{"title":"Design and characteristic analysis of 10 MW class superconducting wind turbine generators with different types of stator and rotor configurations","authors":"H. Ohsaki, L. Quéval, Y. Terao","doi":"10.1109/ICCEP.2013.6587020","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6587020","url":null,"abstract":"Wind power generation facilities have been installed in the world. Recently offshore wind energy attracts greater attention, and development of wind turbine generators of higher power rating becomes more important. Superconducting technologies is expected to be applied to over 10 MW class generators. We have studied 10 MW class large wind turbine generators using superconducting technologies. The paper presents fundamental structures of large-scale wind turbine generators, paying attention to the reduction of superconducting wire length, and generator size and weight. Some design results of 10 MW wind turbine generators are shown and compared.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131593399","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Three-phase tri-state buck-boost integrated inverter","authors":"M. D. de Brito, C. Canesin","doi":"10.1109/ICCEP.2013.6586938","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586938","url":null,"abstract":"This paper presents a three-phase integrated inverter suitable for stand-alone and/or grid-connected applications. The usage of the special features of the tri-state coupled with the special space vector modulation allows the inverter to present an attractive degree of freedom for the controllers' design, i.e. input and output can be controlled independently. Additionally all controllers are based on dq0 transformation, the system are described and interesting simulation results are available to confirm the proposal. Finally, this paper presents experimental evaluations of the inverter feeding a three-phase stand-alone load confirming the remarkable features of the decoupling control.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133363495","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
M. Raffero, Andrea Cagninei, E. Giorcelli, G. Mattiazzo, Davide Poggi, Vincenzo Orlando
{"title":"Control and productivity analysis of the full scale ISWEC prototype","authors":"M. Raffero, Andrea Cagninei, E. Giorcelli, G. Mattiazzo, Davide Poggi, Vincenzo Orlando","doi":"10.1109/ICCEP.2013.6586995","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586995","url":null,"abstract":"In the past four decades, hundreds of Wave Energy Converters (WECs) have been proposed and studied, but so far a final architecture to harvest wave power has not been identified. Many engineering problems are still to be solved, like survivability, durability and effective power capture in a variable wave climate. ISWEC (Inertial Sea Wave Energy Converter) is a system using the gyroscope to extract power. The goal of this paper is to identify an optimal control strategy in order to maximize wave power exploitation of ISWEC. Here we present a new adaptive control technique and the results deriving from its application to an ISWEC device with rated power of 60kW. ISEWC with the new control strategy are finally applied to the test case of Alghero, and the results in terms of power potential and yearly productivity are shown.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127630332","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Large scale regional adoption of electric vehicles in Norway and the potential for using wind power as source","authors":"Oystein Sagosen, M. Molinas","doi":"10.1109/ICCEP.2013.6586988","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586988","url":null,"abstract":"Recent years attitude towards climate and CO2 emissions has accelerated the sale of electric and hybrid vehicles in Norway. By the end of 2012 there were 10 000 battery electric vehicles registered. Projections indicate that Norway may surpass 200 000 chargeable vehicles by 2020, counting both battery electric vehicles and hybrid electric vehicles. This corresponds to 7 % of the total vehicle fleet. To explore the impact a large scale electric vehicle adoption will have on the power grid, simulations of an existing low voltage power system has been conducted. The load flow simulation tool Simpow was used for this purpose, and Nord-Trondelag Elektrisitetsverk provided information of the grid structure and consumer consumption data. From the supplied data, December 22 was chosen for the 24 hour simulation period, because it represents the highest energy consumption scenario. A hypothetically built wind turbine close to the residences was integrated in the system, using wind measurement data from a wind farm in Nord-Trondelag. Different scenarios with regards to electric vehicle charging were explored, investigating how sensitive the grid is to additional load under different assumption patterns, and how the wind generation can contribute to a more self-sustained power system. Symmetrical and asymmetrical distribution in relation to physical location of the additional load has been compared, and the results suggest that one cannot give an exact number of vehicles that the system can handle. This system capacity when operating with dumb charging strategies is somewhere between 4 and 22 electric vehicles, depending on where the vehicles are situated physically. In other words, the placements of the additional loads are equally decisive for the system voltage variations as the number of loads are. By applying smart charging strategies, it seems the system is able to handle a large share of electric vehicle adoption. Wind generation during December 22 is higher than the residence base consumption, resulting in 593 kWh excess energy in the system. An energy storage of a 100 kWh capacity in addition to the wind generation could cover base load if the system was to operate without grid connection. Additionally, the excess energy could potentially be used to charge electric vehicles.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127827622","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
P. Guerriero, V. d’Alessandro, L. Petrazzuoli, G. Vallone, S. Daliento
{"title":"Effective real-time performance monitoring and diagnostics of individual panels in PV plants","authors":"P. Guerriero, V. d’Alessandro, L. Petrazzuoli, G. Vallone, S. Daliento","doi":"10.1109/ICCEP.2013.6586958","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586958","url":null,"abstract":"In this paper, we present an improved version of a recently-developed monitoring circuit devised to measure the operating voltage and current, the open circuit voltage, and the short circuit current of string-connected photovoltaic (PV) panels. The system can substitute the junction box, is fully self-powered, and does not require additional cables thanks to a wireless communication. An extensive experimental campaign is performed to prove the reliability and usefulness of the system for continuous monitoring of PV plants; in particular, the capability to detect the effects of partial shading conditions on a PV string is highlighted.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115880364","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"A new approach to maximum power point tracking for photovoltaic panels","authors":"L. Cristaldi, M. Faifer, M. Rossi, S. Toscani","doi":"10.1109/ICCEP.2013.6586917","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586917","url":null,"abstract":"Maximum Power Point Tracking (MPPT) algorithms are essential to optimize the conversion efficiency of photovoltaic (PV) panels in every working condition. Many techniques have been presented in literature, and the most common are the perturb and observe (P&O) and the incremental conductance (INC) methods. Their parameters result from a trade-off between steady state accuracy and dynamic performance. When the power electronics converter is connected to a single PV panel (module integrated converter, MIC) model-based (MB) MPPT techniques appear to be attractive because of their fast response to rapidly changing conditions. In a recent paper the authors have presented a novel MB MPPT algorithm which requires a pyranometer just during a preliminary training process. In this work it will be shown how the direct measurement of the solar radiation can be avoided at all, without scarifying the performance. The method has been validated through an extensive experimental activity.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129712895","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
{"title":"Electromagnetic parameter characterization of a short-stroke linear PM generator for renewable energy application","authors":"M. Andriollo, L. Dall'Ora, A. Tortella","doi":"10.1109/ICCEP.2013.6587018","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6587018","url":null,"abstract":"The paper describes a procedure to determine the electromagnetic parameters of a short-stroke single-phase tubular permanent magnet linear generator (TPMLG) by the elaboration of suitable experimental tests executed on a three-pole prototype. In particular, the magnetic properties of the stator SMC core as well as of the mover PM magnetization profile are determined by a procedure matching static measurements and results of corresponding finite element analyses (FEAs). Such procedure enables to identify more accurately the material magnetic properties, since results evidenced remarkably poorer characteristics with respect to the material reference datasheets, likely due to manufacturing processes. Corrected magnetic parameters are then used to quantify the performance de-rating with respect to the preliminary design as for voltage, force and stator core losses, in order to assess possible design modifications.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129316941","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
I. Aizpuru, U. Iraola, J. M. Canales, M. Echeverria, I. Gil
{"title":"Passive balancing design for Li-ion battery packs based on single cell experimental tests for a CCCV charging mode","authors":"I. Aizpuru, U. Iraola, J. M. Canales, M. Echeverria, I. Gil","doi":"10.1109/ICCEP.2013.6586973","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586973","url":null,"abstract":"High power battery systems are composed of big array of series connected single cells. The main reason of increasing battery pack voltage is, to increase power by decreasing current and improve the efficiency. To control the charge and voltage of each cell a BMS with balancing system is necessary. Battery modeling is hard work, and battery dispersion and deviations are not taken into account. To overcome this problem, in this work a passive balancing system design procedure is presented based on single cell experimental tests. Battery modeling is avoided and main deviations between batteries are taken into account. Main parameters are taken into account during the design procedure. Finally design procedure is compared with experimental results.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"129658857","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
J. Accarino, G. Petrone, C. Ramos-Paja, G. Spagnuolo
{"title":"Symbolic algebra for the calculation of the series and parallel resistances in PV module model","authors":"J. Accarino, G. Petrone, C. Ramos-Paja, G. Spagnuolo","doi":"10.1109/ICCEP.2013.6586967","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586967","url":null,"abstract":"In this paper a symbolic analysis of the equations that allow to calculate the values of the series and parallel resistances appearing in the single diode model of a photovoltaic module is presented. Such a model requires the identification of five values, that are the photo-induced current, the diode ideality factor and saturation current, the series and parallel resistances. This calculation can be done on the basis of the few data taken from the module data sheet or by using a fitting process starting from experimental measurements. In this paper the first case is considered: it allows to identify the parameters' values in the standard test conditions and requires a solution of a non linear system of equations. In this paper the problem is afforded by using symbolic calculations only: the main result is the explicit expressions giving the values of all the five parameters. The explicit formulas allow to avoid the convergence problems that are typical of the methods based on the solution of a non linear system of equations. Nonetheless, the values obtained by using the proposed procedure can be used as guess solution for a more accurate calculation.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127366528","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
Y. Gritli, A. D. Di Tommaso, R. Miceli, F. Filippetti, C. Rossi
{"title":"Closed-loop bandwidth impact on MVSA for rotor broken bar diagnosis in IRFOC double squirrel cage induction motor drives","authors":"Y. Gritli, A. D. Di Tommaso, R. Miceli, F. Filippetti, C. Rossi","doi":"10.1109/ICCEP.2013.6586904","DOIUrl":"https://doi.org/10.1109/ICCEP.2013.6586904","url":null,"abstract":"This paper investigates the detectability of rotor broken bars in indirect rotor flux oriented control (IRFOC) for variable speed double cage induction motor drives, using vibration signature analysis techniques. The Impact of the closed loop control system cannot be neglected when the detection of rotor asymmetries in the machine is based on the signature analysis of electrical or mechanical variables. Therefore, the investigation of rotor fault components for different bandwidths of closed-loop regulators is necessary to evaluate its relevance in the above listed variables. This paper investigates the impact of the control system on relevance of the fault components computed from axial and radial vibration signals. Experimental results show the validity of this impact, and more specifically, the bandwidth PI regulators. Due to its relevance, axial vibration analysis shows a more robust fault signature, under the control impact, in separating healthy from rotor bar breakage in double squirrel cage induction motors.","PeriodicalId":401930,"journal":{"name":"2013 International Conference on Clean Electrical Power (ICCEP)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2013-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127491173","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}