K. Methaprayoon, W. Lee, P. Didsayabutra, J. Liao, R. Ross
{"title":"Neural network-based short term load forecasting for unit commitment scheduling","authors":"K. Methaprayoon, W. Lee, P. Didsayabutra, J. Liao, R. Ross","doi":"10.1109/ICPS.2003.1201499","DOIUrl":"https://doi.org/10.1109/ICPS.2003.1201499","url":null,"abstract":"Today's electric power industry is undergoing many fundamental changes due to the process of deregulation. In the new market environment, the power system operation will become more competitive. The utilities are required to perform optimal planning in order to operate their system efficiently. The accuracy of future load forecast becomes crucial. This paper presents the development of an artificial neural network-based short-term load forecasting (STLF) for unit commitment scheduling and resource planning. The network structures are carefully tuned to obtain satisfying forecast results according to the load characteristics of the target utility system. The result indicates that ANN forecaster provides more accurate result and can be modified to satisfy the target utility's requirement.","PeriodicalId":437400,"journal":{"name":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2003-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129872553","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Wendai Wang, E.R. Furlong, R. Arno, P. Vassiliou, D. Ogden
{"title":"Apply simulation technique via reliability block diagram to Gold Book Standard Network","authors":"Wendai Wang, E.R. Furlong, R. Arno, P. Vassiliou, D. Ogden","doi":"10.1109/ICPS.2003.1201486","DOIUrl":"https://doi.org/10.1109/ICPS.2003.1201486","url":null,"abstract":"This is one of a series of papers discussing the application and accuracy of different analysis techniques supporting the determination of industrial and commercial power system reliability and availability. There is a need recognized in the power industry to identify and utilize a standard tool, or a set of tools to analyze the reliability of industrial and commercial power systems. Historically, the results of different reliability methodologies/tools varied significantly and comparisons were extremely difficult. The Reliability Analysis Techniques Working Group of Gold Book (i.e., IEEE Std. 493) developed a standard network to enable comparison of analytical techniques. This paper identifies an alternative approach, simulations via a generalized reliability block diagram, and applies this approach to the Gold Book standard network configuration. Reliability indices of the load points obtained from this approach are presented, and can be compared with ones obtained from the other techniques in the series to determine the accuracy of these analytical techniques.","PeriodicalId":437400,"journal":{"name":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","volume":"41 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2003-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116315683","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Simplifying IEEE/ANSI and IEC fault point X/R ratio for breaker evaluation","authors":"K. Dartawan, C. St. Pierre","doi":"10.1109/ICPS.2003.1201498","DOIUrl":"https://doi.org/10.1109/ICPS.2003.1201498","url":null,"abstract":"ANSI/IEEE and IEC standards provide procedures that do a fairly good job in obtaining a single fault point X/R ratio that will allow a conservative estimate of the DC component and therefore the total fault current flowing in a breaker. However, there are circuit configurations that result in overly conservative or under conservative estimates of the fault X/R ratio. This paper explores alternate methods using the information in a complex impedance network reduction and presents an alternate method that provides comparable X/R ratios and conservatism without the need to preform time consuming dual network reductions.","PeriodicalId":437400,"journal":{"name":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2003-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126069279","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Microprocessor-based instrument for predicting the incident energy from arc flash hazards","authors":"T. Baldwin, M.J. Hittel, L. Saunders, F. Renovich","doi":"10.1109/ICPS.2003.1201493","DOIUrl":"https://doi.org/10.1109/ICPS.2003.1201493","url":null,"abstract":"With better understanding of arc flashes, the electrical safety industry continues to develop new safety procedures for electrical workspaces. To assess the potential arc hazards of a workspace, workers must rely on engineering fault studies to provide vital fault-current data. An instrument, based on a network impedance analyzer, determines the maximum flash-arc incident-energy exposure at a worksite within a few seconds. The digital analyzer measures the power system source impedance, X/R ratio, and the system voltage to predict the bolted fault current and incident energy, while the power distribution system is energized and in normal operation. The instrument computes the incident energy for standard electrical workspaces of an open air arc and an enclosed box with one open side. Experiments have been conducted to verify the accuracy of the impedance and X/R ratio measurements.","PeriodicalId":437400,"journal":{"name":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","volume":"186 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2003-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121988939","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"IEEE standard 1459: a long overdue document [power quality]","authors":"A. Eĭgeles","doi":"10.1109/ICPS.2003.1201488","DOIUrl":"https://doi.org/10.1109/ICPS.2003.1201488","url":null,"abstract":"This paper describes the new IEEE Standard 1459, Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced or Unbalanced Conditions. The information is presented in context of historical events that explain the reasons for new definitions. The new definitions originate from S/sub e/, the effective apparent power definition attributed to F. Buchholz and W. Goodhue. The resolution of S/sub e/ extends from well-established concepts. The need for the separation of 60/50 Hz powers from the non-60/50 Hz powers is emphasized. The standard serves users who want to evaluate the performance of modern equipment or to design and build the new generation of instrumentation.","PeriodicalId":437400,"journal":{"name":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2003-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133437333","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Power factor correction and energy saving with proper transformer and phase shifting techniques","authors":"J. Boudrias, J. Bannard","doi":"10.1109/ICPS.2003.1201480","DOIUrl":"https://doi.org/10.1109/ICPS.2003.1201480","url":null,"abstract":"Harmonics in electrical distribution systems are created from a number of sources, and produce a variety of undesirable side effects, therefore it is important to understand all solutions that are available. Phase shifting is reviewed as one concept for solving certain types of problems related to power quality. Both theoretical concepts and a case study are presented.","PeriodicalId":437400,"journal":{"name":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","volume":"117 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2003-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124549791","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Protection, metering, monitoring and control of medium voltage power systems","authors":"B. Duncan, B. Bailey","doi":"10.1109/ICPS.2003.1201497","DOIUrl":"https://doi.org/10.1109/ICPS.2003.1201497","url":null,"abstract":"Traditional practices for industrial and commercial medium voltage power systems to provide protection, metering, monitoring, control, power quality analysis, disturbance recording and automation have changed. The introduction of new multifunction numerical protection relays using the processing power of the present generation of microprocessors, have very high functionality. Many functions can be integrated into one device, allowing new power system problem solving capabilities while permitting significant cost savings as compared with discrete protective relays, instruments, meters, recorders and transducers of the past. This paper describes the vast capabilities and enhancements of these devices, which are called intelligent electronic devices (IEDs) in this paper. Included are anecdotes obtained from an installation on a large industrial power system.","PeriodicalId":437400,"journal":{"name":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2003-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122408293","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Reliability of various industrial substations","authors":"Zenfu Dong, D. Koval, J. Propst","doi":"10.1109/ICPS.2003.1201487","DOIUrl":"https://doi.org/10.1109/ICPS.2003.1201487","url":null,"abstract":"Many utility and industrial substation configurations have been designed to interconnect energy sources and individual industrial load points. The design, protection schemes and operating procedures of a substation configuration directly affect the reliability of the power supply to these load points. When an existing or planned substation configuration is unreliable, the question is: which substation configuration will be more reliable? Another question is: what reliability methodology will account for the protection schemes in place, the operating procedures and the common cause failures of utility supplies? This paper will discuss and present a reliability analysis of eight basic industrial substation configurations that are typically used inside process plants. The zone branch reliability methodology is used to calculate load point reliability indices of each substation configuration. The reliability analysis includes open and short-circuit failure modes of circuit protective devices, operating practices and common cause failures or utility supplies. The significant impact of common cause utility supply failures on load point reliability levels will be presented and discussed in detail.","PeriodicalId":437400,"journal":{"name":"IEEE Technical Conference on Industrial and Commercial Power Systems, 2003.","volume":"93 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123576006","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}