Ukrainian Metrological Journal最新文献

筛选
英文 中文
Implementation of the characteristic functions approach to measurement uncertainty evaluation 特征函数法在测量不确定度评定中的应用
IF 0.1
Ukrainian Metrological Journal Pub Date : 2022-03-31 DOI: 10.24027/2306-7039.1.2022.258818
V. Witkovský
{"title":"Implementation of the characteristic functions approach to measurement uncertainty evaluation","authors":"V. Witkovský","doi":"10.24027/2306-7039.1.2022.258818","DOIUrl":"https://doi.org/10.24027/2306-7039.1.2022.258818","url":null,"abstract":"Probability distributions suitable for modelling measurements and determining their uncertainties are usually based on a standard approximation approach as described in GUM, i.e. the GUM uncertainty framework (GUF), using the law of uncertainty propagation (also known as the delta method) or a more accurate method based on the law of probability propagation calculated using the Monte Carlo method (MCM). As an alternative to GUF and MCM, we present a characteristic function approach (CFA), which is suitable for determining measurement uncertainties by using the exact probability distribution of a measured quantity in linear measurement models by inverting the associated characteristic function (CF), which is defined as a Fourier transform of the probability density function (PDF). In this paper, we present the current state of the MATLAB implementation of the characteristic function approach (the toolbox CharFunTool) and illustrate the use and applicability of the CFA for determining the distribution and uncertainty evaluation with a simple example. The proposed approach is compared with GUM, MCM and the kurtosis uncertainty method (KUM).","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":" ","pages":""},"PeriodicalIF":0.1,"publicationDate":"2022-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"41762422","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Measurements of near-surface radial profiles of electrophysical characteristics of cylindrical objects by the eddy current method using a priori data 利用先验数据涡流法测量圆柱形物体电物理特性的近表面径向分布
IF 0.1
Ukrainian Metrological Journal Pub Date : 2022-03-31 DOI: 10.24027/2306-7039.1.2022.258678
V. Halchenko, A. Storchak, V. Tychkov, R. Trembovetska
{"title":"Measurements of near-surface radial profiles of electrophysical characteristics of cylindrical objects by the eddy current method using a priori data","authors":"V. Halchenko, A. Storchak, V. Tychkov, R. Trembovetska","doi":"10.24027/2306-7039.1.2022.258678","DOIUrl":"https://doi.org/10.24027/2306-7039.1.2022.258678","url":null,"abstract":"A new multiparameter express method for eddy-current measurement of radial near-surface profiles of electrophysical parameters of cylindrical control objects with a priori accumulation of information about them is proposed. The method combines in-situ measurements and model calculations using high-performance computing technologies of artificial intelligence based on neural networks, carried out both in advance in order to obtain specific information about objects, and directly in the process of performing measurements to quickly obtain a result. Mathematically, the method is based on the unique ability to quickly solve Maxwell's equations as a result of its approximation by deep neural networks without actually explicitly executing this solution. This allows deep learning to be used not only in the forward direction, but also in the opposite direction, i.e. apply to solve inverse measuring problems. The method is universal and can be extended to multiparameter measurement control with simultaneous additional determination of the diameter of a cylindrical object. The adequacy of the proposed method by numerical experiments is proved; examples of the implementation of all stages of its application are given. Algorithms and a complex of programs in the Python 3 environment have been created, which make it possible to practically implement the method. The profile measurement accuracy established on model calculations is characterized by maximum relative errors not exceeding 0.5%, provided that the probe signal is perfectly fixed. It is possible to generalize the use of the proposed method to similar eddy current measurements with surface probes of profiles of material parameters of flat objects.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":" ","pages":""},"PeriodicalIF":0.1,"publicationDate":"2022-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"47130586","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Precision active power measuring channel 精密有功功率测量通道
IF 0.1
Ukrainian Metrological Journal Pub Date : 2021-12-31 DOI: 10.24027/2306-7039.4.2021.250410
D. Ornatskyi, S. Yehorov, M. Kataieva, M. Graf, Dmytro Shcherbyna
{"title":"Precision active power measuring channel","authors":"D. Ornatskyi, S. Yehorov, M. Kataieva, M. Graf, Dmytro Shcherbyna","doi":"10.24027/2306-7039.4.2021.250410","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250410","url":null,"abstract":"The article is devoted to increasing the reliability, noise protection and improving the metrological characteristics of active power measuring converters. Much attention is paid to the problem of developing effective methods for constructing structural diagrams of active power measuring converters. This is explained by the growing requirements for the basic metrological characteristics of active power measuring converters as elements of information – measuring systems. \u0000The main attention in the work is paid to the development of ways to correct the influence of destabilizing factors in working conditions. The undoubted advantage of the work is a thorough analysis of the instrumental errors of the measuring channel, the original means of correction of the phase error and the error due to the limited suppression coefficients of in-phase interference. \u0000The obtained simulation results in the Electronics Workbench environment made it possible to determine the most effective way to protect against interference.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":" ","pages":""},"PeriodicalIF":0.1,"publicationDate":"2021-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44933098","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Application of systems thinking to the establishment of metrological traceability chains 系统思维在计量溯源链建立中的应用
IF 0.1
Ukrainian Metrological Journal Pub Date : 2021-12-30 DOI: 10.24027/2306-7039.4.2021.250348
O. Velychko, T. Gordiyenko
{"title":"Application of systems thinking to the establishment of metrological traceability chains","authors":"O. Velychko, T. Gordiyenko","doi":"10.24027/2306-7039.4.2021.250348","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250348","url":null,"abstract":"International agreements in the field of metrology and accreditation of calibration laboratories are the basis for establishing global metrological traceability. Important elements of metrological traceability are calibration of measurement standards and measuring instruments, assessment of measurement uncertainty. The International Laboratory Accreditation Cooperation has a specific policy regarding on traceability of measurement results and estimation of measurement uncertainty in calibration. \u0000The partial concept diagram around metrological traceability in accordance with the International Vocabulary of Metrology is proposed. This diagram contains a total of nine metrological concepts, which have most of the associative relations. There are associative relations between the concept of metrological traceability chain and concepts of metrological traceability, measurement standard, calibration and calibration hierarchy, and through the concept of measurement standard with the concept of measurement uncertainty. \u0000Systems thinking to the analysis of state of proposed terminological system around metrological traceability was applied. For construction of generalized metrological traceability chain, all the established properties of the system elements around the terminology system of metrological traceability were taken into account. \u0000Generalized metrological traceability chain for different levels of the calibration hierarchy was proposed. The proposed chain can be used to develop appropriate chains for specific areas of measurement. To achieve this, it is necessary to determine the specific measured value, the required measurement uncertainty for different levels of the calibration hierarchy and select the necessary measurement standards. Such schemes should be used in national metrology institutes and calibration laboratories.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":" ","pages":""},"PeriodicalIF":0.1,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"45374985","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Ensuring the validity of the results of calibrations and tests by statistical methods 通过统计方法确保校准和测试结果的有效性
IF 0.1
Ukrainian Metrological Journal Pub Date : 2021-12-30 DOI: 10.24027/2306-7039.4.2021.250375
Alexander Kolbasin
{"title":"Ensuring the validity of the results of calibrations and tests by statistical methods","authors":"Alexander Kolbasin","doi":"10.24027/2306-7039.4.2021.250375","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250375","url":null,"abstract":"According to the requirements of ISO/IEC 17025:2017, the validity of test and calibration results is ensured, inter alia, by intralaboratory check of the results obtained. In this case, it is preferable to use statistical methods. \u0000The ISO 5725 standards define a number of such methods, but the choice of specific methods is left to the laboratory, taking into account the requirements for the adequacy of the effort, resources and time for the purposes of the work performed and the risks of obtaining inappropriate results. In this case, the laboratory itself must in a certain way determine which objects of calibrations (tests) should be predominantly used in checks and what frequency of checks should be foreseen. \u0000In connection with the increase in the accuracy and complexity of measuring systems, the need to apply the methods of the theory of random processes becomes more and more obvious. It is shown that the use of the Poincaré plot makes it possible to comprehensively, effectively and visually evaluate changes in the measuring process from the point of view of the dynamics of the obtained measurement results. \u0000The results of the check, in particular, the intermediate precision, make it possible to obtain a more realistic evaluation of measurement uncertainty in accordance with ISO 21748. \u0000The paper analyses some practical approaches (of varying degrees of complexity) to intralaboratory checks of the validity of calibration (test) results.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":" ","pages":""},"PeriodicalIF":0.1,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"42443389","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Minimization of errors in discrete wavelet filtering of signals during ultrasonic measurements and testing 超声波测量和测试过程中信号离散小波滤波误差的最小化
IF 0.1
Ukrainian Metrological Journal Pub Date : 2021-12-30 DOI: 10.24027/2306-7039.4.2021.250433
Y. Taranenko, R. Mygushchenko, O. Kropachek, G. Suchkov, Yu. O. Plesnetsov
{"title":"Minimization of errors in discrete wavelet filtering of signals during ultrasonic measurements and testing","authors":"Y. Taranenko, R. Mygushchenko, O. Kropachek, G. Suchkov, Yu. O. Plesnetsov","doi":"10.24027/2306-7039.4.2021.250433","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250433","url":null,"abstract":"Error minimizing methods for discrete wavelet filtering of ultrasonic meter signals are considered. For this purpose, special model signals containing various measuring pulses are generated. The psi function of the Daubechies 28 wavelet is used to generate the pulses. Noise is added to the generated pulses. A comparative analysis of the two filtering algorithms is performed. The first algorithm is to limit the amount of detail of the wavelet decomposition coefficients in relation to signal interference. The minimum value of the root mean square error of wavelet decomposition signal deviation which is restored at each level from the initial signal without noise is determined. The second algorithm uses a separate threshold for each level of wavelet decomposition to limit the magnitude of the detail coefficients that are proportional to the standard deviation. Like in the first algorithm, the task is to determine the level of wavelet decomposition at which the minimum standard error is achieved. A feature of both algorithms is an expanded base of discrete wavelets ‒ families of Biorthogonal, Coiflet, Daubechies, Discrete Meyer, Haar, Reverse Biorthogonal, Symlets (106 in total) and threshold functions garotte, garrote, greater, hard, less, soft (6 in total). The model function uses random variables in both algorithms, so the averaging base is used to obtain stable results. Given features of algorithm construction allowed to reveal efficiency of ultrasonic signal filtering on the first algorithm presented in the form of oscilloscopic images. The use of a separate threshold for limiting the number of detail coefficients for each level of discrete wavelet decomposition using the given wavelet base and threshold functions has reduced the filtering error.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":" ","pages":""},"PeriodicalIF":0.1,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48237784","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Reduction of the auto seismic component of error of a ballistic laser gravimeter by excitation of an induction-dynamic catapult from an AC voltage source 交流电压激励感应动力弹射器降低弹道激光重力仪自震误差分量
IF 0.1
Ukrainian Metrological Journal Pub Date : 2021-12-30 DOI: 10.24027/2306-7039.4.2021.250401
V. Bolyukh, Оleksandr Vinnichenko, A. Omelchenko
{"title":"Reduction of the auto seismic component of error of a ballistic laser gravimeter by excitation of an induction-dynamic catapult from an AC voltage source","authors":"V. Bolyukh, Оleksandr Vinnichenko, A. Omelchenko","doi":"10.24027/2306-7039.4.2021.250401","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250401","url":null,"abstract":"The purpose of the study is to analyse the influence of the excitation of an induction-dynamic catapult of a ballistic laser gravimeter from an AC voltage source at different frequencies on electromechanical indicators that provide a reduced value of the auto seismic component of error in measuring the gravitational acceleration g due to a decrease in the recoil force. A mathematical model of the gravimeter catapult when excited from an AC voltage source is proposed, taking into account the interrelated electrical, magnetic and mechanical processes. The nature of the electromechanical processes in the catapult of the gravimeter with such excitation has been established. It is shown that a phase shift occurs between the currents in active elements, as a result of which positive (repulsive) pulses of the electrodynamic force alternate with negative (attractive) pulses of force. A criterion for the efficiency of the gravimeter catapult has been introduced, taking into account the maximum value of push of the test body at the smallest values of the electrodynamic force and current of the inductor winding. It was found that the highest efficiency of the gravimeter catapult is provided at a frequency of 250 Hz, at which the catapult efficiency is 3.5 times higher than at a frequency of 50 Hz. It is shown that the transition from the method of excitation of an induction-dynamic catapult with one short pulse to excitation from an AC voltage source makes it possible to reduce the uncertainty in measuring the gravitational acceleration.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":" ","pages":""},"PeriodicalIF":0.1,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"44898789","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Intrinsic background of the beta channel of the aerosol volumetric activity monitor 气溶胶体积活动性监测仪β通道的固有本底
IF 0.1
Ukrainian Metrological Journal Pub Date : 2021-12-30 DOI: 10.24027/2306-7039.4.2021.250425
A. Kozyrenko, O. Letuchyy, Andrei Pystovyi, V. Skliarov
{"title":"Intrinsic background of the beta channel of the aerosol volumetric activity monitor","authors":"A. Kozyrenko, O. Letuchyy, Andrei Pystovyi, V. Skliarov","doi":"10.24027/2306-7039.4.2021.250425","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250425","url":null,"abstract":"The work is devoted to the study of the features of generation of the intrinsic background of the measuring beta channel of the aerosol monitor in real conditions of measuring the volumetric activity of aerosols, caused by radionuclides of technogenic origin. \u0000The influence of external factors on the generation of the level of the intrinsic background of the measuring channel of the monitor and its metrological characteristics is investigated. \u0000The reliability of the results of measurements of the volumetric activity of air aerosols substantially depends on the correct accounting of external factors, parameters of the monitored environment and the specified operating mode of the monitor. \u0000Aerosol volumetric activity monitors, as a rule, operate in a continuous mode, in which the aspiration method of aerosol accumulation is implemented, followed by measuring the volumetric activity of aerosols by alpha radiation and (or) beta radiation generated by technogenic radionuclides. \u0000This article describes the results of experiments on measuring the iCAM aerosol monitor’s intrinsic beta channel background under real operating conditions, and its dependence on external factors. \u0000The studies were carried out on iCAM aerosol monitors (iCAM/D and iCAM/MF modifications) manufactured by Canberra Industries Inc. in a laboratory room in normal climatic conditions with a radon volumetric activity of 35±10 Bq·m-3 and an equivalent dose rate of gamma radiation of 0.13±0.02 μSv·h-1. \u0000In modern aerosol monitors, software and hardware solutions are implemented that allow to significantly reduce the background level and, as a result, to expand the measurement range of the volumetric activity of aerosols towards low values.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":" ","pages":""},"PeriodicalIF":0.1,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"48534638","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Method for the numerical evaluation of the color rendering quality of matrix photodetectors 矩阵光电探测器显色质量的数值评估方法
IF 0.1
Ukrainian Metrological Journal Pub Date : 2021-12-30 DOI: 10.24027/2306-7039.4.2021.250412
O. Kupko, O. Liashenko, P. Neyezhmakov, Yevhen Tymofeiev, Eduard Diumin, Natalia Mushchynska, Anatoliy Litvinenko
{"title":"Method for the numerical evaluation of the color rendering quality of matrix photodetectors","authors":"O. Kupko, O. Liashenko, P. Neyezhmakov, Yevhen Tymofeiev, Eduard Diumin, Natalia Mushchynska, Anatoliy Litvinenko","doi":"10.24027/2306-7039.4.2021.250412","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250412","url":null,"abstract":"To objectively evaluate the color image of an architectural object when changing its spectral quality and luminance in lighting, it is necessary to ensure its accurate fixation. The measurement of the color coordinates of an object provides the fully capture of its appearance, but this does not allow to get an adequate evaluation of the visual impression without visualizing the lighting scene. This requires a thorough procedure of reproducing the same color coordinates for each point of the image and the object with the same angular coordinates. In this work, an attempt is made to develop a numerical criterion for evaluating the quality of color rendering of the camera as a fixer of color visual impression of the selected scene. The development of a numerical detailed method for evaluation of the quality of color rendering of cameras will allow capturing more reliably such a subjective concept as the correspondence of the visual impression of the real scene and the image file of this scene. The digital format, which contains information about the object, avoids the problems associated with aging of the image. The proposed method of developing ways to numerically evaluate color distortion in photography is considered on the example of digital cameras Nikon D300s, Sony DSC-H5. The described approach for the case of known spectral characteristics allows to unambiguously link the calculated reaction of the camera with the chromaticity coordinates of spectrally pure colors. Modern methods of evaluating the quality of light sources (IES TM-30-15) allow evaluation of the direction of the shift. The proposed indicator – graph E (λi) numerically characterizes the difference between the reaction of the camera and the reaction of the human eye and does not give an idea in which direction there is a difference, conditionally red or blue image compared to the natural scene, but is the simplest and most understandable to the untrained user. It is shown that with an accuracy of measuring spectral characteristics of 1% for the considered example with Nikon D300s, this indicator at different wavelengths is calculated with an uncertainty of not more than 0.002.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":" ","pages":""},"PeriodicalIF":0.1,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"49376835","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Informational uncertainty of measuring instruments 测量仪器的信息不确定度
IF 0.1
Ukrainian Metrological Journal Pub Date : 2021-12-30 DOI: 10.24027/2306-7039.4.2021.250399
Gennadii Manko, Elena Titova
{"title":"Informational uncertainty of measuring instruments","authors":"Gennadii Manko, Elena Titova","doi":"10.24027/2306-7039.4.2021.250399","DOIUrl":"https://doi.org/10.24027/2306-7039.4.2021.250399","url":null,"abstract":"Recently, there has been a revival of interest in the use of the information approach in the theory of measurements. Unlike the traditional approach, information theory does not evaluate error or uncertainty, but entropy and the amount of information. This article analyzes a number of recent publications that develop ideas for the information approach. The limitations and disadvantages of both the entropy approach and the concept of uncertainty are indicated. As a compromise solution, it is proposed to use a criterion based on the Bongard’s uncertainty and useful information. The concept of information uncertainty is proposed, which is estimated by the amount of negative useful information, that is, misinformation introduced by the measuring instrument. Some methods for calculating information uncertainty are described. \u0000The problems of using the uncertainty approach are noted. This approach does not imply the use of such a generalized characteristic of measuring instruments as an accuracy class. The article proposes an analogue of the accuracy class in the form of relative informational uncertainty, expressed as a percentage. This will make it possible to evaluate the quality of the measuring instrument by a single parameter, the calculation of which requires a minimum of computational operations.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":"1 1","pages":""},"PeriodicalIF":0.1,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"68826998","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信