized to model single-skin facades under fire. The presented technique along with the conducted parametric study will improve the understanding of the fire behaviour of single-skin glass facades, which will lead to safer applications.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46937767","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ilias Thanasoulas, Dan Lauridsen, B. Husted, L. Giuliani
{"title":"The finite element method for evaluating the fire behavior of steel structures","authors":"Ilias Thanasoulas, Dan Lauridsen, B. Husted, L. Giuliani","doi":"10.1108/jsfe-03-2022-0012","DOIUrl":"https://doi.org/10.1108/jsfe-03-2022-0012","url":null,"abstract":"PurposeThe purpose of this study is to contribute toward providing the main aspects of numerical modeling the fire behavior of steel structures with finite elements (FEs). The application of the method is presented for a characteristic case study comprising the series of large-scale fire door tests performed at the Danish Institute of Fire and Security Technology.Design/methodology/approachFollowing a general overview of current practices in structural fire engineering, the FE method is used to simulate the large-scale furnace tests on steel doors with thermal insulation exposed to standard fire.FindingsThe FE model is compared with the fire test results, achieving good agreement in terms of developed temperatures and deformations.Originality/valueThe numerical methodology and recommended practices for modeling the fire behavior of steel structures are presented, which can be used in support of performance-based fire design standards.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-08-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44834383","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Residual mechanical properties of basalt fibre reinforced cement mortars at elevated temperatures","authors":"N. Revanna, Charles K. S. Moy","doi":"10.1108/jsfe-04-2022-0020","DOIUrl":"https://doi.org/10.1108/jsfe-04-2022-0020","url":null,"abstract":"PurposeA study on the mechanical characteristics of cementitious mortar reinforced with basalt fibres at ambient and elevated temperatures was carried out. To investigate their effect, chopped basalt fibres with varying percentages were added to the cement mortar.Design/methodology/approachAll the specimens were heated using a muffle furnace. Flexural strength and Compressive strength tests were performed, while monitoring the moisture loss to evaluate the performance of basalt fibre reinforced cementitious mortars at elevated temperatures.FindingsFrom the study, it is clear that basalt fibres can be used to reinforce mortar as the fibres remain unaffected up to 500 °C. Minimal increases in flexural strengths and compressive strengths were measured with the addition of basalt fibres at both ambient and elevated temperatures. SEM pictures revealed fibre matrix interaction/degradation at different temperatures.Originality/valueThe current study shows the potential of basalt fibre addition in mortar as a reinforcement mechanism at elevated temperatures and provides experimental quantifiable mechanical performances of different fibre percentage addition.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"43239218","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Ark Rukhaiyar, Bhagya Jayant, Kunal Dahiya, R. Meena, R. Raj
{"title":"CFD simulations for evaluating the wind effects on high-rise buildings having varying cross-sectional shape","authors":"Ark Rukhaiyar, Bhagya Jayant, Kunal Dahiya, R. Meena, R. Raj","doi":"10.1108/jsfe-04-2022-0016","DOIUrl":"https://doi.org/10.1108/jsfe-04-2022-0016","url":null,"abstract":"PurposeIn this study the comparison is presented for the variation in cross-sectional shape along the height of the building model. For this purpose Model B and Model C are having the considerable variation and Model A result can be easily predicted on the basis of the result of Model B and C while Model X is considered for the validation purposes only and it is well established that the results are within the allowable limit. This paper aims to discuss these wind generated effects in the tall building model.Design/methodology/approachComputational Fluid Dynamics (CFD) in ANSYS: CFX is used to investigate the wind effects on varying cross-sectional shape along the height of the building model.FindingsFrom pressure contours, it was observed that shape and size of the face is independent of the pressure distribution. It is also observed that pressure distribution for the windward face (A) was less than the magnitude of the leeward face for both models. The leeward face and lateral faces had similar pressure distribution. Also slight changes in pressure distribution were observed at the periphery of the models.Originality/valueThis study has been performed to analyse and compare the wind effect on tall buildings having varying cross sections with variation of different cross sections along the height. Most of the studies done in the field of tall buildings are concentrated to one particular cross-sectional shape while the present study investigates wind effects for combination of two types of cross sections along the height. This analysis is performed for wind incidence angles ranging from 0° to 90° at an interval of 30°. Analysis of wind flow characteristics of two models, Models B and C will be computed using CFD. These two models are the variation of Model A which is a combination of two types of cross section that is square and plus. Square and plus cross-sectional heights for Model B are 48 m and 144 m, respectively. Similarly, square and plus cross-sectional heights for Model C are 144 m and 48 m, respectively. The results are interpreted using pressure contours and streamlines, and comparative graphs of drag and lift forces are presented.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45216910","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Influence of fire-resistant coating on the physical characteristics and residual mechanical properties of E350 steel section exposed to elevated temperature","authors":"G. Jaya Kumar, T. Kiran, N. Anand, K. Al-Jabri","doi":"10.1108/jsfe-02-2022-0008","DOIUrl":"https://doi.org/10.1108/jsfe-02-2022-0008","url":null,"abstract":"PurposeMost of the industrial buildings which are designed to moderate loads are constructed using light gauge cold-formed steel (CFS) sections. Residual mechanical properties of CFS sections exposed to elevated temperature need to be investigated as it is necessary to predict the deterioration of elements to avoid failure of the structure or its elements. Also, it would be helpful to decide whether the structural elements need to be replaced or reused. The use of fire-resistant coatings in steel structures significantly reduces the cost of repairing structural elements and also the probability of collapse. This study investigates the effect of fire-resistant coating on post-fire residual mechanical properties of E350 steel grade.Design/methodology/approachIn this study, an attempt has been made to evaluate the residual mechanical properties of E350 steel. A tensile coupon test was performed for the extracted specimens from the exposed CFS section to determine the mechanical properties. Four different fire-resistant coatings were selected and the sections were coated and heated as per ISO 834 fire temperature curve in the transient state for time durations of 30 minutes (821°C), 60 minutes (925°C), 90 minutes (986°C), and 120 minutes (1,029°C). After the exposure, all the coupon specimens were cooled by either ambient conditions (natural air) or water spraying before conducting the tension test on these specimens.FindingsAt 30 min exposure, the reduction in yield and ultimate strength of heated specimens was about 20 and 25% for air and water-cooled specimens compared with reference specimens. Specimens coated with vermiculite and perlite exhibited higher residual mechanical property up to 60 minutes than other coated specimens for both cooling conditions. Generally, water-cooled specimens had shown higher strength loss than air-cooled specimens. Specimens coated with vermiculite and perlite showed an excellent performance than other specimens coated with zinc and gypsum for all heating durations.Originality/valueAs CFS structures are widely used in construction practices, it is crucial to study the mechanical properties of CFS under post-fire conditions. This investigation provides detailed information about the physical and mechanical characteristics of E350 steel coated with different types of fire protection materials after exposure to elevated temperatures. An attempt has been made to improve the residual properties of CFS using the appropriate coatings. The outcome of the present study may enable the practicing engineers to select the appropriate coating for protecting and enhancing the service life of CFS structures under extreme fire conditions.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47417482","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Thac-Quang Nguyen, X. Nguyen, Tri Nguyen, T. Bui-Tien, J. S. Park
{"title":"Numerical study on buckling capacity of steel H-beams under non-uniform temperature distribution","authors":"Thac-Quang Nguyen, X. Nguyen, Tri Nguyen, T. Bui-Tien, J. S. Park","doi":"10.1108/jsfe-01-2022-0002","DOIUrl":"https://doi.org/10.1108/jsfe-01-2022-0002","url":null,"abstract":"PurposeThe strength and stiffness of steel deteriorate rapidly at elevated temperatures. Thus, the characteristics of steel structures exposed to fire have been concerned in recent years. Most studies on the fire response of steel structures were conducted at uniformly distributed temperatures. This study aims to evaluate the buckling capacity of steel H-beams subjected to different loading conditions under non-uniform heating.Design/methodology/approachA numerical investigation was conducted employing finite element analysis software, ABAQUS. A comparison between the numerical analysis results and the experimental data from previous studies was conducted to verify the beam model. Simply supported beams were loaded with several loading conditions including one end moment, end equal moments, uniformly distributed load and concentrated load at midspan. The effects of initial imperfections were considered. The buckling capacities of steel beams under fire using the existing fire design code and the previous study were also generated and compared.FindingsThe results showed that the length-to-height ratio and loading conditions have a great effect on the buckling resistance of steel beams under fire. The capacity of steel beams under non-uniform temperature distribution using the existing fire design code and the previous study can give unconservative values or too conservative values depending on loading conditions. The maximum differences of unconservative and conservative values are −44.5 and 129.2% for beams subjected to end equal moments and one end moment, respectively.Originality/valueThis study provides the buckling characteristics of steel beams under non-uniform temperature considering the influences of initial imperfections, length-to-height ratios, and loading conditions. This study will be beneficial for structural engineers in properly evaluating structures under non-uniform heating conditions.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":" ","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"46759380","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
T. Coelho, S. Diniz, F. Rodrigues, Ruben Van Coile
{"title":"State-of-the-art review of the reliability evaluation of concrete beams exposed to fire","authors":"T. Coelho, S. Diniz, F. Rodrigues, Ruben Van Coile","doi":"10.1108/jsfe-04-2022-0019","DOIUrl":"https://doi.org/10.1108/jsfe-04-2022-0019","url":null,"abstract":"PurposeThis paper aims to investigate the state of the art for the reliability evaluation of reinforced concrete beams in a fire situation. Special emphasis is placed on addressing which parameters were considered probabilistically or deterministically, the prescribed probabilistic models for the assumed stochastic variables, the treatment of the heat transfer mechanism, the quantification of the structural fire performance and the assumed target reliability levels.Design/methodology/approachResearch papers were identified through a search on the Web of Science, Google Scholar and detailed searches within the journals Journal of Structural Fire Engineering, Fire Technology and Fire Safety Journal, supplemented with references known by the authors.FindingsConsidering the state-of-the-art review, gaps in the literature are identified related to (1) the probabilistic evaluation of shear capacity for standard fires and parametric fires, and bending capacity for parametric fires, (2) the absence of reference fragility curves for immediate design application/code calibration and (3) the specification of target safety levels for reliability-based design.Originality/valueThe lack of research papers gathering studies on the reliability of reinforced concrete beams in fire situation makes it difficult to further develop research in the area. The value of this work lies precisely in the collection of the basic information, making it possible to identify gaps to be addressed in future research and the suggestion of a research framework.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":"1 1","pages":""},"PeriodicalIF":1.0,"publicationDate":"2022-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41327116","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}