2008 IEEE Region 5 Conference最新文献

筛选
英文 中文
Designing of Shielded Two Coupled Striplines with Finite Element Method 屏蔽双耦合带状线的有限元设计
2008 IEEE Region 5 Conference Pub Date : 2008-04-17 DOI: 10.1109/TPSD.2008.4562725
S. Musa, M. Sadiku
{"title":"Designing of Shielded Two Coupled Striplines with Finite Element Method","authors":"S. Musa, M. Sadiku","doi":"10.1109/TPSD.2008.4562725","DOIUrl":"https://doi.org/10.1109/TPSD.2008.4562725","url":null,"abstract":"In this paper, we will illustrate designing of shielded two coupled stripline structures using finite element method (FEM). We present the designing of shielded two vertically coupled striplines and shielded two coupled striplines embedded in a dielectric material. We specifically determine the capacitance per unit length of shielded two coupled striplines. Excellent agreement with results obtained by previous investigators is demonstrated.","PeriodicalId":410786,"journal":{"name":"2008 IEEE Region 5 Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"126359271","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Voltage Inversion due to TCSC Presence on Second Circuit of Double Circuit Line and Distance Relay Mal-Operation Considering MOV Operation 考虑MOV操作的双回线路二回路TCSC存在引起的电压反转及距离继电器误动
2008 IEEE Region 5 Conference Pub Date : 2008-04-17 DOI: 10.1109/TPSD.2008.4562746
S. Jamali, A. Kazemi, H. Shateri
{"title":"Voltage Inversion due to TCSC Presence on Second Circuit of Double Circuit Line and Distance Relay Mal-Operation Considering MOV Operation","authors":"S. Jamali, A. Kazemi, H. Shateri","doi":"10.1109/TPSD.2008.4562746","DOIUrl":"https://doi.org/10.1109/TPSD.2008.4562746","url":null,"abstract":"This paper discusses the distance relay mal-operation in the case of installation of thyristor controlled series compensator (TCSC), one of the series connected flexible alternating current transmission system (FACTS) device, on the second circuit of a double circuit transmission line, considering its metal oxide varistor (MOV) operation. This is done by means of presenting the measured impedance at the relaying point in the case of TCSC presence at the near end of the second circuit. The measured impedance at the relaying point is greatly influenced in the presence of TCSC on the line or even in the case of installing TCSC on the near end of the second circuit. The measured impedance depends on many factors including the power system structural conditions, pre-fault loading, the ground fault resistance, and TCSC compensation degree.","PeriodicalId":410786,"journal":{"name":"2008 IEEE Region 5 Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2008-04-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129005949","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信