E. A. Dijkstra, W. Olthuis, J. Bomer, P. Bergveld, D.A. Kronemeijer
{"title":"Fabrication and packaging of a miniature sensor array for harsh environments","authors":"E. A. Dijkstra, W. Olthuis, J. Bomer, P. Bergveld, D.A. Kronemeijer","doi":"10.1109/MEMSC.2001.992731","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992731","url":null,"abstract":"This paper describes the fabrication of devices to be used in harsh environments. The devices should operate under extreme conditions: high temperature (180/spl deg/C), high pressure (200 bar) and in a chemically aggressive environment. Therefore, packaging is a major concern. Sensor fabrication and packaging is described. Two devices were made and tested at the temperature and pressure mentioned above.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"190 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128190202","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
A. de Silva, C. Vaughan, D. Frear, L. Liu, S. Kuo, J. Foerstner, J. Drye, J. Abrokwah, H. Hughes, C. Amrine, C. Butler, S. Markgraf, H. Denton, S. Springer
{"title":"Motorola MEMS switch technology for high frequency applications","authors":"A. de Silva, C. Vaughan, D. Frear, L. Liu, S. Kuo, J. Foerstner, J. Drye, J. Abrokwah, H. Hughes, C. Amrine, C. Butler, S. Markgraf, H. Denton, S. Springer","doi":"10.1109/MEMSC.2001.992733","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992733","url":null,"abstract":"Motorola Semiconductor Products Sector (SPS) has made significant progress in developing an integrated MEMS switch network for use in next-generation portable wireless systems. This MEMS switch technology has significantly better RF characteristics than conventional PIN diodes or FET switches and consumes less power. The RF MEMS switch exhibits insertion loss under 0.3 dB, isolation greater than 50 dB, and operating power under 200 /spl mu/W. The RF MEMS switch chip is integrated with a high voltage charge pump plus control logic chips into a single package that provides a network system to accommodate low voltage requirements in portable wireless applications.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122003318","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A fast method for analysis and modeling of optical MEMS switches","authors":"M. Basha, A. Rohani, S. Safavi-Naeini","doi":"10.1109/MEMSC.2001.992741","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992741","url":null,"abstract":"A fast and accurate method for modeling and analysis of optical MEMS switches is developed. The method is a combination of BPM, 3D-Gaussian beam tracing (GBT), physical optics, and electromagnetic reciprocity theory. The initial results show a great agreement between the simulated and measurement results for three different structures.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130769787","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
V. Pamula, P. Paik, J. Venkatraman, M. Pollack, R. Fair
{"title":"Microfluidic electrowetting-based droplet mixing","authors":"V. Pamula, P. Paik, J. Venkatraman, M. Pollack, R. Fair","doi":"10.1109/MEMSC.2001.992729","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992729","url":null,"abstract":"We present a liquid droplet mixer to enable mixing of the samples and reagents for chemical and biological analysis in micro total analysis systems (/spl mu/TAS). The droplets in the mixer are actuated based on electrowetting phenomenon. The actuator comprises of two parallel glass plates between which the droplet is actuated on a planar array of electrodes. Mixing of liquid channels in microfluidic systems has been demonstrated for continuous flow systems where the mixing is diffusion-limited due to the laminar flow of liquids, requiring very long, thin channels. In the present paper, mixing is performed on discrete droplets of liquid. When two droplets are brought together, depending on the velocity of the moving droplets, surface tension, viscosity, electrode activation, and volume among other factors, turbulence is created which aids in mixing. The mixing is not limited by diffusion and enhanced by transport. The mixing experiments are performed between fluorescein and plain water droplets whose individual volume is 1.75 /spl mu/l. Mixing is visualized with a 2-CCD camera setup to observe both the top and side views, with appropriate filters to capture fluorescence. We observed that it takes about 60 seconds for two droplets of 1.75 /spl mu/l each to mix when their surface tensions are different and it takes about 90 seconds when the two droplets have similar surface tensions. The present mixer stands apart from any current conventional micromixers in that the mixing times occupies much lesser area, mixing does not need any specific architecture on the chip and can be performed on any transport electrodes dynamically assigned to mixing.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125216999","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A MEMS device for measurement of skin friction with capacitive sensing","authors":"Jiang Zhe, K. Farmer, V. Modi","doi":"10.1109/MEMSC.2001.992728","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992728","url":null,"abstract":"A microfabricated floating-element sensor for the measurement of wall shear stress is developed. The design objective is to measure shear stress in the range of 0.1 to 2 Pa, with a spatial resolution of O(100 /spl mu/m). The sensor is micromachined in an ultra-thin silicon wafer using wafer bonding and DRIE techniques. Preliminary test results have been obtained by applying an electrostatic force to the sensor instead of a fluid force. The floating element deflection is then measured using direct and differential capacitance techniques as well as an optical method for additional confirmation of the results. These test results have been compared to theoretical simulations using MEMCAD software. The results show that with this sensor design it is possible to measure a shear force as small as 5 nN /spl plusmn/ 0.5 nN, corresponding to a shear stress level of 0.05 Pa /spl plusmn/ 0.005 Pa.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"65 2 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114054914","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
S. Hong, Zhongliang Tang, D. Djukic, A. Tucay, S. Bakhru, R. Osgood, J. Yardley, A. West, V. Modi
{"title":"Simulation and experimental validation of electroosmotic flow in a microfluidic channel","authors":"S. Hong, Zhongliang Tang, D. Djukic, A. Tucay, S. Bakhru, R. Osgood, J. Yardley, A. West, V. Modi","doi":"10.1109/MEMSC.2001.992745","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992745","url":null,"abstract":"Steady electroosmotic and pressure driven flows in geometries of interest to biomacromolecular detection are considered. For both types of flow, experimental data are obtained by imaging fluorescent dye propagation. Numerical simulations are carried out using finite volume methods. Test structures are made of polydimethylsiloxane (PDMS) mold using the negative of the desired structure fabricated by SU-8 thick negative photoresist. Steady electroosmotic flow is governed by the Laplace equation under certain idealized conditions such as when the Helmholtz-Smoluchowski relation is satisfied at the inlet and outlet boundaries, and when the zeta potential is uniform across the domain. Electroosmotic fluid flow can be further idealized as two-dimensional when two parallel plates confine the flow. Such conditions are frequently encountered in many microfluidic devices. Numerical solutions of such an idealized two-dimensional electroosmotic flow are obtained. Equations describing the transient dye propagation are then solved in a straight channel followed by a downstream circular well. Effects of channel size, electric field and possible pressure driven flow components are explored.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125293597","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Advanced lithography for high aspect ratio MEMS technology","authors":"R. Islam, C. Brubaker","doi":"10.1109/MEMSC.2001.992746","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992746","url":null,"abstract":"MEMS (microelectromechanical systems) devices require thick and high aspect ratio film processing for their novel microstructures. The development of high-aspect-ratio processing, in which the vertical dimensions can be large compared to the lateral dimensions, has made it possible to move from planar to three-dimensional micromechanical structures. High aspect ratio microstructures can The fabricated by deep X-ray lithography, energy beams and physical cutting tools, and replication in metals, plastics, and ceramics. is paper investigated fabrication methods for high aspect ratio microstructures.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125188812","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Probe-based recording technology: a MEMS perspective","authors":"S. Naberhuis","doi":"10.1109/MEMSC.2001.992736","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992736","url":null,"abstract":"The invention of the scanning tunneling microscope (STM) prompted researchers to contemplate whether such technology could be used as the basis for the storage and retrieval of information. With magnetic data storage technology facing limits in storage density due to the thermal instability of magnetic bits, the super-paramagnetic limit, the heir-apparent for information storage at higher densities appeared to be variants of the STM or similar probe-based storage techniques such as atomic force microscopy (AFM). Among these other techniques that could provide replacement technology for magnetic storage, near-field optical scanning optical microscopy (NSOM or SNOM) has also been investigated. Another alternative probe-based storage technology, called atomic resolution storage (ARS) is also currently under development. An overview of these various technologies is herein presented, with an analysis of the advantages and disadvantages inherent in each particularly with respect to reduced device dimensions. The role of microelectromechanical systems (MEMS) is emphasized.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"122179884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
L. Robert, V. Laude, S. Basrour, W. Daniau, T. Pastureaud, S. Ballanchras
{"title":"Electroacoustic interaction between SAW and vibration modes of high-aspect-ratio electrodes built using LIGA-UV techniques on singly rotated lithium niobate wafers","authors":"L. Robert, V. Laude, S. Basrour, W. Daniau, T. Pastureaud, S. Ballanchras","doi":"10.1109/MEMSC.2001.992738","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992738","url":null,"abstract":"It has been shown theoretically and demonstrated experimentally that shear horizontal surface waves can exist when the surface of an isotropic substrate is perturbed by a strong corrugation, for instance consisting of deep grooves etched in the substrate, whereas these waves cannot exist without this perturbation. In this work, we analyze the behavior of surface acoustic waves with general polarization propagating under a periodic array of metallic electrodes with large aspect ratio, deposited over a piezoelectric substrate. In this case, we had previously predicted the existence of generally polarized higher order surface modes. We have constructed high-aspect-ratio interdigital transducers (IDTs) on Y+128 lithium niobate using electroplating techniques. We have observed the existence of higher order surface modes using electrical measurements of the admittance of the IDTs. The predicted and experimental results agree reasonably well, although more work is required to fully understand the properties of these higher order surface modes of high-aspect-ratio IDTs.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123199875","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Micromachined piezoelectric ultrasonic imaging transducer","authors":"H. Mohamed, D. Polla, E. Ebbini, S. Zurn","doi":"10.1109/MEMSC.2001.992751","DOIUrl":"https://doi.org/10.1109/MEMSC.2001.992751","url":null,"abstract":"A MEMS ultrasonic transducer, based on thin film PZT membrane has been designed and successfully fabricated. This paper presents the design, fabrication, analysis, and testing results of the membrane devices. The transducers are square membranes, where silicon nitride is the supporting layer, with a piezoelectric capacitor structure of lead zirconium titanate (PZT), deposited on top. The PZT structure enables the actuation and sensing of ultrasonic waves. The thin film PZT was spin-coated on the device using a metal-organic deposition method, resulting in PZT thickness of 0.4 /spl mu/m. The average remanent polarization (+Pr) of the PZT was measured at 23.5 /spl mu/C/cm/sup 2/ with an average dielectric constant (K) of 1552. The membranes were individually released by a deep reactive ion etching (DRIE) of the back of the Si substrate, resulting in a structure with minimal crosstalk between the different elements when fabricated in arrays. Modal analysis was performed for the transducers on ANSYS. Simulation and experimental results match perfectly. The acoustic impedance, phase and impulse response for the transducers were calculated using KLM and Reeder-Winslow design, models. The transducers, fabricated in four different sizes ranging from 100 /spl mu/m/spl times/100 /spl mu/m to 1500 /spl mu/m/spl times/1500 /spl mu/m, were tested for impedance characteristics and electrical resonance modes were found at 15.6 MHz for the smallest membrane and 8.7 MHz for the largest one. Finally, the transducers were pulsed in a perfluorocarbon high dielectric strength solution, and echoes were received from an air-solution interface. This work shows the potential of thin film PZT for ultrasonic imaging transducers. The novel microfabrication process minimizes the transducer size and the spacing between individual devices while minimizing crosstalk. The use of the PZT allows for maximum sensitivity. A two dimensional array, like the one demonstrated in this work can be used for coronary artery imaging.","PeriodicalId":429072,"journal":{"name":"2001 Microelectromechanical Systems Conference (Cat. No. 01EX521)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2001-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125127125","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}