{"title":"Rapid detection of EBOLA VP40 in microchip immunofiltration assay","authors":"P. Miethe, D. Gary, N. Hlawatsch, A. Gad","doi":"10.1117/12.2184649","DOIUrl":"https://doi.org/10.1117/12.2184649","url":null,"abstract":"In the spring of 2014, the Ebola virus (EBOV) strain Zaire caused a dramatic outbreak in several regions of West Africa. The RT-PCR and antigen capture diagnostic proved to be effective for detecting EBOV in blood and serum. In this paper, we present data of a rapid antigen capture test for the detection of VP40. The test was performed in a microfluidic chip for immunofiltration analysis. The chip integrates all necessary assay components. The analytical sensitivity of the rapid test was 8 ng/ml for recombinant VP40. In serum and whole blood samples spiked with virus culture material, the detection limit was 2.2 x 102 PFU/ml. The performance data of the rapid test (15 min) are comparable to that of the VP40 laboratory ELISA.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"275 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125728951","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. Grishkanich, V. Bespalov, S. K. Vasiev, A. Gusarov, S. Kascheev, V. Elizarov, A. Zhevlakov
{"title":"Monitoring radioactive contamination by hyperspectral lidar","authors":"A. Grishkanich, V. Bespalov, S. K. Vasiev, A. Gusarov, S. Kascheev, V. Elizarov, A. Zhevlakov","doi":"10.1117/12.2177835","DOIUrl":"https://doi.org/10.1117/12.2177835","url":null,"abstract":"There are already significant amounts of hazardous radioactive substances in the world. It, potentially, leads to a major damage and contamination of large areas. Laser sensing can serve as a highly effective method of searching and monitoring of radioactive contamination. We developed a laser system to detect accidental leakage of radioactive materials. Methods of fluorescence spectroscopy and Raman spectroscopy allow to detect a concentration of uranyl U235O2 and U238O2 at 500 ppb, and Sr90 and Cs137 at the level of 1 ppm at 100 m distance from the object.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"6 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127031107","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"New possibilities to analyse non-standard explosives and post blast residues in forensic practice","authors":"M. Kotrlý, I. Turková","doi":"10.1117/12.2183849","DOIUrl":"https://doi.org/10.1117/12.2183849","url":null,"abstract":"Nonstandard and home-made explosives always pose a considerable threat for security forces in terms of their practically unlimited variability, both in composition and in construction of explosive devises. Electron microscopy – SEM with EDS/WDS is one of the key techniques for an analysis of non-standard explosives and post-blast residues. If the amount of materials allows it, a number of other analytical techniques are utilized, such as XRD that is capable of a direct phase identification of a crystalline substance, namely in mixtures. TLC has constantly proved itself useful for laboratory screening. Furthermore, combinations of FTIR, Raman spectrometry, LC MS, GC MS, XRF, micro XRF and other ones are applied. In the case of identification of post-blast residues, where an investigation is often conducted at the level of separate microscopic particles, the role of SEM is unsubstitutable, whereas the analysis of the organic phase from these often sporadic microparticles has been infeasible until recently. One of the very interesting options appears to be Raman spectrometry technique, which is nowadays obtainable as a supplement to SEM EDX. Newly available is the device that is fully confocal, SEM keeps full functionality and scan range, very high resolution (for green laser resolution 360nm FWHM; 430nm Rayleigh), it is fitted with high quality objective lens, enhances mapping through Raman spectrometry in a volume 250μm x 250μm x 250μm by piezo driven scanner (capacitive feedback linearized) and obtaining a high quality white light image (250μm x 250μm) immediately in the SEM chamber. This technique is currently undergoing intensive testing and it seems that the method could significantly help to address issues with the analysis of organic phases in electron microscopy not only in the case of post-blast residues and explosives.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126681838","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
E. Wiedenmann, Mohsen Afrough, Sven Albert, R. Schott, Jan Tusch, A. Wolf
{"title":"Long wave infrared 3D scanner","authors":"E. Wiedenmann, Mohsen Afrough, Sven Albert, R. Schott, Jan Tusch, A. Wolf","doi":"10.1117/12.2076111","DOIUrl":"https://doi.org/10.1117/12.2076111","url":null,"abstract":"In industrial metrology, the system of fringe projection for the fast determination of 3D surface data has been established. The combination of areal and structured projection with two-dimensional optical sensors and triangulation measurement principle allows very high measurement point densities with reasonable accuracy. There are great difficulties with high gloss surfaces and with very dark surfaces for state of the art systems. Transparent materials cannot be measured using the visible spectrum of light. We have therefore developed a new structured light projection system that solves these problems. For the first time the physical principle of energy conversion is utilized in areal structured light projection. We are presenting first results to show the advantages and the capability of this new measurement principle.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125841898","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
H. Chiamori, Ruth A. Miller, Ateeq J. Suria, N. Broad, D. Senesky
{"title":"Irradiation effects of graphene-enhanced gallium nitride (GaN) metal-semiconductor-metal (MSM) ultraviolet photodetectors","authors":"H. Chiamori, Ruth A. Miller, Ateeq J. Suria, N. Broad, D. Senesky","doi":"10.1117/12.2178091","DOIUrl":"https://doi.org/10.1117/12.2178091","url":null,"abstract":"Ultraviolet (UV) photodetectors are used for applications such as flame detection, space navigation, biomedical and environmental monitoring. Robust operation within large ranges of temperatures, radiation, salinity and/or corrosive chemicals require sensor materials with the ability to withstand and function reliably within these extreme harsh environments. For example, spacecraft can utilize a sun sensor (light-based sensor) to assist with determination of orientation and may be exposed to both ionizing radiation and extreme temperature swings during operation. Gallium nitride (GaN), a wide bandgap semiconductor material, has material properties enabling visible-blindness, tunable cutoff wavelength selection based on ternary alloy mole fraction, high current density, thermal/chemical stability and high radiation tolerance due to the strength of the chemical bond. Graphene, with outstanding electrical, optical and mechanical properties and a flat absorption spectrum from 300 to 2,500 nm, has potential use as a transparent conductor for GaN-based metal-semiconductor-metal (MSM) photodetectors. Here, graphene-enhanced MSM UV photodetectors are fabricated with transparent and conductive graphene interdigitated electrodes on thin film GaN-on-sapphire substrates serving as back-to-back Schottky contacts. We report on the irradiation response of graphene/GaN-based MSM UV photodetectors up to 750 krad total ionizing dose (TID) then tested under dark and UV light (365 nm) conditions. In addition, based on current-voltage measurements from 75 krad to 750 krad TID, calculated photodetector responsivity values change slightly by 25% and 11% at -5 V and -2 V, respectively. These initial findings suggest that graphene/GaN MSM UV photodetectors could potentially be engineered to reliably operate within radiation environments.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"64 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127793219","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Cross-term free based bistatic radar system using sparse least squares","authors":"R. A. Sevimli, A. Cetin","doi":"10.1117/12.2176764","DOIUrl":"https://doi.org/10.1117/12.2176764","url":null,"abstract":"Passive Bistatic Radar (PBR) systems use illuminators of opportunity, such as FM, TV, and DAB broadcasts. The most common illuminator of opportunity used in PBR systems is the FM radio stations. Single FM channel based PBR systems do not have high range resolution and may turn out to be noisy. In order to enhance the range resolution of the PBR systems algorithms using several FM channels at the same time are proposed. In standard methods, consecutive FM channels are translated to baseband as is and fed to the matched filter to compute the range-Doppler map. Multichannel FM based PBR systems have better range resolution than single channel systems. However superious sidelobe peaks occur as a side effect. In this article, we linearly predict the surveillance signal using the modulated and delayed reference signal components. We vary the modulation frequency and the delay to cover the entire range-Doppler plane. Whenever there is a target at a specific range value and Doppler value the prediction error is minimized. The cost function of the linear prediction equation has three components. The first term is the real-part of the ordinary least squares term, the second-term is the imaginary part of the least squares and the third component is the l2-norm of the prediction coefficients. Separate minimization of real and imaginary parts reduces the side lobes and decrease the noise level of the range-Doppler map. The third term enforces the sparse solution on the least squares problem. We experimentally observed that this approach is better than both the standard least squares and other sparse least squares approaches in terms of side lobes. Extensive simulation examples will be presented in the final form of the paper.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"9484 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128667549","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Biomedical sensor design using analog compressed sensing","authors":"Mohammadreza Balouchestani, S. Krishnan","doi":"10.1117/12.2175657","DOIUrl":"https://doi.org/10.1117/12.2175657","url":null,"abstract":"The main drawback of current healthcare systems is the location-specific nature of the system due to the use of fixed/wired biomedical sensors. Since biomedical sensors are usually driven by a battery, power consumption is the most important factor determining the life of a biomedical sensor. They are also restricted by size, cost, and transmission capacity. Therefore, it is important to reduce the load of sampling by merging the sampling and compression steps to reduce the storage usage, transmission times, and power consumption in order to expand the current healthcare systems to Wireless Healthcare Systems (WHSs). In this work, we present an implementation of a low-power biomedical sensor using analog Compressed Sensing (CS) framework for sparse biomedical signals that addresses both the energy and telemetry bandwidth constraints of wearable and wireless Body-Area Networks (BANs). This architecture enables continuous data acquisition and compression of biomedical signals that are suitable for a variety of diagnostic and treatment purposes. At the transmitter side, an analog-CS framework is applied at the sensing step before Analog to Digital Converter (ADC) in order to generate the compressed version of the input analog bio-signal. At the receiver side, a reconstruction algorithm based on Restricted Isometry Property (RIP) condition is applied in order to reconstruct the original bio-signals form the compressed bio-signals with high probability and enough accuracy. We examine the proposed algorithm with healthy and neuropathy surface Electromyography (sEMG) signals. The proposed algorithm achieves a good level for Average Recognition Rate (ARR) at 93% and reconstruction accuracy at 98.9%. In addition, The proposed architecture reduces total computation time from 32 to 11.5 seconds at sampling-rate=29 % of Nyquist rate, Percentage Residual Difference (PRD)=26 %, Root Mean Squared Error (RMSE)=3 %.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"4 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127142254","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Seismic full waveform inversion from compressive measurements","authors":"Ana B. Ramirez, G. Arce","doi":"10.1117/12.2178949","DOIUrl":"https://doi.org/10.1117/12.2178949","url":null,"abstract":"Traditional methods in seismic acquisition require sources and geophones that are uniformly located along a spatial line, using the Nyquist sampling rate. Depending on the area to be explored, it can be necessary to use seismic surveys with large offsets, or decrease the separation between adjacent geophones to improve the resolution, which generates very high volumes of data. It makes the exploration process more difficult and particularly expensive. This work presents the reconstruction of a compressive set of seismic traces acquired using the compressive sensing paradigm where the pair of sources and geophones are randomly located along the spatial line. The recovery of the wavefield from compressive measurements is feasible due to the capabilities of Curvelets on representing wave propagators with only a small set of coefficients. The method first uses the compressive samples to find a sparse vector representation of each pixel in a 2-D Curvelet dictionary. The sparse vector representation is estimated by solving a sparsity constrained optimization problem using the Gradient Projection for Sparse Reconstruction (GPSR) method. The estimated vector is then used to compute the seismic velocity profiles via acoustic Full Waveform Inversion (FWI). Simulations of the reconstructed image gathers and the resulting seismic velocity profiles illustrate the performance of the method. An improvement in the resulting images is obtained in comparison with traditional F-K filtering used in seismic data processing when traces are missing.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127159617","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Analysis of the acoustic response in water and sand of different fiber optic sensing cables","authors":"J. Hofmann, M. Facchini, M. Lowell","doi":"10.1117/12.2178282","DOIUrl":"https://doi.org/10.1117/12.2178282","url":null,"abstract":"Distributed Acoustic Sensing (DAS) is a highly promising technology to efficiently monitor assets for energy production and transportation, both off- and on-shore, such as boreholes, pipelines and risers. The aim of the hereby-presented measurements is to evaluate the sensitivity of the different optical fiber cables to acoustic signals in sand and water, independently from the DAS read-out unit type and manufacturer. Acoustic sensing cables specifically designed by BRUGG Cables are characterized and compared to standard telecommunication cables. The spectral response of each cable was quantified using an all-fiber Mach-Zehnder interferometer. The response was also measured with calibrated microphones in order to convert the measurements into absolute physical units (Pascal). The measurement campaign is part of an investigation program for a reliable DAS system, which comprises the sensing cable (including installation procedure), the interrogator unit and suitable software.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131089441","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Rajesh Ramamurthy, K. Harding, Xiaoming Du, Vincent Lucas, Yi Liao, Ratnadeep Paul, Tao Jia
{"title":"Geometric and topological feature extraction of linear segments from 2D cross-section data of 3D point clouds","authors":"Rajesh Ramamurthy, K. Harding, Xiaoming Du, Vincent Lucas, Yi Liao, Ratnadeep Paul, Tao Jia","doi":"10.1117/12.2179987","DOIUrl":"https://doi.org/10.1117/12.2179987","url":null,"abstract":"Optical measurement techniques are often employed to digitally capture three dimensional shapes of components. The digital data density output from these probes range from a few discrete points to exceeding millions of points in the point cloud. The point cloud taken as a whole represents a discretized measurement of the actual 3D shape of the surface of the component inspected to the measurement resolution of the sensor. Embedded within the measurement are the various features of the part that make up its overall shape. Part designers are often interested in the feature information since those relate directly to part function and to the analytical models used to develop the part design. Furthermore, tolerances are added to these dimensional features, making their extraction a requirement for the manufacturing quality plan of the product. The task of “extracting” these design features from the point cloud is a post processing task. Due to measurement repeatability and cycle time requirements often automated feature extraction from measurement data is required. The presence of non-ideal features such as high frequency optical noise and surface roughness can significantly complicate this feature extraction process. This research describes a robust process for extracting linear and arc segments from general 2D point clouds, to a prescribed tolerance. The feature extraction process generates the topology, specifically the number of linear and arc segments, and the geometry equations of the linear and arc segments automatically from the input 2D point clouds. This general feature extraction methodology has been employed as an integral part of the automated post processing algorithms of 3D data of fine features.","PeriodicalId":438348,"journal":{"name":"Sensing Technologies + Applications","volume":"184 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2015-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114445392","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}