{"title":"Failure modes and field testing of medium voltage motor windings","authors":"R. Gleichman","doi":"10.1109/PAPCON.2001.952952","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952952","url":null,"abstract":"Reliable electrical motor performance is vital to profitable plant operation. Although motor maintenance spending constitutes the largest component (50-70%) of electrical maintenance budgets, its cost is relatively small compared to the lost opportunity costs of most driven equipment in pulp and paper processes. Based upon a 1983 EPRI study, 37% of electrical motor failures can be attributed to stator problems. The other 63% (rotating assemblies, including bearings) are susceptible to imbalance, misalignment, and other mechanical problems that can be diagnosed and mitigated through the proper application of vibration monitoring, tribology, and other well known practices. This paper focuses on evaluating the condition of stator windings. To minimize the cost of motor ownership and optimize opportunity, it is essential to have a reasonable understanding of a motor's condition and its residual life. This can be accomplished using several different testing methods, ranging from on-line monitoring to off-line testing. One word of warning is in order. Although many popular test methods are valid, some are misleading and of little practical value. What follows is an explanation of common winding failure modes, and some results of common tests and technologies.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116627989","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Failure contributors of MV electrical equipment and condition assessment program development","authors":"G. Paoletti, M. Baier","doi":"10.1109/PAPCON.2001.952946","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952946","url":null,"abstract":"Implementation of condition assessment, or condition-based-maintenance involves many disciplines such as failure analysis, on-line diagnostics, diagnostic data interpretation, management and communication, follow-up corrective actions and lastly the program maintenance. One of the difficult areas in the development of a comprehensive condition assessment program is the analysis of the probable contributing causes of failures, and selection of the appropriate on-line diagnostic tools to address the correct failure contributors. The specific failure contributors of the electrical power transmission and distribution equipment are documented in various sources, such as IEEE. This paper illustrates the process of development of a comprehensive condition assessment program for medium voltage switchgear using the statistical data pertaining to the equipment failure contributing causes. Particular attention is given to the selection of specific on-line diagnostic techniques that are available today and that address the specific failure contributors. Presented only briefly is the outage costs and RCM (reliability centered maintenance) concepts, related to a condition assessment program.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"94 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129431283","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Carbon brush performance and application in the pulp and paper environment","authors":"R. Roberge","doi":"10.1109/PAPCON.2001.952968","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952968","url":null,"abstract":"Direct current (DC) motors are used extensively throughout the pulp and paper industry. These motors are used in various applications such as fan pumps, press and winder motors. The maintenance requirements of the motors are different for each application. An important maintenance function regularly performed is the inspection of carbon brushes and commutators. Carbon brushes are critical to the operation of the paper machine with DC motors. Worn or failed brushes can make a paper machine inoperable and cost thousands of dollars per hour. This paper discusses the different theories used for carbon brush application in the paper industry. The strength and weaknesses of each brush application theory are also addressed. In the end the \"black magic\" of carbon brushes is revealed. The goal of this paper is to educate new and old maintenance personnel on carbon brush and commutator performance criteria and upkeep, hence reducing overall maintenance cost.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131119115","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Silver corrosion and whiskers growth on power contacts in industrial atmosphere of pulp and paper plants","authors":"B. Chudnovsky, D. L. Swindler, J.R. Thompson","doi":"10.1109/PAPCON.2001.952963","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952963","url":null,"abstract":"Extensive silver corrosion and growth of silver whiskers was found on power contacts of low voltage breakers at a recycle pulp plant in Minnesota. The phenomenon can be extremely hazardous. The plant experienced a number of failures of circuit breakers in 1999-2000 caused by strong overheating. Metallic whiskers were found growing from heavily corroded silver-plated copper surfaces of the power contacts virtually everywhere but mostly from the edges and corners. The length of the two-month old whisker reaches several inches (5-10 cm) and the thickness of the filament is up to 0.04\" (/spl sim/1 mm). Using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) we have determined morphology and chemical composition of the whiskers. Most of the whiskers are made of 97-99% silver with 1-3% of copper. The surface of the larger whiskers is covered with silver sulfide. To determine the means of controlling and minimizing the hazardous phenomenon, the major factors initiating and accelerating the mechanism of whisker growths have been thoroughly investigated.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116970823","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"What is in store for DCS systems? Where are they headed?","authors":"D. L. Decker","doi":"10.1109/PAPCON.2001.952943","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952943","url":null,"abstract":"The advances in microelectronics in the form of large scale integrated circuits have enabled manufactures of distributed control systems (DCS) to make their packages smaller and more reliable. In addition, new innovative communications systems and networks have combined to allow true distributed control to field devices. The future of DCS is directed towards full network functionality. Pure discrete inputs may only be used in situations where immediate inputs and outputs are required because of speed. This need for immediate inputs are few and far between for most mill processes. New processors are faster and scan rates can be as fast as 200 microseconds from sensed input to full output. These circumstances can be handled with discrete input/output modules in the main processor rack. Even in small control systems the benefit is real. Networks as mentioned can save wiring costs and offset the cost of the intelligent devices.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133950473","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Applying human factors in graphical operator interfaces","authors":"S. K. Hall, K. Cockerham, D. Rhodes","doi":"10.1109/PAPCON.2001.952974","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952974","url":null,"abstract":"This paper is an overview of the factors to be considered in designing a graphical operator interface, in order to make the interface more usable. The factors considered are: understanding the end user; functionality; consistency; ease of use; clarity including correct use of colour; visual harmony (balanced display); text; and ISO 9241, usability standard.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124209568","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Selection of best induction motor rotor construction method","authors":"W. Finley, M. Hodowanec","doi":"10.1109/PAPCON.2001.952947","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952947","url":null,"abstract":"On squirrel cage induction motors, there is an important choice between utilizing a lower cost die cast or fabricated aluminum rotor versus the more expensive copper bar rotor. Utilizing the wrong rotor construction for the application can either increase costs unnecessarily or lead to catastrophic failure. This paper provides the background necessary to assist in making the proper choice. The fundamentals of rotor construction and basic information on how the induction motor works are discussed. Additionally, the effects of various materials and types of rotor construction on motor performance are analyzed.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115808358","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electrical safety programs","authors":"K. Eastwood, D. Liggett, E. Hesla","doi":"10.1109/PAPCON.2001.952957","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952957","url":null,"abstract":"An electrical safety program is a plan designed so that neither workplace conditions, nor the actions of people, expose personnel unnecessarily to electrical hazards. Employers should develop and implement an electrical safety program to give overall safety directions for facility activities related to electrical work. Effective electrical safety programs are a major key in preventing electrical incidents. This paper is based on best practices in developed countries, primarily in the United States as outlined in the IEEE Yellow Book: Guide for Maintenance, Operation and Safety of Industrial and Commercial Power Systems. The purpose is to provide employers the recommended tools to establish an electrical safety policy.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"110 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132767811","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Motor repair specifications and repair-replace options for forest products and other industries","authors":"A. Bonnett, C. Yung","doi":"10.1109/PAPCON.2001.952970","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952970","url":null,"abstract":"There are several general industry repair standards and guidelines currently available. The repair industry is largely represented by the Electrical Apparatus Service Association (EASA), headquarted in St. Louis, Missouri. EASA serves 2500 members worldwide and has developed standards and guidelines dealing with the repair and service of electric motors. This paper presents the basic sources of a motor service and repair guideline and is built upon the experience of the EASA organization and its membership. Applicable elements from other guidelines and standards have also been incorporated. The scope of this paper deals with squirrel-cage induction motors in the 1 to 3000 horsepower range-those typically found in the forest products industry. This paper examines the repair or replacement of the stator, rotor, shaft, bearings, fans and mechanical parts (hardware and accessories). Attention is also given to testing, verification, analysis and possible corrective actions to prevent or eliminate future failures. Options for motor replacement are also considered.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"66 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129127316","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"The importance of power quality management in the pulp and paper industry","authors":"B. Nacke, R. Schlake","doi":"10.1109/PAPCON.2001.952965","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952965","url":null,"abstract":"The manufacturing imperative of improving uptime presents a number of unique challenges for the plant engineer or industrial facilities manager. The first challenge is to debunk the myths and misconceptions surrounding power conditioning and environmental protection in industrial settings. Like their office system counterparts, control systems are running more mission-critical applications than ever before. Uptime demands are increasing. This, in turn, increases the need for systems availability and reliability 24 hours a day, seven days a week. Pulp and paper mills are continually striving to obtain data center reliability through the use of dual corded loads fed from separate substations. Building in high degrees of redundancy increases the standards for reliable power and provides the ability to perform consistent maintenance for all power and environmental equipment-continuous availability is dependent upon it. This presentation covers how to identify the most common challenges-from power conditioning to site monitoring issues to precision air conditioning and other environmental factors-and then configures the best solution for a specific environment.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123404160","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}