2010 IEEE SensorsPub Date : 2010-12-01DOI: 10.1109/ICSENS.2010.5690017
K. Hiroi, Masato Yamanouchi, H. Sunahara
{"title":"A proposal of disaster information system based on the Internet technologies","authors":"K. Hiroi, Masato Yamanouchi, H. Sunahara","doi":"10.1109/ICSENS.2010.5690017","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690017","url":null,"abstract":"This research develops an Autonomous Distributed and Cooperative disaster information system based on the Internet technologies which distribute sensor information such as meteorological information. It is essential that disaster prevention systems collect and classify information or deliver to local residents rapidly. However, there are some problems with information sharing among some agencies because these systems have been constructed independently and lack uniformity and scalability. It is difficult to construct the systems which can share information in common for the initial cost and government's administrative structure. These problems cause delays in information distribution. We develop a common infrastructure which can ensure uniformity, scalability and low-cost construction within a jurisdiction. It enables every agency to use all kinds of disaster information in common and has scalability corresponding to the changing information or media with an aim of rapid distribution.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"97 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131669112","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-12-01DOI: 10.1109/ICSENS.2010.5689934
Yu-Chung Chang, J. Ye, Thommey P. Thomas, J. Baker, T. Norris
{"title":"Fiber-optic two-photon fluorescence correlation spectroscopy for remote cell flow velocity measurements","authors":"Yu-Chung Chang, J. Ye, Thommey P. Thomas, J. Baker, T. Norris","doi":"10.1109/ICSENS.2010.5689934","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5689934","url":null,"abstract":"We report the use of a sensitive double-clad fiber (DCF) probe for remote cell flow velocity measurement by the means of two-photon excited fluorescence correlation spectroscopy (FCS). The ability to measure the flow velocities of labeled cells in whole blood has been demonstrated. A flow velocity of as high as 40 cm/s has been measured. The theoretical lower limit is the self-diffusion of the cell, which is almost zero compared to typical body fluid flow. Owing to the unique feature of two-photon excitation, we can monitor multiple fluorescent markers simultaneously. Therefore, using high brightness nanoparticles to generate the reference signal, we can calibrate the real time flow velocity or even calculate the average size of the cells under measurement. The ability to conduct in vivo flow velocity measurement with single cell resolution using the fiber probe would provide a unique way for disease diagnosis or surveillance after treatment.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"31 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133905113","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-12-01DOI: 10.1109/ICSENS.2010.5690049
R. Kawabata, T. Mizoguchi, A. Tsukamoto, Tomoko Yoshimura, A. Kandori, K. Enpuku
{"title":"Immunoassay detection without washing by using AC magnetic susceptibility","authors":"R. Kawabata, T. Mizoguchi, A. Tsukamoto, Tomoko Yoshimura, A. Kandori, K. Enpuku","doi":"10.1109/ICSENS.2010.5690049","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690049","url":null,"abstract":"Our aim in this study was to demonstrate a stable immunoassay using the decrease of AC magnetic susceptibility without washing to separate bound and unbound magnetic markers. To achieve low noise in the immunoassay system, we examined the arrangement of the MR sensors, the calibration of the distance between the MR sensor and the sample, and the magnetic noise generated from the motor. The immunoassay system was improved based on these factors, and we detected mouse IgG conjugated polymer beads with anti-mouse IgG antibody-coated magnetic markers. The noise that resulted from the vibration of the MR sensor was decreased to about 1/6 by fixing the MR sensor on the excitation coils. The difference in the magnetic signal from each sample was also decreased from 40 % to 6% by calibrating the distance. Magnetic signal with a high signal-to-noise ratio (SN = 10 or more) was obtained by low-speed rotation (8 rpm) of the sample and the narrow band (5.3 Hz) of the lock-in amplifier demodulating the magnetic signal. The decrease of the AC magnetic susceptibility showed a strong correlation with the concentration of mouse IgG. Sensitivity of the immunoassay system could be estimated as about 4 fmol/ml in terms of molecular concentration. Immunoassay detection using AC magnetic susceptibility enabled a highly sensitive immunoassay without the conventional washing process.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126524676","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Dual-confocal auto-focus sensing system in ultrafast laser application","authors":"Yung-Hsing Wang, Pin-Hao Hu, Yang-Cheng Lin, Shun-Sheng Ke, Yu-Hsiu Chang, Chien-Sheng Liu, J. Horng","doi":"10.1109/ICSENS.2010.5690156","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690156","url":null,"abstract":"A dual-confocal auto-focus sensing module for measuring defocusing positions of specimens in laser machining systems or inspecting devices is proposed. This sensing module can improve the detecting accuracy by analyzing and fitting signals from the difference between the dual optical paths, and miniaturize the optical apparatus with the superior integrated optical design. This auto-focusing module is especially integrated with the femtosecond laser machining system used to induce microstructures of silicon materials. The results of the simulations and the experiments demonstrate that the values of the positioning accuracy and the repeatability are both less than ±1.5µm with the measuring ranges of ±200µm.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128048087","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-12-01DOI: 10.1109/ICSENS.2010.5690522
M. Sonoyama, Y. Kato, H. Fujita
{"title":"Application of ultrasonic to a hydrogen sensor","authors":"M. Sonoyama, Y. Kato, H. Fujita","doi":"10.1109/ICSENS.2010.5690522","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690522","url":null,"abstract":"A fast responce hydrogen sensor using ultrasonic was developed and demonstrated. It uses the difference in sound velocity between hydrogen and the air. Thus, it is possible to measure hydrogen concentration by measuring the sound velocity changing when hydrogen is mixed in the air. The hydrogen sensor using ultrasonic in this study can be very fast in response time which was less than 84 msec. We also have shown that it is possible to detect hydrogen concentration as low as 100 ppm with the distance between ultrasonic probes as small as 20 mm. Temperature variation test was also demonstrated between −10 and 50°C and confirmed that it can match with calculation results.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"30 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121124531","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-12-01DOI: 10.1109/ICSENS.2010.5690160
C. Yeh, H. Lin, Yu-Cheng Lin, Y. Chang, T. Chang
{"title":"An optical measurement using the DNA hybridization method for specific species of bacteria detection","authors":"C. Yeh, H. Lin, Yu-Cheng Lin, Y. Chang, T. Chang","doi":"10.1109/ICSENS.2010.5690160","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690160","url":null,"abstract":"This paper reports a developed DNA hybridization detection method using gold-streptavidin conjugates as a reporter, the silver enhancement reaction to magnify the detection signal, and a flatbed scanner to detect the hybridization signal. There was a significant difference in grayscale between the experimental samples and the negative control after 18 min. The detection limit for a DNA sample is 8.25 ng/mL with 5 µM of probe and 10−3 µM of AuNPsstreptavidin. The probe specific tests for different DNA samples were discussed: (1) the probe specific tests for various species of bacteria, and (2) the probe specific tests between the various strains of a single species and various species of a single genus. The developed DNA hybridization method is easy, convenient, and rapid.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"6 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126318035","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-12-01DOI: 10.1109/ICSENS.2010.5690090
Yuta Watanabe, S. Kurihara, T. Sugawara
{"title":"Sensor network topology estimation using time-series data from infrared human presence sensors","authors":"Yuta Watanabe, S. Kurihara, T. Sugawara","doi":"10.1109/ICSENS.2010.5690090","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690090","url":null,"abstract":"We describe a method for accurately estimating the topology of sensor networks from time-series data collected from infrared proximity sensors. Our method is a hybrid combining two different methodologies: ant colony optimization (ACO), which is an evolutionary computation algorithm; and an adjacency score, which is a novel statistical measure based on heuristic knowledge. We show that, using actual data gathered from a real-world environment, our method can estimate a sensor network topology whose accuracy is approximately 95% in our environment. This is an acceptable result for real-world sensor-network applications.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"17 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130557289","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-12-01DOI: 10.1109/ICSENS.2010.5690382
I. Matsuya, Maya Sato, Hideaki Kondo, M. Iba, K. Kanekawa, T. Tanii, A. Nishitani, I. Ohdomari, R. Katamura
{"title":"A relative-story displacement sensor resolving the angular error problem","authors":"I. Matsuya, Maya Sato, Hideaki Kondo, M. Iba, K. Kanekawa, T. Tanii, A. Nishitani, I. Ohdomari, R. Katamura","doi":"10.1109/ICSENS.2010.5690382","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690382","url":null,"abstract":"A relative-story displacement sensor for measuring the ceiling-floor displacement and the floor inclination angle was developed. Three pairs of position-sensitive detector (PSD) units and light emitting diode (LED) arrays were utilized for the measurement. The measurement accuracy of the sensor was evaluated using a shaking table and a θ-stage. The outputs from the developed sensor agreed well with the reference, and the accuracy was evaluated to be approximately 0.15 mm in the displacement and 0.1 mrad in the local inclination angle. These results inidicate that the developed sensor resolves the angular error problem on the relative-story displacement measurement and is applicable for assessing the sefety of actual buildings.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124549694","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-12-01DOI: 10.1109/ICSENS.2010.5690086
Pushparaj Pathak, Hong Zhao, Zhongcheng Gong, F. Nie, Tianhua Zhang, Stephen T C Wong, L. Que
{"title":"Real-time tagless monitoring of cell viability using patch-clamp microdevices","authors":"Pushparaj Pathak, Hong Zhao, Zhongcheng Gong, F. Nie, Tianhua Zhang, Stephen T C Wong, L. Que","doi":"10.1109/ICSENS.2010.5690086","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690086","url":null,"abstract":"Real-time tagless monitoring of cell viability using patch-clamp microdevices is reported and validated by using fluorescence imaging techniques for the first time. Specifically, human breast cancer cells MDA-MB-231 have been used for these studies. Systematic experiments on these cells found that the impedance change of captured cells by the micro-electrodes is a valid indicator of cell's living or death, which might provide an efficient way to monitor the drug effects on cells, thereby benefiting high throughput drug screen and discovery process.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"85 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114904340","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
2010 IEEE SensorsPub Date : 2010-12-01DOI: 10.1109/ICSENS.2010.5691004
B. Kwon, W. King, M. Schulmerich, R. Bhargava
{"title":"Mid-infrared thermomechanical sensitivity of microcantilevers for application to infrared spectroscopy","authors":"B. Kwon, W. King, M. Schulmerich, R. Bhargava","doi":"10.1109/ICSENS.2010.5691004","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5691004","url":null,"abstract":"We report the use of bimaterial microcantilever sensors for sensing narrow-band infrared (IR) radiation generated by a monochromator and its application to IR spectroscopy of polymer films. We selected microcantilever sensors of either silicon or silicon nitride and having a thin metal film coating. To assess the IR measurement capability of these cantilevers, the IR sensitivity to noise ratio (SNR), was measured in the mid-IR fingerprint spectral region (5 – 10 µm or 1000 – 2000 cm−1). The measured SNR was in the range of 8 – 90. We further demonstrated the utility of these sensors by using them to collect an IR absorbance spectrum of 1 µm thick polycarbonate film. The characteristic IR peaks for this film could be seen, and compare well with conventional Fourier Transform IR (FT-IR) data. The spectral resolution of the cantilever sensors determined to be in the range 32 – 64 cm−1.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"66 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125991629","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}