2007 60th Annual Conference for Protective Relay Engineers最新文献

筛选
英文 中文
Tutorial: From the Steinmetz Model to the Protection of High-Inertia Drives 教程:从Steinmetz模型到高惯性驱动器的保护
2007 60th Annual Conference for Protective Relay Engineers Pub Date : 1900-01-01 DOI: 10.1109/psamp.2007.4740919
S. Zocholl
{"title":"Tutorial: From the Steinmetz Model to the Protection of High-Inertia Drives","authors":"S. Zocholl","doi":"10.1109/psamp.2007.4740919","DOIUrl":"https://doi.org/10.1109/psamp.2007.4740919","url":null,"abstract":"The thermal limitations of induction motors are specified by thermal limit curves that are plots of the limiting temperature of the rotor and stator in units of I2t. This paper discusses the thermal protection provided by rotor and stator thermal models defined by the thermal limit curves and supporting motor data. The thermal model is the time-discrete form of the differential equation for temperature rise due to current and is derived from fundamental principles as shown in the Annex. In the rotor model, voltage and current are used to derive the slip-dependent I2r watts that permit the safe starting of high-inertia drive motors","PeriodicalId":438320,"journal":{"name":"2007 60th Annual Conference for Protective Relay Engineers","volume":"20 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130248448","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Implementing the Future Today in Naperville, Illinois 在伊利诺伊州内珀维尔市实施未来
2007 60th Annual Conference for Protective Relay Engineers Pub Date : 1900-01-01 DOI: 10.1109/cpre.2007.359909
D. Gacek
{"title":"Implementing the Future Today in Naperville, Illinois","authors":"D. Gacek","doi":"10.1109/cpre.2007.359909","DOIUrl":"https://doi.org/10.1109/cpre.2007.359909","url":null,"abstract":"This paper deals with the initiative to move future technology into the present, by the city of Naperville by implementing one of the first IEC 61850 substations. The specification which has been standardized on and implemented in their last eight (8) substations includes Siemens 75J63 multifunction feeder protective relays connected to a SICAM SAS automation system communicating via Profibus FMS at 1.5 Mb/s","PeriodicalId":438320,"journal":{"name":"2007 60th Annual Conference for Protective Relay Engineers","volume":"78 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131008162","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
AEP Experience With Protection of Three Delta/Hex Phase Angle Regulating Transformers 三台三角/六角相角调节变压器的AEP保护经验
2007 60th Annual Conference for Protective Relay Engineers Pub Date : 1900-01-01 DOI: 10.1109/psamp.2007.4740903
M. Thompson, H. Miller, J. Burger
{"title":"AEP Experience With Protection of Three Delta/Hex Phase Angle Regulating Transformers","authors":"M. Thompson, H. Miller, J. Burger","doi":"10.1109/psamp.2007.4740903","DOIUrl":"https://doi.org/10.1109/psamp.2007.4740903","url":null,"abstract":"American Electric Power installed three 138 kV, 150 MVA delta/hex phase angle regulating (PAR) transformers on the south Texas transmission grid during 2006. These transformers help optimize power flow on the transmission grid until planned 345 kV line construction projects can be completed to improve the strength of the grid in this portion of the power system. The delta/hex PAR transformer is a new single-tank design that promises to be much more economical to build and install than previous designs-improving the economic viability of deployment of these devices on the transmission grid. This paper addresses the challenges of providing fully redundant, sensitive, and secure protection for all types of faults, including turn-to-turn faults in this type of transformer and its surrounding bus work. The protection system includes a mix of conventional protection concepts and a completely new differential protection system that can compensate for the variable phase angle shift introduced by operation of the PAR transformer. The complete protection system was tested using digital model power system transient testing prior to installation in the field","PeriodicalId":438320,"journal":{"name":"2007 60th Annual Conference for Protective Relay Engineers","volume":"38 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130795151","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信