2010 IEEE Sensors最新文献

筛选
英文 中文
High precision polymer deposition onto microcantilever sensors using electrohydrodynamic printing 高精度聚合物沉积到微悬臂式传感器上,采用电流体动力印刷
2010 IEEE Sensors Pub Date : 2010-12-01 DOI: 10.1109/ICSENS.2010.5690653
J. Pikul, Philip Graf, Sandipan Mishra, K. Barton, Yongkwan Kim, J. Rogers, A. Alleyne, P. Ferreira, W. King
{"title":"High precision polymer deposition onto microcantilever sensors using electrohydrodynamic printing","authors":"J. Pikul, Philip Graf, Sandipan Mishra, K. Barton, Yongkwan Kim, J. Rogers, A. Alleyne, P. Ferreira, W. King","doi":"10.1109/ICSENS.2010.5690653","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690653","url":null,"abstract":"The ability to deposit functional organic layers with micrometer-scale resolution and precision is critical to the sensitivity and performance of chemical or biological sensors based on microcantilevers. This paper reports the use of electrohydrodynamic jetting to deposit micrometer sized droplets of pure polymer. The polymer droplets were deposited onto microcantilever sensors, with control over droplet size, location, and spacing. Cantilever-based gravimetry analyzed the polymer droplets by examining the shift in microcantilever resonance frequency resulting from droplet deposition. The resonance shift of 150 – 4130 Hz corresponded to a polymer mass of 4.5 – 135 pg. The electrohydrodynamic method is a precise way to deposit multiple materials onto micromechanical sensors with greater resolution than current methods.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"50 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130987412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
On-chip detection of beads with a new electrical impedance sensor 用一种新的电阻抗传感器对微珠进行片上检测
2010 IEEE Sensors Pub Date : 2010-11-02 DOI: 10.1109/ICSENS.2010.5690430
L. Segerink, A. Sprenkels, J. Bomer, A. van den Berg
{"title":"On-chip detection of beads with a new electrical impedance sensor","authors":"L. Segerink, A. Sprenkels, J. Bomer, A. van den Berg","doi":"10.1109/ICSENS.2010.5690430","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690430","url":null,"abstract":"Electrical impedance measurements in microfluidic chips are used for single cell analysis. Parallel electrodes are more suited than planar ones since the electrical field distribution is more homogenous. Previous studies showed methods to make parallel electrodes by incorporating an additional layer between two glass wafers, making electrical connections to both sides needed. Also alignment of electrodes is necessary, making the fabrication of parallel electrodes more elaborate. Therefore a new, simpler fabrication method is developed for the fabrication of parallel electrode chips by incorporating a floating electrode in the microchannel just by adding one step in the fabrication process. In this way, only one side of the chip contains electrical connections. Finally, electrical impedance measurements with 3 and 6 µm polystyrene beads were done. All beads were detected and we have shown that it is possible to distinguish the two beads sizes from each other with a confidence level of 95%, based on the relative change in the electrical impedance.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"9 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129788618","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Enhanced Wireless Sensor Network setup strategy supported by intelligent software agents 智能软件代理支持的增强无线传感器网络设置策略
2010 IEEE Sensors Pub Date : 2010-11-01 DOI: 10.1109/ICSENS.2010.5690968
Edison Pignaton de Freitas, T. Heimfarth, Ivayr Farah Netto, Alex Guimaraes Cardoso de Sa, C. Pereira, Armando Morado Ferreira, Flávio Rech Wagner, Tony Larsson
{"title":"Enhanced Wireless Sensor Network setup strategy supported by intelligent software agents","authors":"Edison Pignaton de Freitas, T. Heimfarth, Ivayr Farah Netto, Alex Guimaraes Cardoso de Sa, C. Pereira, Armando Morado Ferreira, Flávio Rech Wagner, Tony Larsson","doi":"10.1109/ICSENS.2010.5690968","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690968","url":null,"abstract":"A well know problem in the Wireless Sensor Network (WSN) research area is the usage of appropriate strategies to setup the sensor nodes such that they may accomplish sensing missions. This problem refers to the selection of appropriate nodes to perform the different tasks required to the missions' accomplishment and may be thus characterized as an instance of the task and resource allocation problem. Traditional approaches consider pre-planned strategies, which are not flexible to deal with changes in the network and environment operating conditions. This paper presents an enhanced agent-oriented strategy, which consists of a usage of mobile intelligent agents to disseminate missions and nodes' information over the network, as well as stationary software agents installed in the sensor nodes to provide advanced reasoning apparatus for decision making purposes. The proposed enhancement complements the original agent-based approach with robustness features required to overcome extreme adverse conditions in which an ordinary WSN presents poor results. Results from simulations provide evidences of the efficiency of the complete enhanced approach.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"58 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115139243","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
“Sweat-on-a-chip”: Analysing sweat in real time with disposable micro-devices “芯片汗液”:用一次性微型设备实时分析汗液
2010 IEEE Sensors Pub Date : 2010-11-01 DOI: 10.1109/ICSENS.2010.5690681
F. Benito‐Lopez, S. Coyle, Robert Byrne, V. Curto, D. Diamond
{"title":"“Sweat-on-a-chip”: Analysing sweat in real time with disposable micro-devices","authors":"F. Benito‐Lopez, S. Coyle, Robert Byrne, V. Curto, D. Diamond","doi":"10.1109/ICSENS.2010.5690681","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690681","url":null,"abstract":"Here we present the fabrication and the performance of a novel, wearable, robust, flexible and disposable micro-fluidic device which incorporates miniature optical components as a detection system, for wireless monitoring in real time mode of sweat pH during an exercise session. This micro-fluidic platform is completely non-invasive, with the great advantage of providing a continuous flow of fresh sweat for continuous real time analysis, ensuring immediate feedback regarding sweat composition to an athlete and/or coach. To the best of our knowledge, this is the first wearable and wireless micro-fluidic device suitable for real time analysis and reporting of the wearer's physiological state.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"53 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123127575","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 9
Carbon nanotube and graphene based gas micro-sensors fabricated by dielectrophoresis on silicon 基于碳纳米管和石墨烯的硅基气体微传感器
2010 IEEE Sensors Pub Date : 2010-11-01 DOI: 10.1109/ICSENS.2010.5690876
Samuel MacNaughton, S. Sonkusale, Sumedh P. Surwade, S. Ammu, Sanjeev Manohar
{"title":"Carbon nanotube and graphene based gas micro-sensors fabricated by dielectrophoresis on silicon","authors":"Samuel MacNaughton, S. Sonkusale, Sumedh P. Surwade, S. Ammu, Sanjeev Manohar","doi":"10.1109/ICSENS.2010.5690876","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690876","url":null,"abstract":"A gas sensor based upon an array of reduced graphene oxide (RGO) and single wall carbon nanotube (SWNT) micro-assemblies is presented. Due to the nature of their structure and exceptional surface-to-volume ratio, graphene sheets and carbon nanotubes demonstrate unparalleled chemisorption properties, providing greater sensitivities than a bulk material. Micro-assemblies of RGO platelets and SWNT's were created on lithographically-patterned electrode arrays utilizing dielectrophoresis. The resistivity of the assemblies can be tuned by adjusting the amplitude and frequency of the applied field. The completed array was tested in an enclosed chamber into which various gases were introduced (including common volatile organic compounds and simulants of nerve agents). Changes in the resistance of each micro-assembly due to chemisorption were monitored. Both types of assemblies (RGO and SWNT) demonstrated unique and repeatable responses to various organic compounds and other vapors. Consistent assembly and gas response results were achieved for sensor elements across many substrates.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"38 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124385275","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Graphene field-effect transistors for label-free biological sensors 用于无标签生物传感器的石墨烯场效应晶体管
2010 IEEE Sensors Pub Date : 2010-11-01 DOI: 10.1109/ICSENS.2010.5690880
Y. Ohno, K. Maehashi, K. Matsumoto
{"title":"Graphene field-effect transistors for label-free biological sensors","authors":"Y. Ohno, K. Maehashi, K. Matsumoto","doi":"10.1109/ICSENS.2010.5690880","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690880","url":null,"abstract":"Label-free immunosensors based on aptamer-modified graphene field-effect transistors (G-FETs) were realized. Immunoglobulin E (IgE) aptamers were functionalized on the graphene surface. From atomic force microscopy, functionalized IgE aptamer with approximately 3 nm height was observed. And the drain current of the G-FETs increased after IgE aptamers functionalized on the graphene channel owing to the negatively charged aptamer in the solution, indicating the success of the IgE-aptamer functionalization onto the graphene channel. The aptamer-modified G-FETs electrically detected only IgE molecules, indicating the selectively sensing. From IgE concentration dependence of the drain current variation, the dissociation constant between IgE aptamer and IgE reaction was estimated to be 4.7×10−8 M, indicating their good affinity. These results indicate that the G-FETs have high potential for the label-free biological sensors.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124271582","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
CMOS open-gate ion sensitive field effect transistors for femto-molar dopamine detection 用于飞摩尔多巴胺检测的CMOS开栅离子敏感场效应晶体管
2010 IEEE Sensors Pub Date : 2010-11-01 DOI: 10.1109/ICSENS.2010.5690196
Dong-Che Li, M. S. Lu
{"title":"CMOS open-gate ion sensitive field effect transistors for femto-molar dopamine detection","authors":"Dong-Che Li, M. S. Lu","doi":"10.1109/ICSENS.2010.5690196","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690196","url":null,"abstract":"Open-gate ion-sensitive field-effect transistors (ISFET) are presented in this work to provide real-time ultrasensitive dopamine (DA) detection in the femto-molar (fM) range. The polysilicon gates of p-type FETs fabricated in a 0.35-µm CMOS (complementary metal-oxide-semiconductor) process were removed by a convenient post-CMOS process to expose the gate oxide for surface functionalization and biomolecule immobilization. Measured current value increased due to the produced negative charges from binding of the 4-carboxyphenylboronic acid (CPBA) and dopamine molecules. The thin gate oxide as the sensing interface significantly enhances the detection limit, which is comparable to or better than most nanowire-based ISFETs. A self-oscillating readout circuit was used to convert the ISFET current to a digital output for measurement of multiple sensors, showing the strength of the CMOS-based approach for sensor integration.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"115 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"117098069","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 3
Phage Langmuir-Blodgett films for biosensing applications 用于生物传感的噬菌体Langmuir-Blodgett薄膜
2010 IEEE Sensors Pub Date : 2010-11-01 DOI: 10.1109/ICSENS.2010.5690208
E. Olsen, R. Guntupalli, Iryna Sorkulova, Robert Long, W. Neely, V. Vodyanoy
{"title":"Phage Langmuir-Blodgett films for biosensing applications","authors":"E. Olsen, R. Guntupalli, Iryna Sorkulova, Robert Long, W. Neely, V. Vodyanoy","doi":"10.1109/ICSENS.2010.5690208","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690208","url":null,"abstract":"The microstructure and functionality of methicillin-resistant Staphylococcus aureus (MRSA) biosensors prepared from novel Langmuir-Blodgett monolayers of lytic bacteriophage were characterized using scanning imaging ellipsometry (SIE) and scanning electron microscopy (SEM). SEM revealed uniform distribution of phage monolayers immobilized to biosensor substrates. SIE indicated monolayers were 49.8 ± 18.3 nm thick on average. SIE charged couple imaging analysis of biosensors yielded an average intensity of 159±7 and 194±13 for 108 and 109 CFU/ml MRSA concentrations, respectively.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"120983688","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Photo-induced switchable TiO2 thin films for decomposition of air pollutants and microorganisms, self-cleaning surfaces and biological application 光致可切换TiO2薄膜用于分解空气污染物和微生物,自清洁表面和生物应用
2010 IEEE Sensors Pub Date : 2010-11-01 DOI: 10.1109/ICSENS.2010.5690054
O. Berger, W. Fischer
{"title":"Photo-induced switchable TiO2 thin films for decomposition of air pollutants and microorganisms, self-cleaning surfaces and biological application","authors":"O. Berger, W. Fischer","doi":"10.1109/ICSENS.2010.5690054","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690054","url":null,"abstract":"In this work thin films of TiO 2 have been customized for use as gas sensors, for photocatalytic decomposition of toxic gases, organic compounds in the air and microorganisms, as self-cleaning surfaces, as biomaterials for orthopaedic and oral implants. TiO 2 thin films prepared by electron-beam deposition with well defined controlled structure, phase composition, morphology and local surface chemistry of the thin film have been used for study of the correlation between physico-chemical surface characteristics and their multifunctional properties which depend on preparation method and service conditions. These knowledge allows to create tailored surfaces for different application.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121028138","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
A mm-sized implantable power receiver with adaptive matching 一个毫米大小的可植入电源接收器,具有自适应匹配功能
2010 IEEE Sensors Pub Date : 2010-11-01 DOI: 10.1109/ICSENS.2010.5690840
Stephen D. O'Driscol
{"title":"A mm-sized implantable power receiver with adaptive matching","authors":"Stephen D. O'Driscol","doi":"10.1109/ICSENS.2010.5690840","DOIUrl":"https://doi.org/10.1109/ICSENS.2010.5690840","url":null,"abstract":"A wireless power transfer system for implanted medical devices which uses antenna area 100 times smaller than previous designs is presented. The optimum frequency for wireless power transmission through several cm of tissue to mm-sized antennae is demonstrated to be in the low GHz. Simultaneous conjugate matching is introduced which achieves 15dB higher link gain than resonant tuning for this link and adaptive matching circuits desensitize the link to placement inaccuracy and tissue variation. For a 1mm placement inaccuracy the link gain with static matching would fall by 3.7dB but with adaptive matching the gain reduces by only 0.2dB. A high efficiency current-steering rectifier and regulator are developed which together with a 4mm2 antenna deliver 140µW at 1.2V DC from a 4cm2 transmit antenna and a 250mW, 915MHz source through 15mm of tissue. The rectifier efficiency is 65% for a 750mV amplitude received input. The power receiver IC incorporating the adaptive receive match, rectifier and regulator occupies 0.37mm2 in 0.13µm CMOS.","PeriodicalId":439246,"journal":{"name":"2010 IEEE Sensors","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121048979","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书