{"title":"Motor bearing systems for forest products applications","authors":"A. Bonnett, T. Albers","doi":"10.1109/PAPCON.2001.952953","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952953","url":null,"abstract":"Numerous bearing systems are used in the electric motor industry. These systems even vary for a given manufacturer based upon the motor size, type, enclosure, speed and application. This paper focuses on anti-friction rolling element, grease or oil lubricated bearings used in both vertical and horizontal motors. The primary focus is on industrial applications that use the more traditional types of bearings, lubricating systems and enclosures. It is acknowledged that there are other specialized bearings in operation and that there are other types of machinery where the principles of the paper may have application. A comparison is made between the different types of bearing systems available. Loading, speed, coupling and life factors are considered. The various methods of lubrication, sealing, mounting, and clamping are reviewed. Recommendations are given for a wide variety of industrial applications.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114379745","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Proper use of active harmonic filters to benefit pulp and paper mills","authors":"J. Johnson","doi":"10.1109/PAPCON.2001.952944","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952944","url":null,"abstract":"This paper is a basic primer for defining and applying active harmonic filters. Active harmonic filters (AHFs) are sophisticated electronic devices that offer significant advantages over traditional harmonic mitigation and displacement power factor correction methods. This paper introduces the AHF and discusses when and where these advantages apply. Additionally, the simplicity in selection of the AHF discussed. The author presents specific examples for the various applications to which AHFs have been applied.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114590191","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Proper grounding for the automation industry","authors":"A.W. Rebeck","doi":"10.1109/PAPCON.2001.952954","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952954","url":null,"abstract":"Improper grounding accounts for up to 40 percent of costly power related problems to sensitive equipment utilized in the forest products, petroleum, mining and automotive industries including damage and downtime. A single point grounding system can be essential for minimizing this downtime and reducing lightning damage to PLCs. This paper discusses the concepts of single point grounding practices and the proper application of isolated, ring and halo grounds at industrial sites employing state of the art automation techniques.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130246880","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Information integration in the modern pulp and paper industry","authors":"G. Xiong, Gang-Yu Xiong, T. Nyberg","doi":"10.1109/PAPCON.2001.952956","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952956","url":null,"abstract":"Like other types of industry, the modern pulp and paper industry (MPPI) is applying more modern information technologies and management technologies, and is integrating the different function sub-systems and production processes to realize intelligent and integrated production. This task is very complex thus useful theories, technologies and methods are needed to provide help. At the same time, fierce competition in today's global markets and the heightened expectations of customers' need in TQCS (time, quality, cost and service), CIMS (computer integrated manufacturing systems) technology can help MPPI to win market share from competitors. CIMS-oriented information integration technology is the key control technology of MPPI. This paper mainly discusses the information integration of the modern pulp and paper industry. Firstly, the characteristics and requirement of modern pulp and paper industry for information integration are introduced. Next, information integration and its key technologies are discussed, in the meantime, the paper gives the hierarchy of CIMS-oriented process integration of MPPI. Then, the integrated information framework of MPPI is put forward.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"52 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133370884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Coordination of surge arresters with medium voltage current limiting fuses","authors":"J. Das","doi":"10.1109/PAPCON.2001.952969","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952969","url":null,"abstract":"Current limiting fuses are commonly used for unit substation primary protection. Simultaneously surge arresters are also provided on the primary side of the transformers, more so for the dry type transformers. The arc voltages generated by current limiting fuses will store energy in the inductive elements of a distribution system. This stored energy divides between the current limiting fuse and surge arrester and the surge arrester may operate. The paper outlines a procedure to calculate the energy diverted to the surge arresters, and shows that in some cases surge arresters may fail on operation of the current limiting fuses. Guidelines are developed for selection and application of the surge arresters at 13.8 kV, 4.16 kV and 2.4 kV voltage levels.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125262435","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
E. Wiedenbrug, A. Ramme, E. Matheson, A. Jouanne, Alan K. Wallace
{"title":"Modern on-line testing of induction motors for predictive maintenance and monitoring","authors":"E. Wiedenbrug, A. Ramme, E. Matheson, A. Jouanne, Alan K. Wallace","doi":"10.1109/PAPCON.2001.952964","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952964","url":null,"abstract":"On-line testing of motors, diagnostics and motor monitoring have shown large scientific development in the past few years, outgrowing the stage of RMS current and voltage measurements. This stems from current and voltage signature analysis which has progressed from the laboratory and the work of dedicated specialist experts to become the base for modern instrumentation available to plant operatives. In addition to line fed motors, a clear view of variable frequency drive applications is now possible without requiring connection directly to the motor terminals. The use of the motor itself as a transparent sensor, making shaft torque signatures available at the motor control cabinet, allows for advanced diagnostics of the voltage supply, motor and load system.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"121 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115159639","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Increasing the electrical output of a cogeneration plant","authors":"D. M. Paine","doi":"10.1109/PAPCON.2001.952955","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952955","url":null,"abstract":"This paper provides a technical description of the electrical system for an operating gas turbine-based combined cycle power plant for a pulp and paper mill. The control and electrical challenges associated with adding a steam turbine-generator to the plant are discussed. The addition of switchgear, the bus and cable system, transformer tap settings, protective relaying issues, distributed control system upgrade, and starting are discussed.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127112840","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Considerations in application and selection of unit substation transformers","authors":"C. J. Nochumson","doi":"10.1109/PAPCON.2001.952971","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952971","url":null,"abstract":"This paper discusses secondary unit substations transformers (USTs) ranging from 300 kVA up through 2500 kVA with 34.5 kV maximum primary voltages and with secondary voltages 600 volts and below. The first part of this paper discusses USTs belonging to two general categories, liquid-type and dry-type (nonliquid type). Liquid types include a discussion of the presently available insulating fluids: mineral oil, high temperature hydrocarbon fluid, silicone fluids and the new vegetable based fluids. Dry types include a discussion of VPI polyester, VPE silicone, partial cast and full cast insulation systems. National Electric Code (NEC) 1999 requirements as they affect both liquid and dry type USTs for both outdoor and indoor locations are considered. The second part of the paper discusses the relative advantages of each UST within each category with respect to first cost, operating costs (losses), overload capability, fan cooling, space factor, environmental factors, sound levels and maintenance.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122874921","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Bearing fluting in AC motors, DC motors and rolls on paper machines","authors":"H. E. Boyanton, G. Hodges","doi":"10.1109/PAPCON.2001.952958","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952958","url":null,"abstract":"When unexpected bearing losses were questioned at a paper mill, work began at the mill that led to a long-term investigation to determine the causes and incidence of a type of bearing damage called \"bearing fluting.\" It was discovered that many paper machines have bearing fluting and that this has caused significant down time and increased maintenance costs. Additionally, bearing fluting was found to be associated with the use of AC or DC sectional variable speed control. This problem is not new, but the understanding of its origin, magnitude and treatment has improved over the past couple of years. A number of ways to control the problem were investigated. Bearing fluting was found to be readily controllable with proper application of shaft grounding thereby eliminating a significant source of lost operating time and associated maintenance costs.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"132203882","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Maintenance concerns for good operation of DC motors","authors":"G. E. Lozowski","doi":"10.1109/PAPCON.2001.952972","DOIUrl":"https://doi.org/10.1109/PAPCON.2001.952972","url":null,"abstract":"Successful long-term operation of DC motors and generators, like any piece of industrial equipment, needs maintenance. Scheduled periodic visual inspections and the recording of this data is valuable information when reviewing that machines' performance. These written inspection reports perform much better than the memory of the maintenance technician or supervisor when questioning the performance history of a certain piece of equipment. A generic inspection record format is included along with guidelines to help make decisions on the health status of these motors. This paper expands on 10 major items of concern for successful long-term operation of DC machines.","PeriodicalId":432079,"journal":{"name":"Conference Record of 2001 Annual Pulp and Paper Industry Technical Conference (Cat. No.01CH37209)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116359552","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}