2010 IEEE SensorsPub Date : 2010-11-01DOI: 10.1109/ICSENS.2010.5690114
H. Sadeghian, J. Goosen, F. van Keulen, Chung-Kai Yang, A. Bossche, P. French
{"title":"Quantitative analysis and decoupling of mass and stiffness effects in cantilever mass sensors","authors":"H. Sadeghian, J. Goosen, F. van Keulen, Chung-Kai Yang, A. Bossche, P. French","doi":"10.1109/ICSENS.2010.5690114","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690114","url":null,"abstract":"Response of nanomechanical resonant mass sensors to adsorption does not only depend on the mass loading, but also on the adsorbate stiffness, adsorption induced surface stresses and location. It is therefore clear that with just resonance frequency measurement, decoupling the stiffness and the mass effects is difficult. A recent theory proposed using the electrostatic pull-in instability (EPI), in combination with the resonance frequency to decouple the aforementioned opposing effects, is presented hereof. In this paper, by performing experiments of adsorption on cantilevers, we 1) performed preliminary experiments on EPI stiffness measurement and show the stiffness effects of typical mass deposition, 2) show that EPI can be used in combination with the frequency measurements, to quantitatively analyze both the stiffness and the mass of the adsorbed material.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125671307","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-11-01DOI: 10.1109/ICSENS.2010.5689873
D. Binger, M. Ozgur, M. Pedersen, Paul D. Sunal, L. Oh, R. Masse, Thomas Short, J. Brown, M. Huff
{"title":"Advanced sensor development by MNX","authors":"D. Binger, M. Ozgur, M. Pedersen, Paul D. Sunal, L. Oh, R. Masse, Thomas Short, J. Brown, M. Huff","doi":"10.1109/ICSENS.2010.5689873","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5689873","url":null,"abstract":"The MEMS and Nanotechnology Exchange (MNX) was established in 1999 with support from the Defense Advanced Research Projects Agency (DARPA) as an implementation service for the United States R&D community. The overriding goal of the MNX is to provide maximum design and fabrication freedom, which is extremely important for enabling high performance and innovation in the development of MEMS sensors. This paper will provide an overview of the MNX operation and review some of the advanced fabrication technologies made available by the MNX for the implementation of advanced MEMS sensors.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116188787","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-11-01DOI: 10.1109/ICSENS.2010.5690161
M. Norgia, A. Pesatori
{"title":"New low cost analog self-mixing vibrometer","authors":"M. Norgia, A. Pesatori","doi":"10.1109/ICSENS.2010.5690161","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690161","url":null,"abstract":"The proposed sensor is based on a self-mixing interferometer (the laser itself acts as interferometer with the back-reflected light). Its working principle is a sort of unwrap of the interferometric signal: by analog elaborations the jumps of the signal are compensated. The sensor exploits the linearity of a single interferometric fringe, achieving resolution much better than half a wavelength, over a wide dispolacement range. The realized sensor combines a very simple optical setup with a low cost electronic elaboration, allowing excellent performances: 1 mm of range measurement with 35 nm resolution, with 10 kHz bandwidth, for a very low material cost, including the optical and electronics components.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"42 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116429356","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-11-01DOI: 10.1109/ICSENS.2010.5690264
C. Washburn, S. Dirk, T. Lambert, W. Yelton, R. Boye, D. Scrymgeour, D. Wheeler, B. Hance
{"title":"Enhancing hydrofluoric acid sensitivity in silicon polymer composites through TiO2 blending","authors":"C. Washburn, S. Dirk, T. Lambert, W. Yelton, R. Boye, D. Scrymgeour, D. Wheeler, B. Hance","doi":"10.1109/ICSENS.2010.5690264","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690264","url":null,"abstract":"The detection of liquid or vapor hydrofluoric acid (HF), a toxic industrial chemical, is an important area for sensor research. The approach presented here uses a conjugated silicon polymer specifically designed to react with the fluoride anion of HF, resulting in a change of the polymer conductivity. The conductivity response of polymer based coatings prepared with and without titanium dioxide (TiO2) to aqueous HF exposure are compared, as is the response of the silicon polymer composite to HF vapor. Coatings were directly compared to the same concentration of hydrochloric, sulfuric, nitric acid, and deionized water. While many chemiresistor-based sensors depend on the physical swelling of the polymer coating in the presence of an analyte, and are therefore reversible, these sensors were designed with a polymeric coating that reacts with the analyte, thereby effecting a permanent change in properties. A permanent change in impedance of 30% in less than 600 sec. with a selectivity of 20∶1 towards fluorine was observed. The lower limit of detection has not been established yet, but an impedance change of 6% occurs when the sensor is exposed to 1 ppm HF. While an impedance change greater than 100% in vapor phase hydrofluoric acid has been shown, the mechanism to explain the enhanced selectivity toward fluorine when TiO2 is added to the sensor coating formulation is currently unknown.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"34 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116487348","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-11-01DOI: 10.1109/ICSENS.2010.5690152
B. Lemke, R. Baskaran, S. Ganapathysubramanian, O. Paul
{"title":"Stress distribution under electroless nickel bumps extracted using arrays of 7×7 piezo-FETs","authors":"B. Lemke, R. Baskaran, S. Ganapathysubramanian, O. Paul","doi":"10.1109/ICSENS.2010.5690152","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690152","url":null,"abstract":"This paper presents CMOS-based, high density arrays of 7×7 n- and p-type piezoresistive field effect transistor (piezo-FET) based stress sensors with a pitch of 23 µm for extracting the distribution of the in-plane normal stress difference σ<inf>xx</inf> - σ<inf>yy</inf> and the in-plane shear stress σ<inf>xy</inf> under electroless Ni bumps. For the first time, pre-deposition stress caused by openings in the passivation, stress induced by the electroless Ni bump deposition, and stress redistributions during annealing processes between 50 °C and 200 °C are presented. Typical values of σ<inf>xx</inf> - σ<inf>yy</inf> = ±25 MPa are introduced by bump deposition. These values are further increased by up to 60% during annealing steps of up to 200 °C. The in-situ monitoring of the mechanical stress redistribution during an anneal at 115 °C shows a relaxation of the material compound by σ<inf>xx</inf> - σ<inf>yy</inf> = ±2.5 MPa over 180 min. The change of the stress components is found to be linear with temperature during thermal cycling resulting in an almost stress-free state at the deposition temperature.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"5 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116530849","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-11-01DOI: 10.1109/ICSENS.2010.5690098
B. Alfeeli, M. Agah
{"title":"Micro preconcentrator for handheld diagnostics of cancer biomarkers in breath","authors":"B. Alfeeli, M. Agah","doi":"10.1109/ICSENS.2010.5690098","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690098","url":null,"abstract":"This paper introduces, for the first time, Maltese-cross pillar design implemented in a 7 mm × 7 mm × 0.35 mm cavity for high-performance microfabricated preconcentrators (μPCs). This high-aspect ratio design provides more surface area over the previously reported basic geometric shapes. Results showed that Maltese-cross provided 27% increases in performance. Moreover, reducing the pillar spacing from 100µm to 10µm and arranging the pillars in staggered fashion have resulted in 145% and 85% increase in performance, respectively. Therefore, it was concluded that both surface area and flow pattern contribute significantly to the device performance. These μPCs achieved high adsorption capacity making them suitable for handheld breath analyzers to concentrate and identify trace-level (low ppm) volatile compounds (cancer biomarkers) found in human breath.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122293218","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-11-01DOI: 10.1109/ICSENS.2010.5690645
Peter Wu
{"title":"The perspective of biomedical electronics","authors":"Peter Wu","doi":"10.1109/ICSENS.2010.5690645","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690645","url":null,"abstract":"The key factors driving both research and market of biomedical electronics are aging populations, rising healthcare costs, the need for access to medical diagnosis and treatment in emerging and remote regions and in homes, and the fast development of biotechnologies. The applications of biomedical electronics in research, design, and development of biomimetic devices/systems, instruments and appliances that treat intractable neurological disorders, restore health and extend life, and enable biotechnology development is an exciting area of future growth for the electronics industry. It is an area that bridge engineering, biology, and medicine. Great opportunities and challenges of biomedical electronics have attracted tremendous research efforts in both academia and industry.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122357135","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-11-01DOI: 10.1109/ICSENS.2010.5690928
Yantao Shen, Yongxiong Wang, J. Zaklit
{"title":"Development of an optical surface characterization sensor for simultaneously measuring both 3-D surface texture and mechanical properties","authors":"Yantao Shen, Yongxiong Wang, J. Zaklit","doi":"10.1109/ICSENS.2010.5690928","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690928","url":null,"abstract":"Current surface characterization technologies are generally sorted into two categories: non-contact and contact-based technologies. Among these technologies, no one can stand out to simultaneously and rapidly measure both surface patterns/textures and mechanical properties such as softness, friction, and mechanical impedance. Our work addresses this problem, through combination of both contact and non-contact optical surface profiling mechanisms, the developed new optical Total Internal Reflection (TIR) based surface texture sensor can be efficiently used for quantitative characterization of surface texture properties including 3-D texture pattern, roughness, and even mechanical properties like softness, etc. We have used this sensor to measure and analyze texture properties of extensive sample surfaces of soft materials. The results demonstrate the high performance of the sensor.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"7 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122818646","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Novel fast laser-based auto-focusing microscope","authors":"Chien-Sheng Liu, Pin-Hao Hu, Yung-Hsing Wang, Shun-Sheng Ke, Yang-Cheng Lin, Yu-Hsiu Chang, J. Horng","doi":"10.1109/ICSENS.2010.5690153","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690153","url":null,"abstract":"In keeping with consumer preferences for ever more high-performance products, a requirement exists for precise and fast auto-focusing microscope systems for the inspection processes in mass production lines. Accordingly, the present study proposes a precise and fast laser-based auto-focusing microscope system in which an auto-focusing capability is achieved by using a position feedback signal from the centroid of the image of the reflected laser beam captured from a CCD sensor. The experimental results show that the proposed auto-focusing microscope system is under a 1 s cycle time and ±3 µm positioning accuracy with a ± 500 µm linear working range. Overall, it is shown that the proposed auto-focusing microscope system has both a fast response and high positioning accuracy.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122128767","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-11-01DOI: 10.1109/ICSENS.2010.5690713
J. Daniel, T. Ng, J. Coleman, Ronald L. Jackson, Jianzhong Liu, R. Jackson
{"title":"Pressure sensors for printed blast dosimeters","authors":"J. Daniel, T. Ng, J. Coleman, Ronald L. Jackson, Jianzhong Liu, R. Jackson","doi":"10.1109/ICSENS.2010.5690713","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690713","url":null,"abstract":"Disposable printed sensor tapes are being developed to record the magnitude of explosive blasts in the battlefield. The goal is to detect and mitigate the possible occurrence of traumatic brain injury in soldiers. This paper presents results on the pressure sensors to measure the blast pressure and the blast noise. The sensors are based on piezoelectric polymers and their fabrication is compatible with roll-to-roll fabrication methods to enable low cost.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"285 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122199274","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}